Report: Test Configuration 1
Test failed
General Test Information
Tester
Windows Login Name: H1O8VP
Test Setup
Version: CANoe.CAN.LIN /run 15.5.23 (SP5)
Configuration: C:\repozytoria\SPA_VTS\VOLVO\it_v_vcc_gpa_swm\Simulation\Config\VCC_GPA_SWM_VTS.cfg
Database GPAsystem_MAIN_111_SWM2CANCfg_240202 on SWM2CAN: C:\repozytoria\SPA_VTS\VOLVO\it_v_vcc_gpa_swm\Simulation\DataBases\DataBase_From_Volvo\24w06\GPAsystem_MAIN_111_SWM2CANCfg_240202.dbc (2024-06-18 17:04:51)
Database GPAsystem_MAIN_111_SWM1LINCfg_240202 on LIN: C:\repozytoria\SPA_VTS\VOLVO\it_v_vcc_gpa_swm\Simulation\DataBases\DataBase_From_Volvo\24w06\GPAsystem_MAIN_111_SWM1LINCfg_240202.ldf (2024-06-11 13:28:12)
Diagnostic Description of SWM: SWM_80016153_AA, en-US, C:\repozytoria\SPA_VTS\VOLVO\it_v_vcc_gpa_swm\Simulation\DataBases\CANdela\VCC_SWM_CANdela_20240410.cdd (1.15, 2024-04-08 16:40:33+02:00)
Test Configuration: Test Configuration 1
Windows Computer Name: DL6YMRZM2
Nodelayer Module CANoeILNLVector: CANoe Interaction Layer NL (Vector) Version 3.17.95 (Mar 24 2021 10:44:54) , c:\CANrtk\Exec64\SynchronizedFiles\CANoeILNLVector.dll
Nodelayer Module AsrNM33: AsrNM (Version 3.3.72 Windows 64-Bit), c:\CANrtk\Exec64\SynchronizedFiles\AsrNM33.dll
Nodelayer Module J1939TestServiceLibraryNL: J1939 Test Service Library for CANoe, Version 15.5.23.0, c:\CANrtk\Exec64\SynchronizedFiles\J1939TestServiceLibraryNL.dll
Nodelayer Module CANstress_NL: CANstress NodeLayer for CANoe Version 3.1.1, c:\CANrtk\Exec64\SynchronizedFiles\CANstress_NL.dll
Nodelayer Module C2X_IL: Car2x Interaction Layer for Vector CANalyzer.Car2x/CANoe.Car2x, Version 15.5.23, c:\CANrtk\Exec64\SynchronizedFiles\C2X_IL.dll
Hardware
CAN Channel Interfaces
Channel Device Serial number Driver DLL version Driver version
1 VT6104B 1098 23.10.10 22.14.15
LIN Channel Interfaces
Channel Device Serial number Driver DLL version Driver version LIN Firmware version
1 VT6104B 1098 23.10.10 22.14.15 1.81
VT-System
Device Serial number Firmware version Hardware version
VT8012B 316 0.0.0 0x0
VT6104B 1098 0.0.0 0x1
VT2820 7783 1.0.0 0x0
VT2820 7779 1.0.0 0x0
VT2816A 1722 2.0.0 0x1
VT2848 5815 1.2.10 0x10
VT2710 2151 1.1.4 0x0
Logging and video recordings
Start Time End Time Logging/Video File
Active at test start 23.282517 ..\VOLVO\E4Raporty\Test_Configuration_1_TestUnit_VCC_GPA_SWM_VTS_Check_SW_hash_and_log_in_report_-_APP_2024-06-19_14-53-44_T1367.asc
20.282517 25.842485 ..\VOLVO\E4Raporty\Test_Configuration_1_TestUnit_VCC_GPA_SWM_VTS_Check_SW_hash_and_log_in_report_-_BTLD_2024-06-19_14-53-44_T1368.asc
22.842485 254.481782 ..\VOLVO\E4Raporty\Test_Configuration_1_TestUnit_VCC_GPA_SWM_VTS_B183F2A_FDC10__2024-06-19_14-53-44_T1369.asc
251.481782 1307.908343 ..\VOLVO\E4Raporty\Test_Configuration_1_TestUnit_VCC_GPA_SWM_VTS_B183F2A_-_OCC_1_Operation_cycle_since_last_failed_2024-06-19_14-53-44_T1370.asc
1304.908343 6266.471962 ..\VOLVO\E4Raporty\Test_Configuration_1_TestUnit_VCC_GPA_SWM_VTS_B183F2A_-_OCC_2_Fault_free_operation_cycles_since_first_failed_2024-06-19_14-53-44_T1371.asc
6263.471962 6486.307750 ..\VOLVO\E4Raporty\Test_Configuration_1_TestUnit_VCC_GPA_SWM_VTS_B183F2A_-_OCC_4_Total_number_of_failed_cycles_2024-06-19_14-53-44_T1372.asc
6483.307750 6504.995374 ..\VOLVO\E4Raporty\Test_Configuration_1_TestUnit_VCC_GPA_SWM_VTS_B183F2A_-_OCC_6_Consecutive_number_of_faulty_operation_cycles_2024-06-19_14-53-44_T1373.asc
6501.995374 6722.827232 ..\VOLVO\E4Raporty\Test_Configuration_1_TestUnit_VCC_GPA_SWM_VTS_B183F2A_DTC_Storage__2024-06-19_14-53-44_T1374.asc
6719.827232 7345.341884 ..\VOLVO\E4Raporty\Test_Configuration_1_TestUnit_VCC_GPA_SWM_VTS_B183F2A_-_SI_30__2024-06-19_14-53-44_T1375.asc
7342.341884 Active at test end ..\VOLVO\E4Raporty\Test_Configuration_1_TestUnit_VCC_GPA_SWM_VTS_B183F2A_-_TRC_2024-06-19_14-53-44_T1376.asc
Test Overview
Test begin: 2024-06-19 14:54:03 (logging timestamp 18.711240)
Test end: 2024-06-19 17:00:05 (logging timestamp 7581.106698)
Statistics
Executed test cases 10
Test cases passed 2 20% of executed test cases
Test cases inconclusive 0 0% of executed test cases
Test cases failed 8 80% of executed test cases
Test cases with error in test system 0 0% of executed test cases
Number of failures outside of test cases
Inconclusive 0
Fail 0
Error in test system 0
Not executed test cases
Some elements were not executed because they were deactivated by the tester.
Test Results
1 TestUnit_VCC_GPA_SWM_VTS fail
1.1 VTS_SW_Checksum
2
1.1.1 Check SW hash and log in report - APP pass
1.1.2 Check SW hash and log in report - BTLD pass
VTS_Autodiagnostics not executed
1.2 VTS_Bootloader not executed
VTS_DTC not executed
1.3 Right Stalk General Signal Failures Signal Stuck In Range
8
1.3.1 B183F2A FDC10 fail
1.3.2 B183F2A - OCC 1 Operation cycle since last failed fail
1.3.3 B183F2A - OCC 2 Fault free operation cycles since first failed fail
1.3.4 B183F2A - OCC 4 Total number of failed cycles fail
1.3.5 B183F2A - OCC 6 Consecutive number of faulty operation cycles fail
1.3.6 B183F2A DTC Storage fail
1.3.7 B183F2A - SI 30 fail
1.3.8 B183F2A - TRC fail
1.4 Right Stalk General Signal Failures Signal signal invalid not executed
1.5 Left Stalk General Signal Failures Signal signal invalid not executed
1.6 VTS_UDS not executed
VTS_Safety not executed
VTS_Robustness not executed
VTS_InterfaceRequirementsSpecification not executed
VTS_SysIntegration not executed
Test Configuration Information
Test Case Details
[−] 1 Test Unit: TestUnit_VCC_GPA_SWM_VTS
General Information
Name: TestUnit_VCC_GPA_SWM_VTS
Description:
Version:
File: C:\repozytoria\SPA_VTS\VOLVO\it_v_vcc_gpa_swm\TestProjects\TestProject\TestUnit_VCC_GPA_SWM_VTS\TestUnit_VCC_GPA_SWM_VTS.vtuexe
Last modification: 2024-06-19, 14:52:28
[−] 1.1 Test Group: VTS_SW_Checksum Test Case Verdicts
2
[−] 1.1.1 Check SW hash and log in report - APP: Passed
Test case begin: 2024-06-19 14:54:03 (logging timestamp 18.711240)
Test case end: 2024-06-19 14:54:05 (logging timestamp 21.282517)
Attributes
Safety Level: QM
Priority: Normal
Type: Automated
[expand test steps] [collapse test steps]
Variable definition
Name Type Value
SW_hash_B0 int 0
SW_hash_B1 int 123
SW_hash_B2 int 156
SW_hash_B3 int 240
SW_hash_B4 int 161
SW_hash_B5 int 186
SW_hash_B6 int 48
SW_hash_B7 int 98
SW_hash_B8 int 4
SW_hash_B9 int 3
SW_hash_B10 int 216
SW_hash_B11 int 84
SW_hash_B12 int 26
SW_hash_B13 int 180
SW_hash_B14 int 63
SW_hash_B15 int 153
Preparation of Test Case
Timestamp Test Step Description Result
18.711240 VT System Cards Configuration General-Purpose Relay Module - M2_VT2820 -
18.711240 VT System Cards Configuration General-Purpose Analog I/O Module - M4_VT2816 -
18.711240 VT System Cards Configuration General-Purpose Digital I/O Module - M5_VT2848 -
18.711240 VT System Cards Configuration Network Module - M1_VT6204 -
18.711240 VT System Cards Configuration Serial Interface Module - M6_VT2710 -
18.711240 VT System Cards Configuration General-Purpose Relay Module - M2_VT2820 -
1. Change the state of the relay, Expected: VCC line connected to DUT: Passed
18.711240 Change Relay State Relay vt2820_channel_13 - Relay 13 state was changed to PUSHED pass
2. Change the state of the relay, Expected: GND line connected to DUT: Passed
18.711240 Change Relay State Relay vt2820_channel_14 - Relay 14 state was changed to PUSHED pass
3. Set the supply voltage of the DUT, Expected: Voltage = 12.0 V: Passed
3.1. VTS_Set_Power_Supply_Voltage_RangeZeroTo28V: Passed
18.711240 Set power supply voltage Voltage set properly to 12.000000 V on vt2816_13 channel pass
4. Wait for configuration to be set: None
18.811240 1 Waited for 100.000 (setup_time_1) ms -
5. Wait for start diagnostic: None
21.211240 1 Waited for 2400.000 (diagnostic_start_time) ms -
6. Set diagnostic target: None
21.211240 Set Diagnostic Target Diagnostic target was changed to 'SWM' -
7. Start default diagnostic session. Expected: Positive response: Passed
21.211240 Diagnostic request 0x10, 0x01 -
21.213587 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=2.3475ms (max=1000ms) -
21.213587 Send diagnostic request to SCCM Diagnostic Session Control - Deafult Session (0x10 0x01) -
21.222486 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.89861ms (max=1200ms) -
21.222486 Get Diagnostic Response Positive response was received. -
21.222486 Diagnostic response 0x50, 0x01, 0x00, 0x32, 0x01, 0xF4 -
21.222486 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
8. Wait for 10 ms: None
21.232486 1 Waited for 10.000 ms -
Main Part of Test Case
Timestamp Test Step Description Result
1. Send diagnostic request 22 F1 F2 to read application hash. Expected: Positive response: Passed
21.233714 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.22816ms (max=1000ms) -
21.233714 Send Diagnostic Request Diagnostic request was succesfully transmitted. -
21.233714 Diagnostic request 0x22, 0xF1, 0xF2 -
21.272517 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=38.8031ms (max=1200ms) -
21.272517 Get Diagnostic Response Positive response was received. -
21.272517 Diagnostic response 0x62, 0xF1, 0xF2, 0x00, 0x7B, 0x9C, 0xF0, 0xA1, 0xBA, 0x30, 0x62, 0x04, 0x03, 0xD8, 0x54, 0x1A, 0xB4, 0x3F, 0x99, 0x00, 0x7B, 0x9C, 0xF0, 0xA1, 0xBA, 0x30, 0x62, 0x04, 0x03, 0xD8, 0x54, 0x1A, 0xB4.. -
21.272517 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
2. Copmare reference hash value with value calculated at runtime. Expected: Both values are equal: Passed
21.272517 1
[−] Check of expected values
Symbol Op. Reference value Actual Result
Variable 'SW_hash_B0' == 0 (DIAG_RESP_B21) 0 pass
Variable 'SW_hash_B1' == 123 (DIAG_RESP_B22) 123 pass
Variable 'SW_hash_B2' == 156 (DIAG_RESP_B23) 156 pass
Variable 'SW_hash_B3' == 240 (DIAG_RESP_B24) 240 pass
Variable 'SW_hash_B4' == 161 (DIAG_RESP_B25) 161 pass
Variable 'SW_hash_B5' == 186 (DIAG_RESP_B26) 186 pass
Variable 'SW_hash_B6' == 48 (DIAG_RESP_B27) 48 pass
Variable 'SW_hash_B7' == 98 (DIAG_RESP_B28) 98 pass
Variable 'SW_hash_B8' == 4 (DIAG_RESP_B29) 4 pass
Variable 'SW_hash_B9' == 3 (DIAG_RESP_B30) 3 pass
Variable 'SW_hash_B10' == 216 (DIAG_RESP_B31) 216 pass
Variable 'SW_hash_B11' == 84 (DIAG_RESP_B32) 84 pass
Variable 'SW_hash_B12' == 26 (DIAG_RESP_B33) 26 pass
Variable 'SW_hash_B13' == 180 (DIAG_RESP_B34) 180 pass
Variable 'SW_hash_B14' == 63 (DIAG_RESP_B35) 63 pass
Variable 'SW_hash_B15' == 153 (DIAG_RESP_B36) 153 pass
pass
Completion of Test Case
Timestamp Test Step Description Result
1. Wait for 10 ms: None
21.282517 1 Waited for 10.000 ms -
[−] 1.1.2 Check SW hash and log in report - BTLD: Passed
Test case begin: 2024-06-19 14:54:05 (logging timestamp 21.282517)
Test case end: 2024-06-19 14:54:08 (logging timestamp 23.842485)
Attributes
Safety Level: QM
Priority: Normal
Type: Automated
[expand test steps] [collapse test steps]
Variable definition
Name Type Value
SW_hash_B0 int 253
SW_hash_B1 int 32
SW_hash_B2 int 13
SW_hash_B3 int 35
SW_hash_B4 int 222
SW_hash_B5 int 82
SW_hash_B6 int 126
SW_hash_B7 int 37
SW_hash_B8 int 115
SW_hash_B9 int 213
SW_hash_B10 int 115
SW_hash_B11 int 114
SW_hash_B12 int 249
SW_hash_B13 int 182
SW_hash_B14 int 75
SW_hash_B15 int 64
Preparation of Test Case
Timestamp Test Step Description Result
21.282517 VT System Cards Configuration General-Purpose Relay Module - M2_VT2820 -
21.282517 VT System Cards Configuration General-Purpose Analog I/O Module - M4_VT2816 -
21.282517 VT System Cards Configuration General-Purpose Digital I/O Module - M5_VT2848 -
21.282517 VT System Cards Configuration Network Module - M1_VT6204 -
21.282517 VT System Cards Configuration Serial Interface Module - M6_VT2710 -
21.282517 VT System Cards Configuration General-Purpose Relay Module - M2_VT2820 -
1. Change the state of the relay, Expected: VCC line connected to DUT: Passed
21.282517 Change Relay State Relay vt2820_channel_13 - Relay 13 state was changed to PUSHED pass
2. Change the state of the relay, Expected: GND line connected to DUT: Passed
21.282517 Change Relay State Relay vt2820_channel_14 - Relay 14 state was changed to PUSHED pass
3. Set the supply voltage of the DUT, Expected: Voltage = 12.0 V: Passed
3.1. VTS_Set_Power_Supply_Voltage_RangeZeroTo28V: Passed
21.282517 Set power supply voltage Voltage set properly to 12.000000 V on vt2816_13 channel pass
4. Wait for configuration to be set: None
21.382517 1 Waited for 100.000 (setup_time_1) ms -
5. Wait for start diagnostic: None
23.782517 1 Waited for 2400.000 (diagnostic_start_time) ms -
6. Set diagnostic target: None
23.782517 Set Diagnostic Target Diagnostic target was changed to 'SWM' -
7. Start default diagnostic session. Expected: Positive response: Passed
23.782517 Diagnostic request 0x10, 0x01 -
23.784083 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.56567ms (max=1000ms) -
23.784083 Send diagnostic request to SCCM Diagnostic Session Control - Deafult Session (0x10 0x01) -
23.792442 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.3595ms (max=1200ms) -
23.792442 Get Diagnostic Response Positive response was received. -
23.792442 Diagnostic response 0x50, 0x01, 0x00, 0x32, 0x01, 0xF4 -
23.792442 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
8. Wait for 10 ms: None
23.802442 1 Waited for 10.000 ms -
Main Part of Test Case
Timestamp Test Step Description Result
1. Send diagnostic request 22 F1 F3 to read bootloader hash. Expected: Positive response: Passed
23.803716 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.27323ms (max=1000ms) -
23.803716 Send Diagnostic Request Diagnostic request was succesfully transmitted. -
23.803716 Diagnostic request 0x22, 0xF1, 0xF3 -
23.832485 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=28.7693ms (max=1200ms) -
23.832485 Get Diagnostic Response Positive response was received. -
23.832485 Diagnostic response 0x62, 0xF1, 0xF3, 0xFD, 0x20, 0x0D, 0x23, 0xDE, 0x52, 0x7E, 0x25, 0x73, 0xD5, 0x73, 0x72, 0xF9, 0xB6, 0x4B, 0x40, 0xFD, 0x20, 0x0D, 0x23, 0xDE, 0x52, 0x7E, 0x25, 0x73, 0xD5, 0x73, 0x72, 0xF9, 0xB6.. -
23.832485 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
2. Copmare reference hash value with value calculated at runtime. Expected: Both values are equal: Passed
23.832485 1
[−] Check of expected values
Symbol Op. Reference value Actual Result
Variable 'SW_hash_B0' == 253 (DIAG_RESP_B21) 253 pass
Variable 'SW_hash_B1' == 32 (DIAG_RESP_B22) 32 pass
Variable 'SW_hash_B2' == 13 (DIAG_RESP_B23) 13 pass
Variable 'SW_hash_B3' == 35 (DIAG_RESP_B24) 35 pass
Variable 'SW_hash_B4' == 222 (DIAG_RESP_B25) 222 pass
Variable 'SW_hash_B5' == 82 (DIAG_RESP_B26) 82 pass
Variable 'SW_hash_B6' == 126 (DIAG_RESP_B27) 126 pass
Variable 'SW_hash_B7' == 37 (DIAG_RESP_B28) 37 pass
Variable 'SW_hash_B8' == 115 (DIAG_RESP_B29) 115 pass
Variable 'SW_hash_B9' == 213 (DIAG_RESP_B30) 213 pass
Variable 'SW_hash_B10' == 115 (DIAG_RESP_B31) 115 pass
Variable 'SW_hash_B11' == 114 (DIAG_RESP_B32) 114 pass
Variable 'SW_hash_B12' == 249 (DIAG_RESP_B33) 249 pass
Variable 'SW_hash_B13' == 182 (DIAG_RESP_B34) 182 pass
Variable 'SW_hash_B14' == 75 (DIAG_RESP_B35) 75 pass
Variable 'SW_hash_B15' == 64 (DIAG_RESP_B36) 64 pass
pass
Completion of Test Case
Timestamp Test Step Description Result
1. Wait for 10 ms: None
23.842485 1 Waited for 10.000 ms -
End of Test Group: VTS_SW_Checksum
[−] 1.3 Test Group: Right Stalk General Signal Failures Signal Stuck In Range Test Case Verdicts
8
[−] 1.3.1 B183F2A FDC10 : Failed
Test case begin: 2024-06-19 14:54:08 (logging timestamp 23.842485)
Test case end: 2024-06-19 14:57:56 (logging timestamp 252.481782)

Link (managed by: vTESTstudio Traceability): REQ-90063v4 Fault Detection Counter 10 (FDC10)

Link (managed by: vTESTstudio Traceability): DTC 17 - Right Stalk General Signal Failures Signal Stuck In Range

Link (managed by: vTESTstudio Traceability): REQ-90095v4 Data types and classifications

Link (managed by: vTESTstudio Traceability): REQ-90105v4 Compliance to ISO 14229-1

Attributes
Safety Level: QM
Priority: Normal
Type: Automated
[expand test steps] [collapse test steps]
Preparation of Test Case
Timestamp Test Step Description Result
23.842485 VT System Cards Configuration General-Purpose Relay Module - M2_VT2820 -
23.842485 VT System Cards Configuration General-Purpose Analog I/O Module - M4_VT2816 -
23.842485 VT System Cards Configuration General-Purpose Digital I/O Module - M5_VT2848 -
23.842485 VT System Cards Configuration Network Module - M1_VT6204 -
23.842485 VT System Cards Configuration Serial Interface Module - M6_VT2710 -
23.842485 VT System Cards Configuration General-Purpose Relay Module - M2_VT2820 -
1. Change the state of the relay, Expected: VCC line connected to DUT: Passed
23.842485 Change Relay State Relay vt2820_channel_13 - Relay 13 state was changed to PUSHED pass
2. Change the state of the relay, Expected: GND line connected to DUT: Passed
23.842485 Change Relay State Relay vt2820_channel_14 - Relay 14 state was changed to PUSHED pass
3. Set the supply voltage of the DUT, Expected: Voltage = 12.0 V: Passed
3.1. VTS_Set_Power_Supply_Voltage_RangeZeroTo28V: Passed
23.842485 Set power supply voltage Voltage set properly to 12.000000 V on vt2816_13 channel pass
4. Wait for configuration to be set: None
23.942485 1 Waited for 100.000 (setup_time_1) ms -
5. Wait for diagnostic start: None
28.942485 1 Waited for 5.000 s -
Main Part of Test Case
Timestamp Test Step Description Result
1. Send diagnostic request "Clear Diagnostic Information" Expected: Positive response: Passed
28.943766 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.2812ms (max=1000ms) -
28.943766 Clear Diagnostic Information Request Clear Diagnostic Information was succesfully transmitted. -
28.963415 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=19.6488ms (max=1200ms) -
28.963415 Get Diagnostic Response Positive response was received. -
28.963415 Diagnostic response 0x54 -
28.963415 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
2. Wait 500 ms: None
29.463415 1 Waited for 500.000 ms -
3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x10" Expected: Positive response: Passed
29.463415 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x10 -
29.464905 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.48984ms (max=1000ms) -
29.464905 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x10 pass
29.482383 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.4778ms (max=1200ms) -
29.482383 Get Diagnostic Response Positive response was received. -
29.482383 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x10, 0x00 -
29.482383 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
4. Check FDC10 in response Expected: FDC10 equal 0: Passed
29.482383 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 0 -
29.482383 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 0 pass
pass
5. Wait 500 ms: None
29.982383 1 Waited for 500.000 ms -
6. For loop: Start value = 244, Stop value = 136, iterator-= 12 (For i=244..136, increment=-12)
6.1. For loop: Start value = 244, Stop value = 136, iterator-= 12 (For i=244..136, increment=-12; current i = 244)
6.1.1. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x10" Expected: Positive response: Passed
29.982383 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x10 -
29.984069 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.68619ms (max=1000ms) -
29.984069 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x10 pass
30.002506 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=18.4368ms (max=1200ms) -
30.002506 Get Diagnostic Response Positive response was received. -
30.002506 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x10, 0xE8 -
30.002506 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
6.1.2. Check FDC10 value Expected: FDC10 equal expected value: Failed
30.002506 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 244 -
30.002506 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 232 244 fail
fail
6.1.3. (In for loop)Wait 1s for the next FDC10 test period: None
31.002506 1 Waited for 1000.000 ms -
6.2. For loop: Start value = 244, Stop value = 136, iterator-= 12 (For i=244..136, increment=-12; current i = 232)
6.2.1. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x10" Expected: Positive response: Passed
31.002506 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x10 -
31.004118 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.61269ms (max=1000ms) -
31.004118 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x10 pass
31.022410 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=18.2912ms (max=1200ms) -
31.022410 Get Diagnostic Response Positive response was received. -
31.022410 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x10, 0xDC -
31.022410 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
6.2.2. Check FDC10 value Expected: FDC10 equal expected value: Failed
31.022410 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 232 -
31.022410 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 220 232 fail
fail
6.2.3. (In for loop)Wait 1s for the next FDC10 test period: None
32.022410 1 Waited for 1000.000 ms -
6.3. For loop: Start value = 244, Stop value = 136, iterator-= 12 (For i=244..136, increment=-12; current i = 220)
6.3.1. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x10" Expected: Positive response: Passed
32.022410 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x10 -
32.024008 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.59811ms (max=1000ms) -
32.024008 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x10 pass
32.042533 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=18.5253ms (max=1200ms) -
32.042533 Get Diagnostic Response Positive response was received. -
32.042533 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x10, 0xD0 -
32.042533 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
6.3.2. Check FDC10 value Expected: FDC10 equal expected value: Failed
32.042533 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 220 -
32.042533 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 208 220 fail
fail
6.3.3. (In for loop)Wait 1s for the next FDC10 test period: None
33.042533 1 Waited for 1000.000 ms -
6.4. For loop: Start value = 244, Stop value = 136, iterator-= 12 (For i=244..136, increment=-12; current i = 208)
6.4.1. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x10" Expected: Positive response: Passed
33.042533 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x10 -
33.044123 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.59013ms (max=1000ms) -
33.044123 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x10 pass
33.062384 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=18.2613ms (max=1200ms) -
33.062384 Get Diagnostic Response Positive response was received. -
33.062384 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x10, 0xC4 -
33.062384 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
6.4.2. Check FDC10 value Expected: FDC10 equal expected value: Failed
33.062384 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 208 -
33.062384 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 196 208 fail
fail
6.4.3. (In for loop)Wait 1s for the next FDC10 test period: None
34.062384 1 Waited for 1000.000 ms -
6.5. For loop: Start value = 244, Stop value = 136, iterator-= 12 (For i=244..136, increment=-12; current i = 196)
6.5.1. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x10" Expected: Positive response: Passed
34.062384 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x10 -
34.063960 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.57523ms (max=1000ms) -
34.063960 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x10 pass
34.082376 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=18.4166ms (max=1200ms) -
34.082376 Get Diagnostic Response Positive response was received. -
34.082376 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x10, 0xB8 -
34.082376 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
6.5.2. Check FDC10 value Expected: FDC10 equal expected value: Failed
34.082376 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 196 -
34.082376 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 184 196 fail
fail
6.5.3. (In for loop)Wait 1s for the next FDC10 test period: None
35.082376 1 Waited for 1000.000 ms -
6.6. For loop: Start value = 244, Stop value = 136, iterator-= 12 (For i=244..136, increment=-12; current i = 184)
6.6.1. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x10" Expected: Positive response: Passed
35.082376 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x10 -
35.084076 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.69989ms (max=1000ms) -
35.084076 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x10 pass
35.102371 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=18.2953ms (max=1200ms) -
35.102371 Get Diagnostic Response Positive response was received. -
35.102371 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x10, 0xAC -
35.102371 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
6.6.2. Check FDC10 value Expected: FDC10 equal expected value: Failed
35.102371 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 184 -
35.102371 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 172 184 fail
fail
6.6.3. (In for loop)Wait 1s for the next FDC10 test period: None
36.102371 1 Waited for 1000.000 ms -
6.7. For loop: Start value = 244, Stop value = 136, iterator-= 12 (For i=244..136, increment=-12; current i = 172)
6.7.1. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x10" Expected: Positive response: Passed
36.102371 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x10 -
36.103944 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.57225ms (max=1000ms) -
36.103944 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x10 pass
36.122359 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=18.415ms (max=1200ms) -
36.122359 Get Diagnostic Response Positive response was received. -
36.122359 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x10, 0xA0 -
36.122359 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
6.7.2. Check FDC10 value Expected: FDC10 equal expected value: Failed
36.122359 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 172 -
36.122359 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 160 172 fail
fail
6.7.3. (In for loop)Wait 1s for the next FDC10 test period: None
37.122359 1 Waited for 1000.000 ms -
6.8. For loop: Start value = 244, Stop value = 136, iterator-= 12 (For i=244..136, increment=-12; current i = 160)
6.8.1. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x10" Expected: Positive response: Passed
37.122359 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x10 -
37.124046 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.68716ms (max=1000ms) -
37.124046 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x10 pass
37.142345 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=18.2988ms (max=1200ms) -
37.142345 Get Diagnostic Response Positive response was received. -
37.142345 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x10, 0x94 -
37.142345 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
6.8.2. Check FDC10 value Expected: FDC10 equal expected value: Failed
37.142345 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 160 -
37.142345 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 148 160 fail
fail
6.8.3. (In for loop)Wait 1s for the next FDC10 test period: None
38.142345 1 Waited for 1000.000 ms -
6.9. For loop: Start value = 244, Stop value = 136, iterator-= 12 (For i=244..136, increment=-12; current i = 148)
6.9.1. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x10" Expected: Positive response: Passed
38.142345 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x10 -
38.144081 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.73627ms (max=1000ms) -
38.144081 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x10 pass
38.162329 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=18.2483ms (max=1200ms) -
38.162329 Get Diagnostic Response Positive response was received. -
38.162329 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x10, 0x88 -
38.162329 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
6.9.2. Check FDC10 value Expected: FDC10 equal expected value: Failed
38.162329 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 148 -
38.162329 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 136 148 fail
fail
6.9.3. (In for loop)Wait 1s for the next FDC10 test period: None
39.162329 1 Waited for 1000.000 ms -
6.10. For loop: Start value = 244, Stop value = 136, iterator-= 12 (For i=244..136, increment=-12; current i = 136)
6.10.1. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x10" Expected: Positive response: Passed
39.162329 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x10 -
39.163934 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.60502ms (max=1000ms) -
39.163934 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x10 pass
39.182323 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=18.3887ms (max=1200ms) -
39.182323 Get Diagnostic Response Positive response was received. -
39.182323 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x00, 0x10, 0x80 -
39.182323 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
6.10.2. Check FDC10 value Expected: FDC10 equal expected value: Failed
39.182323 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 136 -
39.182323 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 128 136 fail
fail
6.10.3. (In for loop)Wait 1s for the next FDC10 test period: None
40.182323 1 Waited for 1000.000 ms -
7. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x10" Expected: Positive response: Passed
40.182323 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x10 -
40.183845 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.52247ms (max=1000ms) -
40.183845 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x10 pass
40.202374 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=18.5283ms (max=1200ms) -
40.202374 Get Diagnostic Response Positive response was received. -
40.202374 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x00, 0x10, 0x80 -
40.202374 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
8. Check FDC10 value Expected: FDC10 equal expected value: Passed
40.202374 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 128 -
40.202374 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 128 128 pass
pass
9. Change the state of the relay, Expected: Park 1 button is pressed: Passed
40.202374 Change Relay State Relay vt2820_channel_6 - Relay 6 state was changed to PUSHED pass
10. Change the state of the relay, Expected: Park 2 button is pressed: Passed
40.202374 Change Relay State Relay vt2820_channel_7 - Relay 7 state was changed to PUSHED pass
11. Wait for close relay: None
40.207374 1 Waited for 5.000 ms -
12. Check that the SWMRiLvrDiagRiLvrDiag value has been set to 2 within 200s Expected: The signal has been set: Passed
220.270543 Resume reason Resumed on signal: CAN signal 'SWMRiLvrDiagRiLvrDiag' Elapsed time=180063ms (max=200000ms) -
220.270543 1
[−] Waited for occurrence of 1 value condition and signal updates.
Symbol Op. Reference value Actual Result
CAN signal 'SWMRiLvrDiagRiLvrDiag' == 2 2 pass
pass
13. For loop: Start value = 0, Stop value = 5, iterator+= 1 (For i=0..5, increment=1)
13.1. For loop: Start value = 0, Stop value = 5, iterator+= 1 (For i=0..5, increment=1; current i = 0)
13.1.1. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x10" Expected: Positive response: Passed
220.270543 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x10 -
220.272519 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.97586ms (max=1000ms) -
220.272519 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x10 pass
220.290976 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=18.4569ms (max=1200ms) -
220.290976 Get Diagnostic Response Positive response was received. -
220.290976 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x00, 0x10, 0x18 -
220.290976 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
13.1.2. Check FDC10 value Expected: FDC10 equal expected value: Failed
220.290976 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 128 -
220.290976 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 24 128 fail
fail
13.1.3. (In for loop) Wait 1s for the next FDC10 test period: None
221.290976 1 Waited for 1000.000 ms -
13.2. For loop: Start value = 0, Stop value = 5, iterator+= 1 (For i=0..5, increment=1; current i = 1)
13.2.1. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x10" Expected: Positive response: Passed
221.290976 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x10 -
221.292646 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.67044ms (max=1000ms) -
221.292646 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x10 pass
221.310979 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=18.3329ms (max=1200ms) -
221.310979 Get Diagnostic Response Positive response was received. -
221.310979 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x00, 0x10, 0x24 -
221.310979 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
13.2.2. Check FDC10 value Expected: FDC10 equal expected value: Failed
221.310979 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 128 -
221.310979 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 36 128 fail
fail
13.2.3. (In for loop) Wait 1s for the next FDC10 test period: None
222.310979 1 Waited for 1000.000 ms -
13.3. For loop: Start value = 0, Stop value = 5, iterator+= 1 (For i=0..5, increment=1; current i = 2)
13.3.1. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x10" Expected: Positive response: Passed
222.310979 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x10 -
222.312670 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.69064ms (max=1000ms) -
222.312670 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x10 pass
222.330970 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=18.2998ms (max=1200ms) -
222.330970 Get Diagnostic Response Positive response was received. -
222.330970 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x00, 0x10, 0x30 -
222.330970 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
13.3.2. Check FDC10 value Expected: FDC10 equal expected value: Failed
222.330970 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 128 -
222.330970 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 48 128 fail
fail
13.3.3. (In for loop) Wait 1s for the next FDC10 test period: None
223.330970 1 Waited for 1000.000 ms -
13.4. For loop: Start value = 0, Stop value = 5, iterator+= 1 (For i=0..5, increment=1; current i = 3)
13.4.1. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x10" Expected: Positive response: Passed
223.330970 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x10 -
223.332621 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.65161ms (max=1000ms) -
223.332621 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x10 pass
223.351010 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=18.3884ms (max=1200ms) -
223.351010 Get Diagnostic Response Positive response was received. -
223.351010 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x00, 0x10, 0x3C -
223.351010 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
13.4.2. Check FDC10 value Expected: FDC10 equal expected value: Failed
223.351010 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 128 -
223.351010 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 60 128 fail
fail
13.4.3. (In for loop) Wait 1s for the next FDC10 test period: None
224.351010 1 Waited for 1000.000 ms -
13.5. For loop: Start value = 0, Stop value = 5, iterator+= 1 (For i=0..5, increment=1; current i = 4)
13.5.1. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x10" Expected: Positive response: Passed
224.351010 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x10 -
224.352629 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.61941ms (max=1000ms) -
224.352629 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x10 pass
224.370962 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=18.3328ms (max=1200ms) -
224.370962 Get Diagnostic Response Positive response was received. -
224.370962 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x00, 0x10, 0x48 -
224.370962 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
13.5.2. Check FDC10 value Expected: FDC10 equal expected value: Failed
224.370962 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 128 -
224.370962 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 72 128 fail
fail
13.5.3. (In for loop) Wait 1s for the next FDC10 test period: None
225.370962 1 Waited for 1000.000 ms -
13.6. For loop: Start value = 0, Stop value = 5, iterator+= 1 (For i=0..5, increment=1; current i = 5)
13.6.1. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x10" Expected: Positive response: Passed
225.370962 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x10 -
225.372543 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.58108ms (max=1000ms) -
225.372543 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x10 pass
225.390957 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=18.4139ms (max=1200ms) -
225.390957 Get Diagnostic Response Positive response was received. -
225.390957 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x00, 0x10, 0x54 -
225.390957 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
13.6.2. Check FDC10 value Expected: FDC10 equal expected value: Failed
225.390957 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 128 -
225.390957 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 84 128 fail
fail
13.6.3. (In for loop) Wait 1s for the next FDC10 test period: None
226.390957 1 Waited for 1000.000 ms -
14. For loop: Start value = 12, Stop value = 120, iterator+= 12 (For i=12..120, increment=12)
14.1. For loop: Start value = 12, Stop value = 120, iterator+= 12 (For i=12..120, increment=12; current i = 12)
14.1.1. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x10" Expected: Positive response: Passed
226.390957 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x10 -
226.392596 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.63909ms (max=1000ms) -
226.392596 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x10 pass
226.410954 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=18.3584ms (max=1200ms) -
226.410954 Get Diagnostic Response Positive response was received. -
226.410954 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x00, 0x10, 0x60 -
226.410954 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
14.1.2. Check FDC10 value Expected: FDC10 equal expected value: Failed
226.410954 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 12 -
226.410954 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 96 12 fail
fail
14.1.3. (In for loop) Wait 1s for the next FDC10 test period: None
227.410954 1 Waited for 1000.000 ms -
14.2. For loop: Start value = 12, Stop value = 120, iterator+= 12 (For i=12..120, increment=12; current i = 24)
14.2.1. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x10" Expected: Positive response: Passed
227.410954 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x10 -
227.412517 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.56291ms (max=1000ms) -
227.412517 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x10 pass
227.430949 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=18.4318ms (max=1200ms) -
227.430949 Get Diagnostic Response Positive response was received. -
227.430949 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x00, 0x10, 0x6C -
227.430949 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
14.2.2. Check FDC10 value Expected: FDC10 equal expected value: Failed
227.430949 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 24 -
227.430949 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 108 24 fail
fail
14.2.3. (In for loop) Wait 1s for the next FDC10 test period: None
228.430949 1 Waited for 1000.000 ms -
14.3. For loop: Start value = 12, Stop value = 120, iterator+= 12 (For i=12..120, increment=12; current i = 36)
14.3.1. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x10" Expected: Positive response: Passed
228.430949 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x10 -
228.432517 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.56836ms (max=1000ms) -
228.432517 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x10 pass
228.450978 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=18.4604ms (max=1200ms) -
228.450978 Get Diagnostic Response Positive response was received. -
228.450978 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x00, 0x10, 0x78 -
228.450978 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
14.3.2. Check FDC10 value Expected: FDC10 equal expected value: Failed
228.450978 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 36 -
228.450978 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 120 36 fail
fail
14.3.3. (In for loop) Wait 1s for the next FDC10 test period: None
229.450978 1 Waited for 1000.000 ms -
14.4. For loop: Start value = 12, Stop value = 120, iterator+= 12 (For i=12..120, increment=12; current i = 48)
14.4.1. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x10" Expected: Positive response: Passed
229.450978 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x10 -
229.452577 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.59903ms (max=1000ms) -
229.452577 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x10 pass
229.470938 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=18.3613ms (max=1200ms) -
229.470938 Get Diagnostic Response Positive response was received. -
229.470938 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x2F, 0x10, 0x7F -
229.470938 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
14.4.2. Check FDC10 value Expected: FDC10 equal expected value: Failed
229.470938 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 48 -
229.470938 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 127 48 fail
fail
14.4.3. (In for loop) Wait 1s for the next FDC10 test period: None
230.470938 1 Waited for 1000.000 ms -
14.5. For loop: Start value = 12, Stop value = 120, iterator+= 12 (For i=12..120, increment=12; current i = 60)
14.5.1. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x10" Expected: Positive response: Passed
230.470938 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x10 -
230.472517 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.57872ms (max=1000ms) -
230.472517 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x10 pass
230.490922 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=18.4049ms (max=1200ms) -
230.490922 Get Diagnostic Response Positive response was received. -
230.490922 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x2F, 0x10, 0x7F -
230.490922 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
14.5.2. Check FDC10 value Expected: FDC10 equal expected value: Failed
230.490922 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 60 -
230.490922 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 127 60 fail
fail
14.5.3. (In for loop) Wait 1s for the next FDC10 test period: None
231.490922 1 Waited for 1000.000 ms -
14.6. For loop: Start value = 12, Stop value = 120, iterator+= 12 (For i=12..120, increment=12; current i = 72)
14.6.1. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x10" Expected: Positive response: Passed
231.490922 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x10 -
231.492476 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.55416ms (max=1000ms) -
231.492476 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x10 pass
231.510918 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=18.4419ms (max=1200ms) -
231.510918 Get Diagnostic Response Positive response was received. -
231.510918 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x2F, 0x10, 0x7F -
231.510918 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
14.6.2. Check FDC10 value Expected: FDC10 equal expected value: Failed
231.510918 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 72 -
231.510918 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 127 72 fail
fail
14.6.3. (In for loop) Wait 1s for the next FDC10 test period: None
232.510918 1 Waited for 1000.000 ms -
14.7. For loop: Start value = 12, Stop value = 120, iterator+= 12 (For i=12..120, increment=12; current i = 84)
14.7.1. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x10" Expected: Positive response: Passed
232.510918 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x10 -
232.512479 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.56175ms (max=1000ms) -
232.512479 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x10 pass
232.530914 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=18.4343ms (max=1200ms) -
232.530914 Get Diagnostic Response Positive response was received. -
232.530914 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x2F, 0x10, 0x7F -
232.530914 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
14.7.2. Check FDC10 value Expected: FDC10 equal expected value: Failed
232.530914 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 84 -
232.530914 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 127 84 fail
fail
14.7.3. (In for loop) Wait 1s for the next FDC10 test period: None
233.530914 1 Waited for 1000.000 ms -
14.8. For loop: Start value = 12, Stop value = 120, iterator+= 12 (For i=12..120, increment=12; current i = 96)
14.8.1. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x10" Expected: Positive response: Passed
233.530914 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x10 -
233.532476 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.56216ms (max=1000ms) -
233.532476 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x10 pass
233.550944 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=18.4679ms (max=1200ms) -
233.550944 Get Diagnostic Response Positive response was received. -
233.550944 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x2F, 0x10, 0x7F -
233.550944 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
14.8.2. Check FDC10 value Expected: FDC10 equal expected value: Failed
233.550944 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 96 -
233.550944 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 127 96 fail
fail
14.8.3. (In for loop) Wait 1s for the next FDC10 test period: None
234.550944 1 Waited for 1000.000 ms -
14.9. For loop: Start value = 12, Stop value = 120, iterator+= 12 (For i=12..120, increment=12; current i = 108)
14.9.1. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x10" Expected: Positive response: Passed
234.550944 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x10 -
234.552571 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.62694ms (max=1000ms) -
234.552571 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x10 pass
234.570913 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=18.3422ms (max=1200ms) -
234.570913 Get Diagnostic Response Positive response was received. -
234.570913 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x2F, 0x10, 0x7F -
234.570913 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
14.9.2. Check FDC10 value Expected: FDC10 equal expected value: Failed
234.570913 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 108 -
234.570913 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 127 108 fail
fail
14.9.3. (In for loop) Wait 1s for the next FDC10 test period: None
235.570913 1 Waited for 1000.000 ms -
14.10. For loop: Start value = 12, Stop value = 120, iterator+= 12 (For i=12..120, increment=12; current i = 120)
14.10.1. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x10" Expected: Positive response: Passed
235.570913 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x10 -
235.572477 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.56381ms (max=1000ms) -
235.572477 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x10 pass
235.590897 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=18.4204ms (max=1200ms) -
235.590897 Get Diagnostic Response Positive response was received. -
235.590897 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x2F, 0x10, 0x7F -
235.590897 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
14.10.2. Check FDC10 value Expected: FDC10 equal expected value: Failed
235.590897 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 120 -
235.590897 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 127 120 fail
fail
14.10.3. (In for loop) Wait 1s for the next FDC10 test period: None
236.590897 1 Waited for 1000.000 ms -
15. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x10" Expected: Positive response: Passed
236.590897 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x10 -
236.592373 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.47592ms (max=1000ms) -
236.592373 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x10 pass
236.610900 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=18.5272ms (max=1200ms) -
236.610900 Get Diagnostic Response Positive response was received. -
236.610900 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x2F, 0x10, 0x7F -
236.610900 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
16. Check FDC10 value Expected: FDC10 equal expected value: Passed
236.610900 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 127 -
236.610900 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 127 127 pass
pass
17. Change the state of the relay, Expected: Park 1 button not is pressed: Passed
236.610900 Change Relay State Relay vt2820_channel_6 - Relay 6 state was changed to RELEASED pass
18. Change the state of the relay, Expected: Park 2 button not is pressed: Passed
236.610900 Change Relay State Relay vt2820_channel_7 - Relay 7 state was changed to RELEASED pass
19. Wait for open relay: None
236.620900 1 Waited for 10.000 ms -
20. Wait 3s: None
239.620900 1 Waited for 3.000 s -
21. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x10" Expected: Positive response: Passed
239.620900 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x10 -
239.622311 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.41077ms (max=1000ms) -
239.622311 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x10 pass
239.640879 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=18.5684ms (max=1200ms) -
239.640879 Get Diagnostic Response Positive response was received. -
239.640879 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x2F, 0x10, 0xC4 -
239.640879 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
22. Check FDC10 value Expected: FDC10 equal 127 (in hex 0x7F): Failed
239.640879 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 127 -
239.640879 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 196 127 fail
fail
23. Wait 2s: None
241.640879 1 Waited for 2.000 s -
24. For loop: Start value = 244, Stop value = 136, iterator -= 12 (For i=244..136, increment=-12)
24.1. For loop: Start value = 244, Stop value = 136, iterator -= 12 (For i=244..136, increment=-12; current i = 244)
24.1.1. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x10" Expected: Positive response: Passed
241.640879 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x10 -
241.642511 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.6318ms (max=1000ms) -
241.642511 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x10 pass
241.660820 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=18.3084ms (max=1200ms) -
241.660820 Get Diagnostic Response Positive response was received. -
241.660820 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x2F, 0x10, 0xAC -
241.660820 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
24.1.2. Check FDC10 value Expected: FDC10 equal expected value: Failed
241.660820 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 244 -
241.660820 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 172 244 fail
fail
24.1.3. (In for loop) Wait 1s for the next FDC10 test period: None
242.660820 1 Waited for 1000.000 ms -
24.2. For loop: Start value = 244, Stop value = 136, iterator -= 12 (For i=244..136, increment=-12; current i = 232)
24.2.1. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x10" Expected: Positive response: Passed
242.660820 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x10 -
242.662357 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.53759ms (max=1000ms) -
242.662357 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x10 pass
242.680815 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=18.4578ms (max=1200ms) -
242.680815 Get Diagnostic Response Positive response was received. -
242.680815 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x2F, 0x10, 0xA0 -
242.680815 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
24.2.2. Check FDC10 value Expected: FDC10 equal expected value: Failed
242.680815 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 232 -
242.680815 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 160 232 fail
fail
24.2.3. (In for loop) Wait 1s for the next FDC10 test period: None
243.680815 1 Waited for 1000.000 ms -
24.3. For loop: Start value = 244, Stop value = 136, iterator -= 12 (For i=244..136, increment=-12; current i = 220)
24.3.1. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x10" Expected: Positive response: Passed
243.680815 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x10 -
243.682345 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.53006ms (max=1000ms) -
243.682345 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x10 pass
243.700820 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=18.4749ms (max=1200ms) -
243.700820 Get Diagnostic Response Positive response was received. -
243.700820 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x2F, 0x10, 0x94 -
243.700820 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
24.3.2. Check FDC10 value Expected: FDC10 equal expected value: Failed
243.700820 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 220 -
243.700820 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 148 220 fail
fail
24.3.3. (In for loop) Wait 1s for the next FDC10 test period: None
244.700820 1 Waited for 1000.000 ms -
24.4. For loop: Start value = 244, Stop value = 136, iterator -= 12 (For i=244..136, increment=-12; current i = 208)
24.4.1. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x10" Expected: Positive response: Passed
244.700820 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x10 -
244.702357 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.53658ms (max=1000ms) -
244.702357 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x10 pass
244.720850 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=18.4933ms (max=1200ms) -
244.720850 Get Diagnostic Response Positive response was received. -
244.720850 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x2F, 0x10, 0x88 -
244.720850 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
24.4.2. Check FDC10 value Expected: FDC10 equal expected value: Failed
244.720850 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 208 -
244.720850 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 136 208 fail
fail
24.4.3. (In for loop) Wait 1s for the next FDC10 test period: None
245.720850 1 Waited for 1000.000 ms -
24.5. For loop: Start value = 244, Stop value = 136, iterator -= 12 (For i=244..136, increment=-12; current i = 196)
24.5.1. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x10" Expected: Positive response: Passed
245.720850 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x10 -
245.722393 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.54287ms (max=1000ms) -
245.722393 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x10 pass
245.740803 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=18.4103ms (max=1200ms) -
245.740803 Get Diagnostic Response Positive response was received. -
245.740803 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x2E, 0x10, 0x80 -
245.740803 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
24.5.2. Check FDC10 value Expected: FDC10 equal expected value: Failed
245.740803 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 196 -
245.740803 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 128 196 fail
fail
24.5.3. (In for loop) Wait 1s for the next FDC10 test period: None
246.740803 1 Waited for 1000.000 ms -
24.6. For loop: Start value = 244, Stop value = 136, iterator -= 12 (For i=244..136, increment=-12; current i = 184)
24.6.1. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x10" Expected: Positive response: Passed
246.740803 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x10 -
246.742483 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.68011ms (max=1000ms) -
246.742483 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x10 pass
246.760796 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=18.3129ms (max=1200ms) -
246.760796 Get Diagnostic Response Positive response was received. -
246.760796 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x2E, 0x10, 0x80 -
246.760796 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
24.6.2. Check FDC10 value Expected: FDC10 equal expected value: Failed
246.760796 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 184 -
246.760796 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 128 184 fail
fail
24.6.3. (In for loop) Wait 1s for the next FDC10 test period: None
247.760796 1 Waited for 1000.000 ms -
24.7. For loop: Start value = 244, Stop value = 136, iterator -= 12 (For i=244..136, increment=-12; current i = 172)
24.7.1. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x10" Expected: Positive response: Passed
247.760796 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x10 -
247.762347 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.55117ms (max=1000ms) -
247.762347 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x10 pass
247.780794 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=18.4473ms (max=1200ms) -
247.780794 Get Diagnostic Response Positive response was received. -
247.780794 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x2E, 0x10, 0x80 -
247.780794 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
24.7.2. Check FDC10 value Expected: FDC10 equal expected value: Failed
247.780794 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 172 -
247.780794 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 128 172 fail
fail
24.7.3. (In for loop) Wait 1s for the next FDC10 test period: None
248.780794 1 Waited for 1000.000 ms -
24.8. For loop: Start value = 244, Stop value = 136, iterator -= 12 (For i=244..136, increment=-12; current i = 160)
24.8.1. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x10" Expected: Positive response: Passed
248.780794 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x10 -
248.782339 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.5447ms (max=1000ms) -
248.782339 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x10 pass
248.800792 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=18.4525ms (max=1200ms) -
248.800792 Get Diagnostic Response Positive response was received. -
248.800792 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x2E, 0x10, 0x80 -
248.800792 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
24.8.2. Check FDC10 value Expected: FDC10 equal expected value: Failed
248.800792 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 160 -
248.800792 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 128 160 fail
fail
24.8.3. (In for loop) Wait 1s for the next FDC10 test period: None
249.800792 1 Waited for 1000.000 ms -
24.9. For loop: Start value = 244, Stop value = 136, iterator -= 12 (For i=244..136, increment=-12; current i = 148)
24.9.1. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x10" Expected: Positive response: Passed
249.800792 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x10 -
249.802375 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.58363ms (max=1000ms) -
249.802375 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x10 pass
249.820823 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=18.4478ms (max=1200ms) -
249.820823 Get Diagnostic Response Positive response was received. -
249.820823 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x2E, 0x10, 0x80 -
249.820823 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
24.9.2. Check FDC10 value Expected: FDC10 equal expected value: Failed
249.820823 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 148 -
249.820823 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 128 148 fail
fail
24.9.3. (In for loop) Wait 1s for the next FDC10 test period: None
250.820823 1 Waited for 1000.000 ms -
24.10. For loop: Start value = 244, Stop value = 136, iterator -= 12 (For i=244..136, increment=-12; current i = 136)
24.10.1. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x10" Expected: Positive response: Passed
250.820823 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x10 -
250.822353 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.52995ms (max=1000ms) -
250.822353 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x10 pass
250.840776 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=18.4224ms (max=1200ms) -
250.840776 Get Diagnostic Response Positive response was received. -
250.840776 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x2E, 0x10, 0x80 -
250.840776 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
24.10.2. Check FDC10 value Expected: FDC10 equal expected value: Failed
250.840776 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 136 -
250.840776 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 128 136 fail
fail
24.10.3. (In for loop) Wait 1s for the next FDC10 test period: None
251.840776 1 Waited for 1000.000 ms -
25. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x10" Expected: Positive response: Passed
251.840776 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x10 -
251.842312 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.53673ms (max=1000ms) -
251.842312 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x10 pass
251.860773 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=18.4604ms (max=1200ms) -
251.860773 Get Diagnostic Response Positive response was received. -
251.860773 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x2E, 0x10, 0x80 -
251.860773 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
26. Check FDC10 value Expected: FDC10 equal expected value: Passed
251.860773 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 128 -
251.860773 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 128 128 pass
pass
Completion of Test Case
Timestamp Test Step Description Result
1. Wait 500ms: None
252.360773 1 Waited for 500.000 ms -
2. Send diagnostic request "Clear Diagnostic Information" Expected: Positive response: Passed
252.362054 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.28178ms (max=1000ms) -
252.362054 Clear Diagnostic Information Request Clear Diagnostic Information was succesfully transmitted. -
252.381782 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=19.7278ms (max=1200ms) -
252.381782 Get Diagnostic Response Positive response was received. -
252.381782 Diagnostic response 0x54 -
252.381782 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
252.381782 VT System Cards Configuration General-Purpose Relay Module - M2_VT2820 -
3. Change the state of the relay, Expected: VCC line connected to DUT: Passed
252.381782 Change Relay State Relay vt2820_channel_13 - Relay 13 state was changed to RELEASED pass
4. Change the state of the relay, Expected: GND line connected to DUT: Passed
252.381782 Change Relay State Relay vt2820_channel_14 - Relay 14 state was changed to RELEASED pass
5. Set the supply voltage of the DUT, Expected: Voltage = 12.0 V: Passed
5.1. VTS_Set_Power_Supply_Voltage_RangeZeroTo28V: Passed
252.381782 Set power supply voltage Voltage set properly to 0.000000 V on vt2816_13 channel pass
6. Wait for configuration to be set: None
252.481782 1 Waited for 100.000 (setup_time_1) ms -
[−] 1.3.2 B183F2A - OCC 1 Operation cycle since last failed: Failed
Test case begin: 2024-06-19 14:57:56 (logging timestamp 252.481782)
Test case end: 2024-06-19 15:15:30 (logging timestamp 1305.908343)

Link (managed by: vTESTstudio Traceability): REQ-90115v4 Support for Operation Cycle Counter 1 - Operation cycle since last failed

Link (managed by: vTESTstudio Traceability): DTC 17 - Right Stalk General Signal Failures Signal Stuck In Range

Attributes
Safety Level: QM
Priority: Normal
Type: Automated
[expand test steps] [collapse test steps]
Preparation of Test Case
Timestamp Test Step Description Result
252.481782 VT System Cards Configuration General-Purpose Relay Module - M2_VT2820 -
252.481782 VT System Cards Configuration General-Purpose Analog I/O Module - M4_VT2816 -
252.481782 VT System Cards Configuration General-Purpose Digital I/O Module - M5_VT2848 -
252.481782 VT System Cards Configuration Network Module - M1_VT6204 -
252.481782 VT System Cards Configuration Serial Interface Module - M6_VT2710 -
252.481782 VT System Cards Configuration General-Purpose Relay Module - M2_VT2820 -
1. Change the state of the relay, Expected: VCC line connected to DUT: Passed
252.481782 Change Relay State Relay vt2820_channel_13 - Relay 13 state was changed to PUSHED pass
2. Change the state of the relay, Expected: GND line connected to DUT: Passed
252.481782 Change Relay State Relay vt2820_channel_14 - Relay 14 state was changed to PUSHED pass
3. Set the supply voltage of the DUT, Expected: Voltage = 12.0 V: Passed
3.1. VTS_Set_Power_Supply_Voltage_RangeZeroTo28V: Passed
252.481782 Set power supply voltage Voltage set properly to 12.000000 V on vt2816_13 channel pass
4. Wait for configuration to be set: None
252.581782 1 Waited for 100.000 (setup_time_1) ms -
5. Wait for the diagnostics to start: None
254.981782 1 Waited for 2400.000 (diagnostic_start_time) ms -
Main Part of Test Case
Timestamp Test Step Description Result
1. Send diagnostic request "Clear Diagnostic Information" Expected: Positive response: Passed
254.983036 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.25419ms (max=1000ms) -
254.983036 Clear Diagnostic Information Request Clear Diagnostic Information was succesfully transmitted. -
254.996935 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.8991ms (max=1200ms) -
254.996935 Get Diagnostic Response Positive response was received. -
254.996935 Diagnostic response 0x54 -
254.996935 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
2. Wait for TRC EN: None
257.496935 1 Waited for 2500.000 ms -
3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
257.496935 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
257.498356 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.42066ms (max=1000ms) -
257.498356 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
257.515623 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.2673ms (max=1200ms) -
257.515623 Get Diagnostic Response Positive response was received. -
257.515623 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50 -
257.515623 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
4. Check response length Expected: Response length of 6 bytes (data is not available): Passed
257.515623 Check diagnostic response length Check if length of diagnostic response equals 6 bytes. -
257.515623 Compare values
[−] Check diagnostic response length
Symbol Op. Reference value Actual Result
Diagnostic response length == 6 6 pass
pass
5. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Failed
257.515623 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
257.518125 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=2.50186ms (max=1000ms) -
257.518125 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
257.668125 Resume reason Resumed on Communication error with 'SWM' Elapsed time=150ms (max=1200ms) -
257.668125 Get Diagnostic Response No diagnostic response was received. -
257.668125 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == no response positive response fail
fail
6. Check OCC1 value Expected: OCC1 equal expected value: Failed
257.668125 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 0 -
257.668125 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 0
byte_index = 7
fail
7. Wait: None
257.678125 1 Waited for 10.000 ms -
8. Change the state of the relay, Expected: Park 1 button is pressed: Passed
257.678125 Change Relay State Relay vt2820_channel_6 - Relay 6 state was changed to PUSHED pass
9. Change the state of the relay, Expected: Park 2 button is pressed: Passed
257.678125 Change Relay State Relay vt2820_channel_7 - Relay 7 state was changed to PUSHED pass
10. Wait for close relay: None
257.683125 1 Waited for 5.000 ms -
11. Check that the SWMRiLvrDiagRiLvrDiag value has been set to 2 within 200s Expected: The signal has been set: Passed
437.759674 Resume reason Resumed on signal: CAN signal 'SWMRiLvrDiagRiLvrDiag' Elapsed time=180077ms (max=200000ms) -
437.759674 1
[−] Waited for occurrence of 1 value condition and signal updates.
Symbol Op. Reference value Actual Result
CAN signal 'SWMRiLvrDiagRiLvrDiag' == 2 2 pass
pass
12. Wait for 16s until the DTC reached TestFailed Limit : None
453.759674 1 Waited for 16.000 s -
13. Change the state of the relay, Expected: Park 1 button not is pressed: Passed
453.759674 Change Relay State Relay vt2820_channel_6 - Relay 6 state was changed to RELEASED pass
14. Change the state of the relay, Expected: Park 2 button not is pressed: Passed
453.759674 Change Relay State Relay vt2820_channel_7 - Relay 7 state was changed to RELEASED pass
15. Wait for open relay: None
453.769674 1 Waited for 10.000 ms -
16. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
453.769674 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
453.771256 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.58258ms (max=1000ms) -
453.771256 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
453.784942 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.6857ms (max=1200ms) -
453.784942 Get Diagnostic Response Positive response was received. -
453.784942 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x2F, 0x01, 0x00 -
453.784942 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
17. Check OCC1 value Expected: OCC1 equal expected value: Passed
453.784942 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 0 -
453.784942 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 0 pass
pass
18. Wait: None
453.794942 1 Waited for 10.000 ms -
19. Wait 10ms: None
453.804942 1 Waited for 10.000 ms -
20. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1)
20.1. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 1)
20.1.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
453.804942 Diagnostic request 0x11, 0x01 -
453.806318 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.37602ms (max=1000ms) -
453.806318 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
453.814890 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.57156ms (max=1200ms) -
453.814890 Get Diagnostic Response Positive response was received. -
453.814890 Diagnostic response 0x51, 0x01 -
453.814890 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.1.2. (In for loop)Wait for the diagnostics to start: None
456.214890 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.1.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
456.214890 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
456.216372 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.48245ms (max=1000ms) -
456.216372 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
456.230144 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.7715ms (max=1200ms) -
456.230144 Get Diagnostic Response Positive response was received. -
456.230144 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
456.230144 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.1.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
456.230144 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 1 -
456.230144 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.1.5. Wait: None
456.240144 1 Waited for 10.000 ms -
20.1.6. Wait 10ms: None
456.250144 1 Waited for 10.000 ms -
20.2. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 2)
20.2.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
456.250144 Diagnostic request 0x11, 0x01 -
456.251492 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.34858ms (max=1000ms) -
456.251492 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
456.260196 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.70408ms (max=1200ms) -
456.260196 Get Diagnostic Response Positive response was received. -
456.260196 Diagnostic response 0x51, 0x01 -
456.260196 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.2.2. (In for loop)Wait for the diagnostics to start: None
458.660196 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.2.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
458.660196 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
458.661643 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.44711ms (max=1000ms) -
458.661643 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
458.675445 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.8015ms (max=1200ms) -
458.675445 Get Diagnostic Response Positive response was received. -
458.675445 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
458.675445 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.2.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
458.675445 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 2 -
458.675445 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.2.5. Wait: None
458.685445 1 Waited for 10.000 ms -
20.2.6. Wait 10ms: None
458.695445 1 Waited for 10.000 ms -
20.3. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 3)
20.3.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
458.695445 Diagnostic request 0x11, 0x01 -
458.696935 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.49055ms (max=1000ms) -
458.696935 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
458.705497 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.56155ms (max=1200ms) -
458.705497 Get Diagnostic Response Positive response was received. -
458.705497 Diagnostic response 0x51, 0x01 -
458.705497 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.3.2. (In for loop)Wait for the diagnostics to start: None
461.105497 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.3.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
461.105497 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
461.106988 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.49083ms (max=1000ms) -
461.106988 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
461.120775 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.7875ms (max=1200ms) -
461.120775 Get Diagnostic Response Positive response was received. -
461.120775 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
461.120775 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.3.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
461.120775 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 3 -
461.120775 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.3.5. Wait: None
461.130775 1 Waited for 10.000 ms -
20.3.6. Wait 10ms: None
461.140775 1 Waited for 10.000 ms -
20.4. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 4)
20.4.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
461.140775 Diagnostic request 0x11, 0x01 -
461.142200 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.42459ms (max=1000ms) -
461.142200 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
461.150825 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.62553ms (max=1200ms) -
461.150825 Get Diagnostic Response Positive response was received. -
461.150825 Diagnostic response 0x51, 0x01 -
461.150825 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.4.2. (In for loop)Wait for the diagnostics to start: None
463.550825 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.4.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
463.550825 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
463.552305 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.47934ms (max=1000ms) -
463.552305 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
463.566048 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.7435ms (max=1200ms) -
463.566048 Get Diagnostic Response Positive response was received. -
463.566048 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
463.566048 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.4.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
463.566048 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 4 -
463.566048 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.4.5. Wait: None
463.576048 1 Waited for 10.000 ms -
20.4.6. Wait 10ms: None
463.586048 1 Waited for 10.000 ms -
20.5. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 5)
20.5.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
463.586048 Diagnostic request 0x11, 0x01 -
463.587413 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.36461ms (max=1000ms) -
463.587413 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
463.596106 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.69353ms (max=1200ms) -
463.596106 Get Diagnostic Response Positive response was received. -
463.596106 Diagnostic response 0x51, 0x01 -
463.596106 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.5.2. (In for loop)Wait for the diagnostics to start: None
465.996106 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.5.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
465.996106 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
465.997527 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.42034ms (max=1000ms) -
465.997527 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
466.011371 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.8439ms (max=1200ms) -
466.011371 Get Diagnostic Response Positive response was received. -
466.011371 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
466.011371 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.5.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
466.011371 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 5 -
466.011371 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.5.5. Wait: None
466.021371 1 Waited for 10.000 ms -
20.5.6. Wait 10ms: None
466.031371 1 Waited for 10.000 ms -
20.6. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 6)
20.6.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
466.031371 Diagnostic request 0x11, 0x01 -
466.032727 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.35656ms (max=1000ms) -
466.032727 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
466.041421 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.69353ms (max=1200ms) -
466.041421 Get Diagnostic Response Positive response was received. -
466.041421 Diagnostic response 0x51, 0x01 -
466.041421 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.6.2. (In for loop)Wait for the diagnostics to start: None
468.441421 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.6.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
468.441421 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
468.443166 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.74505ms (max=1000ms) -
468.443166 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
468.456651 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.4855ms (max=1200ms) -
468.456651 Get Diagnostic Response Positive response was received. -
468.456651 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
468.456651 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.6.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
468.456651 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 6 -
468.456651 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.6.5. Wait: None
468.466651 1 Waited for 10.000 ms -
20.6.6. Wait 10ms: None
468.476651 1 Waited for 10.000 ms -
20.7. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 7)
20.7.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
468.476651 Diagnostic request 0x11, 0x01 -
468.477990 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.33858ms (max=1000ms) -
468.477990 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
468.486702 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.71259ms (max=1200ms) -
468.486702 Get Diagnostic Response Positive response was received. -
468.486702 Diagnostic response 0x51, 0x01 -
468.486702 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.7.2. (In for loop)Wait for the diagnostics to start: None
470.886702 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.7.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
470.886702 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
470.888174 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.47184ms (max=1000ms) -
470.888174 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
470.901882 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.7075ms (max=1200ms) -
470.901882 Get Diagnostic Response Positive response was received. -
470.901882 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
470.901882 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.7.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
470.901882 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 7 -
470.901882 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.7.5. Wait: None
470.911882 1 Waited for 10.000 ms -
20.7.6. Wait 10ms: None
470.921882 1 Waited for 10.000 ms -
20.8. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 8)
20.8.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
470.921882 Diagnostic request 0x11, 0x01 -
470.923268 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.38656ms (max=1000ms) -
470.923268 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
470.931938 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.66956ms (max=1200ms) -
470.931938 Get Diagnostic Response Positive response was received. -
470.931938 Diagnostic response 0x51, 0x01 -
470.931938 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.8.2. (In for loop)Wait for the diagnostics to start: None
473.331938 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.8.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
473.331938 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
473.333365 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.42741ms (max=1000ms) -
473.333365 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
473.347149 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.7835ms (max=1200ms) -
473.347149 Get Diagnostic Response Positive response was received. -
473.347149 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
473.347149 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.8.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
473.347149 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 8 -
473.347149 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.8.5. Wait: None
473.357149 1 Waited for 10.000 ms -
20.8.6. Wait 10ms: None
473.367149 1 Waited for 10.000 ms -
20.9. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 9)
20.9.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
473.367149 Diagnostic request 0x11, 0x01 -
473.368413 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.26456ms (max=1000ms) -
473.368413 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
473.377203 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.78953ms (max=1200ms) -
473.377203 Get Diagnostic Response Positive response was received. -
473.377203 Diagnostic response 0x51, 0x01 -
473.377203 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.9.2. (In for loop)Wait for the diagnostics to start: None
475.777203 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.9.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
475.777203 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
475.778561 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.35831ms (max=1000ms) -
475.778561 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
475.792435 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.8735ms (max=1200ms) -
475.792435 Get Diagnostic Response Positive response was received. -
475.792435 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
475.792435 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.9.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
475.792435 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 9 -
475.792435 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.9.5. Wait: None
475.802435 1 Waited for 10.000 ms -
20.9.6. Wait 10ms: None
475.812435 1 Waited for 10.000 ms -
20.10. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 10)
20.10.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
475.812435 Diagnostic request 0x11, 0x01 -
475.813781 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.34666ms (max=1000ms) -
475.813781 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
475.822491 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.70953ms (max=1200ms) -
475.822491 Get Diagnostic Response Positive response was received. -
475.822491 Diagnostic response 0x51, 0x01 -
475.822491 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.10.2. (In for loop)Wait for the diagnostics to start: None
478.222491 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.10.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
478.222491 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
478.224003 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.51233ms (max=1000ms) -
478.224003 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
478.237805 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.8015ms (max=1200ms) -
478.237805 Get Diagnostic Response Positive response was received. -
478.237805 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
478.237805 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.10.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
478.237805 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 10 -
478.237805 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.10.5. Wait: None
478.247805 1 Waited for 10.000 ms -
20.10.6. Wait 10ms: None
478.257805 1 Waited for 10.000 ms -
20.11. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 11)
20.11.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
478.257805 Diagnostic request 0x11, 0x01 -
478.259167 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.36256ms (max=1000ms) -
478.259167 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
478.267860 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.69253ms (max=1200ms) -
478.267860 Get Diagnostic Response Positive response was received. -
478.267860 Diagnostic response 0x51, 0x01 -
478.267860 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.11.2. (In for loop)Wait for the diagnostics to start: None
480.667860 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.11.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
480.667860 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
480.669305 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.44539ms (max=1000ms) -
480.669305 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
480.683033 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.7275ms (max=1200ms) -
480.683033 Get Diagnostic Response Positive response was received. -
480.683033 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
480.683033 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.11.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
480.683033 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 11 -
480.683033 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.11.5. Wait: None
480.693033 1 Waited for 10.000 ms -
20.11.6. Wait 10ms: None
480.703033 1 Waited for 10.000 ms -
20.12. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 12)
20.12.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
480.703033 Diagnostic request 0x11, 0x01 -
480.704385 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.35256ms (max=1000ms) -
480.704385 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
480.713089 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.70358ms (max=1200ms) -
480.713089 Get Diagnostic Response Positive response was received. -
480.713089 Diagnostic response 0x51, 0x01 -
480.713089 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.12.2. (In for loop)Wait for the diagnostics to start: None
483.113089 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.12.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
483.113089 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
483.114512 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.4227ms (max=1000ms) -
483.114512 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
483.128283 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.7715ms (max=1200ms) -
483.128283 Get Diagnostic Response Positive response was received. -
483.128283 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
483.128283 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.12.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
483.128283 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 12 -
483.128283 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.12.5. Wait: None
483.138283 1 Waited for 10.000 ms -
20.12.6. Wait 10ms: None
483.148283 1 Waited for 10.000 ms -
20.13. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 13)
20.13.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
483.148283 Diagnostic request 0x11, 0x01 -
483.149754 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.47056ms (max=1000ms) -
483.149754 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
483.158335 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.58158ms (max=1200ms) -
483.158335 Get Diagnostic Response Positive response was received. -
483.158335 Diagnostic response 0x51, 0x01 -
483.158335 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.13.2. (In for loop)Wait for the diagnostics to start: None
485.558335 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.13.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
485.558335 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
485.559822 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.48714ms (max=1000ms) -
485.559822 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
485.573408 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.5855ms (max=1200ms) -
485.573408 Get Diagnostic Response Positive response was received. -
485.573408 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
485.573408 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.13.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
485.573408 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 13 -
485.573408 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.13.5. Wait: None
485.583408 1 Waited for 10.000 ms -
20.13.6. Wait 10ms: None
485.593408 1 Waited for 10.000 ms -
20.14. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 14)
20.14.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
485.593408 Diagnostic request 0x11, 0x01 -
485.594864 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.45658ms (max=1000ms) -
485.594864 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
485.603522 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.65759ms (max=1200ms) -
485.603522 Get Diagnostic Response Positive response was received. -
485.603522 Diagnostic response 0x51, 0x01 -
485.603522 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.14.2. (In for loop)Wait for the diagnostics to start: None
488.003522 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.14.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
488.003522 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
488.005200 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.67834ms (max=1000ms) -
488.005200 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
488.018594 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.3935ms (max=1200ms) -
488.018594 Get Diagnostic Response Positive response was received. -
488.018594 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
488.018594 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.14.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
488.018594 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 14 -
488.018594 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.14.5. Wait: None
488.028594 1 Waited for 10.000 ms -
20.14.6. Wait 10ms: None
488.038594 1 Waited for 10.000 ms -
20.15. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 15)
20.15.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
488.038594 Diagnostic request 0x11, 0x01 -
488.039968 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.37459ms (max=1000ms) -
488.039968 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
488.048646 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.67752ms (max=1200ms) -
488.048646 Get Diagnostic Response Positive response was received. -
488.048646 Diagnostic response 0x51, 0x01 -
488.048646 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.15.2. (In for loop)Wait for the diagnostics to start: None
490.448646 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.15.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
490.448646 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
490.450216 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.57048ms (max=1000ms) -
490.450216 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
490.463830 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.6135ms (max=1200ms) -
490.463830 Get Diagnostic Response Positive response was received. -
490.463830 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
490.463830 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.15.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
490.463830 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 15 -
490.463830 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.15.5. Wait: None
490.473830 1 Waited for 10.000 ms -
20.15.6. Wait 10ms: None
490.483830 1 Waited for 10.000 ms -
20.16. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 16)
20.16.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
490.483830 Diagnostic request 0x11, 0x01 -
490.485099 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.26859ms (max=1000ms) -
490.485099 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
490.493882 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.78352ms (max=1200ms) -
490.493882 Get Diagnostic Response Positive response was received. -
490.493882 Diagnostic response 0x51, 0x01 -
490.493882 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.16.2. (In for loop)Wait for the diagnostics to start: None
492.893882 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.16.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
492.893882 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
492.895291 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.40848ms (max=1000ms) -
492.895291 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
492.909004 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.7135ms (max=1200ms) -
492.909004 Get Diagnostic Response Positive response was received. -
492.909004 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
492.909004 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.16.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
492.909004 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 16 -
492.909004 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.16.5. Wait: None
492.919004 1 Waited for 10.000 ms -
20.16.6. Wait 10ms: None
492.929004 1 Waited for 10.000 ms -
20.17. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 17)
20.17.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
492.929004 Diagnostic request 0x11, 0x01 -
492.930343 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.33856ms (max=1000ms) -
492.930343 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
492.939058 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.71506ms (max=1200ms) -
492.939058 Get Diagnostic Response Positive response was received. -
492.939058 Diagnostic response 0x51, 0x01 -
492.939058 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.17.2. (In for loop)Wait for the diagnostics to start: None
495.339058 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.17.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
495.339058 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
495.340485 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.4275ms (max=1000ms) -
495.340485 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
495.354243 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.7575ms (max=1200ms) -
495.354243 Get Diagnostic Response Positive response was received. -
495.354243 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
495.354243 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.17.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
495.354243 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 17 -
495.354243 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.17.5. Wait: None
495.364243 1 Waited for 10.000 ms -
20.17.6. Wait 10ms: None
495.374243 1 Waited for 10.000 ms -
20.18. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 18)
20.18.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
495.374243 Diagnostic request 0x11, 0x01 -
495.375661 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.41858ms (max=1000ms) -
495.375661 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
495.384295 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.63356ms (max=1200ms) -
495.384295 Get Diagnostic Response Positive response was received. -
495.384295 Diagnostic response 0x51, 0x01 -
495.384295 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.18.2. (In for loop)Wait for the diagnostics to start: None
497.784295 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.18.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
497.784295 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
497.785906 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.61098ms (max=1000ms) -
497.785906 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
497.799395 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.4895ms (max=1200ms) -
497.799395 Get Diagnostic Response Positive response was received. -
497.799395 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
497.799395 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.18.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
497.799395 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 18 -
497.799395 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.18.5. Wait: None
497.809395 1 Waited for 10.000 ms -
20.18.6. Wait 10ms: None
497.819395 1 Waited for 10.000 ms -
20.19. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 19)
20.19.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
497.819395 Diagnostic request 0x11, 0x01 -
497.820986 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.59061ms (max=1000ms) -
497.820986 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
497.829443 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.45755ms (max=1200ms) -
497.829443 Get Diagnostic Response Positive response was received. -
497.829443 Diagnostic response 0x51, 0x01 -
497.829443 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.19.2. (In for loop)Wait for the diagnostics to start: None
500.229443 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.19.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
500.229443 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
500.231080 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.63688ms (max=1000ms) -
500.231080 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
500.244492 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.4115ms (max=1200ms) -
500.244492 Get Diagnostic Response Positive response was received. -
500.244492 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
500.244492 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.19.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
500.244492 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 19 -
500.244492 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.19.5. Wait: None
500.254492 1 Waited for 10.000 ms -
20.19.6. Wait 10ms: None
500.264492 1 Waited for 10.000 ms -
20.20. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 20)
20.20.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
500.264492 Diagnostic request 0x11, 0x01 -
500.265990 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.49858ms (max=1000ms) -
500.265990 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
500.274548 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.55753ms (max=1200ms) -
500.274548 Get Diagnostic Response Positive response was received. -
500.274548 Diagnostic response 0x51, 0x01 -
500.274548 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.20.2. (In for loop)Wait for the diagnostics to start: None
502.674548 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.20.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
502.674548 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
502.676011 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.46305ms (max=1000ms) -
502.676011 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
502.689652 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.6415ms (max=1200ms) -
502.689652 Get Diagnostic Response Positive response was received. -
502.689652 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
502.689652 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.20.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
502.689652 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 20 -
502.689652 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.20.5. Wait: None
502.699652 1 Waited for 10.000 ms -
20.20.6. Wait 10ms: None
502.709652 1 Waited for 10.000 ms -
20.21. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 21)
20.21.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
502.709652 Diagnostic request 0x11, 0x01 -
502.711105 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.45256ms (max=1000ms) -
502.711105 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
502.719709 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.60361ms (max=1200ms) -
502.719709 Get Diagnostic Response Positive response was received. -
502.719709 Diagnostic response 0x51, 0x01 -
502.719709 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.21.2. (In for loop)Wait for the diagnostics to start: None
505.119709 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.21.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
505.119709 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
505.121319 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.61009ms (max=1000ms) -
505.121319 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
505.134850 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.5315ms (max=1200ms) -
505.134850 Get Diagnostic Response Positive response was received. -
505.134850 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
505.134850 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.21.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
505.134850 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 21 -
505.134850 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.21.5. Wait: None
505.144850 1 Waited for 10.000 ms -
20.21.6. Wait 10ms: None
505.154850 1 Waited for 10.000 ms -
20.22. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 22)
20.22.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
505.154850 Diagnostic request 0x11, 0x01 -
505.156225 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.37461ms (max=1000ms) -
505.156225 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
505.164903 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.67856ms (max=1200ms) -
505.164903 Get Diagnostic Response Positive response was received. -
505.164903 Diagnostic response 0x51, 0x01 -
505.164903 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.22.2. (In for loop)Wait for the diagnostics to start: None
507.564903 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.22.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
507.564903 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
507.566345 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.44124ms (max=1000ms) -
507.566345 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
507.580082 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.7375ms (max=1200ms) -
507.580082 Get Diagnostic Response Positive response was received. -
507.580082 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
507.580082 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.22.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
507.580082 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 22 -
507.580082 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.22.5. Wait: None
507.590082 1 Waited for 10.000 ms -
20.22.6. Wait 10ms: None
507.600082 1 Waited for 10.000 ms -
20.23. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 23)
20.23.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
507.600082 Diagnostic request 0x11, 0x01 -
507.601563 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.48095ms (max=1000ms) -
507.601563 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
507.610134 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.57056ms (max=1200ms) -
507.610134 Get Diagnostic Response Positive response was received. -
507.610134 Diagnostic response 0x51, 0x01 -
507.610134 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.23.2. (In for loop)Wait for the diagnostics to start: None
510.010134 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.23.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
510.010134 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
510.011643 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.5093ms (max=1000ms) -
510.011643 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
510.025272 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.6295ms (max=1200ms) -
510.025272 Get Diagnostic Response Positive response was received. -
510.025272 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
510.025272 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.23.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
510.025272 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 23 -
510.025272 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.23.5. Wait: None
510.035272 1 Waited for 10.000 ms -
20.23.6. Wait 10ms: None
510.045272 1 Waited for 10.000 ms -
20.24. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 24)
20.24.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
510.045272 Diagnostic request 0x11, 0x01 -
510.046723 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.45058ms (max=1000ms) -
510.046723 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
510.055327 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.60353ms (max=1200ms) -
510.055327 Get Diagnostic Response Positive response was received. -
510.055327 Diagnostic response 0x51, 0x01 -
510.055327 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.24.2. (In for loop)Wait for the diagnostics to start: None
512.455327 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.24.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
512.455327 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
512.456919 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.592ms (max=1000ms) -
512.456919 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
512.470480 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.5615ms (max=1200ms) -
512.470480 Get Diagnostic Response Positive response was received. -
512.470480 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
512.470480 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.24.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
512.470480 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 24 -
512.470480 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.24.5. Wait: None
512.480480 1 Waited for 10.000 ms -
20.24.6. Wait 10ms: None
512.490480 1 Waited for 10.000 ms -
20.25. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 25)
20.25.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
512.490480 Diagnostic request 0x11, 0x01 -
512.492029 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.54858ms (max=1000ms) -
512.492029 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
512.500534 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.50558ms (max=1200ms) -
512.500534 Get Diagnostic Response Positive response was received. -
512.500534 Diagnostic response 0x51, 0x01 -
512.500534 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.25.2. (In for loop)Wait for the diagnostics to start: None
514.900534 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.25.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
514.900534 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
514.902009 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.47466ms (max=1000ms) -
514.902009 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
514.915692 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.6835ms (max=1200ms) -
514.915692 Get Diagnostic Response Positive response was received. -
514.915692 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
514.915692 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.25.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
514.915692 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 25 -
514.915692 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.25.5. Wait: None
514.925692 1 Waited for 10.000 ms -
20.25.6. Wait 10ms: None
514.935692 1 Waited for 10.000 ms -
20.26. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 26)
20.26.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
514.935692 Diagnostic request 0x11, 0x01 -
514.937035 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.34256ms (max=1000ms) -
514.937035 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
514.945746 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.71156ms (max=1200ms) -
514.945746 Get Diagnostic Response Positive response was received. -
514.945746 Diagnostic response 0x51, 0x01 -
514.945746 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.26.2. (In for loop)Wait for the diagnostics to start: None
517.345746 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.26.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
517.345746 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
517.347233 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.48626ms (max=1000ms) -
517.347233 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
517.361014 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.7815ms (max=1200ms) -
517.361014 Get Diagnostic Response Positive response was received. -
517.361014 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
517.361014 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.26.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
517.361014 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 26 -
517.361014 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.26.5. Wait: None
517.371014 1 Waited for 10.000 ms -
20.26.6. Wait 10ms: None
517.381014 1 Waited for 10.000 ms -
20.27. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 27)
20.27.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
517.381014 Diagnostic request 0x11, 0x01 -
517.382355 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.34058ms (max=1000ms) -
517.382355 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
517.391068 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.71355ms (max=1200ms) -
517.391068 Get Diagnostic Response Positive response was received. -
517.391068 Diagnostic response 0x51, 0x01 -
517.391068 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.27.2. (In for loop)Wait for the diagnostics to start: None
519.791068 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.27.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
519.791068 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
519.792528 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.45939ms (max=1000ms) -
519.792528 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
519.806278 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.7499ms (max=1200ms) -
519.806278 Get Diagnostic Response Positive response was received. -
519.806278 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
519.806278 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.27.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
519.806278 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 27 -
519.806278 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.27.5. Wait: None
519.816278 1 Waited for 10.000 ms -
20.27.6. Wait 10ms: None
519.826278 1 Waited for 10.000 ms -
20.28. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 28)
20.28.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
519.826278 Diagnostic request 0x11, 0x01 -
519.827642 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.36455ms (max=1000ms) -
519.827642 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
519.836270 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.62759ms (max=1200ms) -
519.836270 Get Diagnostic Response Positive response was received. -
519.836270 Diagnostic response 0x51, 0x01 -
519.836270 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.28.2. (In for loop)Wait for the diagnostics to start: None
522.236270 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.28.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
522.236270 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
522.237809 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.53944ms (max=1000ms) -
522.237809 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
522.251461 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.6515ms (max=1200ms) -
522.251461 Get Diagnostic Response Positive response was received. -
522.251461 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
522.251461 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.28.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
522.251461 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 28 -
522.251461 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.28.5. Wait: None
522.261461 1 Waited for 10.000 ms -
20.28.6. Wait 10ms: None
522.271461 1 Waited for 10.000 ms -
20.29. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 29)
20.29.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
522.271461 Diagnostic request 0x11, 0x01 -
522.272901 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.44056ms (max=1000ms) -
522.272901 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
522.281518 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.61705ms (max=1200ms) -
522.281518 Get Diagnostic Response Positive response was received. -
522.281518 Diagnostic response 0x51, 0x01 -
522.281518 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.29.2. (In for loop)Wait for the diagnostics to start: None
524.681518 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.29.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
524.681518 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
524.682972 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.45397ms (max=1000ms) -
524.682972 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
524.696760 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.7875ms (max=1200ms) -
524.696760 Get Diagnostic Response Positive response was received. -
524.696760 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
524.696760 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.29.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
524.696760 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 29 -
524.696760 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.29.5. Wait: None
524.706760 1 Waited for 10.000 ms -
20.29.6. Wait 10ms: None
524.716760 1 Waited for 10.000 ms -
20.30. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 30)
20.30.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
524.716760 Diagnostic request 0x11, 0x01 -
524.718084 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.32458ms (max=1000ms) -
524.718084 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
524.726813 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.72856ms (max=1200ms) -
524.726813 Get Diagnostic Response Positive response was received. -
524.726813 Diagnostic response 0x51, 0x01 -
524.726813 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.30.2. (In for loop)Wait for the diagnostics to start: None
527.126813 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.30.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
527.126813 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
527.128305 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.49219ms (max=1000ms) -
527.128305 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
527.141957 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.6515ms (max=1200ms) -
527.141957 Get Diagnostic Response Positive response was received. -
527.141957 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
527.141957 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.30.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
527.141957 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 30 -
527.141957 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.30.5. Wait: None
527.151957 1 Waited for 10.000 ms -
20.30.6. Wait 10ms: None
527.161957 1 Waited for 10.000 ms -
20.31. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 31)
20.31.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
527.161957 Diagnostic request 0x11, 0x01 -
527.163285 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.32859ms (max=1000ms) -
527.163285 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
527.172012 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.72656ms (max=1200ms) -
527.172012 Get Diagnostic Response Positive response was received. -
527.172012 Diagnostic response 0x51, 0x01 -
527.172012 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.31.2. (In for loop)Wait for the diagnostics to start: None
529.572012 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.31.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
529.572012 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
529.573508 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.49581ms (max=1000ms) -
529.573508 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
529.587141 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.6335ms (max=1200ms) -
529.587141 Get Diagnostic Response Positive response was received. -
529.587141 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
529.587141 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.31.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
529.587141 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 31 -
529.587141 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.31.5. Wait: None
529.597141 1 Waited for 10.000 ms -
20.31.6. Wait 10ms: None
529.607141 1 Waited for 10.000 ms -
20.32. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 32)
20.32.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
529.607141 Diagnostic request 0x11, 0x01 -
529.608460 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.31875ms (max=1000ms) -
529.608460 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
529.617198 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.73853ms (max=1200ms) -
529.617198 Get Diagnostic Response Positive response was received. -
529.617198 Diagnostic response 0x51, 0x01 -
529.617198 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.32.2. (In for loop)Wait for the diagnostics to start: None
532.017198 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.32.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
532.017198 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
532.018588 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.38916ms (max=1000ms) -
532.018588 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
532.032317 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.7295ms (max=1200ms) -
532.032317 Get Diagnostic Response Positive response was received. -
532.032317 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
532.032317 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.32.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
532.032317 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 32 -
532.032317 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.32.5. Wait: None
532.042317 1 Waited for 10.000 ms -
20.32.6. Wait 10ms: None
532.052317 1 Waited for 10.000 ms -
20.33. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 33)
20.33.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
532.052317 Diagnostic request 0x11, 0x01 -
532.053674 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.35655ms (max=1000ms) -
532.053674 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
532.062370 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.69603ms (max=1200ms) -
532.062370 Get Diagnostic Response Positive response was received. -
532.062370 Diagnostic response 0x51, 0x01 -
532.062370 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.33.2. (In for loop)Wait for the diagnostics to start: None
534.462370 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.33.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
534.462370 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
534.463866 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.49686ms (max=1000ms) -
534.463866 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
534.477626 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.7595ms (max=1200ms) -
534.477626 Get Diagnostic Response Positive response was received. -
534.477626 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
534.477626 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.33.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
534.477626 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 33 -
534.477626 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.33.5. Wait: None
534.487626 1 Waited for 10.000 ms -
20.33.6. Wait 10ms: None
534.497626 1 Waited for 10.000 ms -
20.34. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 34)
20.34.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
534.497626 Diagnostic request 0x11, 0x01 -
534.499016 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.39056ms (max=1000ms) -
534.499016 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
534.507680 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.66303ms (max=1200ms) -
534.507680 Get Diagnostic Response Positive response was received. -
534.507680 Diagnostic response 0x51, 0x01 -
534.507680 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.34.2. (In for loop)Wait for the diagnostics to start: None
536.907680 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.34.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
536.907680 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
536.909165 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.48516ms (max=1000ms) -
536.909165 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
536.922894 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.7295ms (max=1200ms) -
536.922894 Get Diagnostic Response Positive response was received. -
536.922894 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
536.922894 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.34.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
536.922894 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 34 -
536.922894 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.34.5. Wait: None
536.932894 1 Waited for 10.000 ms -
20.34.6. Wait 10ms: None
536.942894 1 Waited for 10.000 ms -
20.35. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 35)
20.35.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
536.942894 Diagnostic request 0x11, 0x01 -
536.944331 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.43655ms (max=1000ms) -
536.944331 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
536.952948 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.61753ms (max=1200ms) -
536.952948 Get Diagnostic Response Positive response was received. -
536.952948 Diagnostic response 0x51, 0x01 -
536.952948 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.35.2. (In for loop)Wait for the diagnostics to start: None
539.352948 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.35.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
539.352948 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
539.354423 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.47466ms (max=1000ms) -
539.354423 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
539.368158 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.7355ms (max=1200ms) -
539.368158 Get Diagnostic Response Positive response was received. -
539.368158 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
539.368158 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.35.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
539.368158 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 35 -
539.368158 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.35.5. Wait: None
539.378158 1 Waited for 10.000 ms -
20.35.6. Wait 10ms: None
539.388158 1 Waited for 10.000 ms -
20.36. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 36)
20.36.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
539.388158 Diagnostic request 0x11, 0x01 -
539.389439 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.28061ms (max=1000ms) -
539.389439 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
539.398216 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.77655ms (max=1200ms) -
539.398216 Get Diagnostic Response Positive response was received. -
539.398216 Diagnostic response 0x51, 0x01 -
539.398216 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.36.2. (In for loop)Wait for the diagnostics to start: None
541.798216 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.36.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
541.798216 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
541.799554 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.33806ms (max=1000ms) -
541.799554 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
541.813497 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.9439ms (max=1200ms) -
541.813497 Get Diagnostic Response Positive response was received. -
541.813497 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
541.813497 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.36.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
541.813497 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 36 -
541.813497 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.36.5. Wait: None
541.823497 1 Waited for 10.000 ms -
20.36.6. Wait 10ms: None
541.833497 1 Waited for 10.000 ms -
20.37. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 37)
20.37.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
541.833497 Diagnostic request 0x11, 0x01 -
541.834850 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.35261ms (max=1000ms) -
541.834850 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
541.843553 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.70255ms (max=1200ms) -
541.843553 Get Diagnostic Response Positive response was received. -
541.843553 Diagnostic response 0x51, 0x01 -
541.843553 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.37.2. (In for loop)Wait for the diagnostics to start: None
544.243553 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.37.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
544.243553 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
544.245063 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.50992ms (max=1000ms) -
544.245063 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
544.258712 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.6495ms (max=1200ms) -
544.258712 Get Diagnostic Response Positive response was received. -
544.258712 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
544.258712 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.37.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
544.258712 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 37 -
544.258712 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.37.5. Wait: None
544.268712 1 Waited for 10.000 ms -
20.37.6. Wait 10ms: None
544.278712 1 Waited for 10.000 ms -
20.38. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 38)
20.38.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
544.278712 Diagnostic request 0x11, 0x01 -
544.280057 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.34458ms (max=1000ms) -
544.280057 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
544.288769 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.71203ms (max=1200ms) -
544.288769 Get Diagnostic Response Positive response was received. -
544.288769 Diagnostic response 0x51, 0x01 -
544.288769 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.38.2. (In for loop)Wait for the diagnostics to start: None
546.688769 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.38.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
546.688769 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
546.690353 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.58469ms (max=1000ms) -
546.690353 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
546.703903 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.5495ms (max=1200ms) -
546.703903 Get Diagnostic Response Positive response was received. -
546.703903 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
546.703903 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.38.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
546.703903 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 38 -
546.703903 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.38.5. Wait: None
546.713903 1 Waited for 10.000 ms -
20.38.6. Wait 10ms: None
546.723903 1 Waited for 10.000 ms -
20.39. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 39)
20.39.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
546.723903 Diagnostic request 0x11, 0x01 -
546.725253 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.35058ms (max=1000ms) -
546.725253 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
546.733957 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.70356ms (max=1200ms) -
546.733957 Get Diagnostic Response Positive response was received. -
546.733957 Diagnostic response 0x51, 0x01 -
546.733957 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.39.2. (In for loop)Wait for the diagnostics to start: None
549.133957 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.39.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
549.133957 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
549.135470 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.51322ms (max=1000ms) -
549.135470 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
549.149042 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.5715ms (max=1200ms) -
549.149042 Get Diagnostic Response Positive response was received. -
549.149042 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
549.149042 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.39.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
549.149042 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 39 -
549.149042 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.39.5. Wait: None
549.159042 1 Waited for 10.000 ms -
20.39.6. Wait 10ms: None
549.169042 1 Waited for 10.000 ms -
20.40. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 40)
20.40.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
549.169042 Diagnostic request 0x11, 0x01 -
549.170350 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.30855ms (max=1000ms) -
549.170350 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
549.179094 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.74406ms (max=1200ms) -
549.179094 Get Diagnostic Response Positive response was received. -
549.179094 Diagnostic response 0x51, 0x01 -
549.179094 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.40.2. (In for loop)Wait for the diagnostics to start: None
551.579094 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.40.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
551.579094 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
551.580452 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.35794ms (max=1000ms) -
551.580452 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
551.594220 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.7675ms (max=1200ms) -
551.594220 Get Diagnostic Response Positive response was received. -
551.594220 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
551.594220 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.40.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
551.594220 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 40 -
551.594220 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.40.5. Wait: None
551.604220 1 Waited for 10.000 ms -
20.40.6. Wait 10ms: None
551.614220 1 Waited for 10.000 ms -
20.41. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 41)
20.41.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
551.614220 Diagnostic request 0x11, 0x01 -
551.615544 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.32466ms (max=1000ms) -
551.615544 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
551.624277 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.73303ms (max=1200ms) -
551.624277 Get Diagnostic Response Positive response was received. -
551.624277 Diagnostic response 0x51, 0x01 -
551.624277 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.41.2. (In for loop)Wait for the diagnostics to start: None
554.024277 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.41.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
554.024277 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
554.025959 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.68147ms (max=1000ms) -
554.025959 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
554.039356 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.3975ms (max=1200ms) -
554.039356 Get Diagnostic Response Positive response was received. -
554.039356 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
554.039356 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.41.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
554.039356 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 41 -
554.039356 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.41.5. Wait: None
554.049356 1 Waited for 10.000 ms -
20.41.6. Wait 10ms: None
554.059356 1 Waited for 10.000 ms -
20.42. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 42)
20.42.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
554.059356 Diagnostic request 0x11, 0x01 -
554.060809 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.45256ms (max=1000ms) -
554.060809 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
554.069412 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.60256ms (max=1200ms) -
554.069412 Get Diagnostic Response Positive response was received. -
554.069412 Diagnostic response 0x51, 0x01 -
554.069412 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.42.2. (In for loop)Wait for the diagnostics to start: None
556.469412 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.42.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
556.469412 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
556.471105 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.69342ms (max=1000ms) -
556.471105 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
556.484522 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.4175ms (max=1200ms) -
556.484522 Get Diagnostic Response Positive response was received. -
556.484522 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
556.484522 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.42.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
556.484522 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 42 -
556.484522 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.42.5. Wait: None
556.494522 1 Waited for 10.000 ms -
20.42.6. Wait 10ms: None
556.504522 1 Waited for 10.000 ms -
20.43. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 43)
20.43.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
556.504522 Diagnostic request 0x11, 0x01 -
556.505963 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.44056ms (max=1000ms) -
556.505963 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
556.514575 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.61158ms (max=1200ms) -
556.514575 Get Diagnostic Response Positive response was received. -
556.514575 Diagnostic response 0x51, 0x01 -
556.514575 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.43.2. (In for loop)Wait for the diagnostics to start: None
558.914575 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.43.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
558.914575 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
558.916116 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.54155ms (max=1000ms) -
558.916116 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
558.929728 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.6115ms (max=1200ms) -
558.929728 Get Diagnostic Response Positive response was received. -
558.929728 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
558.929728 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.43.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
558.929728 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 43 -
558.929728 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.43.5. Wait: None
558.939728 1 Waited for 10.000 ms -
20.43.6. Wait 10ms: None
558.949728 1 Waited for 10.000 ms -
20.44. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 44)
20.44.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
558.949728 Diagnostic request 0x11, 0x01 -
558.951110 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.38258ms (max=1000ms) -
558.951110 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
558.959778 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.66755ms (max=1200ms) -
558.959778 Get Diagnostic Response Positive response was received. -
558.959778 Diagnostic response 0x51, 0x01 -
558.959778 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.44.2. (In for loop)Wait for the diagnostics to start: None
561.359778 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.44.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
561.359778 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
561.361285 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.50755ms (max=1000ms) -
561.361285 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
561.374877 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.5915ms (max=1200ms) -
561.374877 Get Diagnostic Response Positive response was received. -
561.374877 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
561.374877 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.44.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
561.374877 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 44 -
561.374877 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.44.5. Wait: None
561.384877 1 Waited for 10.000 ms -
20.44.6. Wait 10ms: None
561.394877 1 Waited for 10.000 ms -
20.45. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 45)
20.45.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
561.394877 Diagnostic request 0x11, 0x01 -
561.396253 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.37659ms (max=1000ms) -
561.396253 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
561.404994 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.74058ms (max=1200ms) -
561.404994 Get Diagnostic Response Positive response was received. -
561.404994 Diagnostic response 0x51, 0x01 -
561.404994 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.45.2. (In for loop)Wait for the diagnostics to start: None
563.804994 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.45.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
563.804994 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
563.806439 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.4448ms (max=1000ms) -
563.806439 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
563.820066 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.6275ms (max=1200ms) -
563.820066 Get Diagnostic Response Positive response was received. -
563.820066 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
563.820066 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.45.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
563.820066 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 45 -
563.820066 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.45.5. Wait: None
563.830066 1 Waited for 10.000 ms -
20.45.6. Wait 10ms: None
563.840066 1 Waited for 10.000 ms -
20.46. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 46)
20.46.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
563.840066 Diagnostic request 0x11, 0x01 -
563.841501 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.43459ms (max=1000ms) -
563.841501 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
563.850117 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.61606ms (max=1200ms) -
563.850117 Get Diagnostic Response Positive response was received. -
563.850117 Diagnostic response 0x51, 0x01 -
563.850117 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.46.2. (In for loop)Wait for the diagnostics to start: None
566.250117 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.46.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
566.250117 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
566.251601 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.48422ms (max=1000ms) -
566.251601 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
566.265213 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.6115ms (max=1200ms) -
566.265213 Get Diagnostic Response Positive response was received. -
566.265213 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
566.265213 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.46.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
566.265213 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 46 -
566.265213 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.46.5. Wait: None
566.275213 1 Waited for 10.000 ms -
20.46.6. Wait 10ms: None
566.285213 1 Waited for 10.000 ms -
20.47. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 47)
20.47.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
566.285213 Diagnostic request 0x11, 0x01 -
566.286477 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.26458ms (max=1000ms) -
566.286477 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
566.295263 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.78555ms (max=1200ms) -
566.295263 Get Diagnostic Response Positive response was received. -
566.295263 Diagnostic response 0x51, 0x01 -
566.295263 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.47.2. (In for loop)Wait for the diagnostics to start: None
568.695263 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.47.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
568.695263 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
568.696884 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.62158ms (max=1000ms) -
568.696884 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
568.710456 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.5715ms (max=1200ms) -
568.710456 Get Diagnostic Response Positive response was received. -
568.710456 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
568.710456 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.47.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
568.710456 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 47 -
568.710456 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.47.5. Wait: None
568.720456 1 Waited for 10.000 ms -
20.47.6. Wait 10ms: None
568.730456 1 Waited for 10.000 ms -
20.48. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 48)
20.48.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
568.730456 Diagnostic request 0x11, 0x01 -
568.731874 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.41855ms (max=1000ms) -
568.731874 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
568.740512 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.63756ms (max=1200ms) -
568.740512 Get Diagnostic Response Positive response was received. -
568.740512 Diagnostic response 0x51, 0x01 -
568.740512 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.48.2. (In for loop)Wait for the diagnostics to start: None
571.140512 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.48.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
571.140512 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
571.142079 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.56748ms (max=1000ms) -
571.142079 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
571.155727 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.6475ms (max=1200ms) -
571.155727 Get Diagnostic Response Positive response was received. -
571.155727 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
571.155727 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.48.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
571.155727 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 48 -
571.155727 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.48.5. Wait: None
571.165727 1 Waited for 10.000 ms -
20.48.6. Wait 10ms: None
571.175727 1 Waited for 10.000 ms -
20.49. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 49)
20.49.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
571.175727 Diagnostic request 0x11, 0x01 -
571.177106 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.37856ms (max=1000ms) -
571.177106 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
571.185780 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.67403ms (max=1200ms) -
571.185780 Get Diagnostic Response Positive response was received. -
571.185780 Diagnostic response 0x51, 0x01 -
571.185780 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.49.2. (In for loop)Wait for the diagnostics to start: None
573.585780 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.49.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
573.585780 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
573.587288 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.5082ms (max=1000ms) -
573.587288 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
573.600969 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.6815ms (max=1200ms) -
573.600969 Get Diagnostic Response Positive response was received. -
573.600969 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
573.600969 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.49.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
573.600969 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 49 -
573.600969 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.49.5. Wait: None
573.610969 1 Waited for 10.000 ms -
20.49.6. Wait 10ms: None
573.620969 1 Waited for 10.000 ms -
20.50. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 50)
20.50.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
573.620969 Diagnostic request 0x11, 0x01 -
573.622318 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.34858ms (max=1000ms) -
573.622318 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
573.631022 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.70453ms (max=1200ms) -
573.631022 Get Diagnostic Response Positive response was received. -
573.631022 Diagnostic response 0x51, 0x01 -
573.631022 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.50.2. (In for loop)Wait for the diagnostics to start: None
576.031022 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.50.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
576.031022 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
576.032509 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.48614ms (max=1000ms) -
576.032509 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
576.046190 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.6815ms (max=1200ms) -
576.046190 Get Diagnostic Response Positive response was received. -
576.046190 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
576.046190 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.50.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
576.046190 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 50 -
576.046190 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.50.5. Wait: None
576.056190 1 Waited for 10.000 ms -
20.50.6. Wait 10ms: None
576.066190 1 Waited for 10.000 ms -
20.51. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 51)
20.51.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
576.066190 Diagnostic request 0x11, 0x01 -
576.067405 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.21456ms (max=1000ms) -
576.067405 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
576.076244 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.83953ms (max=1200ms) -
576.076244 Get Diagnostic Response Positive response was received. -
576.076244 Diagnostic response 0x51, 0x01 -
576.076244 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.51.2. (In for loop)Wait for the diagnostics to start: None
578.476244 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.51.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
578.476244 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
578.477792 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.54748ms (max=1000ms) -
578.477792 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
578.491391 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.5995ms (max=1200ms) -
578.491391 Get Diagnostic Response Positive response was received. -
578.491391 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
578.491391 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.51.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
578.491391 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 51 -
578.491391 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.51.5. Wait: None
578.501391 1 Waited for 10.000 ms -
20.51.6. Wait 10ms: None
578.511391 1 Waited for 10.000 ms -
20.52. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 52)
20.52.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
578.511391 Diagnostic request 0x11, 0x01 -
578.512790 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.39855ms (max=1000ms) -
578.512790 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
578.521443 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.65353ms (max=1200ms) -
578.521443 Get Diagnostic Response Positive response was received. -
578.521443 Diagnostic response 0x51, 0x01 -
578.521443 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.52.2. (In for loop)Wait for the diagnostics to start: None
580.921443 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.52.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
580.921443 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
580.923017 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.57419ms (max=1000ms) -
580.923017 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
580.936473 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.4555ms (max=1200ms) -
580.936473 Get Diagnostic Response Positive response was received. -
580.936473 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
580.936473 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.52.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
580.936473 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 52 -
580.936473 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.52.5. Wait: None
580.946473 1 Waited for 10.000 ms -
20.52.6. Wait 10ms: None
580.956473 1 Waited for 10.000 ms -
20.53. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 53)
20.53.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
580.956473 Diagnostic request 0x11, 0x01 -
580.957813 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.34055ms (max=1000ms) -
580.957813 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
580.966525 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.71153ms (max=1200ms) -
580.966525 Get Diagnostic Response Positive response was received. -
580.966525 Diagnostic response 0x51, 0x01 -
580.966525 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.53.2. (In for loop)Wait for the diagnostics to start: None
583.366525 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.53.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
583.366525 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
583.368019 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.49441ms (max=1000ms) -
583.368019 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
583.381689 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.6695ms (max=1200ms) -
583.381689 Get Diagnostic Response Positive response was received. -
583.381689 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
583.381689 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.53.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
583.381689 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 53 -
583.381689 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.53.5. Wait: None
583.391689 1 Waited for 10.000 ms -
20.53.6. Wait 10ms: None
583.401689 1 Waited for 10.000 ms -
20.54. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 54)
20.54.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
583.401689 Diagnostic request 0x11, 0x01 -
583.403070 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.38095ms (max=1000ms) -
583.403070 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
583.411740 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.67058ms (max=1200ms) -
583.411740 Get Diagnostic Response Positive response was received. -
583.411740 Diagnostic response 0x51, 0x01 -
583.411740 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.54.2. (In for loop)Wait for the diagnostics to start: None
585.811740 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.54.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
585.811740 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
585.813371 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.63106ms (max=1000ms) -
585.813371 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
585.826913 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.5415ms (max=1200ms) -
585.826913 Get Diagnostic Response Positive response was received. -
585.826913 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
585.826913 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.54.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
585.826913 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 54 -
585.826913 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.54.5. Wait: None
585.836913 1 Waited for 10.000 ms -
20.54.6. Wait 10ms: None
585.846913 1 Waited for 10.000 ms -
20.55. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 55)
20.55.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
585.846913 Diagnostic request 0x11, 0x01 -
585.848181 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.26858ms (max=1000ms) -
585.848181 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
585.856965 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.78355ms (max=1200ms) -
585.856965 Get Diagnostic Response Positive response was received. -
585.856965 Diagnostic response 0x51, 0x01 -
585.856965 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.55.2. (In for loop)Wait for the diagnostics to start: None
588.256965 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.55.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
588.256965 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
588.258377 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.41205ms (max=1000ms) -
588.258377 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
588.272141 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.7635ms (max=1200ms) -
588.272141 Get Diagnostic Response Positive response was received. -
588.272141 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
588.272141 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.55.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
588.272141 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 55 -
588.272141 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.55.5. Wait: None
588.282141 1 Waited for 10.000 ms -
20.55.6. Wait 10ms: None
588.292141 1 Waited for 10.000 ms -
20.56. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 56)
20.56.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
588.292141 Diagnostic request 0x11, 0x01 -
588.293415 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.27459ms (max=1000ms) -
588.293415 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
588.302199 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.78355ms (max=1200ms) -
588.302199 Get Diagnostic Response Positive response was received. -
588.302199 Diagnostic response 0x51, 0x01 -
588.302199 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.56.2. (In for loop)Wait for the diagnostics to start: None
590.702199 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.56.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
590.702199 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
590.703582 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.38361ms (max=1000ms) -
590.703582 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
590.717338 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.7555ms (max=1200ms) -
590.717338 Get Diagnostic Response Positive response was received. -
590.717338 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
590.717338 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.56.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
590.717338 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 56 -
590.717338 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.56.5. Wait: None
590.727338 1 Waited for 10.000 ms -
20.56.6. Wait 10ms: None
590.737338 1 Waited for 10.000 ms -
20.57. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 57)
20.57.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
590.737338 Diagnostic request 0x11, 0x01 -
590.738742 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.40458ms (max=1000ms) -
590.738742 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
590.747390 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.64756ms (max=1200ms) -
590.747390 Get Diagnostic Response Positive response was received. -
590.747390 Diagnostic response 0x51, 0x01 -
590.747390 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.57.2. (In for loop)Wait for the diagnostics to start: None
593.147390 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.57.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
593.147390 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
593.148888 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.49831ms (max=1000ms) -
593.148888 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
593.162660 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.7715ms (max=1200ms) -
593.162660 Get Diagnostic Response Positive response was received. -
593.162660 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
593.162660 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.57.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
593.162660 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 57 -
593.162660 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.57.5. Wait: None
593.172660 1 Waited for 10.000 ms -
20.57.6. Wait 10ms: None
593.182660 1 Waited for 10.000 ms -
20.58. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 58)
20.58.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
593.182660 Diagnostic request 0x11, 0x01 -
593.184112 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.45258ms (max=1000ms) -
593.184112 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
593.192713 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.60053ms (max=1200ms) -
593.192713 Get Diagnostic Response Positive response was received. -
593.192713 Diagnostic response 0x51, 0x01 -
593.192713 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.58.2. (In for loop)Wait for the diagnostics to start: None
595.592713 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.58.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
595.592713 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
595.594209 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.49639ms (max=1000ms) -
595.594209 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
595.607871 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.662ms (max=1200ms) -
595.607871 Get Diagnostic Response Positive response was received. -
595.607871 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
595.607871 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.58.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
595.607871 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 58 -
595.607871 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.58.5. Wait: None
595.617871 1 Waited for 10.000 ms -
20.58.6. Wait 10ms: None
595.627871 1 Waited for 10.000 ms -
20.59. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 59)
20.59.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
595.627871 Diagnostic request 0x11, 0x01 -
595.629154 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.28258ms (max=1000ms) -
595.629154 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
595.637928 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.77406ms (max=1200ms) -
595.637928 Get Diagnostic Response Positive response was received. -
595.637928 Diagnostic response 0x51, 0x01 -
595.637928 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.59.2. (In for loop)Wait for the diagnostics to start: None
598.037928 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.59.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
598.037928 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
598.039398 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.47023ms (max=1000ms) -
598.039398 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
598.053015 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.6175ms (max=1200ms) -
598.053015 Get Diagnostic Response Positive response was received. -
598.053015 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
598.053015 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.59.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
598.053015 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 59 -
598.053015 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.59.5. Wait: None
598.063015 1 Waited for 10.000 ms -
20.59.6. Wait 10ms: None
598.073015 1 Waited for 10.000 ms -
20.60. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 60)
20.60.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
598.073015 Diagnostic request 0x11, 0x01 -
598.074370 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.35455ms (max=1000ms) -
598.074370 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
598.083071 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.70106ms (max=1200ms) -
598.083071 Get Diagnostic Response Positive response was received. -
598.083071 Diagnostic response 0x51, 0x01 -
598.083071 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.60.2. (In for loop)Wait for the diagnostics to start: None
600.483071 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.60.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
600.483071 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
600.484612 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.54137ms (max=1000ms) -
600.484612 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
600.498258 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.6455ms (max=1200ms) -
600.498258 Get Diagnostic Response Positive response was received. -
600.498258 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
600.498258 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.60.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
600.498258 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 60 -
600.498258 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.60.5. Wait: None
600.508258 1 Waited for 10.000 ms -
20.60.6. Wait 10ms: None
600.518258 1 Waited for 10.000 ms -
20.61. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 61)
20.61.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
600.518258 Diagnostic request 0x11, 0x01 -
600.519660 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.40258ms (max=1000ms) -
600.519660 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
600.528311 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.65003ms (max=1200ms) -
600.528311 Get Diagnostic Response Positive response was received. -
600.528311 Diagnostic response 0x51, 0x01 -
600.528311 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.61.2. (In for loop)Wait for the diagnostics to start: None
602.928311 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.61.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
602.928311 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
602.929814 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.50308ms (max=1000ms) -
602.929814 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
602.943421 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.6075ms (max=1200ms) -
602.943421 Get Diagnostic Response Positive response was received. -
602.943421 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
602.943421 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.61.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
602.943421 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 61 -
602.943421 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.61.5. Wait: None
602.953421 1 Waited for 10.000 ms -
20.61.6. Wait 10ms: None
602.963421 1 Waited for 10.000 ms -
20.62. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 62)
20.62.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
602.963421 Diagnostic request 0x11, 0x01 -
602.964864 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.44258ms (max=1000ms) -
602.964864 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
602.973472 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.60853ms (max=1200ms) -
602.973472 Get Diagnostic Response Positive response was received. -
602.973472 Diagnostic response 0x51, 0x01 -
602.973472 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.62.2. (In for loop)Wait for the diagnostics to start: None
605.373472 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.62.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
605.373472 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
605.374877 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.40508ms (max=1000ms) -
605.374877 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
605.388677 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.7995ms (max=1200ms) -
605.388677 Get Diagnostic Response Positive response was received. -
605.388677 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
605.388677 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.62.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
605.388677 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 62 -
605.388677 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.62.5. Wait: None
605.398677 1 Waited for 10.000 ms -
20.62.6. Wait 10ms: None
605.408677 1 Waited for 10.000 ms -
20.63. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 63)
20.63.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
605.408677 Diagnostic request 0x11, 0x01 -
605.409961 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.2847ms (max=1000ms) -
605.409961 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
605.418728 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.76653ms (max=1200ms) -
605.418728 Get Diagnostic Response Positive response was received. -
605.418728 Diagnostic response 0x51, 0x01 -
605.418728 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.63.2. (In for loop)Wait for the diagnostics to start: None
607.818728 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.63.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
607.818728 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
607.820167 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.43909ms (max=1000ms) -
607.820167 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
607.833907 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.7395ms (max=1200ms) -
607.833907 Get Diagnostic Response Positive response was received. -
607.833907 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
607.833907 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.63.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
607.833907 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 63 -
607.833907 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.63.5. Wait: None
607.843907 1 Waited for 10.000 ms -
20.63.6. Wait 10ms: None
607.853907 1 Waited for 10.000 ms -
20.64. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 64)
20.64.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
607.853907 Diagnostic request 0x11, 0x01 -
607.855273 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.36659ms (max=1000ms) -
607.855273 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
607.863961 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.68803ms (max=1200ms) -
607.863961 Get Diagnostic Response Positive response was received. -
607.863961 Diagnostic response 0x51, 0x01 -
607.863961 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.64.2. (In for loop)Wait for the diagnostics to start: None
610.263961 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.64.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
610.263961 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
610.265425 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.46362ms (max=1000ms) -
610.265425 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
610.279148 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.7235ms (max=1200ms) -
610.279148 Get Diagnostic Response Positive response was received. -
610.279148 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
610.279148 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.64.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
610.279148 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 64 -
610.279148 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.64.5. Wait: None
610.289148 1 Waited for 10.000 ms -
20.64.6. Wait 10ms: None
610.299148 1 Waited for 10.000 ms -
20.65. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 65)
20.65.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
610.299148 Diagnostic request 0x11, 0x01 -
610.300389 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.24056ms (max=1000ms) -
610.300389 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
610.309202 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.81353ms (max=1200ms) -
610.309202 Get Diagnostic Response Positive response was received. -
610.309202 Diagnostic response 0x51, 0x01 -
610.309202 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.65.2. (In for loop)Wait for the diagnostics to start: None
612.709202 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.65.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
612.709202 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
612.710562 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.35933ms (max=1000ms) -
612.710562 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
612.724397 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.8355ms (max=1200ms) -
612.724397 Get Diagnostic Response Positive response was received. -
612.724397 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
612.724397 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.65.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
612.724397 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 65 -
612.724397 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.65.5. Wait: None
612.734397 1 Waited for 10.000 ms -
20.65.6. Wait 10ms: None
612.744397 1 Waited for 10.000 ms -
20.66. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 66)
20.66.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
612.744397 Diagnostic request 0x11, 0x01 -
612.745846 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.44858ms (max=1000ms) -
612.745846 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
612.754449 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.60356ms (max=1200ms) -
612.754449 Get Diagnostic Response Positive response was received. -
612.754449 Diagnostic response 0x51, 0x01 -
612.754449 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.66.2. (In for loop)Wait for the diagnostics to start: None
615.154449 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.66.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
615.154449 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
615.156013 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.56349ms (max=1000ms) -
615.156013 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
615.169652 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.6395ms (max=1200ms) -
615.169652 Get Diagnostic Response Positive response was received. -
615.169652 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
615.169652 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.66.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
615.169652 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 66 -
615.169652 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.66.5. Wait: None
615.179652 1 Waited for 10.000 ms -
20.66.6. Wait 10ms: None
615.189652 1 Waited for 10.000 ms -
20.67. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 67)
20.67.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
615.189652 Diagnostic request 0x11, 0x01 -
615.191121 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.46858ms (max=1000ms) -
615.191121 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
615.199707 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.58653ms (max=1200ms) -
615.199707 Get Diagnostic Response Positive response was received. -
615.199707 Diagnostic response 0x51, 0x01 -
615.199707 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.67.2. (In for loop)Wait for the diagnostics to start: None
617.599707 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.67.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
617.599707 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
617.601483 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.77588ms (max=1000ms) -
617.601483 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
617.614881 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.3975ms (max=1200ms) -
617.614881 Get Diagnostic Response Positive response was received. -
617.614881 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
617.614881 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.67.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
617.614881 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 67 -
617.614881 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.67.5. Wait: None
617.624881 1 Waited for 10.000 ms -
20.67.6. Wait 10ms: None
617.634881 1 Waited for 10.000 ms -
20.68. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 68)
20.68.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
617.634881 Diagnostic request 0x11, 0x01 -
617.636227 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.34655ms (max=1000ms) -
617.636227 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
617.644932 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.70455ms (max=1200ms) -
617.644932 Get Diagnostic Response Positive response was received. -
617.644932 Diagnostic response 0x51, 0x01 -
617.644932 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.68.2. (In for loop)Wait for the diagnostics to start: None
620.044932 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.68.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
620.044932 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
620.046389 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.45733ms (max=1000ms) -
620.046389 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
620.060063 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.6735ms (max=1200ms) -
620.060063 Get Diagnostic Response Positive response was received. -
620.060063 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
620.060063 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.68.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
620.060063 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 68 -
620.060063 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.68.5. Wait: None
620.070063 1 Waited for 10.000 ms -
20.68.6. Wait 10ms: None
620.080063 1 Waited for 10.000 ms -
20.69. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 69)
20.69.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
620.080063 Diagnostic request 0x11, 0x01 -
620.081493 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.43053ms (max=1000ms) -
620.081493 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
620.090117 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.62353ms (max=1200ms) -
620.090117 Get Diagnostic Response Positive response was received. -
620.090117 Diagnostic response 0x51, 0x01 -
620.090117 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.69.2. (In for loop)Wait for the diagnostics to start: None
622.490117 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.69.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
622.490117 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
622.491638 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.52086ms (max=1000ms) -
622.491638 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
622.505323 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.6855ms (max=1200ms) -
622.505323 Get Diagnostic Response Positive response was received. -
622.505323 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
622.505323 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.69.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
622.505323 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 69 -
622.505323 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.69.5. Wait: None
622.515323 1 Waited for 10.000 ms -
20.69.6. Wait 10ms: None
622.525323 1 Waited for 10.000 ms -
20.70. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 70)
20.70.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
622.525323 Diagnostic request 0x11, 0x01 -
622.526842 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.51856ms (max=1000ms) -
622.526842 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
622.535378 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.53659ms (max=1200ms) -
622.535378 Get Diagnostic Response Positive response was received. -
622.535378 Diagnostic response 0x51, 0x01 -
622.535378 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.70.2. (In for loop)Wait for the diagnostics to start: None
624.935378 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.70.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
624.935378 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
624.937026 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.64783ms (max=1000ms) -
624.937026 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
624.950510 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.4835ms (max=1200ms) -
624.950510 Get Diagnostic Response Positive response was received. -
624.950510 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
624.950510 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.70.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
624.950510 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 70 -
624.950510 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.70.5. Wait: None
624.960510 1 Waited for 10.000 ms -
20.70.6. Wait 10ms: None
624.970510 1 Waited for 10.000 ms -
20.71. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 71)
20.71.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
624.970510 Diagnostic request 0x11, 0x01 -
624.971938 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.42855ms (max=1000ms) -
624.971938 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
624.980565 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.62706ms (max=1200ms) -
624.980565 Get Diagnostic Response Positive response was received. -
624.980565 Diagnostic response 0x51, 0x01 -
624.980565 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.71.2. (In for loop)Wait for the diagnostics to start: None
627.380565 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.71.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
627.380565 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
627.382073 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.50772ms (max=1000ms) -
627.382073 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
627.395738 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.6655ms (max=1200ms) -
627.395738 Get Diagnostic Response Positive response was received. -
627.395738 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
627.395738 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.71.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
627.395738 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 71 -
627.395738 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.71.5. Wait: None
627.405738 1 Waited for 10.000 ms -
20.71.6. Wait 10ms: None
627.415738 1 Waited for 10.000 ms -
20.72. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 72)
20.72.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
627.415738 Diagnostic request 0x11, 0x01 -
627.417117 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.37864ms (max=1000ms) -
627.417117 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
627.425793 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.67556ms (max=1200ms) -
627.425793 Get Diagnostic Response Positive response was received. -
627.425793 Diagnostic response 0x51, 0x01 -
627.425793 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.72.2. (In for loop)Wait for the diagnostics to start: None
629.825793 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.72.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
629.825793 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
629.827168 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.37516ms (max=1000ms) -
629.827168 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
629.840875 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.7075ms (max=1200ms) -
629.840875 Get Diagnostic Response Positive response was received. -
629.840875 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
629.840875 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.72.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
629.840875 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 72 -
629.840875 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.72.5. Wait: None
629.850875 1 Waited for 10.000 ms -
20.72.6. Wait 10ms: None
629.860875 1 Waited for 10.000 ms -
20.73. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 73)
20.73.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
629.860875 Diagnostic request 0x11, 0x01 -
629.862300 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.42458ms (max=1000ms) -
629.862300 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
629.870927 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.62753ms (max=1200ms) -
629.870927 Get Diagnostic Response Positive response was received. -
629.870927 Diagnostic response 0x51, 0x01 -
629.870927 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.73.2. (In for loop)Wait for the diagnostics to start: None
632.270927 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.73.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
632.270927 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
632.272393 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.46592ms (max=1000ms) -
632.272393 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
632.285993 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.5995ms (max=1200ms) -
632.285993 Get Diagnostic Response Positive response was received. -
632.285993 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
632.285993 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.73.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
632.285993 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 73 -
632.285993 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.73.5. Wait: None
632.295993 1 Waited for 10.000 ms -
20.73.6. Wait 10ms: None
632.305993 1 Waited for 10.000 ms -
20.74. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 74)
20.74.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
632.305993 Diagnostic request 0x11, 0x01 -
632.307303 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.31058ms (max=1000ms) -
632.307303 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
632.316044 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.74053ms (max=1200ms) -
632.316044 Get Diagnostic Response Positive response was received. -
632.316044 Diagnostic response 0x51, 0x01 -
632.316044 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.74.2. (In for loop)Wait for the diagnostics to start: None
634.716044 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.74.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
634.716044 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
634.717527 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.4832ms (max=1000ms) -
634.717527 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
634.731101 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.5735ms (max=1200ms) -
634.731101 Get Diagnostic Response Positive response was received. -
634.731101 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
634.731101 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.74.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
634.731101 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 74 -
634.731101 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.74.5. Wait: None
634.741101 1 Waited for 10.000 ms -
20.74.6. Wait 10ms: None
634.751101 1 Waited for 10.000 ms -
20.75. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 75)
20.75.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
634.751101 Diagnostic request 0x11, 0x01 -
634.752389 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.28858ms (max=1000ms) -
634.752389 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
634.761155 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.76555ms (max=1200ms) -
634.761155 Get Diagnostic Response Positive response was received. -
634.761155 Diagnostic response 0x51, 0x01 -
634.761155 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.75.2. (In for loop)Wait for the diagnostics to start: None
637.161155 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.75.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
637.161155 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
637.162606 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.45098ms (max=1000ms) -
637.162606 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
637.176241 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.6355ms (max=1200ms) -
637.176241 Get Diagnostic Response Positive response was received. -
637.176241 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
637.176241 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.75.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
637.176241 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 75 -
637.176241 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.75.5. Wait: None
637.186241 1 Waited for 10.000 ms -
20.75.6. Wait 10ms: None
637.196241 1 Waited for 10.000 ms -
20.76. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 76)
20.76.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
637.196241 Diagnostic request 0x11, 0x01 -
637.197706 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.46459ms (max=1000ms) -
637.197706 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
637.206357 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.65147ms (max=1200ms) -
637.206357 Get Diagnostic Response Positive response was received. -
637.206357 Diagnostic response 0x51, 0x01 -
637.206357 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.76.2. (In for loop)Wait for the diagnostics to start: None
639.606357 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.76.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
639.606357 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
639.607845 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.48764ms (max=1000ms) -
639.607845 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
639.621386 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.5415ms (max=1200ms) -
639.621386 Get Diagnostic Response Positive response was received. -
639.621386 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
639.621386 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.76.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
639.621386 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 76 -
639.621386 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.76.5. Wait: None
639.631386 1 Waited for 10.000 ms -
20.76.6. Wait 10ms: None
639.641386 1 Waited for 10.000 ms -
20.77. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 77)
20.77.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
639.641386 Diagnostic request 0x11, 0x01 -
639.642741 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.35456ms (max=1000ms) -
639.642741 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
639.651438 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.69752ms (max=1200ms) -
639.651438 Get Diagnostic Response Positive response was received. -
639.651438 Diagnostic response 0x51, 0x01 -
639.651438 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.77.2. (In for loop)Wait for the diagnostics to start: None
642.051438 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.77.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
642.051438 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
642.053012 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.57325ms (max=1000ms) -
642.053012 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
642.066567 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.5555ms (max=1200ms) -
642.066567 Get Diagnostic Response Positive response was received. -
642.066567 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
642.066567 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.77.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
642.066567 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 77 -
642.066567 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.77.5. Wait: None
642.076567 1 Waited for 10.000 ms -
20.77.6. Wait 10ms: None
642.086567 1 Waited for 10.000 ms -
20.78. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 78)
20.78.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
642.086567 Diagnostic request 0x11, 0x01 -
642.088014 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.44658ms (max=1000ms) -
642.088014 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
642.096621 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.60758ms (max=1200ms) -
642.096621 Get Diagnostic Response Positive response was received. -
642.096621 Diagnostic response 0x51, 0x01 -
642.096621 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.78.2. (In for loop)Wait for the diagnostics to start: None
644.496621 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.78.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
644.496621 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
644.498117 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.49614ms (max=1000ms) -
644.498117 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
644.511739 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.6215ms (max=1200ms) -
644.511739 Get Diagnostic Response Positive response was received. -
644.511739 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
644.511739 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.78.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
644.511739 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 78 -
644.511739 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.78.5. Wait: None
644.521739 1 Waited for 10.000 ms -
20.78.6. Wait 10ms: None
644.531739 1 Waited for 10.000 ms -
20.79. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 79)
20.79.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
644.531739 Diagnostic request 0x11, 0x01 -
644.533159 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.42055ms (max=1000ms) -
644.533159 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
644.541792 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.63203ms (max=1200ms) -
644.541792 Get Diagnostic Response Positive response was received. -
644.541792 Diagnostic response 0x51, 0x01 -
644.541792 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.79.2. (In for loop)Wait for the diagnostics to start: None
646.941792 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.79.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
646.941792 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
646.943298 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.5065ms (max=1000ms) -
646.943298 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
646.956857 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.5595ms (max=1200ms) -
646.956857 Get Diagnostic Response Positive response was received. -
646.956857 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
646.956857 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.79.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
646.956857 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 79 -
646.956857 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.79.5. Wait: None
646.966857 1 Waited for 10.000 ms -
20.79.6. Wait 10ms: None
646.976857 1 Waited for 10.000 ms -
20.80. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 80)
20.80.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
646.976857 Diagnostic request 0x11, 0x01 -
646.978234 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.37658ms (max=1000ms) -
646.978234 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
646.986909 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.67503ms (max=1200ms) -
646.986909 Get Diagnostic Response Positive response was received. -
646.986909 Diagnostic response 0x51, 0x01 -
646.986909 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.80.2. (In for loop)Wait for the diagnostics to start: None
649.386909 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.80.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
649.386909 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
649.388361 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.45214ms (max=1000ms) -
649.388361 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
649.402073 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.7115ms (max=1200ms) -
649.402073 Get Diagnostic Response Positive response was received. -
649.402073 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
649.402073 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.80.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
649.402073 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 80 -
649.402073 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.80.5. Wait: None
649.412073 1 Waited for 10.000 ms -
20.80.6. Wait 10ms: None
649.422073 1 Waited for 10.000 ms -
20.81. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 81)
20.81.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
649.422073 Diagnostic request 0x11, 0x01 -
649.423383 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.31053ms (max=1000ms) -
649.423383 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
649.432061 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.67753ms (max=1200ms) -
649.432061 Get Diagnostic Response Positive response was received. -
649.432061 Diagnostic response 0x51, 0x01 -
649.432061 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.81.2. (In for loop)Wait for the diagnostics to start: None
651.832061 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.81.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
651.832061 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
651.833517 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.45608ms (max=1000ms) -
651.833517 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
651.847046 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.5295ms (max=1200ms) -
651.847046 Get Diagnostic Response Positive response was received. -
651.847046 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
651.847046 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.81.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
651.847046 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 81 -
651.847046 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.81.5. Wait: None
651.857046 1 Waited for 10.000 ms -
20.81.6. Wait 10ms: None
651.867046 1 Waited for 10.000 ms -
20.82. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 82)
20.82.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
651.867046 Diagnostic request 0x11, 0x01 -
651.868333 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.28658ms (max=1000ms) -
651.868333 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
651.877096 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.76353ms (max=1200ms) -
651.877096 Get Diagnostic Response Positive response was received. -
651.877096 Diagnostic response 0x51, 0x01 -
651.877096 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.82.2. (In for loop)Wait for the diagnostics to start: None
654.277096 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.82.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
654.277096 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
654.278507 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.41088ms (max=1000ms) -
654.278507 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
654.292139 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.6315ms (max=1200ms) -
654.292139 Get Diagnostic Response Positive response was received. -
654.292139 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
654.292139 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.82.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
654.292139 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 82 -
654.292139 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.82.5. Wait: None
654.302139 1 Waited for 10.000 ms -
20.82.6. Wait 10ms: None
654.312139 1 Waited for 10.000 ms -
20.83. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 83)
20.83.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
654.312139 Diagnostic request 0x11, 0x01 -
654.313411 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.27256ms (max=1000ms) -
654.313411 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
654.322195 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.78405ms (max=1200ms) -
654.322195 Get Diagnostic Response Positive response was received. -
654.322195 Diagnostic response 0x51, 0x01 -
654.322195 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.83.2. (In for loop)Wait for the diagnostics to start: None
656.722195 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.83.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
656.722195 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
656.723549 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.35381ms (max=1000ms) -
656.723549 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
656.737271 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.7215ms (max=1200ms) -
656.737271 Get Diagnostic Response Positive response was received. -
656.737271 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
656.737271 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.83.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
656.737271 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 83 -
656.737271 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.83.5. Wait: None
656.747271 1 Waited for 10.000 ms -
20.83.6. Wait 10ms: None
656.757271 1 Waited for 10.000 ms -
20.84. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 84)
20.84.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
656.757271 Diagnostic request 0x11, 0x01 -
656.758625 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.35458ms (max=1000ms) -
656.758625 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
656.767325 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.69953ms (max=1200ms) -
656.767325 Get Diagnostic Response Positive response was received. -
656.767325 Diagnostic response 0x51, 0x01 -
656.767325 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.84.2. (In for loop)Wait for the diagnostics to start: None
659.167325 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.84.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
659.167325 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
659.168799 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.47425ms (max=1000ms) -
659.168799 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
659.182327 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.5275ms (max=1200ms) -
659.182327 Get Diagnostic Response Positive response was received. -
659.182327 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
659.182327 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.84.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
659.182327 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 84 -
659.182327 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.84.5. Wait: None
659.192327 1 Waited for 10.000 ms -
20.84.6. Wait 10ms: None
659.202327 1 Waited for 10.000 ms -
20.85. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 85)
20.85.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
659.202327 Diagnostic request 0x11, 0x01 -
659.203668 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.34095ms (max=1000ms) -
659.203668 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
659.212382 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.71455ms (max=1200ms) -
659.212382 Get Diagnostic Response Positive response was received. -
659.212382 Diagnostic response 0x51, 0x01 -
659.212382 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.85.2. (In for loop)Wait for the diagnostics to start: None
661.612382 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.85.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
661.612382 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
661.614059 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.67681ms (max=1000ms) -
661.614059 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
661.627410 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.3515ms (max=1200ms) -
661.627410 Get Diagnostic Response Positive response was received. -
661.627410 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
661.627410 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.85.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
661.627410 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 85 -
661.627410 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.85.5. Wait: None
661.637410 1 Waited for 10.000 ms -
20.85.6. Wait 10ms: None
661.647410 1 Waited for 10.000 ms -
20.86. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 86)
20.86.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
661.647410 Diagnostic request 0x11, 0x01 -
661.648769 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.35858ms (max=1000ms) -
661.648769 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
661.657464 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.69503ms (max=1200ms) -
661.657464 Get Diagnostic Response Positive response was received. -
661.657464 Diagnostic response 0x51, 0x01 -
661.657464 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.86.2. (In for loop)Wait for the diagnostics to start: None
664.057464 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.86.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
664.057464 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
664.059081 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.61689ms (max=1000ms) -
664.059081 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
664.072578 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.4975ms (max=1200ms) -
664.072578 Get Diagnostic Response Positive response was received. -
664.072578 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
664.072578 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.86.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
664.072578 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 86 -
664.072578 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.86.5. Wait: None
664.082578 1 Waited for 10.000 ms -
20.86.6. Wait 10ms: None
664.092578 1 Waited for 10.000 ms -
20.87. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 87)
20.87.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
664.092578 Diagnostic request 0x11, 0x01 -
664.093899 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.32055ms (max=1000ms) -
664.093899 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
664.102631 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.73253ms (max=1200ms) -
664.102631 Get Diagnostic Response Positive response was received. -
664.102631 Diagnostic response 0x51, 0x01 -
664.102631 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.87.2. (In for loop)Wait for the diagnostics to start: None
666.502631 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.87.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
666.502631 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
666.504184 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.55303ms (max=1000ms) -
666.504184 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
666.517762 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.5775ms (max=1200ms) -
666.517762 Get Diagnostic Response Positive response was received. -
666.517762 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
666.517762 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.87.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
666.517762 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 87 -
666.517762 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.87.5. Wait: None
666.527762 1 Waited for 10.000 ms -
20.87.6. Wait 10ms: None
666.537762 1 Waited for 10.000 ms -
20.88. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 88)
20.88.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
666.537762 Diagnostic request 0x11, 0x01 -
666.539103 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.34058ms (max=1000ms) -
666.539103 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
666.547815 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.71253ms (max=1200ms) -
666.547815 Get Diagnostic Response Positive response was received. -
666.547815 Diagnostic response 0x51, 0x01 -
666.547815 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.88.2. (In for loop)Wait for the diagnostics to start: None
668.947815 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.88.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
668.947815 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
668.949243 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.42806ms (max=1000ms) -
668.949243 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
668.963025 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.7815ms (max=1200ms) -
668.963025 Get Diagnostic Response Positive response was received. -
668.963025 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
668.963025 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.88.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
668.963025 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 88 -
668.963025 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.88.5. Wait: None
668.973025 1 Waited for 10.000 ms -
20.88.6. Wait 10ms: None
668.983025 1 Waited for 10.000 ms -
20.89. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 89)
20.89.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
668.983025 Diagnostic request 0x11, 0x01 -
668.984377 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.35255ms (max=1000ms) -
668.984377 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
668.993077 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.69952ms (max=1200ms) -
668.993077 Get Diagnostic Response Positive response was received. -
668.993077 Diagnostic response 0x51, 0x01 -
668.993077 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.89.2. (In for loop)Wait for the diagnostics to start: None
671.393077 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.89.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
671.393077 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
671.394492 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.41559ms (max=1000ms) -
671.394492 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
671.408218 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.7259ms (max=1200ms) -
671.408218 Get Diagnostic Response Positive response was received. -
671.408218 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
671.408218 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.89.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
671.408218 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 89 -
671.408218 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.89.5. Wait: None
671.418218 1 Waited for 10.000 ms -
20.89.6. Wait 10ms: None
671.428218 1 Waited for 10.000 ms -
20.90. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 90)
20.90.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
671.428218 Diagnostic request 0x11, 0x01 -
671.429429 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.21058ms (max=1000ms) -
671.429429 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
671.438278 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.84956ms (max=1200ms) -
671.438278 Get Diagnostic Response Positive response was received. -
671.438278 Diagnostic response 0x51, 0x01 -
671.438278 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.90.2. (In for loop)Wait for the diagnostics to start: None
673.838278 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.90.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
673.838278 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
673.839810 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.53183ms (max=1000ms) -
673.839810 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
673.853384 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.5735ms (max=1200ms) -
673.853384 Get Diagnostic Response Positive response was received. -
673.853384 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
673.853384 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.90.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
673.853384 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 90 -
673.853384 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.90.5. Wait: None
673.863384 1 Waited for 10.000 ms -
20.90.6. Wait 10ms: None
673.873384 1 Waited for 10.000 ms -
20.91. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 91)
20.91.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
673.873384 Diagnostic request 0x11, 0x01 -
673.874732 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.34856ms (max=1000ms) -
673.874732 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
673.883436 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.70356ms (max=1200ms) -
673.883436 Get Diagnostic Response Positive response was received. -
673.883436 Diagnostic response 0x51, 0x01 -
673.883436 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.91.2. (In for loop)Wait for the diagnostics to start: None
676.283436 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.91.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
676.283436 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
676.284941 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.50473ms (max=1000ms) -
676.284941 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
676.298640 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.6995ms (max=1200ms) -
676.298640 Get Diagnostic Response Positive response was received. -
676.298640 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
676.298640 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.91.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
676.298640 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 91 -
676.298640 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.91.5. Wait: None
676.308640 1 Waited for 10.000 ms -
20.91.6. Wait 10ms: None
676.318640 1 Waited for 10.000 ms -
20.92. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 92)
20.92.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
676.318640 Diagnostic request 0x11, 0x01 -
676.319967 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.32656ms (max=1000ms) -
676.319967 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
676.328690 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.72358ms (max=1200ms) -
676.328690 Get Diagnostic Response Positive response was received. -
676.328690 Diagnostic response 0x51, 0x01 -
676.328690 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.92.2. (In for loop)Wait for the diagnostics to start: None
678.728690 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.92.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
678.728690 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
678.730147 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.45648ms (max=1000ms) -
678.730147 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
678.743934 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.7875ms (max=1200ms) -
678.743934 Get Diagnostic Response Positive response was received. -
678.743934 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
678.743934 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.92.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
678.743934 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 92 -
678.743934 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.92.5. Wait: None
678.753934 1 Waited for 10.000 ms -
20.92.6. Wait 10ms: None
678.763934 1 Waited for 10.000 ms -
20.93. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 93)
20.93.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
678.763934 Diagnostic request 0x11, 0x01 -
678.765213 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.27858ms (max=1000ms) -
678.765213 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
678.773989 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.77603ms (max=1200ms) -
678.773989 Get Diagnostic Response Positive response was received. -
678.773989 Diagnostic response 0x51, 0x01 -
678.773989 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.93.2. (In for loop)Wait for the diagnostics to start: None
681.173989 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.93.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
681.173989 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
681.175505 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.51653ms (max=1000ms) -
681.175505 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
681.189193 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.6875ms (max=1200ms) -
681.189193 Get Diagnostic Response Positive response was received. -
681.189193 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
681.189193 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.93.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
681.189193 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 93 -
681.189193 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.93.5. Wait: None
681.199193 1 Waited for 10.000 ms -
20.93.6. Wait 10ms: None
681.209193 1 Waited for 10.000 ms -
20.94. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 94)
20.94.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
681.209193 Diagnostic request 0x11, 0x01 -
681.210413 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.22073ms (max=1000ms) -
681.210413 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
681.219245 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.83158ms (max=1200ms) -
681.219245 Get Diagnostic Response Positive response was received. -
681.219245 Diagnostic response 0x51, 0x01 -
681.219245 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.94.2. (In for loop)Wait for the diagnostics to start: None
683.619245 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.94.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
683.619245 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
683.620908 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.66272ms (max=1000ms) -
683.620908 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
683.634439 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.5315ms (max=1200ms) -
683.634439 Get Diagnostic Response Positive response was received. -
683.634439 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
683.634439 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.94.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
683.634439 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 94 -
683.634439 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.94.5. Wait: None
683.644439 1 Waited for 10.000 ms -
20.94.6. Wait 10ms: None
683.654439 1 Waited for 10.000 ms -
20.95. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 95)
20.95.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
683.654439 Diagnostic request 0x11, 0x01 -
683.655784 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.34456ms (max=1000ms) -
683.655784 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
683.664492 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.70852ms (max=1200ms) -
683.664492 Get Diagnostic Response Positive response was received. -
683.664492 Diagnostic response 0x51, 0x01 -
683.664492 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.95.2. (In for loop)Wait for the diagnostics to start: None
686.064492 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.95.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
686.064492 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
686.066041 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.54905ms (max=1000ms) -
686.066041 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
686.079661 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.6195ms (max=1200ms) -
686.079661 Get Diagnostic Response Positive response was received. -
686.079661 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
686.079661 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.95.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
686.079661 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 95 -
686.079661 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.95.5. Wait: None
686.089661 1 Waited for 10.000 ms -
20.95.6. Wait 10ms: None
686.099661 1 Waited for 10.000 ms -
20.96. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 96)
20.96.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
686.099661 Diagnostic request 0x11, 0x01 -
686.101103 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.44258ms (max=1000ms) -
686.101103 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
686.109718 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.61453ms (max=1200ms) -
686.109718 Get Diagnostic Response Positive response was received. -
686.109718 Diagnostic response 0x51, 0x01 -
686.109718 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.96.2. (In for loop)Wait for the diagnostics to start: None
688.509718 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.96.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
688.509718 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
688.511315 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.59714ms (max=1000ms) -
688.511315 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
688.524891 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.5755ms (max=1200ms) -
688.524891 Get Diagnostic Response Positive response was received. -
688.524891 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
688.524891 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.96.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
688.524891 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 96 -
688.524891 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.96.5. Wait: None
688.534891 1 Waited for 10.000 ms -
20.96.6. Wait 10ms: None
688.544891 1 Waited for 10.000 ms -
20.97. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 97)
20.97.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
688.544891 Diagnostic request 0x11, 0x01 -
688.546247 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.35658ms (max=1000ms) -
688.546247 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
688.554944 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.69652ms (max=1200ms) -
688.554944 Get Diagnostic Response Positive response was received. -
688.554944 Diagnostic response 0x51, 0x01 -
688.554944 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.97.2. (In for loop)Wait for the diagnostics to start: None
690.954944 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.97.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
690.954944 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
690.956451 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.50684ms (max=1000ms) -
690.956451 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
690.970090 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.6395ms (max=1200ms) -
690.970090 Get Diagnostic Response Positive response was received. -
690.970090 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
690.970090 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.97.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
690.970090 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 97 -
690.970090 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.97.5. Wait: None
690.980090 1 Waited for 10.000 ms -
20.97.6. Wait 10ms: None
690.990090 1 Waited for 10.000 ms -
20.98. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 98)
20.98.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
690.990090 Diagnostic request 0x11, 0x01 -
690.991517 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.42658ms (max=1000ms) -
690.991517 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
691.000143 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.62656ms (max=1200ms) -
691.000143 Get Diagnostic Response Positive response was received. -
691.000143 Diagnostic response 0x51, 0x01 -
691.000143 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.98.2. (In for loop)Wait for the diagnostics to start: None
693.400143 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.98.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
693.400143 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
693.401514 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.37102ms (max=1000ms) -
693.401514 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
693.415242 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.7275ms (max=1200ms) -
693.415242 Get Diagnostic Response Positive response was received. -
693.415242 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
693.415242 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.98.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
693.415242 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 98 -
693.415242 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.98.5. Wait: None
693.425242 1 Waited for 10.000 ms -
20.98.6. Wait 10ms: None
693.435242 1 Waited for 10.000 ms -
20.99. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 99)
20.99.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
693.435242 Diagnostic request 0x11, 0x01 -
693.436790 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.54856ms (max=1000ms) -
693.436790 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
693.445301 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.51053ms (max=1200ms) -
693.445301 Get Diagnostic Response Positive response was received. -
693.445301 Diagnostic response 0x51, 0x01 -
693.445301 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.99.2. (In for loop)Wait for the diagnostics to start: None
695.845301 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.99.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
695.845301 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
695.846818 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.5177ms (max=1000ms) -
695.846818 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
695.860360 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.5415ms (max=1200ms) -
695.860360 Get Diagnostic Response Positive response was received. -
695.860360 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
695.860360 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.99.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
695.860360 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 99 -
695.860360 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.99.5. Wait: None
695.870360 1 Waited for 10.000 ms -
20.99.6. Wait 10ms: None
695.880360 1 Waited for 10.000 ms -
20.100. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 100)
20.100.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
695.880360 Diagnostic request 0x11, 0x01 -
695.881891 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.53059ms (max=1000ms) -
695.881891 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
695.890416 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.52556ms (max=1200ms) -
695.890416 Get Diagnostic Response Positive response was received. -
695.890416 Diagnostic response 0x51, 0x01 -
695.890416 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.100.2. (In for loop)Wait for the diagnostics to start: None
698.290416 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.100.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
698.290416 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
698.292045 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.62875ms (max=1000ms) -
698.292045 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
698.305554 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.5095ms (max=1200ms) -
698.305554 Get Diagnostic Response Positive response was received. -
698.305554 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
698.305554 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.100.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
698.305554 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 100 -
698.305554 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.100.5. Wait: None
698.315554 1 Waited for 10.000 ms -
20.100.6. Wait 10ms: None
698.325554 1 Waited for 10.000 ms -
20.101. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 101)
20.101.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
698.325554 Diagnostic request 0x11, 0x01 -
698.326859 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.30458ms (max=1000ms) -
698.326859 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
698.335615 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.75603ms (max=1200ms) -
698.335615 Get Diagnostic Response Positive response was received. -
698.335615 Diagnostic response 0x51, 0x01 -
698.335615 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.101.2. (In for loop)Wait for the diagnostics to start: None
700.735615 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.101.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
700.735615 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
700.737108 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.49291ms (max=1000ms) -
700.737108 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
700.750727 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.6195ms (max=1200ms) -
700.750727 Get Diagnostic Response Positive response was received. -
700.750727 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
700.750727 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.101.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
700.750727 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 101 -
700.750727 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.101.5. Wait: None
700.760727 1 Waited for 10.000 ms -
20.101.6. Wait 10ms: None
700.770727 1 Waited for 10.000 ms -
20.102. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 102)
20.102.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
700.770727 Diagnostic request 0x11, 0x01 -
700.772066 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.33858ms (max=1000ms) -
700.772066 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
700.780779 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.71355ms (max=1200ms) -
700.780779 Get Diagnostic Response Positive response was received. -
700.780779 Diagnostic response 0x51, 0x01 -
700.780779 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.102.2. (In for loop)Wait for the diagnostics to start: None
703.180779 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.102.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
703.180779 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
703.182280 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.50059ms (max=1000ms) -
703.182280 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
703.195982 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.7015ms (max=1200ms) -
703.195982 Get Diagnostic Response Positive response was received. -
703.195982 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
703.195982 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.102.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
703.195982 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 102 -
703.195982 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.102.5. Wait: None
703.205982 1 Waited for 10.000 ms -
20.102.6. Wait 10ms: None
703.215982 1 Waited for 10.000 ms -
20.103. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 103)
20.103.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
703.215982 Diagnostic request 0x11, 0x01 -
703.217276 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.29466ms (max=1000ms) -
703.217276 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
703.226033 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.75655ms (max=1200ms) -
703.226033 Get Diagnostic Response Positive response was received. -
703.226033 Diagnostic response 0x51, 0x01 -
703.226033 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.103.2. (In for loop)Wait for the diagnostics to start: None
705.626033 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.103.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
705.626033 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
705.627518 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.485ms (max=1000ms) -
705.627518 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
705.641257 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.7395ms (max=1200ms) -
705.641257 Get Diagnostic Response Positive response was received. -
705.641257 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
705.641257 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.103.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
705.641257 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 103 -
705.641257 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.103.5. Wait: None
705.651257 1 Waited for 10.000 ms -
20.103.6. Wait 10ms: None
705.661257 1 Waited for 10.000 ms -
20.104. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 104)
20.104.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
705.661257 Diagnostic request 0x11, 0x01 -
705.662740 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.48258ms (max=1000ms) -
705.662740 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
705.671308 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.56858ms (max=1200ms) -
705.671308 Get Diagnostic Response Positive response was received. -
705.671308 Diagnostic response 0x51, 0x01 -
705.671308 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.104.2. (In for loop)Wait for the diagnostics to start: None
708.071308 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.104.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
708.071308 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
708.072808 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.49933ms (max=1000ms) -
708.072808 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
708.086509 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.7015ms (max=1200ms) -
708.086509 Get Diagnostic Response Positive response was received. -
708.086509 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
708.086509 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.104.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
708.086509 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 104 -
708.086509 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.104.5. Wait: None
708.096509 1 Waited for 10.000 ms -
20.104.6. Wait 10ms: None
708.106509 1 Waited for 10.000 ms -
20.105. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 105)
20.105.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
708.106509 Diagnostic request 0x11, 0x01 -
708.107942 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.43255ms (max=1000ms) -
708.107942 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
708.116564 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.62253ms (max=1200ms) -
708.116564 Get Diagnostic Response Positive response was received. -
708.116564 Diagnostic response 0x51, 0x01 -
708.116564 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.105.2. (In for loop)Wait for the diagnostics to start: None
710.516564 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.105.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
710.516564 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
710.518033 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.469ms (max=1000ms) -
710.518033 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
710.531729 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.6955ms (max=1200ms) -
710.531729 Get Diagnostic Response Positive response was received. -
710.531729 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
710.531729 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.105.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
710.531729 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 105 -
710.531729 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.105.5. Wait: None
710.541729 1 Waited for 10.000 ms -
20.105.6. Wait 10ms: None
710.551729 1 Waited for 10.000 ms -
20.106. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 106)
20.106.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
710.551729 Diagnostic request 0x11, 0x01 -
710.553097 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.36858ms (max=1000ms) -
710.553097 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
710.561776 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.67853ms (max=1200ms) -
710.561776 Get Diagnostic Response Positive response was received. -
710.561776 Diagnostic response 0x51, 0x01 -
710.561776 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.106.2. (In for loop)Wait for the diagnostics to start: None
712.961776 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.106.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
712.961776 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
712.963260 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.48464ms (max=1000ms) -
712.963260 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
712.976910 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.6495ms (max=1200ms) -
712.976910 Get Diagnostic Response Positive response was received. -
712.976910 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
712.976910 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.106.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
712.976910 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 106 -
712.976910 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.106.5. Wait: None
712.986910 1 Waited for 10.000 ms -
20.106.6. Wait 10ms: None
712.996910 1 Waited for 10.000 ms -
20.107. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 107)
20.107.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
712.996910 Diagnostic request 0x11, 0x01 -
712.998198 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.28856ms (max=1000ms) -
712.998198 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
713.006963 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.76444ms (max=1200ms) -
713.006963 Get Diagnostic Response Positive response was received. -
713.006963 Diagnostic response 0x51, 0x01 -
713.006963 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.107.2. (In for loop)Wait for the diagnostics to start: None
715.406963 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.107.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
715.406963 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
715.408385 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.42225ms (max=1000ms) -
715.408385 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
715.422083 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.6975ms (max=1200ms) -
715.422083 Get Diagnostic Response Positive response was received. -
715.422083 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
715.422083 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.107.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
715.422083 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 107 -
715.422083 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.107.5. Wait: None
715.432083 1 Waited for 10.000 ms -
20.107.6. Wait 10ms: None
715.442083 1 Waited for 10.000 ms -
20.108. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 108)
20.108.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
715.442083 Diagnostic request 0x11, 0x01 -
715.443373 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.29055ms (max=1000ms) -
715.443373 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
715.452137 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.76406ms (max=1200ms) -
715.452137 Get Diagnostic Response Positive response was received. -
715.452137 Diagnostic response 0x51, 0x01 -
715.452137 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.108.2. (In for loop)Wait for the diagnostics to start: None
717.852137 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.108.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
717.852137 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
717.853536 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.39822ms (max=1000ms) -
717.853536 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
717.867363 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.8275ms (max=1200ms) -
717.867363 Get Diagnostic Response Positive response was received. -
717.867363 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
717.867363 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.108.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
717.867363 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 108 -
717.867363 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.108.5. Wait: None
717.877363 1 Waited for 10.000 ms -
20.108.6. Wait 10ms: None
717.887363 1 Waited for 10.000 ms -
20.109. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 109)
20.109.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
717.887363 Diagnostic request 0x11, 0x01 -
717.888772 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.40858ms (max=1000ms) -
717.888772 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
717.897421 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.64956ms (max=1200ms) -
717.897421 Get Diagnostic Response Positive response was received. -
717.897421 Diagnostic response 0x51, 0x01 -
717.897421 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.109.2. (In for loop)Wait for the diagnostics to start: None
720.297421 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.109.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
720.297421 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
720.298982 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.56091ms (max=1000ms) -
720.298982 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
720.312736 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.7535ms (max=1200ms) -
720.312736 Get Diagnostic Response Positive response was received. -
720.312736 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
720.312736 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.109.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
720.312736 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 109 -
720.312736 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.109.5. Wait: None
720.322736 1 Waited for 10.000 ms -
20.109.6. Wait 10ms: None
720.332736 1 Waited for 10.000 ms -
20.110. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 110)
20.110.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
720.332736 Diagnostic request 0x11, 0x01 -
720.334156 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.42056ms (max=1000ms) -
720.334156 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
720.342788 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.63159ms (max=1200ms) -
720.342788 Get Diagnostic Response Positive response was received. -
720.342788 Diagnostic response 0x51, 0x01 -
720.342788 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.110.2. (In for loop)Wait for the diagnostics to start: None
722.742788 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.110.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
722.742788 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
722.744217 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.42958ms (max=1000ms) -
722.744217 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
722.757935 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.7175ms (max=1200ms) -
722.757935 Get Diagnostic Response Positive response was received. -
722.757935 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
722.757935 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.110.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
722.757935 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 110 -
722.757935 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.110.5. Wait: None
722.767935 1 Waited for 10.000 ms -
20.110.6. Wait 10ms: None
722.777935 1 Waited for 10.000 ms -
20.111. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 111)
20.111.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
722.777935 Diagnostic request 0x11, 0x01 -
722.779231 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.29656ms (max=1000ms) -
722.779231 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
722.787985 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.75353ms (max=1200ms) -
722.787985 Get Diagnostic Response Positive response was received. -
722.787985 Diagnostic response 0x51, 0x01 -
722.787985 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.111.2. (In for loop)Wait for the diagnostics to start: None
725.187985 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.111.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
725.187985 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
725.189399 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.41427ms (max=1000ms) -
725.189399 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
725.203189 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.7895ms (max=1200ms) -
725.203189 Get Diagnostic Response Positive response was received. -
725.203189 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
725.203189 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.111.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
725.203189 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 111 -
725.203189 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.111.5. Wait: None
725.213189 1 Waited for 10.000 ms -
20.111.6. Wait 10ms: None
725.223189 1 Waited for 10.000 ms -
20.112. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 112)
20.112.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
725.223189 Diagnostic request 0x11, 0x01 -
725.224441 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.25258ms (max=1000ms) -
725.224441 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
725.233183 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.74156ms (max=1200ms) -
725.233183 Get Diagnostic Response Positive response was received. -
725.233183 Diagnostic response 0x51, 0x01 -
725.233183 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.112.2. (In for loop)Wait for the diagnostics to start: None
727.633183 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.112.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
727.633183 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
727.634606 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.42311ms (max=1000ms) -
727.634606 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
727.648301 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.6955ms (max=1200ms) -
727.648301 Get Diagnostic Response Positive response was received. -
727.648301 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
727.648301 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.112.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
727.648301 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 112 -
727.648301 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.112.5. Wait: None
727.658301 1 Waited for 10.000 ms -
20.112.6. Wait 10ms: None
727.668301 1 Waited for 10.000 ms -
20.113. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 113)
20.113.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
727.668301 Diagnostic request 0x11, 0x01 -
727.669736 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.43456ms (max=1000ms) -
727.669736 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
727.678359 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.62258ms (max=1200ms) -
727.678359 Get Diagnostic Response Positive response was received. -
727.678359 Diagnostic response 0x51, 0x01 -
727.678359 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.113.2. (In for loop)Wait for the diagnostics to start: None
730.078359 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.113.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
730.078359 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
730.079950 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.59159ms (max=1000ms) -
730.079950 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
730.093532 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.5815ms (max=1200ms) -
730.093532 Get Diagnostic Response Positive response was received. -
730.093532 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
730.093532 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.113.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
730.093532 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 113 -
730.093532 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.113.5. Wait: None
730.103532 1 Waited for 10.000 ms -
20.113.6. Wait 10ms: None
730.113532 1 Waited for 10.000 ms -
20.114. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 114)
20.114.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
730.113532 Diagnostic request 0x11, 0x01 -
730.114896 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.36458ms (max=1000ms) -
730.114896 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
730.123586 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.68953ms (max=1200ms) -
730.123586 Get Diagnostic Response Positive response was received. -
730.123586 Diagnostic response 0x51, 0x01 -
730.123586 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.114.2. (In for loop)Wait for the diagnostics to start: None
732.523586 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.114.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
732.523586 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
732.525086 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.50066ms (max=1000ms) -
732.525086 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
732.538726 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.6395ms (max=1200ms) -
732.538726 Get Diagnostic Response Positive response was received. -
732.538726 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
732.538726 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.114.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
732.538726 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 114 -
732.538726 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.114.5. Wait: None
732.548726 1 Waited for 10.000 ms -
20.114.6. Wait 10ms: None
732.558726 1 Waited for 10.000 ms -
20.115. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 115)
20.115.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
732.558726 Diagnostic request 0x11, 0x01 -
732.560082 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.35655ms (max=1000ms) -
732.560082 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
732.568778 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.69558ms (max=1200ms) -
732.568778 Get Diagnostic Response Positive response was received. -
732.568778 Diagnostic response 0x51, 0x01 -
732.568778 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.115.2. (In for loop)Wait for the diagnostics to start: None
734.968778 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.115.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
734.968778 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
734.970285 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.50745ms (max=1000ms) -
734.970285 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
734.983967 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.6815ms (max=1200ms) -
734.983967 Get Diagnostic Response Positive response was received. -
734.983967 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
734.983967 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.115.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
734.983967 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 115 -
734.983967 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.115.5. Wait: None
734.993967 1 Waited for 10.000 ms -
20.115.6. Wait 10ms: None
735.003967 1 Waited for 10.000 ms -
20.116. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 116)
20.116.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
735.003967 Diagnostic request 0x11, 0x01 -
735.005240 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.27295ms (max=1000ms) -
735.005240 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
735.014021 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.78155ms (max=1200ms) -
735.014021 Get Diagnostic Response Positive response was received. -
735.014021 Diagnostic response 0x51, 0x01 -
735.014021 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.116.2. (In for loop)Wait for the diagnostics to start: None
737.414021 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.116.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
737.414021 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
737.415430 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.40877ms (max=1000ms) -
737.415430 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
737.429078 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.6475ms (max=1200ms) -
737.429078 Get Diagnostic Response Positive response was received. -
737.429078 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
737.429078 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.116.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
737.429078 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 116 -
737.429078 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.116.5. Wait: None
737.439078 1 Waited for 10.000 ms -
20.116.6. Wait 10ms: None
737.449078 1 Waited for 10.000 ms -
20.117. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 117)
20.117.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
737.449078 Diagnostic request 0x11, 0x01 -
737.450350 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.27258ms (max=1000ms) -
737.450350 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
737.459129 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.77858ms (max=1200ms) -
737.459129 Get Diagnostic Response Positive response was received. -
737.459129 Diagnostic response 0x51, 0x01 -
737.459129 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.117.2. (In for loop)Wait for the diagnostics to start: None
739.859129 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.117.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
739.859129 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
739.860510 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.38116ms (max=1000ms) -
739.860510 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
739.874285 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.7755ms (max=1200ms) -
739.874285 Get Diagnostic Response Positive response was received. -
739.874285 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
739.874285 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.117.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
739.874285 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 117 -
739.874285 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.117.5. Wait: None
739.884285 1 Waited for 10.000 ms -
20.117.6. Wait 10ms: None
739.894285 1 Waited for 10.000 ms -
20.118. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 118)
20.118.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
739.894285 Diagnostic request 0x11, 0x01 -
739.895792 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.50656ms (max=1000ms) -
739.895792 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
739.904340 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.54753ms (max=1200ms) -
739.904340 Get Diagnostic Response Positive response was received. -
739.904340 Diagnostic response 0x51, 0x01 -
739.904340 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.118.2. (In for loop)Wait for the diagnostics to start: None
742.304340 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.118.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
742.304340 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
742.305969 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.62972ms (max=1000ms) -
742.305969 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
742.319529 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.5595ms (max=1200ms) -
742.319529 Get Diagnostic Response Positive response was received. -
742.319529 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
742.319529 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.118.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
742.319529 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 118 -
742.319529 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.118.5. Wait: None
742.329529 1 Waited for 10.000 ms -
20.118.6. Wait 10ms: None
742.339529 1 Waited for 10.000 ms -
20.119. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 119)
20.119.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
742.339529 Diagnostic request 0x11, 0x01 -
742.340941 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.41256ms (max=1000ms) -
742.340941 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
742.349581 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.63952ms (max=1200ms) -
742.349581 Get Diagnostic Response Positive response was received. -
742.349581 Diagnostic response 0x51, 0x01 -
742.349581 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.119.2. (In for loop)Wait for the diagnostics to start: None
744.749581 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.119.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
744.749581 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
744.751180 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.59903ms (max=1000ms) -
744.751180 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
744.764749 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.5695ms (max=1200ms) -
744.764749 Get Diagnostic Response Positive response was received. -
744.764749 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
744.764749 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.119.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
744.764749 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 119 -
744.764749 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.119.5. Wait: None
744.774749 1 Waited for 10.000 ms -
20.119.6. Wait 10ms: None
744.784749 1 Waited for 10.000 ms -
20.120. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 120)
20.120.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
744.784749 Diagnostic request 0x11, 0x01 -
744.786148 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.39858ms (max=1000ms) -
744.786148 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
744.794803 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.65553ms (max=1200ms) -
744.794803 Get Diagnostic Response Positive response was received. -
744.794803 Diagnostic response 0x51, 0x01 -
744.794803 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.120.2. (In for loop)Wait for the diagnostics to start: None
747.194803 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.120.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
747.194803 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
747.196331 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.52778ms (max=1000ms) -
747.196331 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
747.210033 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.7019ms (max=1200ms) -
747.210033 Get Diagnostic Response Positive response was received. -
747.210033 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
747.210033 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.120.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
747.210033 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 120 -
747.210033 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.120.5. Wait: None
747.220033 1 Waited for 10.000 ms -
20.120.6. Wait 10ms: None
747.230033 1 Waited for 10.000 ms -
20.121. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 121)
20.121.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
747.230033 Diagnostic request 0x11, 0x01 -
747.231536 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.50258ms (max=1000ms) -
747.231536 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
747.240096 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.56005ms (max=1200ms) -
747.240096 Get Diagnostic Response Positive response was received. -
747.240096 Diagnostic response 0x51, 0x01 -
747.240096 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.121.2. (In for loop)Wait for the diagnostics to start: None
749.640096 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.121.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
749.640096 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
749.641628 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.53188ms (max=1000ms) -
749.641628 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
749.655259 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.6315ms (max=1200ms) -
749.655259 Get Diagnostic Response Positive response was received. -
749.655259 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
749.655259 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.121.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
749.655259 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 121 -
749.655259 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.121.5. Wait: None
749.665259 1 Waited for 10.000 ms -
20.121.6. Wait 10ms: None
749.675259 1 Waited for 10.000 ms -
20.122. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 122)
20.122.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
749.675259 Diagnostic request 0x11, 0x01 -
749.676714 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.45456ms (max=1000ms) -
749.676714 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
749.685311 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.59753ms (max=1200ms) -
749.685311 Get Diagnostic Response Positive response was received. -
749.685311 Diagnostic response 0x51, 0x01 -
749.685311 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.122.2. (In for loop)Wait for the diagnostics to start: None
752.085311 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.122.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
752.085311 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
752.086953 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.64166ms (max=1000ms) -
752.086953 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
752.100498 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.5455ms (max=1200ms) -
752.100498 Get Diagnostic Response Positive response was received. -
752.100498 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
752.100498 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.122.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
752.100498 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 122 -
752.100498 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.122.5. Wait: None
752.110498 1 Waited for 10.000 ms -
20.122.6. Wait 10ms: None
752.120498 1 Waited for 10.000 ms -
20.123. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 123)
20.123.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
752.120498 Diagnostic request 0x11, 0x01 -
752.121933 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.43458ms (max=1000ms) -
752.121933 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
752.130550 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.61753ms (max=1200ms) -
752.130550 Get Diagnostic Response Positive response was received. -
752.130550 Diagnostic response 0x51, 0x01 -
752.130550 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.123.2. (In for loop)Wait for the diagnostics to start: None
754.530550 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.123.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
754.530550 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
754.532093 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.54273ms (max=1000ms) -
754.532093 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
754.545769 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.6755ms (max=1200ms) -
754.545769 Get Diagnostic Response Positive response was received. -
754.545769 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
754.545769 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.123.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
754.545769 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 123 -
754.545769 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.123.5. Wait: None
754.555769 1 Waited for 10.000 ms -
20.123.6. Wait 10ms: None
754.565769 1 Waited for 10.000 ms -
20.124. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 124)
20.124.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
754.565769 Diagnostic request 0x11, 0x01 -
754.567203 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.43456ms (max=1000ms) -
754.567203 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
754.575823 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.61956ms (max=1200ms) -
754.575823 Get Diagnostic Response Positive response was received. -
754.575823 Diagnostic response 0x51, 0x01 -
754.575823 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.124.2. (In for loop)Wait for the diagnostics to start: None
756.975823 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.124.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
756.975823 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
756.977321 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.49858ms (max=1000ms) -
756.977321 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
756.991037 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.7155ms (max=1200ms) -
756.991037 Get Diagnostic Response Positive response was received. -
756.991037 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
756.991037 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.124.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
756.991037 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 124 -
756.991037 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.124.5. Wait: None
757.001037 1 Waited for 10.000 ms -
20.124.6. Wait 10ms: None
757.011037 1 Waited for 10.000 ms -
20.125. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 125)
20.125.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
757.011037 Diagnostic request 0x11, 0x01 -
757.012456 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.41867ms (max=1000ms) -
757.012456 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
757.021091 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.63556ms (max=1200ms) -
757.021091 Get Diagnostic Response Positive response was received. -
757.021091 Diagnostic response 0x51, 0x01 -
757.021091 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.125.2. (In for loop)Wait for the diagnostics to start: None
759.421091 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.125.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
759.421091 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
759.422503 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.41167ms (max=1000ms) -
759.422503 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
759.436294 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.7915ms (max=1200ms) -
759.436294 Get Diagnostic Response Positive response was received. -
759.436294 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
759.436294 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.125.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
759.436294 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 125 -
759.436294 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.125.5. Wait: None
759.446294 1 Waited for 10.000 ms -
20.125.6. Wait 10ms: None
759.456294 1 Waited for 10.000 ms -
20.126. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 126)
20.126.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
759.456294 Diagnostic request 0x11, 0x01 -
759.457747 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.45256ms (max=1000ms) -
759.457747 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
759.466345 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.59808ms (max=1200ms) -
759.466345 Get Diagnostic Response Positive response was received. -
759.466345 Diagnostic response 0x51, 0x01 -
759.466345 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.126.2. (In for loop)Wait for the diagnostics to start: None
761.866345 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.126.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
761.866345 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
761.867857 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.51188ms (max=1000ms) -
761.867857 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
761.881408 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.5515ms (max=1200ms) -
761.881408 Get Diagnostic Response Positive response was received. -
761.881408 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
761.881408 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.126.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
761.881408 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 126 -
761.881408 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.126.5. Wait: None
761.891408 1 Waited for 10.000 ms -
20.126.6. Wait 10ms: None
761.901408 1 Waited for 10.000 ms -
20.127. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 127)
20.127.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
761.901408 Diagnostic request 0x11, 0x01 -
761.902871 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.46258ms (max=1000ms) -
761.902871 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
761.911460 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.58956ms (max=1200ms) -
761.911460 Get Diagnostic Response Positive response was received. -
761.911460 Diagnostic response 0x51, 0x01 -
761.911460 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.127.2. (In for loop)Wait for the diagnostics to start: None
764.311460 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.127.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
764.311460 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
764.312947 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.48661ms (max=1000ms) -
764.312947 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
764.326479 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.5315ms (max=1200ms) -
764.326479 Get Diagnostic Response Positive response was received. -
764.326479 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
764.326479 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.127.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
764.326479 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 127 -
764.326479 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.127.5. Wait: None
764.336479 1 Waited for 10.000 ms -
20.127.6. Wait 10ms: None
764.346479 1 Waited for 10.000 ms -
20.128. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 128)
20.128.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
764.346479 Diagnostic request 0x11, 0x01 -
764.347875 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.39658ms (max=1000ms) -
764.347875 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
764.356533 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.65755ms (max=1200ms) -
764.356533 Get Diagnostic Response Positive response was received. -
764.356533 Diagnostic response 0x51, 0x01 -
764.356533 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.128.2. (In for loop)Wait for the diagnostics to start: None
766.756533 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.128.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
766.756533 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
766.758028 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.49562ms (max=1000ms) -
766.758028 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
766.771670 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.6415ms (max=1200ms) -
766.771670 Get Diagnostic Response Positive response was received. -
766.771670 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
766.771670 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.128.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
766.771670 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 128 -
766.771670 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.128.5. Wait: None
766.781670 1 Waited for 10.000 ms -
20.128.6. Wait 10ms: None
766.791670 1 Waited for 10.000 ms -
20.129. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 129)
20.129.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
766.791670 Diagnostic request 0x11, 0x01 -
766.793054 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.38458ms (max=1000ms) -
766.793054 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
766.801782 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.72759ms (max=1200ms) -
766.801782 Get Diagnostic Response Positive response was received. -
766.801782 Diagnostic response 0x51, 0x01 -
766.801782 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.129.2. (In for loop)Wait for the diagnostics to start: None
769.201782 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.129.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
769.201782 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
769.203272 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.49045ms (max=1000ms) -
769.203272 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
769.216856 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.5835ms (max=1200ms) -
769.216856 Get Diagnostic Response Positive response was received. -
769.216856 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
769.216856 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.129.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
769.216856 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 129 -
769.216856 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.129.5. Wait: None
769.226856 1 Waited for 10.000 ms -
20.129.6. Wait 10ms: None
769.236856 1 Waited for 10.000 ms -
20.130. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 130)
20.130.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
769.236856 Diagnostic request 0x11, 0x01 -
769.238220 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.36456ms (max=1000ms) -
769.238220 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
769.246906 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.68555ms (max=1200ms) -
769.246906 Get Diagnostic Response Positive response was received. -
769.246906 Diagnostic response 0x51, 0x01 -
769.246906 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.130.2. (In for loop)Wait for the diagnostics to start: None
771.646906 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.130.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
771.646906 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
771.648386 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.47961ms (max=1000ms) -
771.648386 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
771.662125 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.7395ms (max=1200ms) -
771.662125 Get Diagnostic Response Positive response was received. -
771.662125 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
771.662125 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.130.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
771.662125 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 130 -
771.662125 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.130.5. Wait: None
771.672125 1 Waited for 10.000 ms -
20.130.6. Wait 10ms: None
771.682125 1 Waited for 10.000 ms -
20.131. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 131)
20.131.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
771.682125 Diagnostic request 0x11, 0x01 -
771.683420 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.29456ms (max=1000ms) -
771.683420 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
771.692175 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.75505ms (max=1200ms) -
771.692175 Get Diagnostic Response Positive response was received. -
771.692175 Diagnostic response 0x51, 0x01 -
771.692175 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.131.2. (In for loop)Wait for the diagnostics to start: None
774.092175 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.131.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
774.092175 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
774.093576 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.40111ms (max=1000ms) -
774.093576 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
774.107267 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.6915ms (max=1200ms) -
774.107267 Get Diagnostic Response Positive response was received. -
774.107267 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
774.107267 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.131.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
774.107267 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 131 -
774.107267 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.131.5. Wait: None
774.117267 1 Waited for 10.000 ms -
20.131.6. Wait 10ms: None
774.127267 1 Waited for 10.000 ms -
20.132. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 132)
20.132.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
774.127267 Diagnostic request 0x11, 0x01 -
774.128638 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.37058ms (max=1000ms) -
774.128638 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
774.137321 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.68303ms (max=1200ms) -
774.137321 Get Diagnostic Response Positive response was received. -
774.137321 Diagnostic response 0x51, 0x01 -
774.137321 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.132.2. (In for loop)Wait for the diagnostics to start: None
776.537321 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.132.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
776.537321 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
776.538828 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.50717ms (max=1000ms) -
776.538828 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
776.552394 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.5655ms (max=1200ms) -
776.552394 Get Diagnostic Response Positive response was received. -
776.552394 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
776.552394 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.132.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
776.552394 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 132 -
776.552394 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.132.5. Wait: None
776.562394 1 Waited for 10.000 ms -
20.132.6. Wait 10ms: None
776.572394 1 Waited for 10.000 ms -
20.133. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 133)
20.133.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
776.572394 Diagnostic request 0x11, 0x01 -
776.573740 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.34658ms (max=1000ms) -
776.573740 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
776.582449 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.70853ms (max=1200ms) -
776.582449 Get Diagnostic Response Positive response was received. -
776.582449 Diagnostic response 0x51, 0x01 -
776.582449 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.133.2. (In for loop)Wait for the diagnostics to start: None
778.982449 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.133.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
778.982449 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
778.983913 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.46433ms (max=1000ms) -
778.983913 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
778.997626 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.7135ms (max=1200ms) -
778.997626 Get Diagnostic Response Positive response was received. -
778.997626 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
778.997626 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.133.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
778.997626 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 133 -
778.997626 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.133.5. Wait: None
779.007626 1 Waited for 10.000 ms -
20.133.6. Wait 10ms: None
779.017626 1 Waited for 10.000 ms -
20.134. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 134)
20.134.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
779.017626 Diagnostic request 0x11, 0x01 -
779.019011 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.38462ms (max=1000ms) -
779.019011 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
779.027681 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.66953ms (max=1200ms) -
779.027681 Get Diagnostic Response Positive response was received. -
779.027681 Diagnostic response 0x51, 0x01 -
779.027681 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.134.2. (In for loop)Wait for the diagnostics to start: None
781.427681 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.134.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
781.427681 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
781.429180 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.49964ms (max=1000ms) -
781.429180 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
781.442894 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.7135ms (max=1200ms) -
781.442894 Get Diagnostic Response Positive response was received. -
781.442894 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
781.442894 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.134.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
781.442894 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 134 -
781.442894 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.134.5. Wait: None
781.452894 1 Waited for 10.000 ms -
20.134.6. Wait 10ms: None
781.462894 1 Waited for 10.000 ms -
20.135. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 135)
20.135.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
781.462894 Diagnostic request 0x11, 0x01 -
781.464208 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.31458ms (max=1000ms) -
781.464208 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
781.472943 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.73506ms (max=1200ms) -
781.472943 Get Diagnostic Response Positive response was received. -
781.472943 Diagnostic response 0x51, 0x01 -
781.472943 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.135.2. (In for loop)Wait for the diagnostics to start: None
783.872943 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.135.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
783.872943 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
783.874448 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.5042ms (max=1000ms) -
783.874448 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
783.888079 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.6315ms (max=1200ms) -
783.888079 Get Diagnostic Response Positive response was received. -
783.888079 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
783.888079 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.135.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
783.888079 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 135 -
783.888079 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.135.5. Wait: None
783.898079 1 Waited for 10.000 ms -
20.135.6. Wait 10ms: None
783.908079 1 Waited for 10.000 ms -
20.136. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 136)
20.136.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
783.908079 Diagnostic request 0x11, 0x01 -
783.909328 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.24858ms (max=1000ms) -
783.909328 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
783.918131 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.80305ms (max=1200ms) -
783.918131 Get Diagnostic Response Positive response was received. -
783.918131 Diagnostic response 0x51, 0x01 -
783.918131 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.136.2. (In for loop)Wait for the diagnostics to start: None
786.318131 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.136.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
786.318131 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
786.319483 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.35192ms (max=1000ms) -
786.319483 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
786.333280 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.7975ms (max=1200ms) -
786.333280 Get Diagnostic Response Positive response was received. -
786.333280 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
786.333280 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.136.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
786.333280 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 136 -
786.333280 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.136.5. Wait: None
786.343280 1 Waited for 10.000 ms -
20.136.6. Wait 10ms: None
786.353280 1 Waited for 10.000 ms -
20.137. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 137)
20.137.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
786.353280 Diagnostic request 0x11, 0x01 -
786.354653 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.37258ms (max=1000ms) -
786.354653 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
786.363336 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.68353ms (max=1200ms) -
786.363336 Get Diagnostic Response Positive response was received. -
786.363336 Diagnostic response 0x51, 0x01 -
786.363336 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.137.2. (In for loop)Wait for the diagnostics to start: None
788.763336 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.137.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
788.763336 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
788.764965 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.6285ms (max=1000ms) -
788.764965 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
788.778494 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.5295ms (max=1200ms) -
788.778494 Get Diagnostic Response Positive response was received. -
788.778494 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
788.778494 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.137.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
788.778494 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 137 -
788.778494 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.137.5. Wait: None
788.788494 1 Waited for 10.000 ms -
20.137.6. Wait 10ms: None
788.798494 1 Waited for 10.000 ms -
20.138. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 138)
20.138.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
788.798494 Diagnostic request 0x11, 0x01 -
788.799787 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.29259ms (max=1000ms) -
788.799787 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
788.808549 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.76194ms (max=1200ms) -
788.808549 Get Diagnostic Response Positive response was received. -
788.808549 Diagnostic response 0x51, 0x01 -
788.808549 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.138.2. (In for loop)Wait for the diagnostics to start: None
791.208549 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.138.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
791.208549 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
791.210083 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.53445ms (max=1000ms) -
791.210083 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
791.223687 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.6035ms (max=1200ms) -
791.223687 Get Diagnostic Response Positive response was received. -
791.223687 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
791.223687 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.138.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
791.223687 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 138 -
791.223687 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.138.5. Wait: None
791.233687 1 Waited for 10.000 ms -
20.138.6. Wait 10ms: None
791.243687 1 Waited for 10.000 ms -
20.139. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 139)
20.139.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
791.243687 Diagnostic request 0x11, 0x01 -
791.245055 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.36858ms (max=1000ms) -
791.245055 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
791.253743 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.68755ms (max=1200ms) -
791.253743 Get Diagnostic Response Positive response was received. -
791.253743 Diagnostic response 0x51, 0x01 -
791.253743 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.139.2. (In for loop)Wait for the diagnostics to start: None
793.653743 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.139.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
793.653743 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
793.655317 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.57444ms (max=1000ms) -
793.655317 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
793.668987 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.6695ms (max=1200ms) -
793.668987 Get Diagnostic Response Positive response was received. -
793.668987 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
793.668987 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.139.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
793.668987 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 139 -
793.668987 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.139.5. Wait: None
793.678987 1 Waited for 10.000 ms -
20.139.6. Wait 10ms: None
793.688987 1 Waited for 10.000 ms -
20.140. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 140)
20.140.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
793.688987 Diagnostic request 0x11, 0x01 -
793.690299 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.31256ms (max=1000ms) -
793.690299 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
793.699038 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.73859ms (max=1200ms) -
793.699038 Get Diagnostic Response Positive response was received. -
793.699038 Diagnostic response 0x51, 0x01 -
793.699038 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.140.2. (In for loop)Wait for the diagnostics to start: None
796.099038 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.140.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
796.099038 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
796.100553 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.51539ms (max=1000ms) -
796.100553 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
796.114239 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.6855ms (max=1200ms) -
796.114239 Get Diagnostic Response Positive response was received. -
796.114239 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
796.114239 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.140.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
796.114239 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 140 -
796.114239 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.140.5. Wait: None
796.124239 1 Waited for 10.000 ms -
20.140.6. Wait 10ms: None
796.134239 1 Waited for 10.000 ms -
20.141. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 141)
20.141.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
796.134239 Diagnostic request 0x11, 0x01 -
796.135485 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.24659ms (max=1000ms) -
796.135485 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
796.144296 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.81052ms (max=1200ms) -
796.144296 Get Diagnostic Response Positive response was received. -
796.144296 Diagnostic response 0x51, 0x01 -
796.144296 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.141.2. (In for loop)Wait for the diagnostics to start: None
798.544296 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.141.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
798.544296 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
798.545856 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.5605ms (max=1000ms) -
798.545856 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
798.559342 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.4855ms (max=1200ms) -
798.559342 Get Diagnostic Response Positive response was received. -
798.559342 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
798.559342 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.141.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
798.559342 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 141 -
798.559342 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.141.5. Wait: None
798.569342 1 Waited for 10.000 ms -
20.141.6. Wait 10ms: None
798.579342 1 Waited for 10.000 ms -
20.142. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 142)
20.142.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
798.579342 Diagnostic request 0x11, 0x01 -
798.581060 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.71856ms (max=1000ms) -
798.581060 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
798.589395 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.33456ms (max=1200ms) -
798.589395 Get Diagnostic Response Positive response was received. -
798.589395 Diagnostic response 0x51, 0x01 -
798.589395 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.142.2. (In for loop)Wait for the diagnostics to start: None
800.989395 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.142.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
800.989395 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
800.990971 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.57647ms (max=1000ms) -
800.990971 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
801.004605 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.6335ms (max=1200ms) -
801.004605 Get Diagnostic Response Positive response was received. -
801.004605 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
801.004605 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.142.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
801.004605 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 142 -
801.004605 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.142.5. Wait: None
801.014605 1 Waited for 10.000 ms -
20.142.6. Wait 10ms: None
801.024605 1 Waited for 10.000 ms -
20.143. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 143)
20.143.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
801.024605 Diagnostic request 0x11, 0x01 -
801.026005 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.40056ms (max=1000ms) -
801.026005 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
801.034594 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.58855ms (max=1200ms) -
801.034594 Get Diagnostic Response Positive response was received. -
801.034594 Diagnostic response 0x51, 0x01 -
801.034594 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.143.2. (In for loop)Wait for the diagnostics to start: None
803.434594 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.143.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
803.434594 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
803.436154 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.56008ms (max=1000ms) -
803.436154 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
803.449770 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.6155ms (max=1200ms) -
803.449770 Get Diagnostic Response Positive response was received. -
803.449770 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
803.449770 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.143.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
803.449770 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 143 -
803.449770 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.143.5. Wait: None
803.459770 1 Waited for 10.000 ms -
20.143.6. Wait 10ms: None
803.469770 1 Waited for 10.000 ms -
20.144. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 144)
20.144.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
803.469770 Diagnostic request 0x11, 0x01 -
803.471134 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.36456ms (max=1000ms) -
803.471134 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
803.479824 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.69005ms (max=1200ms) -
803.479824 Get Diagnostic Response Positive response was received. -
803.479824 Diagnostic response 0x51, 0x01 -
803.479824 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.144.2. (In for loop)Wait for the diagnostics to start: None
805.879824 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.144.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
805.879824 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
805.881446 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.62205ms (max=1000ms) -
805.881446 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
805.895070 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.6235ms (max=1200ms) -
805.895070 Get Diagnostic Response Positive response was received. -
805.895070 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
805.895070 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.144.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
805.895070 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 144 -
805.895070 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.144.5. Wait: None
805.905070 1 Waited for 10.000 ms -
20.144.6. Wait 10ms: None
805.915070 1 Waited for 10.000 ms -
20.145. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 145)
20.145.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
805.915070 Diagnostic request 0x11, 0x01 -
805.916380 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.31059ms (max=1000ms) -
805.916380 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
805.925120 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.73955ms (max=1200ms) -
805.925120 Get Diagnostic Response Positive response was received. -
805.925120 Diagnostic response 0x51, 0x01 -
805.925120 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.145.2. (In for loop)Wait for the diagnostics to start: None
808.325120 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.145.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
808.325120 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
808.326546 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.42648ms (max=1000ms) -
808.326546 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
808.340286 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.7395ms (max=1200ms) -
808.340286 Get Diagnostic Response Positive response was received. -
808.340286 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
808.340286 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.145.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
808.340286 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 145 -
808.340286 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.145.5. Wait: None
808.350286 1 Waited for 10.000 ms -
20.145.6. Wait 10ms: None
808.360286 1 Waited for 10.000 ms -
20.146. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 146)
20.146.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
808.360286 Diagnostic request 0x11, 0x01 -
808.361752 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.46656ms (max=1000ms) -
808.361752 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
808.370344 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.59158ms (max=1200ms) -
808.370344 Get Diagnostic Response Positive response was received. -
808.370344 Diagnostic response 0x51, 0x01 -
808.370344 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.146.2. (In for loop)Wait for the diagnostics to start: None
810.770344 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.146.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
810.770344 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
810.771895 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.55064ms (max=1000ms) -
810.771895 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
810.785530 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.6355ms (max=1200ms) -
810.785530 Get Diagnostic Response Positive response was received. -
810.785530 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
810.785530 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.146.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
810.785530 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 146 -
810.785530 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.146.5. Wait: None
810.795530 1 Waited for 10.000 ms -
20.146.6. Wait 10ms: None
810.805530 1 Waited for 10.000 ms -
20.147. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 147)
20.147.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
810.805530 Diagnostic request 0x11, 0x01 -
810.807057 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.52692ms (max=1000ms) -
810.807057 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
810.815582 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.52456ms (max=1200ms) -
810.815582 Get Diagnostic Response Positive response was received. -
810.815582 Diagnostic response 0x51, 0x01 -
810.815582 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.147.2. (In for loop)Wait for the diagnostics to start: None
813.215582 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.147.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
813.215582 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
813.217088 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.50642ms (max=1000ms) -
813.217088 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
813.230746 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.6575ms (max=1200ms) -
813.230746 Get Diagnostic Response Positive response was received. -
813.230746 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
813.230746 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.147.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
813.230746 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 147 -
813.230746 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.147.5. Wait: None
813.240746 1 Waited for 10.000 ms -
20.147.6. Wait 10ms: None
813.250746 1 Waited for 10.000 ms -
20.148. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 148)
20.148.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
813.250746 Diagnostic request 0x11, 0x01 -
813.252112 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.36658ms (max=1000ms) -
813.252112 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
813.260800 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.68753ms (max=1200ms) -
813.260800 Get Diagnostic Response Positive response was received. -
813.260800 Diagnostic response 0x51, 0x01 -
813.260800 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.148.2. (In for loop)Wait for the diagnostics to start: None
815.660800 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.148.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
815.660800 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
815.662312 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.51189ms (max=1000ms) -
815.662312 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
815.675999 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.6875ms (max=1200ms) -
815.675999 Get Diagnostic Response Positive response was received. -
815.675999 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
815.675999 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.148.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
815.675999 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 148 -
815.675999 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.148.5. Wait: None
815.685999 1 Waited for 10.000 ms -
20.148.6. Wait 10ms: None
815.695999 1 Waited for 10.000 ms -
20.149. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 149)
20.149.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
815.695999 Diagnostic request 0x11, 0x01 -
815.697330 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.33056ms (max=1000ms) -
815.697330 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
815.706049 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.71955ms (max=1200ms) -
815.706049 Get Diagnostic Response Positive response was received. -
815.706049 Diagnostic response 0x51, 0x01 -
815.706049 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.149.2. (In for loop)Wait for the diagnostics to start: None
818.106049 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.149.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
818.106049 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
818.107523 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.47367ms (max=1000ms) -
818.107523 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
818.121246 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.7235ms (max=1200ms) -
818.121246 Get Diagnostic Response Positive response was received. -
818.121246 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
818.121246 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.149.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
818.121246 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 149 -
818.121246 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.149.5. Wait: None
818.131246 1 Waited for 10.000 ms -
20.149.6. Wait 10ms: None
818.141246 1 Waited for 10.000 ms -
20.150. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 150)
20.150.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
818.141246 Diagnostic request 0x11, 0x01 -
818.142717 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.47055ms (max=1000ms) -
818.142717 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
818.151297 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.58059ms (max=1200ms) -
818.151297 Get Diagnostic Response Positive response was received. -
818.151297 Diagnostic response 0x51, 0x01 -
818.151297 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.150.2. (In for loop)Wait for the diagnostics to start: None
820.551297 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.150.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
820.551297 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
820.552848 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.55041ms (max=1000ms) -
820.552848 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
820.566401 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.5535ms (max=1200ms) -
820.566401 Get Diagnostic Response Positive response was received. -
820.566401 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
820.566401 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.150.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
820.566401 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 150 -
820.566401 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.150.5. Wait: None
820.576401 1 Waited for 10.000 ms -
20.150.6. Wait 10ms: None
820.586401 1 Waited for 10.000 ms -
20.151. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 151)
20.151.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
820.586401 Diagnostic request 0x11, 0x01 -
820.587854 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.45258ms (max=1000ms) -
820.587854 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
820.596456 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.60253ms (max=1200ms) -
820.596456 Get Diagnostic Response Positive response was received. -
820.596456 Diagnostic response 0x51, 0x01 -
820.596456 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.151.2. (In for loop)Wait for the diagnostics to start: None
822.996456 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.151.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
822.996456 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
822.997977 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.52055ms (max=1000ms) -
822.997977 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
823.011669 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.6919ms (max=1200ms) -
823.011669 Get Diagnostic Response Positive response was received. -
823.011669 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
823.011669 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.151.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
823.011669 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 151 -
823.011669 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.151.5. Wait: None
823.021669 1 Waited for 10.000 ms -
20.151.6. Wait 10ms: None
823.031669 1 Waited for 10.000 ms -
20.152. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 152)
20.152.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
823.031669 Diagnostic request 0x11, 0x01 -
823.033046 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.37656ms (max=1000ms) -
823.033046 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
823.041723 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.67755ms (max=1200ms) -
823.041723 Get Diagnostic Response Positive response was received. -
823.041723 Diagnostic response 0x51, 0x01 -
823.041723 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.152.2. (In for loop)Wait for the diagnostics to start: None
825.441723 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.152.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
825.441723 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
825.443231 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.5078ms (max=1000ms) -
825.443231 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
825.456834 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.6035ms (max=1200ms) -
825.456834 Get Diagnostic Response Positive response was received. -
825.456834 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
825.456834 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.152.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
825.456834 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 152 -
825.456834 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.152.5. Wait: None
825.466834 1 Waited for 10.000 ms -
20.152.6. Wait 10ms: None
825.476834 1 Waited for 10.000 ms -
20.153. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 153)
20.153.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
825.476834 Diagnostic request 0x11, 0x01 -
825.478257 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.42255ms (max=1000ms) -
825.478257 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
825.486890 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.63356ms (max=1200ms) -
825.486890 Get Diagnostic Response Positive response was received. -
825.486890 Diagnostic response 0x51, 0x01 -
825.486890 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.153.2. (In for loop)Wait for the diagnostics to start: None
827.886890 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.153.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
827.886890 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
827.888372 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.48142ms (max=1000ms) -
827.888372 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
827.902049 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.6775ms (max=1200ms) -
827.902049 Get Diagnostic Response Positive response was received. -
827.902049 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
827.902049 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.153.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
827.902049 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 153 -
827.902049 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.153.5. Wait: None
827.912049 1 Waited for 10.000 ms -
20.153.6. Wait 10ms: None
827.922049 1 Waited for 10.000 ms -
20.154. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 154)
20.154.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
827.922049 Diagnostic request 0x11, 0x01 -
827.923456 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.40658ms (max=1000ms) -
827.923456 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
827.932106 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.65053ms (max=1200ms) -
827.932106 Get Diagnostic Response Positive response was received. -
827.932106 Diagnostic response 0x51, 0x01 -
827.932106 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.154.2. (In for loop)Wait for the diagnostics to start: None
830.332106 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.154.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
830.332106 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
830.333533 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.42614ms (max=1000ms) -
830.333533 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
830.347252 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.7195ms (max=1200ms) -
830.347252 Get Diagnostic Response Positive response was received. -
830.347252 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
830.347252 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.154.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
830.347252 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 154 -
830.347252 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.154.5. Wait: None
830.357252 1 Waited for 10.000 ms -
20.154.6. Wait 10ms: None
830.367252 1 Waited for 10.000 ms -
20.155. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 155)
20.155.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
830.367252 Diagnostic request 0x11, 0x01 -
830.368661 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.40858ms (max=1000ms) -
830.368661 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
830.377305 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.64455ms (max=1200ms) -
830.377305 Get Diagnostic Response Positive response was received. -
830.377305 Diagnostic response 0x51, 0x01 -
830.377305 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.155.2. (In for loop)Wait for the diagnostics to start: None
832.777305 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.155.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
832.777305 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
832.778882 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.57686ms (max=1000ms) -
832.778882 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
832.792462 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.5795ms (max=1200ms) -
832.792462 Get Diagnostic Response Positive response was received. -
832.792462 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
832.792462 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.155.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
832.792462 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 155 -
832.792462 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.155.5. Wait: None
832.802462 1 Waited for 10.000 ms -
20.155.6. Wait 10ms: None
832.812462 1 Waited for 10.000 ms -
20.156. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 156)
20.156.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
832.812462 Diagnostic request 0x11, 0x01 -
832.813806 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.34467ms (max=1000ms) -
832.813806 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
832.822516 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.70956ms (max=1200ms) -
832.822516 Get Diagnostic Response Positive response was received. -
832.822516 Diagnostic response 0x51, 0x01 -
832.822516 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.156.2. (In for loop)Wait for the diagnostics to start: None
835.222516 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.156.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
835.222516 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
835.224016 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.50028ms (max=1000ms) -
835.224016 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
835.237724 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.7075ms (max=1200ms) -
835.237724 Get Diagnostic Response Positive response was received. -
835.237724 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
835.237724 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.156.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
835.237724 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 156 -
835.237724 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.156.5. Wait: None
835.247724 1 Waited for 10.000 ms -
20.156.6. Wait 10ms: None
835.257724 1 Waited for 10.000 ms -
20.157. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 157)
20.157.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
835.257724 Diagnostic request 0x11, 0x01 -
835.259134 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.41058ms (max=1000ms) -
835.259134 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
835.267775 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.64056ms (max=1200ms) -
835.267775 Get Diagnostic Response Positive response was received. -
835.267775 Diagnostic response 0x51, 0x01 -
835.267775 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.157.2. (In for loop)Wait for the diagnostics to start: None
837.667775 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.157.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
837.667775 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
837.669213 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.43788ms (max=1000ms) -
837.669213 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
837.682970 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.7575ms (max=1200ms) -
837.682970 Get Diagnostic Response Positive response was received. -
837.682970 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
837.682970 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.157.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
837.682970 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 157 -
837.682970 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.157.5. Wait: None
837.692970 1 Waited for 10.000 ms -
20.157.6. Wait 10ms: None
837.702970 1 Waited for 10.000 ms -
20.158. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 158)
20.158.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
837.702970 Diagnostic request 0x11, 0x01 -
837.704475 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.50458ms (max=1000ms) -
837.704475 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
837.713025 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.55052ms (max=1200ms) -
837.713025 Get Diagnostic Response Positive response was received. -
837.713025 Diagnostic response 0x51, 0x01 -
837.713025 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.158.2. (In for loop)Wait for the diagnostics to start: None
840.113025 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.158.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
840.113025 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
840.114442 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.41672ms (max=1000ms) -
840.114442 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
840.128097 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.6555ms (max=1200ms) -
840.128097 Get Diagnostic Response Positive response was received. -
840.128097 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
840.128097 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.158.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
840.128097 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 158 -
840.128097 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.158.5. Wait: None
840.138097 1 Waited for 10.000 ms -
20.158.6. Wait 10ms: None
840.148097 1 Waited for 10.000 ms -
20.159. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 159)
20.159.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
840.148097 Diagnostic request 0x11, 0x01 -
840.149416 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.31856ms (max=1000ms) -
840.149416 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
840.158153 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.73656ms (max=1200ms) -
840.158153 Get Diagnostic Response Positive response was received. -
840.158153 Diagnostic response 0x51, 0x01 -
840.158153 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.159.2. (In for loop)Wait for the diagnostics to start: None
842.558153 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.159.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
842.558153 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
842.559505 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.35278ms (max=1000ms) -
842.559505 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
842.573297 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.7915ms (max=1200ms) -
842.573297 Get Diagnostic Response Positive response was received. -
842.573297 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
842.573297 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.159.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
842.573297 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 159 -
842.573297 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.159.5. Wait: None
842.583297 1 Waited for 10.000 ms -
20.159.6. Wait 10ms: None
842.593297 1 Waited for 10.000 ms -
20.160. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 160)
20.160.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
842.593297 Diagnostic request 0x11, 0x01 -
842.594689 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.39258ms (max=1000ms) -
842.594689 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
842.603413 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.72355ms (max=1200ms) -
842.603413 Get Diagnostic Response Positive response was received. -
842.603413 Diagnostic response 0x51, 0x01 -
842.603413 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.160.2. (In for loop)Wait for the diagnostics to start: None
845.003413 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.160.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
845.003413 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
845.005007 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.59408ms (max=1000ms) -
845.005007 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
845.018537 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.5295ms (max=1200ms) -
845.018537 Get Diagnostic Response Positive response was received. -
845.018537 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
845.018537 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.160.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
845.018537 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 160 -
845.018537 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.160.5. Wait: None
845.028537 1 Waited for 10.000 ms -
20.160.6. Wait 10ms: None
845.038537 1 Waited for 10.000 ms -
20.161. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 161)
20.161.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
845.038537 Diagnostic request 0x11, 0x01 -
845.039853 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.31658ms (max=1000ms) -
845.039853 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
845.048587 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.73355ms (max=1200ms) -
845.048587 Get Diagnostic Response Positive response was received. -
845.048587 Diagnostic response 0x51, 0x01 -
845.048587 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.161.2. (In for loop)Wait for the diagnostics to start: None
847.448587 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.161.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
847.448587 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
847.449994 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.40777ms (max=1000ms) -
847.449994 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
847.463770 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.7755ms (max=1200ms) -
847.463770 Get Diagnostic Response Positive response was received. -
847.463770 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
847.463770 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.161.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
847.463770 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 161 -
847.463770 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.161.5. Wait: None
847.473770 1 Waited for 10.000 ms -
20.161.6. Wait 10ms: None
847.483770 1 Waited for 10.000 ms -
20.162. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 162)
20.162.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
847.483770 Diagnostic request 0x11, 0x01 -
847.485120 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.35056ms (max=1000ms) -
847.485120 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
847.493820 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.69956ms (max=1200ms) -
847.493820 Get Diagnostic Response Positive response was received. -
847.493820 Diagnostic response 0x51, 0x01 -
847.493820 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.162.2. (In for loop)Wait for the diagnostics to start: None
849.893820 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.162.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
849.893820 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
849.895328 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.50761ms (max=1000ms) -
849.895328 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
849.908993 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.6655ms (max=1200ms) -
849.908993 Get Diagnostic Response Positive response was received. -
849.908993 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
849.908993 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.162.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
849.908993 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 162 -
849.908993 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.162.5. Wait: None
849.918993 1 Waited for 10.000 ms -
20.162.6. Wait 10ms: None
849.928993 1 Waited for 10.000 ms -
20.163. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 163)
20.163.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
849.928993 Diagnostic request 0x11, 0x01 -
849.930310 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.31655ms (max=1000ms) -
849.930310 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
849.939049 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.73956ms (max=1200ms) -
849.939049 Get Diagnostic Response Positive response was received. -
849.939049 Diagnostic response 0x51, 0x01 -
849.939049 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.163.2. (In for loop)Wait for the diagnostics to start: None
852.339049 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.163.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
852.339049 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
852.340464 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.41427ms (max=1000ms) -
852.340464 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
852.354039 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.5755ms (max=1200ms) -
852.354039 Get Diagnostic Response Positive response was received. -
852.354039 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
852.354039 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.163.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
852.354039 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 163 -
852.354039 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.163.5. Wait: None
852.364039 1 Waited for 10.000 ms -
20.163.6. Wait 10ms: None
852.374039 1 Waited for 10.000 ms -
20.164. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 164)
20.164.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
852.374039 Diagnostic request 0x11, 0x01 -
852.375342 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.30258ms (max=1000ms) -
852.375342 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
852.384092 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.75058ms (max=1200ms) -
852.384092 Get Diagnostic Response Positive response was received. -
852.384092 Diagnostic response 0x51, 0x01 -
852.384092 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.164.2. (In for loop)Wait for the diagnostics to start: None
854.784092 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.164.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
854.784092 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
854.785502 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.40972ms (max=1000ms) -
854.785502 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
854.799193 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.6915ms (max=1200ms) -
854.799193 Get Diagnostic Response Positive response was received. -
854.799193 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
854.799193 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.164.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
854.799193 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 164 -
854.799193 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.164.5. Wait: None
854.809193 1 Waited for 10.000 ms -
20.164.6. Wait 10ms: None
854.819193 1 Waited for 10.000 ms -
20.165. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 165)
20.165.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
854.819193 Diagnostic request 0x11, 0x01 -
854.820412 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.21858ms (max=1000ms) -
854.820412 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
854.829245 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.83353ms (max=1200ms) -
854.829245 Get Diagnostic Response Positive response was received. -
854.829245 Diagnostic response 0x51, 0x01 -
854.829245 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.165.2. (In for loop)Wait for the diagnostics to start: None
857.229245 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.165.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
857.229245 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
857.230893 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.64767ms (max=1000ms) -
857.230893 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
857.244355 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.4615ms (max=1200ms) -
857.244355 Get Diagnostic Response Positive response was received. -
857.244355 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
857.244355 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.165.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
857.244355 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 165 -
857.244355 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.165.5. Wait: None
857.254355 1 Waited for 10.000 ms -
20.165.6. Wait 10ms: None
857.264355 1 Waited for 10.000 ms -
20.166. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 166)
20.166.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
857.264355 Diagnostic request 0x11, 0x01 -
857.265735 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.38058ms (max=1000ms) -
857.265735 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
857.274408 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.67256ms (max=1200ms) -
857.274408 Get Diagnostic Response Positive response was received. -
857.274408 Diagnostic response 0x51, 0x01 -
857.274408 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.166.2. (In for loop)Wait for the diagnostics to start: None
859.674408 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.166.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
859.674408 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
859.676182 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.77448ms (max=1000ms) -
859.676182 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
859.689560 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.3775ms (max=1200ms) -
859.689560 Get Diagnostic Response Positive response was received. -
859.689560 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
859.689560 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.166.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
859.689560 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 166 -
859.689560 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.166.5. Wait: None
859.699560 1 Waited for 10.000 ms -
20.166.6. Wait 10ms: None
859.709560 1 Waited for 10.000 ms -
20.167. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 167)
20.167.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
859.709560 Diagnostic request 0x11, 0x01 -
859.710964 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.40458ms (max=1000ms) -
859.710964 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
859.719612 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.64805ms (max=1200ms) -
859.719612 Get Diagnostic Response Positive response was received. -
859.719612 Diagnostic response 0x51, 0x01 -
859.719612 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.167.2. (In for loop)Wait for the diagnostics to start: None
862.119612 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.167.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
862.119612 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
862.121210 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.59758ms (max=1000ms) -
862.121210 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
862.134835 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.6255ms (max=1200ms) -
862.134835 Get Diagnostic Response Positive response was received. -
862.134835 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
862.134835 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.167.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
862.134835 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 167 -
862.134835 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.167.5. Wait: None
862.144835 1 Waited for 10.000 ms -
20.167.6. Wait 10ms: None
862.154835 1 Waited for 10.000 ms -
20.168. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 168)
20.168.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
862.154835 Diagnostic request 0x11, 0x01 -
862.156226 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.39058ms (max=1000ms) -
862.156226 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
862.164891 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.66456ms (max=1200ms) -
862.164891 Get Diagnostic Response Positive response was received. -
862.164891 Diagnostic response 0x51, 0x01 -
862.164891 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.168.2. (In for loop)Wait for the diagnostics to start: None
864.564891 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.168.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
864.564891 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
864.566330 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.43978ms (max=1000ms) -
864.566330 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
864.580036 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.7055ms (max=1200ms) -
864.580036 Get Diagnostic Response Positive response was received. -
864.580036 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
864.580036 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.168.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
864.580036 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 168 -
864.580036 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.168.5. Wait: None
864.590036 1 Waited for 10.000 ms -
20.168.6. Wait 10ms: None
864.600036 1 Waited for 10.000 ms -
20.169. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 169)
20.169.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
864.600036 Diagnostic request 0x11, 0x01 -
864.601559 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.52295ms (max=1000ms) -
864.601559 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
864.610089 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.53003ms (max=1200ms) -
864.610089 Get Diagnostic Response Positive response was received. -
864.610089 Diagnostic response 0x51, 0x01 -
864.610089 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.169.2. (In for loop)Wait for the diagnostics to start: None
867.010089 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.169.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
867.010089 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
867.011584 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.49513ms (max=1000ms) -
867.011584 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
867.025209 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.6255ms (max=1200ms) -
867.025209 Get Diagnostic Response Positive response was received. -
867.025209 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
867.025209 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.169.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
867.025209 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 169 -
867.025209 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.169.5. Wait: None
867.035209 1 Waited for 10.000 ms -
20.169.6. Wait 10ms: None
867.045209 1 Waited for 10.000 ms -
20.170. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 170)
20.170.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
867.045209 Diagnostic request 0x11, 0x01 -
867.046498 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.28861ms (max=1000ms) -
867.046498 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
867.055266 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.76755ms (max=1200ms) -
867.055266 Get Diagnostic Response Positive response was received. -
867.055266 Diagnostic response 0x51, 0x01 -
867.055266 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.170.2. (In for loop)Wait for the diagnostics to start: None
869.455266 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.170.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
869.455266 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
869.456932 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.66673ms (max=1000ms) -
869.456932 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
869.470348 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.4155ms (max=1200ms) -
869.470348 Get Diagnostic Response Positive response was received. -
869.470348 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
869.470348 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.170.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
869.470348 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 170 -
869.470348 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.170.5. Wait: None
869.480348 1 Waited for 10.000 ms -
20.170.6. Wait 10ms: None
869.490348 1 Waited for 10.000 ms -
20.171. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 171)
20.171.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
869.490348 Diagnostic request 0x11, 0x01 -
869.491848 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.50056ms (max=1000ms) -
869.491848 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
869.500404 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.55555ms (max=1200ms) -
869.500404 Get Diagnostic Response Positive response was received. -
869.500404 Diagnostic response 0x51, 0x01 -
869.500404 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.171.2. (In for loop)Wait for the diagnostics to start: None
871.900404 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.171.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
871.900404 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
871.902125 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.72087ms (max=1000ms) -
871.902125 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
871.915632 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.5075ms (max=1200ms) -
871.915632 Get Diagnostic Response Positive response was received. -
871.915632 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
871.915632 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.171.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
871.915632 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 171 -
871.915632 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.171.5. Wait: None
871.925632 1 Waited for 10.000 ms -
20.171.6. Wait 10ms: None
871.935632 1 Waited for 10.000 ms -
20.172. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 172)
20.172.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
871.935632 Diagnostic request 0x11, 0x01 -
871.936927 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.29458ms (max=1000ms) -
871.936927 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
871.945682 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.75556ms (max=1200ms) -
871.945682 Get Diagnostic Response Positive response was received. -
871.945682 Diagnostic response 0x51, 0x01 -
871.945682 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.172.2. (In for loop)Wait for the diagnostics to start: None
874.345682 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.172.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
874.345682 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
874.347167 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.48452ms (max=1000ms) -
874.347167 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
874.360888 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.7215ms (max=1200ms) -
874.360888 Get Diagnostic Response Positive response was received. -
874.360888 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
874.360888 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.172.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
874.360888 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 172 -
874.360888 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.172.5. Wait: None
874.370888 1 Waited for 10.000 ms -
20.172.6. Wait 10ms: None
874.380888 1 Waited for 10.000 ms -
20.173. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 173)
20.173.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
874.380888 Diagnostic request 0x11, 0x01 -
874.382251 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.36256ms (max=1000ms) -
874.382251 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
874.390945 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.69353ms (max=1200ms) -
874.390945 Get Diagnostic Response Positive response was received. -
874.390945 Diagnostic response 0x51, 0x01 -
874.390945 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.173.2. (In for loop)Wait for the diagnostics to start: None
876.790945 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.173.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
876.790945 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
876.792402 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.45789ms (max=1000ms) -
876.792402 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
876.806112 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.7099ms (max=1200ms) -
876.806112 Get Diagnostic Response Positive response was received. -
876.806112 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
876.806112 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.173.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
876.806112 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 173 -
876.806112 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.173.5. Wait: None
876.816112 1 Waited for 10.000 ms -
20.173.6. Wait 10ms: None
876.826112 1 Waited for 10.000 ms -
20.174. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 174)
20.174.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
876.826112 Diagnostic request 0x11, 0x01 -
876.827495 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.38258ms (max=1000ms) -
876.827495 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
876.836073 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.57853ms (max=1200ms) -
876.836073 Get Diagnostic Response Positive response was received. -
876.836073 Diagnostic response 0x51, 0x01 -
876.836073 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.174.2. (In for loop)Wait for the diagnostics to start: None
879.236073 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.174.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
879.236073 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
879.237494 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.42014ms (max=1000ms) -
879.237494 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
879.251207 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.7135ms (max=1200ms) -
879.251207 Get Diagnostic Response Positive response was received. -
879.251207 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
879.251207 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.174.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
879.251207 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 174 -
879.251207 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.174.5. Wait: None
879.261207 1 Waited for 10.000 ms -
20.174.6. Wait 10ms: None
879.271207 1 Waited for 10.000 ms -
20.175. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 175)
20.175.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
879.271207 Diagnostic request 0x11, 0x01 -
879.272462 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.25458ms (max=1000ms) -
879.272462 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
879.281264 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.80253ms (max=1200ms) -
879.281264 Get Diagnostic Response Positive response was received. -
879.281264 Diagnostic response 0x51, 0x01 -
879.281264 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.175.2. (In for loop)Wait for the diagnostics to start: None
881.681264 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.175.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
881.681264 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
881.682919 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.65433ms (max=1000ms) -
881.682919 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
881.696440 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.5215ms (max=1200ms) -
881.696440 Get Diagnostic Response Positive response was received. -
881.696440 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
881.696440 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.175.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
881.696440 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 175 -
881.696440 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.175.5. Wait: None
881.706440 1 Waited for 10.000 ms -
20.175.6. Wait 10ms: None
881.716440 1 Waited for 10.000 ms -
20.176. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 176)
20.176.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
881.716440 Diagnostic request 0x11, 0x01 -
881.717777 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.33659ms (max=1000ms) -
881.717777 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
881.726494 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.71755ms (max=1200ms) -
881.726494 Get Diagnostic Response Positive response was received. -
881.726494 Diagnostic response 0x51, 0x01 -
881.726494 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.176.2. (In for loop)Wait for the diagnostics to start: None
884.126494 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.176.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
884.126494 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
884.127995 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.50041ms (max=1000ms) -
884.127995 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
884.141590 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.5955ms (max=1200ms) -
884.141590 Get Diagnostic Response Positive response was received. -
884.141590 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
884.141590 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.176.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
884.141590 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 176 -
884.141590 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.176.5. Wait: None
884.151590 1 Waited for 10.000 ms -
20.176.6. Wait 10ms: None
884.161590 1 Waited for 10.000 ms -
20.177. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 177)
20.177.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
884.161590 Diagnostic request 0x11, 0x01 -
884.162955 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.36458ms (max=1000ms) -
884.162955 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
884.171645 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.69056ms (max=1200ms) -
884.171645 Get Diagnostic Response Positive response was received. -
884.171645 Diagnostic response 0x51, 0x01 -
884.171645 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.177.2. (In for loop)Wait for the diagnostics to start: None
886.571645 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.177.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
886.571645 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
886.573150 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.50452ms (max=1000ms) -
886.573150 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
886.586853 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.7035ms (max=1200ms) -
886.586853 Get Diagnostic Response Positive response was received. -
886.586853 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
886.586853 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.177.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
886.586853 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 177 -
886.586853 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.177.5. Wait: None
886.596853 1 Waited for 10.000 ms -
20.177.6. Wait 10ms: None
886.606853 1 Waited for 10.000 ms -
20.178. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 178)
20.178.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
886.606853 Diagnostic request 0x11, 0x01 -
886.608162 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.30873ms (max=1000ms) -
886.608162 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
886.616908 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.74656ms (max=1200ms) -
886.616908 Get Diagnostic Response Positive response was received. -
886.616908 Diagnostic response 0x51, 0x01 -
886.616908 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.178.2. (In for loop)Wait for the diagnostics to start: None
889.016908 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.178.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
889.016908 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
889.018274 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.36505ms (max=1000ms) -
889.018274 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
889.032077 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.8035ms (max=1200ms) -
889.032077 Get Diagnostic Response Positive response was received. -
889.032077 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
889.032077 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.178.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
889.032077 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 178 -
889.032077 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.178.5. Wait: None
889.042077 1 Waited for 10.000 ms -
20.178.6. Wait 10ms: None
889.052077 1 Waited for 10.000 ms -
20.179. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 179)
20.179.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
889.052077 Diagnostic request 0x11, 0x01 -
889.053372 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.29458ms (max=1000ms) -
889.053372 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
889.062128 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.75653ms (max=1200ms) -
889.062128 Get Diagnostic Response Positive response was received. -
889.062128 Diagnostic response 0x51, 0x01 -
889.062128 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.179.2. (In for loop)Wait for the diagnostics to start: None
891.462128 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.179.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
891.462128 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
891.463516 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.38772ms (max=1000ms) -
891.463516 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
891.477271 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.7555ms (max=1200ms) -
891.477271 Get Diagnostic Response Positive response was received. -
891.477271 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
891.477271 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.179.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
891.477271 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 179 -
891.477271 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.179.5. Wait: None
891.487271 1 Waited for 10.000 ms -
20.179.6. Wait 10ms: None
891.497271 1 Waited for 10.000 ms -
20.180. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 180)
20.180.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
891.497271 Diagnostic request 0x11, 0x01 -
891.498672 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.40056ms (max=1000ms) -
891.498672 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
891.507326 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.65452ms (max=1200ms) -
891.507326 Get Diagnostic Response Positive response was received. -
891.507326 Diagnostic response 0x51, 0x01 -
891.507326 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.180.2. (In for loop)Wait for the diagnostics to start: None
893.907326 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.180.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
893.907326 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
893.908940 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.6133ms (max=1000ms) -
893.908940 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
893.922333 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.3935ms (max=1200ms) -
893.922333 Get Diagnostic Response Positive response was received. -
893.922333 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
893.922333 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.180.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
893.922333 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 180 -
893.922333 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.180.5. Wait: None
893.932333 1 Waited for 10.000 ms -
20.180.6. Wait 10ms: None
893.942333 1 Waited for 10.000 ms -
20.181. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 181)
20.181.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
893.942333 Diagnostic request 0x11, 0x01 -
893.943710 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.37655ms (max=1000ms) -
893.943710 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
893.952383 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.67356ms (max=1200ms) -
893.952383 Get Diagnostic Response Positive response was received. -
893.952383 Diagnostic response 0x51, 0x01 -
893.952383 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.181.2. (In for loop)Wait for the diagnostics to start: None
896.352383 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.181.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
896.352383 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
896.353958 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.57438ms (max=1000ms) -
896.353958 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
896.367471 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.5135ms (max=1200ms) -
896.367471 Get Diagnostic Response Positive response was received. -
896.367471 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
896.367471 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.181.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
896.367471 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 181 -
896.367471 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.181.5. Wait: None
896.377471 1 Waited for 10.000 ms -
20.181.6. Wait 10ms: None
896.387471 1 Waited for 10.000 ms -
20.182. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 182)
20.182.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
896.387471 Diagnostic request 0x11, 0x01 -
896.388836 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.36458ms (max=1000ms) -
896.388836 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
896.397519 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.68355ms (max=1200ms) -
896.397519 Get Diagnostic Response Positive response was received. -
896.397519 Diagnostic response 0x51, 0x01 -
896.397519 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.182.2. (In for loop)Wait for the diagnostics to start: None
898.797519 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.182.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
898.797519 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
898.799006 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.48628ms (max=1000ms) -
898.799006 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
898.812503 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.4979ms (max=1200ms) -
898.812503 Get Diagnostic Response Positive response was received. -
898.812503 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
898.812503 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.182.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
898.812503 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 182 -
898.812503 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.182.5. Wait: None
898.822503 1 Waited for 10.000 ms -
20.182.6. Wait 10ms: None
898.832503 1 Waited for 10.000 ms -
20.183. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 183)
20.183.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
898.832503 Diagnostic request 0x11, 0x01 -
898.833790 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.28659ms (max=1000ms) -
898.833790 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
898.842557 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.76653ms (max=1200ms) -
898.842557 Get Diagnostic Response Positive response was received. -
898.842557 Diagnostic response 0x51, 0x01 -
898.842557 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.183.2. (In for loop)Wait for the diagnostics to start: None
901.242557 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.183.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
901.242557 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
901.243995 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.43867ms (max=1000ms) -
901.243995 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
901.257651 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.6555ms (max=1200ms) -
901.257651 Get Diagnostic Response Positive response was received. -
901.257651 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
901.257651 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.183.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
901.257651 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 183 -
901.257651 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.183.5. Wait: None
901.267651 1 Waited for 10.000 ms -
20.183.6. Wait 10ms: None
901.277651 1 Waited for 10.000 ms -
20.184. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 184)
20.184.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
901.277651 Diagnostic request 0x11, 0x01 -
901.279015 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.36458ms (max=1000ms) -
901.279015 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
901.287703 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.68759ms (max=1200ms) -
901.287703 Get Diagnostic Response Positive response was received. -
901.287703 Diagnostic response 0x51, 0x01 -
901.287703 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.184.2. (In for loop)Wait for the diagnostics to start: None
903.687703 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.184.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
903.687703 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
903.689141 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.43826ms (max=1000ms) -
903.689141 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
903.702841 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.6995ms (max=1200ms) -
903.702841 Get Diagnostic Response Positive response was received. -
903.702841 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
903.702841 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.184.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
903.702841 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 184 -
903.702841 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.184.5. Wait: None
903.712841 1 Waited for 10.000 ms -
20.184.6. Wait 10ms: None
903.722841 1 Waited for 10.000 ms -
20.185. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 185)
20.185.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
903.722841 Diagnostic request 0x11, 0x01 -
903.724187 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.34658ms (max=1000ms) -
903.724187 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
903.732897 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.70955ms (max=1200ms) -
903.732897 Get Diagnostic Response Positive response was received. -
903.732897 Diagnostic response 0x51, 0x01 -
903.732897 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.185.2. (In for loop)Wait for the diagnostics to start: None
906.132897 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.185.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
906.132897 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
906.134309 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.41206ms (max=1000ms) -
906.134309 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
906.147966 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.6575ms (max=1200ms) -
906.147966 Get Diagnostic Response Positive response was received. -
906.147966 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
906.147966 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.185.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
906.147966 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 185 -
906.147966 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.185.5. Wait: None
906.157966 1 Waited for 10.000 ms -
20.185.6. Wait 10ms: None
906.167966 1 Waited for 10.000 ms -
20.186. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 186)
20.186.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
906.167966 Diagnostic request 0x11, 0x01 -
906.169261 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.29456ms (max=1000ms) -
906.169261 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
906.178019 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.75853ms (max=1200ms) -
906.178019 Get Diagnostic Response Positive response was received. -
906.178019 Diagnostic response 0x51, 0x01 -
906.178019 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.186.2. (In for loop)Wait for the diagnostics to start: None
908.578019 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.186.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
908.578019 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
908.579480 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.46028ms (max=1000ms) -
908.579480 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
908.593091 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.6115ms (max=1200ms) -
908.593091 Get Diagnostic Response Positive response was received. -
908.593091 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
908.593091 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.186.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
908.593091 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 186 -
908.593091 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.186.5. Wait: None
908.603091 1 Waited for 10.000 ms -
20.186.6. Wait 10ms: None
908.613091 1 Waited for 10.000 ms -
20.187. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 187)
20.187.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
908.613091 Diagnostic request 0x11, 0x01 -
908.614346 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.25466ms (max=1000ms) -
908.614346 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
908.623147 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.80153ms (max=1200ms) -
908.623147 Get Diagnostic Response Positive response was received. -
908.623147 Diagnostic response 0x51, 0x01 -
908.623147 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.187.2. (In for loop)Wait for the diagnostics to start: None
911.023147 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.187.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
911.023147 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
911.024479 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.33169ms (max=1000ms) -
911.024479 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
911.038239 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.7595ms (max=1200ms) -
911.038239 Get Diagnostic Response Positive response was received. -
911.038239 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
911.038239 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.187.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
911.038239 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 187 -
911.038239 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.187.5. Wait: None
911.048239 1 Waited for 10.000 ms -
20.187.6. Wait 10ms: None
911.058239 1 Waited for 10.000 ms -
20.188. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 188)
20.188.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
911.058239 Diagnostic request 0x11, 0x01 -
911.059465 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.22658ms (max=1000ms) -
911.059465 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
911.068291 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.82553ms (max=1200ms) -
911.068291 Get Diagnostic Response Positive response was received. -
911.068291 Diagnostic response 0x51, 0x01 -
911.068291 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.188.2. (In for loop)Wait for the diagnostics to start: None
913.468291 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.188.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
913.468291 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
913.469940 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.64914ms (max=1000ms) -
913.469940 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
913.483411 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.4715ms (max=1200ms) -
913.483411 Get Diagnostic Response Positive response was received. -
913.483411 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
913.483411 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.188.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
913.483411 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 188 -
913.483411 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.188.5. Wait: None
913.493411 1 Waited for 10.000 ms -
20.188.6. Wait 10ms: None
913.503411 1 Waited for 10.000 ms -
20.189. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 189)
20.189.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
913.503411 Diagnostic request 0x11, 0x01 -
913.504804 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.39258ms (max=1000ms) -
913.504804 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
913.513465 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.66155ms (max=1200ms) -
913.513465 Get Diagnostic Response Positive response was received. -
913.513465 Diagnostic response 0x51, 0x01 -
913.513465 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.189.2. (In for loop)Wait for the diagnostics to start: None
915.913465 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.189.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
915.913465 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
915.914990 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.52453ms (max=1000ms) -
915.914990 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
915.928514 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.5235ms (max=1200ms) -
915.928514 Get Diagnostic Response Positive response was received. -
915.928514 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
915.928514 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.189.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
915.928514 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 189 -
915.928514 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.189.5. Wait: None
915.938514 1 Waited for 10.000 ms -
20.189.6. Wait 10ms: None
915.948514 1 Waited for 10.000 ms -
20.190. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 190)
20.190.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
915.948514 Diagnostic request 0x11, 0x01 -
915.949926 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.41256ms (max=1000ms) -
915.949926 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
915.958559 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.63259ms (max=1200ms) -
915.958559 Get Diagnostic Response Positive response was received. -
915.958559 Diagnostic response 0x51, 0x01 -
915.958559 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.190.2. (In for loop)Wait for the diagnostics to start: None
918.358559 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.190.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
918.358559 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
918.360036 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.47701ms (max=1000ms) -
918.360036 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
918.373699 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.6635ms (max=1200ms) -
918.373699 Get Diagnostic Response Positive response was received. -
918.373699 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
918.373699 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.190.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
918.373699 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 190 -
918.373699 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.190.5. Wait: None
918.383699 1 Waited for 10.000 ms -
20.190.6. Wait 10ms: None
918.393699 1 Waited for 10.000 ms -
20.191. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 191)
20.191.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
918.393699 Diagnostic request 0x11, 0x01 -
918.395020 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.32055ms (max=1000ms) -
918.395020 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
918.403816 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.79658ms (max=1200ms) -
918.403816 Get Diagnostic Response Positive response was received. -
918.403816 Diagnostic response 0x51, 0x01 -
918.403816 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.191.2. (In for loop)Wait for the diagnostics to start: None
920.803816 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.191.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
920.803816 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
920.805334 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.5178ms (max=1000ms) -
920.805334 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
920.818906 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.5715ms (max=1200ms) -
920.818906 Get Diagnostic Response Positive response was received. -
920.818906 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
920.818906 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.191.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
920.818906 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 191 -
920.818906 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.191.5. Wait: None
920.828906 1 Waited for 10.000 ms -
20.191.6. Wait 10ms: None
920.838906 1 Waited for 10.000 ms -
20.192. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 192)
20.192.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
920.838906 Diagnostic request 0x11, 0x01 -
920.840222 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.31659ms (max=1000ms) -
920.840222 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
920.848958 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.73555ms (max=1200ms) -
920.848958 Get Diagnostic Response Positive response was received. -
920.848958 Diagnostic response 0x51, 0x01 -
920.848958 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.192.2. (In for loop)Wait for the diagnostics to start: None
923.248958 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.192.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
923.248958 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
923.250444 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.48672ms (max=1000ms) -
923.250444 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
923.264094 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.6495ms (max=1200ms) -
923.264094 Get Diagnostic Response Positive response was received. -
923.264094 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
923.264094 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.192.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
923.264094 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 192 -
923.264094 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.192.5. Wait: None
923.274094 1 Waited for 10.000 ms -
20.192.6. Wait 10ms: None
923.284094 1 Waited for 10.000 ms -
20.193. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 193)
20.193.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
923.284094 Diagnostic request 0x11, 0x01 -
923.285341 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.24658ms (max=1000ms) -
923.285341 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
923.294147 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.80658ms (max=1200ms) -
923.294147 Get Diagnostic Response Positive response was received. -
923.294147 Diagnostic response 0x51, 0x01 -
923.294147 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.193.2. (In for loop)Wait for the diagnostics to start: None
925.694147 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.193.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
925.694147 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
925.695539 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.39209ms (max=1000ms) -
925.695539 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
925.709247 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.7075ms (max=1200ms) -
925.709247 Get Diagnostic Response Positive response was received. -
925.709247 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
925.709247 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.193.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
925.709247 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 193 -
925.709247 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.193.5. Wait: None
925.719247 1 Waited for 10.000 ms -
20.193.6. Wait 10ms: None
925.729247 1 Waited for 10.000 ms -
20.194. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 194)
20.194.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
925.729247 Diagnostic request 0x11, 0x01 -
925.730893 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.64655ms (max=1000ms) -
925.730893 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
925.739300 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.40655ms (max=1200ms) -
925.739300 Get Diagnostic Response Positive response was received. -
925.739300 Diagnostic response 0x51, 0x01 -
925.739300 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.194.2. (In for loop)Wait for the diagnostics to start: None
928.139300 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.194.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
928.139300 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
928.140929 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.62898ms (max=1000ms) -
928.140929 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
928.154368 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.4395ms (max=1200ms) -
928.154368 Get Diagnostic Response Positive response was received. -
928.154368 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
928.154368 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.194.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
928.154368 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 194 -
928.154368 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.194.5. Wait: None
928.164368 1 Waited for 10.000 ms -
20.194.6. Wait 10ms: None
928.174368 1 Waited for 10.000 ms -
20.195. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 195)
20.195.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
928.174368 Diagnostic request 0x11, 0x01 -
928.175897 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.52858ms (max=1000ms) -
928.175897 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
928.184421 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.52453ms (max=1200ms) -
928.184421 Get Diagnostic Response Positive response was received. -
928.184421 Diagnostic response 0x51, 0x01 -
928.184421 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.195.2. (In for loop)Wait for the diagnostics to start: None
930.584421 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.195.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
930.584421 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
930.585948 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.52619ms (max=1000ms) -
930.585948 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
930.599543 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.5955ms (max=1200ms) -
930.599543 Get Diagnostic Response Positive response was received. -
930.599543 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
930.599543 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.195.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
930.599543 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 195 -
930.599543 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.195.5. Wait: None
930.609543 1 Waited for 10.000 ms -
20.195.6. Wait 10ms: None
930.619543 1 Waited for 10.000 ms -
20.196. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 196)
20.196.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
930.619543 Diagnostic request 0x11, 0x01 -
930.620948 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.40463ms (max=1000ms) -
930.620948 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
930.629600 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.65253ms (max=1200ms) -
930.629600 Get Diagnostic Response Positive response was received. -
930.629600 Diagnostic response 0x51, 0x01 -
930.629600 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.196.2. (In for loop)Wait for the diagnostics to start: None
933.029600 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.196.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
933.029600 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
933.031343 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.74316ms (max=1000ms) -
933.031343 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
933.044713 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.3695ms (max=1200ms) -
933.044713 Get Diagnostic Response Positive response was received. -
933.044713 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
933.044713 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.196.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
933.044713 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 196 -
933.044713 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.196.5. Wait: None
933.054713 1 Waited for 10.000 ms -
20.196.6. Wait 10ms: None
933.064713 1 Waited for 10.000 ms -
20.197. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 197)
20.197.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
933.064713 Diagnostic request 0x11, 0x01 -
933.066131 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.41858ms (max=1000ms) -
933.066131 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
933.074767 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.63555ms (max=1200ms) -
933.074767 Get Diagnostic Response Positive response was received. -
933.074767 Diagnostic response 0x51, 0x01 -
933.074767 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.197.2. (In for loop)Wait for the diagnostics to start: None
935.474767 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.197.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
935.474767 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
935.476373 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.606ms (max=1000ms) -
935.476373 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
935.489844 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.4715ms (max=1200ms) -
935.489844 Get Diagnostic Response Positive response was received. -
935.489844 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
935.489844 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.197.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
935.489844 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 197 -
935.489844 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.197.5. Wait: None
935.499844 1 Waited for 10.000 ms -
20.197.6. Wait 10ms: None
935.509844 1 Waited for 10.000 ms -
20.198. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 198)
20.198.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
935.509844 Diagnostic request 0x11, 0x01 -
935.511217 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.37258ms (max=1000ms) -
935.511217 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
935.519900 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.68256ms (max=1200ms) -
935.519900 Get Diagnostic Response Positive response was received. -
935.519900 Diagnostic response 0x51, 0x01 -
935.519900 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.198.2. (In for loop)Wait for the diagnostics to start: None
937.919900 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.198.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
937.919900 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
937.921465 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.56517ms (max=1000ms) -
937.921465 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
937.935020 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.5555ms (max=1200ms) -
937.935020 Get Diagnostic Response Positive response was received. -
937.935020 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
937.935020 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.198.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
937.935020 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 198 -
937.935020 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.198.5. Wait: None
937.945020 1 Waited for 10.000 ms -
20.198.6. Wait 10ms: None
937.955020 1 Waited for 10.000 ms -
20.199. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 199)
20.199.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
937.955020 Diagnostic request 0x11, 0x01 -
937.956405 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.38458ms (max=1000ms) -
937.956405 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
937.965075 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.67056ms (max=1200ms) -
937.965075 Get Diagnostic Response Positive response was received. -
937.965075 Diagnostic response 0x51, 0x01 -
937.965075 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.199.2. (In for loop)Wait for the diagnostics to start: None
940.365075 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.199.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
940.365075 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
940.366566 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.49033ms (max=1000ms) -
940.366566 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
940.380225 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.6595ms (max=1200ms) -
940.380225 Get Diagnostic Response Positive response was received. -
940.380225 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
940.380225 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.199.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
940.380225 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 199 -
940.380225 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.199.5. Wait: None
940.390225 1 Waited for 10.000 ms -
20.199.6. Wait 10ms: None
940.400225 1 Waited for 10.000 ms -
20.200. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 200)
20.200.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
940.400225 Diagnostic request 0x11, 0x01 -
940.401568 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.34297ms (max=1000ms) -
940.401568 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
940.410286 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.71756ms (max=1200ms) -
940.410286 Get Diagnostic Response Positive response was received. -
940.410286 Diagnostic response 0x51, 0x01 -
940.410286 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.200.2. (In for loop)Wait for the diagnostics to start: None
942.810286 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.200.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
942.810286 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
942.811900 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.61387ms (max=1000ms) -
942.811900 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
942.825451 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.5515ms (max=1200ms) -
942.825451 Get Diagnostic Response Positive response was received. -
942.825451 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
942.825451 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.200.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
942.825451 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 200 -
942.825451 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.200.5. Wait: None
942.835451 1 Waited for 10.000 ms -
20.200.6. Wait 10ms: None
942.845451 1 Waited for 10.000 ms -
20.201. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 201)
20.201.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
942.845451 Diagnostic request 0x11, 0x01 -
942.846784 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.33258ms (max=1000ms) -
942.846784 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
942.855503 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.71956ms (max=1200ms) -
942.855503 Get Diagnostic Response Positive response was received. -
942.855503 Diagnostic response 0x51, 0x01 -
942.855503 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.201.2. (In for loop)Wait for the diagnostics to start: None
945.255503 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.201.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
945.255503 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
945.256947 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.44355ms (max=1000ms) -
945.256947 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
945.270520 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.5735ms (max=1200ms) -
945.270520 Get Diagnostic Response Positive response was received. -
945.270520 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
945.270520 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.201.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
945.270520 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 201 -
945.270520 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.201.5. Wait: None
945.280520 1 Waited for 10.000 ms -
20.201.6. Wait 10ms: None
945.290520 1 Waited for 10.000 ms -
20.202. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 202)
20.202.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
945.290520 Diagnostic request 0x11, 0x01 -
945.291879 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.35858ms (max=1000ms) -
945.291879 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
945.300573 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.69353ms (max=1200ms) -
945.300573 Get Diagnostic Response Positive response was received. -
945.300573 Diagnostic response 0x51, 0x01 -
945.300573 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.202.2. (In for loop)Wait for the diagnostics to start: None
947.700573 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.202.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
947.700573 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
947.702060 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.48797ms (max=1000ms) -
947.702060 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
947.715654 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.5935ms (max=1200ms) -
947.715654 Get Diagnostic Response Positive response was received. -
947.715654 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
947.715654 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.202.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
947.715654 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 202 -
947.715654 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.202.5. Wait: None
947.725654 1 Waited for 10.000 ms -
20.202.6. Wait 10ms: None
947.735654 1 Waited for 10.000 ms -
20.203. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 203)
20.203.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
947.735654 Diagnostic request 0x11, 0x01 -
947.736963 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.30856ms (max=1000ms) -
947.736963 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
947.745711 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.74855ms (max=1200ms) -
947.745711 Get Diagnostic Response Positive response was received. -
947.745711 Diagnostic response 0x51, 0x01 -
947.745711 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.203.2. (In for loop)Wait for the diagnostics to start: None
950.145711 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.203.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
950.145711 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
950.147228 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.51648ms (max=1000ms) -
950.147228 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
950.160821 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.5935ms (max=1200ms) -
950.160821 Get Diagnostic Response Positive response was received. -
950.160821 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
950.160821 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.203.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
950.160821 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 203 -
950.160821 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.203.5. Wait: None
950.170821 1 Waited for 10.000 ms -
20.203.6. Wait 10ms: None
950.180821 1 Waited for 10.000 ms -
20.204. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 204)
20.204.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
950.180821 Diagnostic request 0x11, 0x01 -
950.182168 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.34659ms (max=1000ms) -
950.182168 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
950.190875 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.70755ms (max=1200ms) -
950.190875 Get Diagnostic Response Positive response was received. -
950.190875 Diagnostic response 0x51, 0x01 -
950.190875 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.204.2. (In for loop)Wait for the diagnostics to start: None
952.590875 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.204.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
952.590875 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
952.592316 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.44077ms (max=1000ms) -
952.592316 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
952.605972 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.656ms (max=1200ms) -
952.605972 Get Diagnostic Response Positive response was received. -
952.605972 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
952.605972 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.204.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
952.605972 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 204 -
952.605972 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.204.5. Wait: None
952.615972 1 Waited for 10.000 ms -
20.204.6. Wait 10ms: None
952.625972 1 Waited for 10.000 ms -
20.205. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 205)
20.205.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
952.625972 Diagnostic request 0x11, 0x01 -
952.627336 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.36458ms (max=1000ms) -
952.627336 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
952.635931 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.59456ms (max=1200ms) -
952.635931 Get Diagnostic Response Positive response was received. -
952.635931 Diagnostic response 0x51, 0x01 -
952.635931 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.205.2. (In for loop)Wait for the diagnostics to start: None
955.035931 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.205.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
955.035931 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
955.037350 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.4185ms (max=1000ms) -
955.037350 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
955.050913 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.5635ms (max=1200ms) -
955.050913 Get Diagnostic Response Positive response was received. -
955.050913 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
955.050913 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.205.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
955.050913 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 205 -
955.050913 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.205.5. Wait: None
955.060913 1 Waited for 10.000 ms -
20.205.6. Wait 10ms: None
955.070913 1 Waited for 10.000 ms -
20.206. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 206)
20.206.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
955.070913 Diagnostic request 0x11, 0x01 -
955.072312 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.39856ms (max=1000ms) -
955.072312 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
955.080967 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.65553ms (max=1200ms) -
955.080967 Get Diagnostic Response Positive response was received. -
955.080967 Diagnostic response 0x51, 0x01 -
955.080967 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.206.2. (In for loop)Wait for the diagnostics to start: None
957.480967 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.206.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
957.480967 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
957.482485 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.51824ms (max=1000ms) -
957.482485 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
957.496015 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.5295ms (max=1200ms) -
957.496015 Get Diagnostic Response Positive response was received. -
957.496015 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
957.496015 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.206.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
957.496015 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 206 -
957.496015 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.206.5. Wait: None
957.506015 1 Waited for 10.000 ms -
20.206.6. Wait 10ms: None
957.516015 1 Waited for 10.000 ms -
20.207. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 207)
20.207.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
957.516015 Diagnostic request 0x11, 0x01 -
957.517381 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.36655ms (max=1000ms) -
957.517381 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
957.526068 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.68656ms (max=1200ms) -
957.526068 Get Diagnostic Response Positive response was received. -
957.526068 Diagnostic response 0x51, 0x01 -
957.526068 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.207.2. (In for loop)Wait for the diagnostics to start: None
959.926068 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.207.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
959.926068 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
959.927500 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.43172ms (max=1000ms) -
959.927500 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
959.941111 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.6115ms (max=1200ms) -
959.941111 Get Diagnostic Response Positive response was received. -
959.941111 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
959.941111 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.207.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
959.941111 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 207 -
959.941111 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.207.5. Wait: None
959.951111 1 Waited for 10.000 ms -
20.207.6. Wait 10ms: None
959.961111 1 Waited for 10.000 ms -
20.208. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 208)
20.208.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
959.961111 Diagnostic request 0x11, 0x01 -
959.962374 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.26258ms (max=1000ms) -
959.962374 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
959.971167 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.79353ms (max=1200ms) -
959.971167 Get Diagnostic Response Positive response was received. -
959.971167 Diagnostic response 0x51, 0x01 -
959.971167 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.208.2. (In for loop)Wait for the diagnostics to start: None
962.371167 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.208.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
962.371167 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
962.372561 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.39327ms (max=1000ms) -
962.372561 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
962.386340 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.7795ms (max=1200ms) -
962.386340 Get Diagnostic Response Positive response was received. -
962.386340 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
962.386340 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.208.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
962.386340 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 208 -
962.386340 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.208.5. Wait: None
962.396340 1 Waited for 10.000 ms -
20.208.6. Wait 10ms: None
962.406340 1 Waited for 10.000 ms -
20.209. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 209)
20.209.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
962.406340 Diagnostic request 0x11, 0x01 -
962.407873 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.53276ms (max=1000ms) -
962.407873 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
962.416397 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.52455ms (max=1200ms) -
962.416397 Get Diagnostic Response Positive response was received. -
962.416397 Diagnostic response 0x51, 0x01 -
962.416397 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.209.2. (In for loop)Wait for the diagnostics to start: None
964.816397 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.209.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
964.816397 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
964.817988 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.59102ms (max=1000ms) -
964.817988 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
964.831552 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.5635ms (max=1200ms) -
964.831552 Get Diagnostic Response Positive response was received. -
964.831552 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
964.831552 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.209.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
964.831552 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 209 -
964.831552 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.209.5. Wait: None
964.841552 1 Waited for 10.000 ms -
20.209.6. Wait 10ms: None
964.851552 1 Waited for 10.000 ms -
20.210. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 210)
20.210.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
964.851552 Diagnostic request 0x11, 0x01 -
964.852934 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.38256ms (max=1000ms) -
964.852934 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
964.861600 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.66556ms (max=1200ms) -
964.861600 Get Diagnostic Response Positive response was received. -
964.861600 Diagnostic response 0x51, 0x01 -
964.861600 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.210.2. (In for loop)Wait for the diagnostics to start: None
967.261600 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.210.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
967.261600 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
967.263082 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.4818ms (max=1000ms) -
967.263082 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
967.276793 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.7115ms (max=1200ms) -
967.276793 Get Diagnostic Response Positive response was received. -
967.276793 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
967.276793 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.210.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
967.276793 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 210 -
967.276793 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.210.5. Wait: None
967.286793 1 Waited for 10.000 ms -
20.210.6. Wait 10ms: None
967.296793 1 Waited for 10.000 ms -
20.211. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 211)
20.211.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
967.296793 Diagnostic request 0x11, 0x01 -
967.298236 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.44258ms (max=1000ms) -
967.298236 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
967.306846 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.61053ms (max=1200ms) -
967.306846 Get Diagnostic Response Positive response was received. -
967.306846 Diagnostic response 0x51, 0x01 -
967.306846 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.211.2. (In for loop)Wait for the diagnostics to start: None
969.706846 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.211.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
969.706846 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
969.708234 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.38745ms (max=1000ms) -
969.708234 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
969.721965 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.7315ms (max=1200ms) -
969.721965 Get Diagnostic Response Positive response was received. -
969.721965 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
969.721965 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.211.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
969.721965 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 211 -
969.721965 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.211.5. Wait: None
969.731965 1 Waited for 10.000 ms -
20.211.6. Wait 10ms: None
969.741965 1 Waited for 10.000 ms -
20.212. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 212)
20.212.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
969.741965 Diagnostic request 0x11, 0x01 -
969.743324 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.35859ms (max=1000ms) -
969.743324 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
969.752017 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.69352ms (max=1200ms) -
969.752017 Get Diagnostic Response Positive response was received. -
969.752017 Diagnostic response 0x51, 0x01 -
969.752017 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.212.2. (In for loop)Wait for the diagnostics to start: None
972.152017 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.212.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
972.152017 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
972.153507 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.48967ms (max=1000ms) -
972.153507 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
972.167165 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.6575ms (max=1200ms) -
972.167165 Get Diagnostic Response Positive response was received. -
972.167165 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
972.167165 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.212.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
972.167165 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 212 -
972.167165 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.212.5. Wait: None
972.177165 1 Waited for 10.000 ms -
20.212.6. Wait 10ms: None
972.187165 1 Waited for 10.000 ms -
20.213. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 213)
20.213.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
972.187165 Diagnostic request 0x11, 0x01 -
972.188411 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.24658ms (max=1000ms) -
972.188411 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
972.197215 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.80353ms (max=1200ms) -
972.197215 Get Diagnostic Response Positive response was received. -
972.197215 Diagnostic response 0x51, 0x01 -
972.197215 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.213.2. (In for loop)Wait for the diagnostics to start: None
974.597215 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.213.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
974.597215 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
974.598644 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.42925ms (max=1000ms) -
974.598644 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
974.612372 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.7279ms (max=1200ms) -
974.612372 Get Diagnostic Response Positive response was received. -
974.612372 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
974.612372 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.213.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
974.612372 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 213 -
974.612372 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.213.5. Wait: None
974.622372 1 Waited for 10.000 ms -
20.213.6. Wait 10ms: None
974.632372 1 Waited for 10.000 ms -
20.214. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 214)
20.214.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
974.632372 Diagnostic request 0x11, 0x01 -
974.633734 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.36258ms (max=1000ms) -
974.633734 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
974.642425 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.69058ms (max=1200ms) -
974.642425 Get Diagnostic Response Positive response was received. -
974.642425 Diagnostic response 0x51, 0x01 -
974.642425 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.214.2. (In for loop)Wait for the diagnostics to start: None
977.042425 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.214.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
977.042425 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
977.043941 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.51559ms (max=1000ms) -
977.043941 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
977.057514 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.5735ms (max=1200ms) -
977.057514 Get Diagnostic Response Positive response was received. -
977.057514 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
977.057514 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.214.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
977.057514 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 214 -
977.057514 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.214.5. Wait: None
977.067514 1 Waited for 10.000 ms -
20.214.6. Wait 10ms: None
977.077514 1 Waited for 10.000 ms -
20.215. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 215)
20.215.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
977.077514 Diagnostic request 0x11, 0x01 -
977.078895 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.38058ms (max=1000ms) -
977.078895 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
977.087568 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.67353ms (max=1200ms) -
977.087568 Get Diagnostic Response Positive response was received. -
977.087568 Diagnostic response 0x51, 0x01 -
977.087568 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.215.2. (In for loop)Wait for the diagnostics to start: None
979.487568 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.215.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
979.487568 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
979.489054 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.48542ms (max=1000ms) -
979.489054 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
979.502613 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.5595ms (max=1200ms) -
979.502613 Get Diagnostic Response Positive response was received. -
979.502613 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
979.502613 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.215.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
979.502613 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 215 -
979.502613 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.215.5. Wait: None
979.512613 1 Waited for 10.000 ms -
20.215.6. Wait 10ms: None
979.522613 1 Waited for 10.000 ms -
20.216. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 216)
20.216.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
979.522613 Diagnostic request 0x11, 0x01 -
979.523994 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.38061ms (max=1000ms) -
979.523994 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
979.532665 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.67155ms (max=1200ms) -
979.532665 Get Diagnostic Response Positive response was received. -
979.532665 Diagnostic response 0x51, 0x01 -
979.532665 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.216.2. (In for loop)Wait for the diagnostics to start: None
981.932665 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.216.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
981.932665 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
981.934166 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.50027ms (max=1000ms) -
981.934166 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
981.947775 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.6095ms (max=1200ms) -
981.947775 Get Diagnostic Response Positive response was received. -
981.947775 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
981.947775 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.216.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
981.947775 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 216 -
981.947775 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.216.5. Wait: None
981.957775 1 Waited for 10.000 ms -
20.216.6. Wait 10ms: None
981.967775 1 Waited for 10.000 ms -
20.217. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 217)
20.217.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
981.967775 Diagnostic request 0x11, 0x01 -
981.969186 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.41055ms (max=1000ms) -
981.969186 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
981.977826 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.64055ms (max=1200ms) -
981.977826 Get Diagnostic Response Positive response was received. -
981.977826 Diagnostic response 0x51, 0x01 -
981.977826 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.217.2. (In for loop)Wait for the diagnostics to start: None
984.377826 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.217.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
984.377826 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
984.379308 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.48195ms (max=1000ms) -
984.379308 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
984.392864 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.5555ms (max=1200ms) -
984.392864 Get Diagnostic Response Positive response was received. -
984.392864 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
984.392864 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.217.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
984.392864 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 217 -
984.392864 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.217.5. Wait: None
984.402864 1 Waited for 10.000 ms -
20.217.6. Wait 10ms: None
984.412864 1 Waited for 10.000 ms -
20.218. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 218)
20.218.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
984.412864 Diagnostic request 0x11, 0x01 -
984.414152 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.28867ms (max=1000ms) -
984.414152 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
984.422917 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.76503ms (max=1200ms) -
984.422917 Get Diagnostic Response Positive response was received. -
984.422917 Diagnostic response 0x51, 0x01 -
984.422917 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.218.2. (In for loop)Wait for the diagnostics to start: None
986.822917 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.218.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
986.822917 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
986.824429 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.51194ms (max=1000ms) -
986.824429 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
986.838041 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.6115ms (max=1200ms) -
986.838041 Get Diagnostic Response Positive response was received. -
986.838041 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
986.838041 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.218.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
986.838041 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 218 -
986.838041 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.218.5. Wait: None
986.848041 1 Waited for 10.000 ms -
20.218.6. Wait 10ms: None
986.858041 1 Waited for 10.000 ms -
20.219. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 219)
20.219.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
986.858041 Diagnostic request 0x11, 0x01 -
986.859369 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.32861ms (max=1000ms) -
986.859369 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
986.868096 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.72653ms (max=1200ms) -
986.868096 Get Diagnostic Response Positive response was received. -
986.868096 Diagnostic response 0x51, 0x01 -
986.868096 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.219.2. (In for loop)Wait for the diagnostics to start: None
989.268096 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.219.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
989.268096 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
989.269490 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.39409ms (max=1000ms) -
989.269490 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
989.283129 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.6395ms (max=1200ms) -
989.283129 Get Diagnostic Response Positive response was received. -
989.283129 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
989.283129 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.219.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
989.283129 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 219 -
989.283129 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.219.5. Wait: None
989.293129 1 Waited for 10.000 ms -
20.219.6. Wait 10ms: None
989.303129 1 Waited for 10.000 ms -
20.220. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 220)
20.220.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
989.303129 Diagnostic request 0x11, 0x01 -
989.304374 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.24458ms (max=1000ms) -
989.304374 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
989.313184 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.81053ms (max=1200ms) -
989.313184 Get Diagnostic Response Positive response was received. -
989.313184 Diagnostic response 0x51, 0x01 -
989.313184 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.220.2. (In for loop)Wait for the diagnostics to start: None
991.713184 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.220.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
991.713184 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
991.714534 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.34987ms (max=1000ms) -
991.714534 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
991.728200 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.6655ms (max=1200ms) -
991.728200 Get Diagnostic Response Positive response was received. -
991.728200 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
991.728200 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.220.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
991.728200 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 220 -
991.728200 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.220.5. Wait: None
991.738200 1 Waited for 10.000 ms -
20.220.6. Wait 10ms: None
991.748200 1 Waited for 10.000 ms -
20.221. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 221)
20.221.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
991.748200 Diagnostic request 0x11, 0x01 -
991.749476 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.27658ms (max=1000ms) -
991.749476 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
991.758252 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.77556ms (max=1200ms) -
991.758252 Get Diagnostic Response Positive response was received. -
991.758252 Diagnostic response 0x51, 0x01 -
991.758252 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.221.2. (In for loop)Wait for the diagnostics to start: None
994.158252 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.221.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
994.158252 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
994.159872 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.61956ms (max=1000ms) -
994.159872 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
994.173331 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.4595ms (max=1200ms) -
994.173331 Get Diagnostic Response Positive response was received. -
994.173331 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
994.173331 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.221.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
994.173331 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 221 -
994.173331 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.221.5. Wait: None
994.183331 1 Waited for 10.000 ms -
20.221.6. Wait 10ms: None
994.193331 1 Waited for 10.000 ms -
20.222. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 222)
20.222.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
994.193331 Diagnostic request 0x11, 0x01 -
994.194728 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.39659ms (max=1000ms) -
994.194728 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
994.203445 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.71758ms (max=1200ms) -
994.203445 Get Diagnostic Response Positive response was received. -
994.203445 Diagnostic response 0x51, 0x01 -
994.203445 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.222.2. (In for loop)Wait for the diagnostics to start: None
996.603445 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.222.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
996.603445 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
996.604974 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.52869ms (max=1000ms) -
996.604974 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
996.618467 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.4935ms (max=1200ms) -
996.618467 Get Diagnostic Response Positive response was received. -
996.618467 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
996.618467 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.222.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
996.618467 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 222 -
996.618467 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.222.5. Wait: None
996.628467 1 Waited for 10.000 ms -
20.222.6. Wait 10ms: None
996.638467 1 Waited for 10.000 ms -
20.223. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 223)
20.223.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
996.638467 Diagnostic request 0x11, 0x01 -
996.639778 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.31059ms (max=1000ms) -
996.639778 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
996.648519 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.74155ms (max=1200ms) -
996.648519 Get Diagnostic Response Positive response was received. -
996.648519 Diagnostic response 0x51, 0x01 -
996.648519 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.223.2. (In for loop)Wait for the diagnostics to start: None
999.048519 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.223.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
999.048519 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
999.050008 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.48805ms (max=1000ms) -
999.050008 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
999.063571 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.5635ms (max=1200ms) -
999.063571 Get Diagnostic Response Positive response was received. -
999.063571 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
999.063571 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.223.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
999.063571 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 223 -
999.063571 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.223.5. Wait: None
999.073571 1 Waited for 10.000 ms -
20.223.6. Wait 10ms: None
999.083571 1 Waited for 10.000 ms -
20.224. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 224)
20.224.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
999.083571 Diagnostic request 0x11, 0x01 -
999.084860 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.28856ms (max=1000ms) -
999.084860 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
999.093622 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.76255ms (max=1200ms) -
999.093622 Get Diagnostic Response Positive response was received. -
999.093622 Diagnostic response 0x51, 0x01 -
999.093622 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.224.2. (In for loop)Wait for the diagnostics to start: None
1001.493622 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.224.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
1001.493622 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
1001.495142 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.52031ms (max=1000ms) -
1001.495142 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
1001.508704 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.5615ms (max=1200ms) -
1001.508704 Get Diagnostic Response Positive response was received. -
1001.508704 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
1001.508704 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.224.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
1001.508704 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 224 -
1001.508704 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.224.5. Wait: None
1001.518704 1 Waited for 10.000 ms -
20.224.6. Wait 10ms: None
1001.528704 1 Waited for 10.000 ms -
20.225. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 225)
20.225.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
1001.528704 Diagnostic request 0x11, 0x01 -
1001.530154 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.45058ms (max=1000ms) -
1001.530154 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
1001.538756 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.60153ms (max=1200ms) -
1001.538756 Get Diagnostic Response Positive response was received. -
1001.538756 Diagnostic response 0x51, 0x01 -
1001.538756 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.225.2. (In for loop)Wait for the diagnostics to start: None
1003.938756 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.225.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
1003.938756 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
1003.940260 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.50388ms (max=1000ms) -
1003.940260 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
1003.953889 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.6295ms (max=1200ms) -
1003.953889 Get Diagnostic Response Positive response was received. -
1003.953889 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
1003.953889 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.225.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
1003.953889 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 225 -
1003.953889 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.225.5. Wait: None
1003.963889 1 Waited for 10.000 ms -
20.225.6. Wait 10ms: None
1003.973889 1 Waited for 10.000 ms -
20.226. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 226)
20.226.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
1003.973889 Diagnostic request 0x11, 0x01 -
1003.975264 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.37458ms (max=1000ms) -
1003.975264 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
1003.983940 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.67653ms (max=1200ms) -
1003.983940 Get Diagnostic Response Positive response was received. -
1003.983940 Diagnostic response 0x51, 0x01 -
1003.983940 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.226.2. (In for loop)Wait for the diagnostics to start: None
1006.383940 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.226.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
1006.383940 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
1006.385321 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.38033ms (max=1000ms) -
1006.385321 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
1006.399092 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.7715ms (max=1200ms) -
1006.399092 Get Diagnostic Response Positive response was received. -
1006.399092 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
1006.399092 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.226.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
1006.399092 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 226 -
1006.399092 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.226.5. Wait: None
1006.409092 1 Waited for 10.000 ms -
20.226.6. Wait 10ms: None
1006.419092 1 Waited for 10.000 ms -
20.227. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 227)
20.227.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
1006.419092 Diagnostic request 0x11, 0x01 -
1006.420425 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.33261ms (max=1000ms) -
1006.420425 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
1006.429148 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.72353ms (max=1200ms) -
1006.429148 Get Diagnostic Response Positive response was received. -
1006.429148 Diagnostic response 0x51, 0x01 -
1006.429148 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.227.2. (In for loop)Wait for the diagnostics to start: None
1008.829148 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.227.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
1008.829148 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
1008.830501 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.35266ms (max=1000ms) -
1008.830501 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
1008.844237 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.7355ms (max=1200ms) -
1008.844237 Get Diagnostic Response Positive response was received. -
1008.844237 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
1008.844237 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.227.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
1008.844237 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 227 -
1008.844237 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.227.5. Wait: None
1008.854237 1 Waited for 10.000 ms -
20.227.6. Wait 10ms: None
1008.864237 1 Waited for 10.000 ms -
20.228. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 228)
20.228.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
1008.864237 Diagnostic request 0x11, 0x01 -
1008.865559 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.32255ms (max=1000ms) -
1008.865559 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
1008.874288 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.72853ms (max=1200ms) -
1008.874288 Get Diagnostic Response Positive response was received. -
1008.874288 Diagnostic response 0x51, 0x01 -
1008.874288 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.228.2. (In for loop)Wait for the diagnostics to start: None
1011.274288 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.228.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
1011.274288 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
1011.276005 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.71766ms (max=1000ms) -
1011.276005 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
1011.289415 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.4095ms (max=1200ms) -
1011.289415 Get Diagnostic Response Positive response was received. -
1011.289415 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
1011.289415 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.228.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
1011.289415 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 228 -
1011.289415 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.228.5. Wait: None
1011.299415 1 Waited for 10.000 ms -
20.228.6. Wait 10ms: None
1011.309415 1 Waited for 10.000 ms -
20.229. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 229)
20.229.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
1011.309415 Diagnostic request 0x11, 0x01 -
1011.311127 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.71258ms (max=1000ms) -
1011.311127 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
1011.319466 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.33853ms (max=1200ms) -
1011.319466 Get Diagnostic Response Positive response was received. -
1011.319466 Diagnostic response 0x51, 0x01 -
1011.319466 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.229.2. (In for loop)Wait for the diagnostics to start: None
1013.719466 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.229.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
1013.719466 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
1013.721127 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.66155ms (max=1000ms) -
1013.721127 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
1013.734655 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.5275ms (max=1200ms) -
1013.734655 Get Diagnostic Response Positive response was received. -
1013.734655 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
1013.734655 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.229.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
1013.734655 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 229 -
1013.734655 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.229.5. Wait: None
1013.744655 1 Waited for 10.000 ms -
20.229.6. Wait 10ms: None
1013.754655 1 Waited for 10.000 ms -
20.230. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 230)
20.230.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
1013.754655 Diagnostic request 0x11, 0x01 -
1013.756062 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.40659ms (max=1000ms) -
1013.756062 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
1013.764709 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.64753ms (max=1200ms) -
1013.764709 Get Diagnostic Response Positive response was received. -
1013.764709 Diagnostic response 0x51, 0x01 -
1013.764709 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.230.2. (In for loop)Wait for the diagnostics to start: None
1016.164709 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.230.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
1016.164709 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
1016.166198 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.48845ms (max=1000ms) -
1016.166198 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
1016.179759 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.5615ms (max=1200ms) -
1016.179759 Get Diagnostic Response Positive response was received. -
1016.179759 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
1016.179759 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.230.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
1016.179759 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 230 -
1016.179759 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.230.5. Wait: None
1016.189759 1 Waited for 10.000 ms -
20.230.6. Wait 10ms: None
1016.199759 1 Waited for 10.000 ms -
20.231. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 231)
20.231.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
1016.199759 Diagnostic request 0x11, 0x01 -
1016.201452 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.69295ms (max=1000ms) -
1016.201452 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
1016.209815 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.36355ms (max=1200ms) -
1016.209815 Get Diagnostic Response Positive response was received. -
1016.209815 Diagnostic response 0x51, 0x01 -
1016.209815 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.231.2. (In for loop)Wait for the diagnostics to start: None
1018.609815 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.231.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
1018.609815 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
1018.611391 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.57527ms (max=1000ms) -
1018.611391 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
1018.624876 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.4855ms (max=1200ms) -
1018.624876 Get Diagnostic Response Positive response was received. -
1018.624876 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
1018.624876 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.231.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
1018.624876 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 231 -
1018.624876 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.231.5. Wait: None
1018.634876 1 Waited for 10.000 ms -
20.231.6. Wait 10ms: None
1018.644876 1 Waited for 10.000 ms -
20.232. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 232)
20.232.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
1018.644876 Diagnostic request 0x11, 0x01 -
1018.646299 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.42258ms (max=1000ms) -
1018.646299 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
1018.654931 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.63253ms (max=1200ms) -
1018.654931 Get Diagnostic Response Positive response was received. -
1018.654931 Diagnostic response 0x51, 0x01 -
1018.654931 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.232.2. (In for loop)Wait for the diagnostics to start: None
1021.054931 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.232.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
1021.054931 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
1021.056444 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.51241ms (max=1000ms) -
1021.056444 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
1021.069923 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.4795ms (max=1200ms) -
1021.069923 Get Diagnostic Response Positive response was received. -
1021.069923 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
1021.069923 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.232.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
1021.069923 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 232 -
1021.069923 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.232.5. Wait: None
1021.079923 1 Waited for 10.000 ms -
20.232.6. Wait 10ms: None
1021.089923 1 Waited for 10.000 ms -
20.233. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 233)
20.233.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
1021.089923 Diagnostic request 0x11, 0x01 -
1021.091414 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.49055ms (max=1000ms) -
1021.091414 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
1021.099977 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.56353ms (max=1200ms) -
1021.099977 Get Diagnostic Response Positive response was received. -
1021.099977 Diagnostic response 0x51, 0x01 -
1021.099977 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.233.2. (In for loop)Wait for the diagnostics to start: None
1023.499977 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.233.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
1023.499977 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
1023.501567 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.58986ms (max=1000ms) -
1023.501567 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
1023.514957 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.3895ms (max=1200ms) -
1023.514957 Get Diagnostic Response Positive response was received. -
1023.514957 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
1023.514957 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.233.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
1023.514957 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 233 -
1023.514957 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.233.5. Wait: None
1023.524957 1 Waited for 10.000 ms -
20.233.6. Wait 10ms: None
1023.534957 1 Waited for 10.000 ms -
20.234. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 234)
20.234.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
1023.534957 Diagnostic request 0x11, 0x01 -
1023.536305 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.34859ms (max=1000ms) -
1023.536305 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
1023.545012 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.70655ms (max=1200ms) -
1023.545012 Get Diagnostic Response Positive response was received. -
1023.545012 Diagnostic response 0x51, 0x01 -
1023.545012 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.234.2. (In for loop)Wait for the diagnostics to start: None
1025.945012 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.234.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
1025.945012 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
1025.946624 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.61233ms (max=1000ms) -
1025.946624 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
1025.960010 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.3855ms (max=1200ms) -
1025.960010 Get Diagnostic Response Positive response was received. -
1025.960010 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
1025.960010 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.234.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
1025.960010 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 234 -
1025.960010 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.234.5. Wait: None
1025.970010 1 Waited for 10.000 ms -
20.234.6. Wait 10ms: None
1025.980010 1 Waited for 10.000 ms -
20.235. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 235)
20.235.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
1025.980010 Diagnostic request 0x11, 0x01 -
1025.981478 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.46858ms (max=1000ms) -
1025.981478 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
1025.990064 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.58555ms (max=1200ms) -
1025.990064 Get Diagnostic Response Positive response was received. -
1025.990064 Diagnostic response 0x51, 0x01 -
1025.990064 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.235.2. (In for loop)Wait for the diagnostics to start: None
1028.390064 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.235.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
1028.390064 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
1028.391593 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.52947ms (max=1000ms) -
1028.391593 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
1028.405207 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.6136ms (max=1200ms) -
1028.405207 Get Diagnostic Response Positive response was received. -
1028.405207 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
1028.405207 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.235.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
1028.405207 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 235 -
1028.405207 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.235.5. Wait: None
1028.415207 1 Waited for 10.000 ms -
20.235.6. Wait 10ms: None
1028.425207 1 Waited for 10.000 ms -
20.236. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 236)
20.236.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
1028.425207 Diagnostic request 0x11, 0x01 -
1028.426495 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.28855ms (max=1000ms) -
1028.426495 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
1028.435197 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.70153ms (max=1200ms) -
1028.435197 Get Diagnostic Response Positive response was received. -
1028.435197 Diagnostic response 0x51, 0x01 -
1028.435197 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.236.2. (In for loop)Wait for the diagnostics to start: None
1030.835197 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.236.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
1030.835197 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
1030.836572 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.37481ms (max=1000ms) -
1030.836572 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
1030.850317 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.7455ms (max=1200ms) -
1030.850317 Get Diagnostic Response Positive response was received. -
1030.850317 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
1030.850317 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.236.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
1030.850317 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 236 -
1030.850317 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.236.5. Wait: None
1030.860317 1 Waited for 10.000 ms -
20.236.6. Wait 10ms: None
1030.870317 1 Waited for 10.000 ms -
20.237. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 237)
20.237.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
1030.870317 Diagnostic request 0x11, 0x01 -
1030.871790 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.47258ms (max=1000ms) -
1030.871790 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
1030.880371 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.58156ms (max=1200ms) -
1030.880371 Get Diagnostic Response Positive response was received. -
1030.880371 Diagnostic response 0x51, 0x01 -
1030.880371 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.237.2. (In for loop)Wait for the diagnostics to start: None
1033.280371 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.237.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
1033.280371 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
1033.281934 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.56305ms (max=1000ms) -
1033.281934 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
1033.295418 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.4835ms (max=1200ms) -
1033.295418 Get Diagnostic Response Positive response was received. -
1033.295418 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
1033.295418 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.237.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
1033.295418 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 237 -
1033.295418 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.237.5. Wait: None
1033.305418 1 Waited for 10.000 ms -
20.237.6. Wait 10ms: None
1033.315418 1 Waited for 10.000 ms -
20.238. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 238)
20.238.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
1033.315418 Diagnostic request 0x11, 0x01 -
1033.316895 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.47658ms (max=1000ms) -
1033.316895 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
1033.325471 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.57656ms (max=1200ms) -
1033.325471 Get Diagnostic Response Positive response was received. -
1033.325471 Diagnostic response 0x51, 0x01 -
1033.325471 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.238.2. (In for loop)Wait for the diagnostics to start: None
1035.725471 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.238.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
1035.725471 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
1035.726974 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.50244ms (max=1000ms) -
1035.726974 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
1035.740621 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.6475ms (max=1200ms) -
1035.740621 Get Diagnostic Response Positive response was received. -
1035.740621 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
1035.740621 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.238.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
1035.740621 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 238 -
1035.740621 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.238.5. Wait: None
1035.750621 1 Waited for 10.000 ms -
20.238.6. Wait 10ms: None
1035.760621 1 Waited for 10.000 ms -
20.239. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 239)
20.239.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
1035.760621 Diagnostic request 0x11, 0x01 -
1035.762050 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.42856ms (max=1000ms) -
1035.762050 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
1035.770673 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.62355ms (max=1200ms) -
1035.770673 Get Diagnostic Response Positive response was received. -
1035.770673 Diagnostic response 0x51, 0x01 -
1035.770673 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.239.2. (In for loop)Wait for the diagnostics to start: None
1038.170673 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.239.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
1038.170673 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
1038.172141 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.46823ms (max=1000ms) -
1038.172141 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
1038.185783 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.6415ms (max=1200ms) -
1038.185783 Get Diagnostic Response Positive response was received. -
1038.185783 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
1038.185783 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.239.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
1038.185783 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 239 -
1038.185783 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.239.5. Wait: None
1038.195783 1 Waited for 10.000 ms -
20.239.6. Wait 10ms: None
1038.205783 1 Waited for 10.000 ms -
20.240. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 240)
20.240.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
1038.205783 Diagnostic request 0x11, 0x01 -
1038.207202 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.41872ms (max=1000ms) -
1038.207202 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
1038.215835 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.63356ms (max=1200ms) -
1038.215835 Get Diagnostic Response Positive response was received. -
1038.215835 Diagnostic response 0x51, 0x01 -
1038.215835 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.240.2. (In for loop)Wait for the diagnostics to start: None
1040.615835 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.240.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
1040.615835 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
1040.617365 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.53008ms (max=1000ms) -
1040.617365 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
1040.630943 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.5775ms (max=1200ms) -
1040.630943 Get Diagnostic Response Positive response was received. -
1040.630943 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
1040.630943 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.240.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
1040.630943 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 240 -
1040.630943 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.240.5. Wait: None
1040.640943 1 Waited for 10.000 ms -
20.240.6. Wait 10ms: None
1040.650943 1 Waited for 10.000 ms -
20.241. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 241)
20.241.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
1040.650943 Diagnostic request 0x11, 0x01 -
1040.652281 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.33855ms (max=1000ms) -
1040.652281 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
1040.660996 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.71455ms (max=1200ms) -
1040.660996 Get Diagnostic Response Positive response was received. -
1040.660996 Diagnostic response 0x51, 0x01 -
1040.660996 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.241.2. (In for loop)Wait for the diagnostics to start: None
1043.060996 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.241.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
1043.060996 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
1043.062419 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.42289ms (max=1000ms) -
1043.062419 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
1043.076160 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.7415ms (max=1200ms) -
1043.076160 Get Diagnostic Response Positive response was received. -
1043.076160 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
1043.076160 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.241.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
1043.076160 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 241 -
1043.076160 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.241.5. Wait: None
1043.086160 1 Waited for 10.000 ms -
20.241.6. Wait 10ms: None
1043.096160 1 Waited for 10.000 ms -
20.242. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 242)
20.242.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
1043.096160 Diagnostic request 0x11, 0x01 -
1043.097447 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.28656ms (max=1000ms) -
1043.097447 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
1043.106210 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.76355ms (max=1200ms) -
1043.106210 Get Diagnostic Response Positive response was received. -
1043.106210 Diagnostic response 0x51, 0x01 -
1043.106210 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.242.2. (In for loop)Wait for the diagnostics to start: None
1045.506210 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.242.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
1045.506210 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
1045.507581 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.37089ms (max=1000ms) -
1045.507581 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
1045.521251 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.6695ms (max=1200ms) -
1045.521251 Get Diagnostic Response Positive response was received. -
1045.521251 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
1045.521251 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.242.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
1045.521251 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 242 -
1045.521251 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.242.5. Wait: None
1045.531251 1 Waited for 10.000 ms -
20.242.6. Wait 10ms: None
1045.541251 1 Waited for 10.000 ms -
20.243. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 243)
20.243.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
1045.541251 Diagnostic request 0x11, 0x01 -
1045.542785 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.53458ms (max=1000ms) -
1045.542785 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
1045.551304 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.51855ms (max=1200ms) -
1045.551304 Get Diagnostic Response Positive response was received. -
1045.551304 Diagnostic response 0x51, 0x01 -
1045.551304 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.243.2. (In for loop)Wait for the diagnostics to start: None
1047.951304 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.243.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
1047.951304 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
1047.952794 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.49042ms (max=1000ms) -
1047.952794 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
1047.966458 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.6635ms (max=1200ms) -
1047.966458 Get Diagnostic Response Positive response was received. -
1047.966458 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
1047.966458 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.243.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
1047.966458 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 243 -
1047.966458 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.243.5. Wait: None
1047.976458 1 Waited for 10.000 ms -
20.243.6. Wait 10ms: None
1047.986458 1 Waited for 10.000 ms -
20.244. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 244)
20.244.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
1047.986458 Diagnostic request 0x11, 0x01 -
1047.987778 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.32058ms (max=1000ms) -
1047.987778 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
1047.996511 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.73308ms (max=1200ms) -
1047.996511 Get Diagnostic Response Positive response was received. -
1047.996511 Diagnostic response 0x51, 0x01 -
1047.996511 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.244.2. (In for loop)Wait for the diagnostics to start: None
1050.396511 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.244.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
1050.396511 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
1050.397944 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.43284ms (max=1000ms) -
1050.397944 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
1050.411716 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.7719ms (max=1200ms) -
1050.411716 Get Diagnostic Response Positive response was received. -
1050.411716 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
1050.411716 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.244.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
1050.411716 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 244 -
1050.411716 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.244.5. Wait: None
1050.421716 1 Waited for 10.000 ms -
20.244.6. Wait 10ms: None
1050.431716 1 Waited for 10.000 ms -
20.245. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 245)
20.245.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
1050.431716 Diagnostic request 0x11, 0x01 -
1050.433105 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.38859ms (max=1000ms) -
1050.433105 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
1050.441773 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.66855ms (max=1200ms) -
1050.441773 Get Diagnostic Response Positive response was received. -
1050.441773 Diagnostic response 0x51, 0x01 -
1050.441773 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.245.2. (In for loop)Wait for the diagnostics to start: None
1052.841773 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.245.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
1052.841773 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
1052.843331 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.55731ms (max=1000ms) -
1052.843331 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
1052.856894 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.5635ms (max=1200ms) -
1052.856894 Get Diagnostic Response Positive response was received. -
1052.856894 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
1052.856894 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.245.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
1052.856894 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 245 -
1052.856894 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.245.5. Wait: None
1052.866894 1 Waited for 10.000 ms -
20.245.6. Wait 10ms: None
1052.876894 1 Waited for 10.000 ms -
20.246. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 246)
20.246.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
1052.876894 Diagnostic request 0x11, 0x01 -
1052.878297 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.40255ms (max=1000ms) -
1052.878297 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
1052.886951 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.65461ms (max=1200ms) -
1052.886951 Get Diagnostic Response Positive response was received. -
1052.886951 Diagnostic response 0x51, 0x01 -
1052.886951 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.246.2. (In for loop)Wait for the diagnostics to start: None
1055.286951 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.246.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
1055.286951 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
1055.288431 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.48019ms (max=1000ms) -
1055.288431 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
1055.302037 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.6055ms (max=1200ms) -
1055.302037 Get Diagnostic Response Positive response was received. -
1055.302037 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
1055.302037 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.246.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
1055.302037 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 246 -
1055.302037 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.246.5. Wait: None
1055.312037 1 Waited for 10.000 ms -
20.246.6. Wait 10ms: None
1055.322037 1 Waited for 10.000 ms -
20.247. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 247)
20.247.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
1055.322037 Diagnostic request 0x11, 0x01 -
1055.323406 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.36856ms (max=1000ms) -
1055.323406 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
1055.332089 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.68353ms (max=1200ms) -
1055.332089 Get Diagnostic Response Positive response was received. -
1055.332089 Diagnostic response 0x51, 0x01 -
1055.332089 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.247.2. (In for loop)Wait for the diagnostics to start: None
1057.732089 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.247.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
1057.732089 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
1057.733534 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.44512ms (max=1000ms) -
1057.733534 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
1057.747230 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.6955ms (max=1200ms) -
1057.747230 Get Diagnostic Response Positive response was received. -
1057.747230 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
1057.747230 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.247.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
1057.747230 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 247 -
1057.747230 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.247.5. Wait: None
1057.757230 1 Waited for 10.000 ms -
20.247.6. Wait 10ms: None
1057.767230 1 Waited for 10.000 ms -
20.248. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 248)
20.248.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
1057.767230 Diagnostic request 0x11, 0x01 -
1057.768468 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.23856ms (max=1000ms) -
1057.768468 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
1057.777283 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.81452ms (max=1200ms) -
1057.777283 Get Diagnostic Response Positive response was received. -
1057.777283 Diagnostic response 0x51, 0x01 -
1057.777283 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.248.2. (In for loop)Wait for the diagnostics to start: None
1060.177283 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.248.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
1060.177283 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
1060.178913 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.62992ms (max=1000ms) -
1060.178913 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
1060.192354 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.4415ms (max=1200ms) -
1060.192354 Get Diagnostic Response Positive response was received. -
1060.192354 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
1060.192354 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.248.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
1060.192354 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 248 -
1060.192354 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.248.5. Wait: None
1060.202354 1 Waited for 10.000 ms -
20.248.6. Wait 10ms: None
1060.212354 1 Waited for 10.000 ms -
20.249. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 249)
20.249.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
1060.212354 Diagnostic request 0x11, 0x01 -
1060.213707 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.35266ms (max=1000ms) -
1060.213707 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
1060.222406 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.69953ms (max=1200ms) -
1060.222406 Get Diagnostic Response Positive response was received. -
1060.222406 Diagnostic response 0x51, 0x01 -
1060.222406 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.249.2. (In for loop)Wait for the diagnostics to start: None
1062.622406 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.249.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
1062.622406 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
1062.623915 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.50898ms (max=1000ms) -
1062.623915 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
1062.637495 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.5795ms (max=1200ms) -
1062.637495 Get Diagnostic Response Positive response was received. -
1062.637495 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
1062.637495 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.249.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
1062.637495 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 249 -
1062.637495 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.249.5. Wait: None
1062.647495 1 Waited for 10.000 ms -
20.249.6. Wait 10ms: None
1062.657495 1 Waited for 10.000 ms -
20.250. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 250)
20.250.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
1062.657495 Diagnostic request 0x11, 0x01 -
1062.658825 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.33056ms (max=1000ms) -
1062.658825 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
1062.667552 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.72655ms (max=1200ms) -
1062.667552 Get Diagnostic Response Positive response was received. -
1062.667552 Diagnostic response 0x51, 0x01 -
1062.667552 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.250.2. (In for loop)Wait for the diagnostics to start: None
1065.067552 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.250.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
1065.067552 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
1065.069052 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.4997ms (max=1000ms) -
1065.069052 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
1065.082749 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.6975ms (max=1200ms) -
1065.082749 Get Diagnostic Response Positive response was received. -
1065.082749 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
1065.082749 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.250.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
1065.082749 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 250 -
1065.082749 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.250.5. Wait: None
1065.092749 1 Waited for 10.000 ms -
20.250.6. Wait 10ms: None
1065.102749 1 Waited for 10.000 ms -
20.251. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 251)
20.251.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
1065.102749 Diagnostic request 0x11, 0x01 -
1065.104084 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.33455ms (max=1000ms) -
1065.104084 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
1065.112808 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.72456ms (max=1200ms) -
1065.112808 Get Diagnostic Response Positive response was received. -
1065.112808 Diagnostic response 0x51, 0x01 -
1065.112808 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.251.2. (In for loop)Wait for the diagnostics to start: None
1067.512808 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.251.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
1067.512808 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
1067.514308 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.49994ms (max=1000ms) -
1067.514308 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
1067.528006 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.6975ms (max=1200ms) -
1067.528006 Get Diagnostic Response Positive response was received. -
1067.528006 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
1067.528006 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.251.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
1067.528006 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 251 -
1067.528006 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.251.5. Wait: None
1067.538006 1 Waited for 10.000 ms -
20.251.6. Wait 10ms: None
1067.548006 1 Waited for 10.000 ms -
20.252. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 252)
20.252.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
1067.548006 Diagnostic request 0x11, 0x01 -
1067.549380 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.37459ms (max=1000ms) -
1067.549380 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
1067.558057 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.67652ms (max=1200ms) -
1067.558057 Get Diagnostic Response Positive response was received. -
1067.558057 Diagnostic response 0x51, 0x01 -
1067.558057 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.252.2. (In for loop)Wait for the diagnostics to start: None
1069.958057 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.252.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
1069.958057 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
1069.959553 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.49595ms (max=1000ms) -
1069.959553 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
1069.973228 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.6755ms (max=1200ms) -
1069.973228 Get Diagnostic Response Positive response was received. -
1069.973228 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
1069.973228 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.252.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
1069.973228 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 252 -
1069.973228 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.252.5. Wait: None
1069.983228 1 Waited for 10.000 ms -
20.252.6. Wait 10ms: None
1069.993228 1 Waited for 10.000 ms -
20.253. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 253)
20.253.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
1069.993228 Diagnostic request 0x11, 0x01 -
1069.994493 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.26458ms (max=1000ms) -
1069.994493 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
1070.003339 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.84656ms (max=1200ms) -
1070.003339 Get Diagnostic Response Positive response was received. -
1070.003339 Diagnostic response 0x51, 0x01 -
1070.003339 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.253.2. (In for loop)Wait for the diagnostics to start: None
1072.403339 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.253.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
1072.403339 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
1072.404810 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.47028ms (max=1000ms) -
1072.404810 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
1072.418439 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.6295ms (max=1200ms) -
1072.418439 Get Diagnostic Response Positive response was received. -
1072.418439 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
1072.418439 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.253.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
1072.418439 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 253 -
1072.418439 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.253.5. Wait: None
1072.428439 1 Waited for 10.000 ms -
20.253.6. Wait 10ms: None
1072.438439 1 Waited for 10.000 ms -
20.254. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 254)
20.254.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
1072.438439 Diagnostic request 0x11, 0x01 -
1072.439818 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.37859ms (max=1000ms) -
1072.439818 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
1072.448492 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.67453ms (max=1200ms) -
1072.448492 Get Diagnostic Response Positive response was received. -
1072.448492 Diagnostic response 0x51, 0x01 -
1072.448492 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.254.2. (In for loop)Wait for the diagnostics to start: None
1074.848492 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.254.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
1074.848492 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
1074.849955 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.46234ms (max=1000ms) -
1074.849955 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
1074.863672 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.7175ms (max=1200ms) -
1074.863672 Get Diagnostic Response Positive response was received. -
1074.863672 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
1074.863672 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.254.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
1074.863672 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 254 -
1074.863672 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.254.5. Wait: None
1074.873672 1 Waited for 10.000 ms -
20.254.6. Wait 10ms: None
1074.883672 1 Waited for 10.000 ms -
20.255. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 255)
20.255.1. (In for loop) Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
1074.883672 Diagnostic request 0x11, 0x01 -
1074.885081 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.40858ms (max=1000ms) -
1074.885081 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
1074.893725 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.64456ms (max=1200ms) -
1074.893725 Get Diagnostic Response Positive response was received. -
1074.893725 Diagnostic response 0x51, 0x01 -
1074.893725 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.255.2. (In for loop)Wait for the diagnostics to start: None
1077.293725 1 Waited for 2400.000 (diagnostic_start_time) ms -
20.255.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
1077.293725 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
1077.295232 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.50708ms (max=1000ms) -
1077.295232 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
1077.308834 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.6015ms (max=1200ms) -
1077.308834 Get Diagnostic Response Positive response was received. -
1077.308834 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
1077.308834 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
20.255.4. Check OCC1 value Expected: OCC1 equal expected value: Failed
1077.308834 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 255 -
1077.308834 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
20.255.5. Wait: None
1077.318834 1 Waited for 10.000 ms -
20.255.6. Wait 10ms: None
1077.328834 1 Waited for 10.000 ms -
21. Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
1077.328834 Diagnostic request 0x11, 0x01 -
1077.330054 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.22059ms (max=1000ms) -
1077.330054 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
1077.338884 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.82955ms (max=1200ms) -
1077.338884 Get Diagnostic Response Positive response was received. -
1077.338884 Diagnostic response 0x51, 0x01 -
1077.338884 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
22. Wait for the diagnostics to start: None
1079.738884 1 Waited for 2400.000 (diagnostic_start_time) ms -
23. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
1079.738884 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
1079.740360 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.47647ms (max=1000ms) -
1079.740360 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
1079.754066 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.7055ms (max=1200ms) -
1079.754066 Get Diagnostic Response Positive response was received. -
1079.754066 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
1079.754066 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
24. Check OCC1 value Expected: OCC1 equal expected value: Failed
1079.754066 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 255 -
1079.754066 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
25. Wait: None
1079.764066 1 Waited for 10.000 ms -
26. Wait 5s: None
1084.764066 1 Waited for 5.000 s -
27. Change the state of the relay, Expected: Park 1 button is pressed: Passed
1084.764066 Change Relay State Relay vt2820_channel_6 - Relay 6 state was changed to PUSHED pass
28. Change the state of the relay, Expected: Park 2 button is pressed: Passed
1084.764066 Change Relay State Relay vt2820_channel_7 - Relay 7 state was changed to PUSHED pass
29. Wait for close relay: None
1084.769066 1 Waited for 5.000 ms -
30. Check that the SWMRiLvrDiagRiLvrDiag value has been set to 2 within 200s Expected: The signal has been set: Passed
1264.828316 Resume reason Resumed on signal: CAN signal 'SWMRiLvrDiagRiLvrDiag' Elapsed time=180059ms (max=200000ms) -
1264.828316 1
[−] Waited for occurrence of 1 value condition and signal updates.
Symbol Op. Reference value Actual Result
CAN signal 'SWMRiLvrDiagRiLvrDiag' == 2 2 pass
pass
31. Wait for 10s until the DTC reached TestFailed Limit : None
1280.828316 1 Waited for 16.000 s -
32. Change the state of the relay, Expected: Park 1 button not is pressed: Passed
1280.828316 Change Relay State Relay vt2820_channel_6 - Relay 6 state was changed to RELEASED pass
33. Change the state of the relay, Expected: Park 2 button not is pressed: Passed
1280.828316 Change Relay State Relay vt2820_channel_7 - Relay 7 state was changed to RELEASED pass
34. Wait for open relay: None
1280.838316 1 Waited for 10.000 ms -
35. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
1280.838316 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
1280.839891 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.57517ms (max=1000ms) -
1280.839891 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
1280.853644 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.7531ms (max=1200ms) -
1280.853644 Get Diagnostic Response Positive response was received. -
1280.853644 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x2F, 0x01, 0x00 -
1280.853644 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
36. Check OCC1 value Expected: OCC1 equal expected value: Passed
1280.853644 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 0 -
1280.853644 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 0 pass
pass
37. Wait: None
1280.863644 1 Waited for 10.000 ms -
38. Wait 20s : None
1300.863644 1 Waited for 20.000 s -
39. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
1300.863644 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
1300.865170 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.52597ms (max=1000ms) -
1300.865170 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
1300.883573 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=18.4027ms (max=1200ms) -
1300.883573 Get Diagnostic Response Positive response was received. -
1300.883573 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x2E, 0x01, 0x00 -
1300.883573 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
40. Check OCC1 value Expected: OCC1 equal expected value: Passed
1300.883573 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 0 -
1300.883573 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 0 pass
pass
41. Wait: None
1300.893573 1 Waited for 10.000 ms -
42. Wait 10ms: None
1300.903573 1 Waited for 10.000 ms -
43. Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
1300.903573 Diagnostic request 0x11, 0x01 -
1300.904879 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.30619ms (max=1000ms) -
1300.904879 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
1300.913538 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.65955ms (max=1200ms) -
1300.913538 Get Diagnostic Response Positive response was received. -
1300.913538 Diagnostic response 0x51, 0x01 -
1300.913538 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
44. Wait for the diagnostics to start: None
1303.313538 1 Waited for 2400.000 (diagnostic_start_time) ms -
45. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
1303.313538 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
1303.315099 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.56067ms (max=1000ms) -
1303.315099 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
1303.330743 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=15.644ms (max=1200ms) -
1303.330743 Get Diagnostic Response Positive response was received. -
1303.330743 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x6D, 0x01, 0x00 -
1303.330743 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
46. Check OCC1 value Expected: OCC1 equal expected value: Passed
1303.330743 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 0 -
1303.330743 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 0 pass
pass
47. Wait: None
1303.340743 1 Waited for 10.000 ms -
48. Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
1303.340743 Diagnostic request 0x11, 0x01 -
1303.342064 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.32136ms (max=1000ms) -
1303.342064 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
1303.350633 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.5688ms (max=1200ms) -
1303.350633 Get Diagnostic Response Positive response was received. -
1303.350633 Diagnostic response 0x51, 0x01 -
1303.350633 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
49. Wait for the diagnostics to start: None
1305.750633 1 Waited for 2400.000 (diagnostic_start_time) ms -
50. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
1305.750633 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
1305.752112 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.47894ms (max=1000ms) -
1305.752112 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
1305.767314 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=15.202ms (max=1200ms) -
1305.767314 Get Diagnostic Response Positive response was received. -
1305.767314 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x6D, 0x01, 0x00 -
1305.767314 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
51. Check OCC1 value Expected: OCC1 equal expected value: Failed
1305.767314 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 1 -
1305.767314 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 1 fail
fail
52. Wait: None
1305.777314 1 Waited for 10.000 ms -
Completion of Test Case
Timestamp Test Step Description Result
1. Wait 10ms: None
1305.787314 1 Waited for 10.000 ms -
2. Send diagnostic request "Clear Diagnostic Information" Expected: Positive response: Passed
1305.788691 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.37711ms (max=1000ms) -
1305.788691 Clear Diagnostic Information Request Clear Diagnostic Information was succesfully transmitted. -
1305.808343 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=19.6518ms (max=1200ms) -
1305.808343 Get Diagnostic Response Positive response was received. -
1305.808343 Diagnostic response 0x54 -
1305.808343 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
1305.808343 VT System Cards Configuration General-Purpose Relay Module - M2_VT2820 -
3. Change the state of the relay, Expected: VCC line connected to DUT: Passed
1305.808343 Change Relay State Relay vt2820_channel_13 - Relay 13 state was changed to RELEASED pass
4. Change the state of the relay, Expected: GND line connected to DUT: Passed
1305.808343 Change Relay State Relay vt2820_channel_14 - Relay 14 state was changed to RELEASED pass
5. Set the supply voltage of the DUT, Expected: Voltage = 12.0 V: Passed
5.1. VTS_Set_Power_Supply_Voltage_RangeZeroTo28V: Passed
1305.808343 Set power supply voltage Voltage set properly to 0.000000 V on vt2816_13 channel pass
6. Wait for configuration to be set: None
1305.908343 1 Waited for 100.000 (setup_time_1) ms -
[−] 1.3.3 B183F2A - OCC 2 Fault free operation cycles since first failed: Failed
Test case begin: 2024-06-19 15:15:30 (logging timestamp 1305.908343)
Test case end: 2024-06-19 16:38:09 (logging timestamp 6264.471962)

Link (managed by: vTESTstudio Traceability): REQ-90116v4 Support for Operation Cycle Counter 2 - Fault free operation cycles since first failed

Link (managed by: vTESTstudio Traceability): DTC 17 - Right Stalk General Signal Failures Signal Stuck In Range

Link (managed by: vTESTstudio Traceability): REQ-90105v4 Compliance to ISO 14229-1

Attributes
Safety Level: QM
Priority: Normal
Type: Automated
[expand test steps] [collapse test steps]
Preparation of Test Case
Timestamp Test Step Description Result
1305.908343 VT System Cards Configuration General-Purpose Relay Module - M2_VT2820 -
1305.908343 VT System Cards Configuration General-Purpose Analog I/O Module - M4_VT2816 -
1305.908343 VT System Cards Configuration General-Purpose Digital I/O Module - M5_VT2848 -
1305.908343 VT System Cards Configuration Network Module - M1_VT6204 -
1305.908343 VT System Cards Configuration Serial Interface Module - M6_VT2710 -
1305.908343 VT System Cards Configuration General-Purpose Relay Module - M2_VT2820 -
1. Change the state of the relay, Expected: VCC line connected to DUT: Passed
1305.908343 Change Relay State Relay vt2820_channel_13 - Relay 13 state was changed to PUSHED pass
2. Change the state of the relay, Expected: GND line connected to DUT: Passed
1305.908343 Change Relay State Relay vt2820_channel_14 - Relay 14 state was changed to PUSHED pass
3. Set the supply voltage of the DUT, Expected: Voltage = 12.0 V: Passed
3.1. VTS_Set_Power_Supply_Voltage_RangeZeroTo28V: Passed
1305.908343 Set power supply voltage Voltage set properly to 12.000000 V on vt2816_13 channel pass
4. Wait for configuration to be set: None
1306.008343 1 Waited for 100.000 (setup_time_1) ms -
5. Wait for start diagnostic: None
1308.408343 1 Waited for 2400.000 (diagnostic_start_time) ms -
Main Part of Test Case
Timestamp Test Step Description Result
1. Send diagnostic request "Clear Diagnostic Information" Expected: Positive response: Passed
1308.409719 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.37639ms (max=1000ms) -
1308.409719 Clear Diagnostic Information Request Clear Diagnostic Information was succesfully transmitted. -
1308.427393 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.674ms (max=1200ms) -
1308.427393 Get Diagnostic Response Positive response was received. -
1308.427393 Diagnostic response 0x54 -
1308.427393 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
2. Wait for TRC EN: None
1311.027393 1 Waited for 2600.000 ms -
3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
1311.027393 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
1311.028961 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.56719ms (max=1000ms) -
1311.028961 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
1311.046405 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.4449ms (max=1200ms) -
1311.046405 Get Diagnostic Response Positive response was received. -
1311.046405 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
1311.046405 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
4. Check OCC2 value Expected: OCC2 equal expected value: Passed
1311.046405 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 0 -
1311.046405 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 0 pass
pass
5. Wait for FDC10 reached TestPass limit: None
1327.046405 1 Waited for 16.000 s -
6. Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
1327.046405 Diagnostic request 0x11, 0x01 -
1327.047870 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.46442ms (max=1000ms) -
1327.047870 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
1327.056246 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.3762ms (max=1200ms) -
1327.056246 Get Diagnostic Response Positive response was received. -
1327.056246 Diagnostic response 0x51, 0x01 -
1327.056246 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
7. Wait for start diagnostic: None
1329.456246 1 Waited for 2400.000 (diagnostic_start_time) ms -
8. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
1329.456246 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
1329.458021 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.77458ms (max=1000ms) -
1329.458021 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
1329.474951 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.9305ms (max=1200ms) -
1329.474951 Get Diagnostic Response Positive response was received. -
1329.474951 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
1329.474951 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
9. Check OCC2 value Expected: OCC2 equal expected value: Failed
1329.474951 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 1 -
1329.474951 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 1 fail
fail
10. Wait 10ms: None
1329.484951 1 Waited for 10.000 ms -
11. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1)
11.1. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 1)
11.1.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
1329.484951 Diagnostic request 0x11, 0x01 -
1329.486408 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.45738ms (max=1000ms) -
1329.486408 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
1329.494827 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.4188ms (max=1200ms) -
1329.494827 Get Diagnostic Response Positive response was received. -
1329.494827 Diagnostic response 0x51, 0x01 -
1329.494827 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.1.2. (In for loop)Wait for the diagnostics to start: None
1331.894827 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.1.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
1331.894827 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
1331.896300 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.47284ms (max=1000ms) -
1331.896300 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
1331.913267 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.9665ms (max=1200ms) -
1331.913267 Get Diagnostic Response Positive response was received. -
1331.913267 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
1331.913267 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.1.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
1331.913267 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 1 -
1331.913267 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 1 fail
fail
11.1.5. (In for loop)Wait for FDC10 reached TestPass limit: None
1347.913267 1 Waited for 16.000 s -
11.2. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 2)
11.2.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
1347.913267 Diagnostic request 0x11, 0x01 -
1347.914697 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.43063ms (max=1000ms) -
1347.914697 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
1347.923111 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.41381ms (max=1200ms) -
1347.923111 Get Diagnostic Response Positive response was received. -
1347.923111 Diagnostic response 0x51, 0x01 -
1347.923111 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.2.2. (In for loop)Wait for the diagnostics to start: None
1350.323111 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.2.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
1350.323111 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
1350.324504 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.39295ms (max=1000ms) -
1350.324504 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
1350.341640 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.1365ms (max=1200ms) -
1350.341640 Get Diagnostic Response Positive response was received. -
1350.341640 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
1350.341640 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.2.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
1350.341640 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 2 -
1350.341640 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 2 fail
fail
11.2.5. (In for loop)Wait for FDC10 reached TestPass limit: None
1366.341640 1 Waited for 16.000 s -
11.3. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 3)
11.3.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
1366.341640 Diagnostic request 0x11, 0x01 -
1366.343052 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.41139ms (max=1000ms) -
1366.343052 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
1366.351484 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.43181ms (max=1200ms) -
1366.351484 Get Diagnostic Response Positive response was received. -
1366.351484 Diagnostic response 0x51, 0x01 -
1366.351484 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.3.2. (In for loop)Wait for the diagnostics to start: None
1368.751484 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.3.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
1368.751484 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
1368.753137 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.65362ms (max=1000ms) -
1368.753137 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
1368.769956 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.8185ms (max=1200ms) -
1368.769956 Get Diagnostic Response Positive response was received. -
1368.769956 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
1368.769956 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.3.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
1368.769956 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 3 -
1368.769956 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 3 fail
fail
11.3.5. (In for loop)Wait for FDC10 reached TestPass limit: None
1384.769956 1 Waited for 16.000 s -
11.4. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 4)
11.4.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
1384.769956 Diagnostic request 0x11, 0x01 -
1384.771465 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.50928ms (max=1000ms) -
1384.771465 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
1384.779799 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.3338ms (max=1200ms) -
1384.779799 Get Diagnostic Response Positive response was received. -
1384.779799 Diagnostic response 0x51, 0x01 -
1384.779799 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.4.2. (In for loop)Wait for the diagnostics to start: None
1387.179799 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.4.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
1387.179799 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
1387.181480 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.68145ms (max=1000ms) -
1387.181480 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
1387.198229 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.7485ms (max=1200ms) -
1387.198229 Get Diagnostic Response Positive response was received. -
1387.198229 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
1387.198229 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.4.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
1387.198229 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 4 -
1387.198229 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 4 fail
fail
11.4.5. (In for loop)Wait for FDC10 reached TestPass limit: None
1403.198229 1 Waited for 16.000 s -
11.5. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 5)
11.5.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
1403.198229 Diagnostic request 0x11, 0x01 -
1403.199496 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.26713ms (max=1000ms) -
1403.199496 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
1403.208070 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.57423ms (max=1200ms) -
1403.208070 Get Diagnostic Response Positive response was received. -
1403.208070 Diagnostic response 0x51, 0x01 -
1403.208070 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.5.2. (In for loop)Wait for the diagnostics to start: None
1405.608070 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.5.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
1405.608070 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
1405.609415 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.34441ms (max=1000ms) -
1405.609415 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
1405.626621 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.2065ms (max=1200ms) -
1405.626621 Get Diagnostic Response Positive response was received. -
1405.626621 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
1405.626621 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.5.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
1405.626621 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 5 -
1405.626621 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 5 fail
fail
11.5.5. (In for loop)Wait for FDC10 reached TestPass limit: None
1421.626621 1 Waited for 16.000 s -
11.6. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 6)
11.6.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
1421.626621 Diagnostic request 0x11, 0x01 -
1421.628045 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.42352ms (max=1000ms) -
1421.628045 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
1421.636462 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.41781ms (max=1200ms) -
1421.636462 Get Diagnostic Response Positive response was received. -
1421.636462 Diagnostic response 0x51, 0x01 -
1421.636462 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.6.2. (In for loop)Wait for the diagnostics to start: None
1424.036462 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.6.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
1424.036462 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
1424.037907 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.44466ms (max=1000ms) -
1424.037907 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
1424.055033 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.1265ms (max=1200ms) -
1424.055033 Get Diagnostic Response Positive response was received. -
1424.055033 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
1424.055033 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.6.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
1424.055033 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 6 -
1424.055033 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 6 fail
fail
11.6.5. (In for loop)Wait for FDC10 reached TestPass limit: None
1440.055033 1 Waited for 16.000 s -
11.7. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 7)
11.7.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
1440.055033 Diagnostic request 0x11, 0x01 -
1440.056523 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.48941ms (max=1000ms) -
1440.056523 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
1440.064875 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.35181ms (max=1200ms) -
1440.064875 Get Diagnostic Response Positive response was received. -
1440.064875 Diagnostic response 0x51, 0x01 -
1440.064875 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.7.2. (In for loop)Wait for the diagnostics to start: None
1442.464875 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.7.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
1442.464875 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
1442.466339 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.46445ms (max=1000ms) -
1442.466339 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
1442.483340 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.0005ms (max=1200ms) -
1442.483340 Get Diagnostic Response Positive response was received. -
1442.483340 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
1442.483340 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.7.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
1442.483340 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 7 -
1442.483340 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 7 fail
fail
11.7.5. (In for loop)Wait for FDC10 reached TestPass limit: None
1458.483340 1 Waited for 16.000 s -
11.8. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 8)
11.8.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
1458.483340 Diagnostic request 0x11, 0x01 -
1458.484852 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.51272ms (max=1000ms) -
1458.484852 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
1458.493184 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.33183ms (max=1200ms) -
1458.493184 Get Diagnostic Response Positive response was received. -
1458.493184 Diagnostic response 0x51, 0x01 -
1458.493184 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.8.2. (In for loop)Wait for the diagnostics to start: None
1460.893184 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.8.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
1460.893184 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
1460.894577 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.39331ms (max=1000ms) -
1460.894577 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
1460.911660 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.0825ms (max=1200ms) -
1460.911660 Get Diagnostic Response Positive response was received. -
1460.911660 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
1460.911660 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.8.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
1460.911660 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 8 -
1460.911660 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 8 fail
fail
11.8.5. (In for loop)Wait for FDC10 reached TestPass limit: None
1476.911660 1 Waited for 16.000 s -
11.9. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 9)
11.9.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
1476.911660 Diagnostic request 0x11, 0x01 -
1476.913029 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.36867ms (max=1000ms) -
1476.913029 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
1476.921498 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.4698ms (max=1200ms) -
1476.921498 Get Diagnostic Response Positive response was received. -
1476.921498 Diagnostic response 0x51, 0x01 -
1476.921498 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.9.2. (In for loop)Wait for the diagnostics to start: None
1479.321498 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.9.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
1479.321498 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
1479.322969 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.47108ms (max=1000ms) -
1479.322969 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
1479.339970 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.0005ms (max=1200ms) -
1479.339970 Get Diagnostic Response Positive response was received. -
1479.339970 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
1479.339970 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.9.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
1479.339970 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 9 -
1479.339970 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 9 fail
fail
11.9.5. (In for loop)Wait for FDC10 reached TestPass limit: None
1495.339970 1 Waited for 16.000 s -
11.10. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 10)
11.10.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
1495.339970 Diagnostic request 0x11, 0x01 -
1495.341446 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.4762ms (max=1000ms) -
1495.341446 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
1495.349810 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.3638ms (max=1200ms) -
1495.349810 Get Diagnostic Response Positive response was received. -
1495.349810 Diagnostic response 0x51, 0x01 -
1495.349810 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.10.2. (In for loop)Wait for the diagnostics to start: None
1497.749810 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.10.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
1497.749810 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
1497.751425 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.61542ms (max=1000ms) -
1497.751425 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
1497.768240 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.8145ms (max=1200ms) -
1497.768240 Get Diagnostic Response Positive response was received. -
1497.768240 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
1497.768240 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.10.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
1497.768240 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 10 -
1497.768240 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 10 fail
fail
11.10.5. (In for loop)Wait for FDC10 reached TestPass limit: None
1513.768240 1 Waited for 16.000 s -
11.11. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 11)
11.11.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
1513.768240 Diagnostic request 0x11, 0x01 -
1513.769475 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.23481ms (max=1000ms) -
1513.769475 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
1513.778085 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.6098ms (max=1200ms) -
1513.778085 Get Diagnostic Response Positive response was received. -
1513.778085 Diagnostic response 0x51, 0x01 -
1513.778085 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.11.2. (In for loop)Wait for the diagnostics to start: None
1516.178085 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.11.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
1516.178085 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
1516.179449 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.36489ms (max=1000ms) -
1516.179449 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
1516.196582 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.1325ms (max=1200ms) -
1516.196582 Get Diagnostic Response Positive response was received. -
1516.196582 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
1516.196582 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.11.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
1516.196582 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 11 -
1516.196582 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 11 fail
fail
11.11.5. (In for loop)Wait for FDC10 reached TestPass limit: None
1532.196582 1 Waited for 16.000 s -
11.12. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 12)
11.12.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
1532.196582 Diagnostic request 0x11, 0x01 -
1532.198029 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.44702ms (max=1000ms) -
1532.198029 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
1532.206425 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.39619ms (max=1200ms) -
1532.206425 Get Diagnostic Response Positive response was received. -
1532.206425 Diagnostic response 0x51, 0x01 -
1532.206425 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.12.2. (In for loop)Wait for the diagnostics to start: None
1534.606425 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.12.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
1534.606425 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
1534.608041 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.61547ms (max=1000ms) -
1534.608041 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
1534.624839 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.7985ms (max=1200ms) -
1534.624839 Get Diagnostic Response Positive response was received. -
1534.624839 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
1534.624839 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.12.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
1534.624839 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 12 -
1534.624839 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 12 fail
fail
11.12.5. (In for loop)Wait for FDC10 reached TestPass limit: None
1550.624839 1 Waited for 16.000 s -
11.13. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 13)
11.13.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
1550.624839 Diagnostic request 0x11, 0x01 -
1550.626522 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.68266ms (max=1000ms) -
1550.626522 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
1550.634683 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.1618ms (max=1200ms) -
1550.634683 Get Diagnostic Response Positive response was received. -
1550.634683 Diagnostic response 0x51, 0x01 -
1550.634683 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.13.2. (In for loop)Wait for the diagnostics to start: None
1553.034683 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.13.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
1553.034683 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
1553.036321 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.63734ms (max=1000ms) -
1553.036321 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
1553.053223 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.9025ms (max=1200ms) -
1553.053223 Get Diagnostic Response Positive response was received. -
1553.053223 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
1553.053223 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.13.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
1553.053223 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 13 -
1553.053223 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 13 fail
fail
11.13.5. (In for loop)Wait for FDC10 reached TestPass limit: None
1569.053223 1 Waited for 16.000 s -
11.14. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 14)
11.14.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
1569.053223 Diagnostic request 0x11, 0x01 -
1569.054608 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.38456ms (max=1000ms) -
1569.054608 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
1569.063070 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.4618ms (max=1200ms) -
1569.063070 Get Diagnostic Response Positive response was received. -
1569.063070 Diagnostic response 0x51, 0x01 -
1569.063070 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.14.2. (In for loop)Wait for the diagnostics to start: None
1571.463070 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.14.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
1571.463070 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
1571.464670 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.59992ms (max=1000ms) -
1571.464670 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
1571.481486 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.8165ms (max=1200ms) -
1571.481486 Get Diagnostic Response Positive response was received. -
1571.481486 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
1571.481486 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.14.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
1571.481486 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 14 -
1571.481486 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 14 fail
fail
11.14.5. (In for loop)Wait for FDC10 reached TestPass limit: None
1587.481486 1 Waited for 16.000 s -
11.15. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 15)
11.15.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
1587.481486 Diagnostic request 0x11, 0x01 -
1587.482947 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.46049ms (max=1000ms) -
1587.482947 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
1587.491332 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.38583ms (max=1200ms) -
1587.491332 Get Diagnostic Response Positive response was received. -
1587.491332 Diagnostic response 0x51, 0x01 -
1587.491332 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.15.2. (In for loop)Wait for the diagnostics to start: None
1589.891332 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.15.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
1589.891332 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
1589.892931 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.59833ms (max=1000ms) -
1589.892931 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
1589.909871 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.9405ms (max=1200ms) -
1589.909871 Get Diagnostic Response Positive response was received. -
1589.909871 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
1589.909871 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.15.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
1589.909871 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 15 -
1589.909871 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 15 fail
fail
11.15.5. (In for loop)Wait for FDC10 reached TestPass limit: None
1605.909871 1 Waited for 16.000 s -
11.16. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 16)
11.16.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
1605.909871 Diagnostic request 0x11, 0x01 -
1605.911413 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.54159ms (max=1000ms) -
1605.911413 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
1605.919721 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.30783ms (max=1200ms) -
1605.919721 Get Diagnostic Response Positive response was received. -
1605.919721 Diagnostic response 0x51, 0x01 -
1605.919721 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.16.2. (In for loop)Wait for the diagnostics to start: None
1608.319721 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.16.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
1608.319721 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
1608.321249 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.52795ms (max=1000ms) -
1608.321249 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
1608.338231 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.9825ms (max=1200ms) -
1608.338231 Get Diagnostic Response Positive response was received. -
1608.338231 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
1608.338231 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.16.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
1608.338231 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 16 -
1608.338231 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 16 fail
fail
11.16.5. (In for loop)Wait for FDC10 reached TestPass limit: None
1624.338231 1 Waited for 16.000 s -
11.17. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 17)
11.17.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
1624.338231 Diagnostic request 0x11, 0x01 -
1624.339535 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.30383ms (max=1000ms) -
1624.339535 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
1624.348077 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.54178ms (max=1200ms) -
1624.348077 Get Diagnostic Response Positive response was received. -
1624.348077 Diagnostic response 0x51, 0x01 -
1624.348077 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.17.2. (In for loop)Wait for the diagnostics to start: None
1626.748077 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.17.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
1626.748077 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
1626.749548 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.47097ms (max=1000ms) -
1626.749548 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
1626.766544 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.9965ms (max=1200ms) -
1626.766544 Get Diagnostic Response Positive response was received. -
1626.766544 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
1626.766544 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.17.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
1626.766544 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 17 -
1626.766544 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 17 fail
fail
11.17.5. (In for loop)Wait for FDC10 reached TestPass limit: None
1642.766544 1 Waited for 16.000 s -
11.18. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 18)
11.18.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
1642.766544 Diagnostic request 0x11, 0x01 -
1642.767979 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.43534ms (max=1000ms) -
1642.767979 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
1642.776393 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.41381ms (max=1200ms) -
1642.776393 Get Diagnostic Response Positive response was received. -
1642.776393 Diagnostic response 0x51, 0x01 -
1642.776393 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.18.2. (In for loop)Wait for the diagnostics to start: None
1645.176393 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.18.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
1645.176393 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
1645.177943 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.54951ms (max=1000ms) -
1645.177943 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
1645.194845 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.9025ms (max=1200ms) -
1645.194845 Get Diagnostic Response Positive response was received. -
1645.194845 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
1645.194845 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.18.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
1645.194845 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 18 -
1645.194845 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 18 fail
fail
11.18.5. (In for loop)Wait for FDC10 reached TestPass limit: None
1661.194845 1 Waited for 16.000 s -
11.19. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 19)
11.19.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
1661.194845 Diagnostic request 0x11, 0x01 -
1661.196258 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.4128ms (max=1000ms) -
1661.196258 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
1661.204754 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.49625ms (max=1200ms) -
1661.204754 Get Diagnostic Response Positive response was received. -
1661.204754 Diagnostic response 0x51, 0x01 -
1661.204754 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.19.2. (In for loop)Wait for the diagnostics to start: None
1663.604754 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.19.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
1663.604754 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
1663.606273 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.51845ms (max=1000ms) -
1663.606273 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
1663.623227 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.9545ms (max=1200ms) -
1663.623227 Get Diagnostic Response Positive response was received. -
1663.623227 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
1663.623227 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.19.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
1663.623227 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 19 -
1663.623227 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 19 fail
fail
11.19.5. (In for loop)Wait for FDC10 reached TestPass limit: None
1679.623227 1 Waited for 16.000 s -
11.20. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 20)
11.20.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
1679.623227 Diagnostic request 0x11, 0x01 -
1679.624519 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.29136ms (max=1000ms) -
1679.624519 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
1679.633072 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.55383ms (max=1200ms) -
1679.633072 Get Diagnostic Response Positive response was received. -
1679.633072 Diagnostic response 0x51, 0x01 -
1679.633072 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.20.2. (In for loop)Wait for the diagnostics to start: None
1682.033072 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.20.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
1682.033072 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
1682.034474 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.40191ms (max=1000ms) -
1682.034474 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
1682.051567 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.0925ms (max=1200ms) -
1682.051567 Get Diagnostic Response Positive response was received. -
1682.051567 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
1682.051567 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.20.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
1682.051567 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 20 -
1682.051567 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 20 fail
fail
11.20.5. (In for loop)Wait for FDC10 reached TestPass limit: None
1698.051567 1 Waited for 16.000 s -
11.21. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 21)
11.21.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
1698.051567 Diagnostic request 0x11, 0x01 -
1698.052962 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.3953ms (max=1000ms) -
1698.052962 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
1698.061410 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.4478ms (max=1200ms) -
1698.061410 Get Diagnostic Response Positive response was received. -
1698.061410 Diagnostic response 0x51, 0x01 -
1698.061410 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.21.2. (In for loop)Wait for the diagnostics to start: None
1700.461410 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.21.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
1700.461410 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
1700.463038 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.628ms (max=1000ms) -
1700.463038 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
1700.479836 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.7985ms (max=1200ms) -
1700.479836 Get Diagnostic Response Positive response was received. -
1700.479836 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
1700.479836 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.21.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
1700.479836 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 21 -
1700.479836 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 21 fail
fail
11.21.5. (In for loop)Wait for FDC10 reached TestPass limit: None
1716.479836 1 Waited for 16.000 s -
11.22. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 22)
11.22.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
1716.479836 Diagnostic request 0x11, 0x01 -
1716.481343 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.50664ms (max=1000ms) -
1716.481343 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
1716.489687 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.3438ms (max=1200ms) -
1716.489687 Get Diagnostic Response Positive response was received. -
1716.489687 Diagnostic response 0x51, 0x01 -
1716.489687 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.22.2. (In for loop)Wait for the diagnostics to start: None
1718.889687 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.22.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
1718.889687 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
1718.891180 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.49361ms (max=1000ms) -
1718.891180 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
1718.908099 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.9185ms (max=1200ms) -
1718.908099 Get Diagnostic Response Positive response was received. -
1718.908099 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
1718.908099 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.22.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
1718.908099 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 22 -
1718.908099 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 22 fail
fail
11.22.5. (In for loop)Wait for FDC10 reached TestPass limit: None
1734.908099 1 Waited for 16.000 s -
11.23. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 23)
11.23.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
1734.908099 Diagnostic request 0x11, 0x01 -
1734.909435 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.3358ms (max=1000ms) -
1734.909435 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
1734.917947 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.51181ms (max=1200ms) -
1734.917947 Get Diagnostic Response Positive response was received. -
1734.917947 Diagnostic response 0x51, 0x01 -
1734.917947 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.23.2. (In for loop)Wait for the diagnostics to start: None
1737.317947 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.23.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
1737.317947 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
1737.319420 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.47397ms (max=1000ms) -
1737.319420 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
1737.336423 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.0025ms (max=1200ms) -
1737.336423 Get Diagnostic Response Positive response was received. -
1737.336423 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
1737.336423 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.23.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
1737.336423 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 23 -
1737.336423 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 23 fail
fail
11.23.5. (In for loop)Wait for FDC10 reached TestPass limit: None
1753.336423 1 Waited for 16.000 s -
11.24. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 24)
11.24.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
1753.336423 Diagnostic request 0x11, 0x01 -
1753.337940 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.51684ms (max=1000ms) -
1753.337940 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
1753.346274 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.33381ms (max=1200ms) -
1753.346274 Get Diagnostic Response Positive response was received. -
1753.346274 Diagnostic response 0x51, 0x01 -
1753.346274 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.24.2. (In for loop)Wait for the diagnostics to start: None
1755.746274 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.24.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
1755.746274 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
1755.747793 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.51955ms (max=1000ms) -
1755.747793 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
1755.764824 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.0305ms (max=1200ms) -
1755.764824 Get Diagnostic Response Positive response was received. -
1755.764824 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
1755.764824 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.24.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
1755.764824 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 24 -
1755.764824 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 24 fail
fail
11.24.5. (In for loop)Wait for FDC10 reached TestPass limit: None
1771.764824 1 Waited for 16.000 s -
11.25. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 25)
11.25.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
1771.764824 Diagnostic request 0x11, 0x01 -
1771.766409 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.58552ms (max=1000ms) -
1771.766409 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
1771.774669 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.2598ms (max=1200ms) -
1771.774669 Get Diagnostic Response Positive response was received. -
1771.774669 Diagnostic response 0x51, 0x01 -
1771.774669 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.25.2. (In for loop)Wait for the diagnostics to start: None
1774.174669 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.25.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
1774.174669 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
1774.176211 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.54216ms (max=1000ms) -
1774.176211 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
1774.193132 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.9205ms (max=1200ms) -
1774.193132 Get Diagnostic Response Positive response was received. -
1774.193132 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
1774.193132 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.25.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
1774.193132 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 25 -
1774.193132 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 25 fail
fail
11.25.5. (In for loop)Wait for FDC10 reached TestPass limit: None
1790.193132 1 Waited for 16.000 s -
11.26. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 26)
11.26.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
1790.193132 Diagnostic request 0x11, 0x01 -
1790.194429 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.29745ms (max=1000ms) -
1790.194429 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
1790.203041 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.61225ms (max=1200ms) -
1790.203041 Get Diagnostic Response Positive response was received. -
1790.203041 Diagnostic response 0x51, 0x01 -
1790.203041 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.26.2. (In for loop)Wait for the diagnostics to start: None
1792.603041 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.26.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
1792.603041 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
1792.604509 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.46769ms (max=1000ms) -
1792.604509 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
1792.621425 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.9165ms (max=1200ms) -
1792.621425 Get Diagnostic Response Positive response was received. -
1792.621425 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
1792.621425 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.26.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
1792.621425 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 26 -
1792.621425 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 26 fail
fail
11.26.5. (In for loop)Wait for FDC10 reached TestPass limit: None
1808.621425 1 Waited for 16.000 s -
11.27. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 27)
11.27.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
1808.621425 Diagnostic request 0x11, 0x01 -
1808.622868 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.44266ms (max=1000ms) -
1808.622868 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
1808.631272 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.40381ms (max=1200ms) -
1808.631272 Get Diagnostic Response Positive response was received. -
1808.631272 Diagnostic response 0x51, 0x01 -
1808.631272 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.27.2. (In for loop)Wait for the diagnostics to start: None
1811.031272 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.27.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
1811.031272 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
1811.032776 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.50364ms (max=1000ms) -
1811.032776 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
1811.049740 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.9645ms (max=1200ms) -
1811.049740 Get Diagnostic Response Positive response was received. -
1811.049740 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
1811.049740 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.27.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
1811.049740 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 27 -
1811.049740 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 27 fail
fail
11.27.5. (In for loop)Wait for FDC10 reached TestPass limit: None
1827.049740 1 Waited for 16.000 s -
11.28. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 28)
11.28.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
1827.049740 Diagnostic request 0x11, 0x01 -
1827.051190 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.44972ms (max=1000ms) -
1827.051190 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
1827.059586 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.39581ms (max=1200ms) -
1827.059586 Get Diagnostic Response Positive response was received. -
1827.059586 Diagnostic response 0x51, 0x01 -
1827.059586 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.28.2. (In for loop)Wait for the diagnostics to start: None
1829.459586 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.28.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
1829.459586 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
1829.461158 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.57272ms (max=1000ms) -
1829.461158 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
1829.478025 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.8665ms (max=1200ms) -
1829.478025 Get Diagnostic Response Positive response was received. -
1829.478025 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
1829.478025 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.28.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
1829.478025 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 28 -
1829.478025 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 28 fail
fail
11.28.5. (In for loop)Wait for FDC10 reached TestPass limit: None
1845.478025 1 Waited for 16.000 s -
11.29. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 29)
11.29.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
1845.478025 Diagnostic request 0x11, 0x01 -
1845.479441 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.41603ms (max=1000ms) -
1845.479441 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
1845.487875 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.4338ms (max=1200ms) -
1845.487875 Get Diagnostic Response Positive response was received. -
1845.487875 Diagnostic response 0x51, 0x01 -
1845.487875 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.29.2. (In for loop)Wait for the diagnostics to start: None
1847.887875 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.29.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
1847.887875 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
1847.889431 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.55666ms (max=1000ms) -
1847.889431 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
1847.906206 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.7745ms (max=1200ms) -
1847.906206 Get Diagnostic Response Positive response was received. -
1847.906206 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
1847.906206 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.29.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
1847.906206 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 29 -
1847.906206 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 29 fail
fail
11.29.5. (In for loop)Wait for FDC10 reached TestPass limit: None
1863.906206 1 Waited for 16.000 s -
11.30. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 30)
11.30.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
1863.906206 Diagnostic request 0x11, 0x01 -
1863.907534 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.32842ms (max=1000ms) -
1863.907534 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
1863.916060 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.5258ms (max=1200ms) -
1863.916060 Get Diagnostic Response Positive response was received. -
1863.916060 Diagnostic response 0x51, 0x01 -
1863.916060 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.30.2. (In for loop)Wait for the diagnostics to start: None
1866.316060 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.30.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
1866.316060 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
1866.317543 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.48295ms (max=1000ms) -
1866.317543 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
1866.334549 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.0065ms (max=1200ms) -
1866.334549 Get Diagnostic Response Positive response was received. -
1866.334549 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
1866.334549 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.30.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
1866.334549 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 30 -
1866.334549 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 30 fail
fail
11.30.5. (In for loop)Wait for FDC10 reached TestPass limit: None
1882.334549 1 Waited for 16.000 s -
11.31. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 31)
11.31.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
1882.334549 Diagnostic request 0x11, 0x01 -
1882.335977 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.42717ms (max=1000ms) -
1882.335977 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
1882.344394 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.41781ms (max=1200ms) -
1882.344394 Get Diagnostic Response Positive response was received. -
1882.344394 Diagnostic response 0x51, 0x01 -
1882.344394 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.31.2. (In for loop)Wait for the diagnostics to start: None
1884.744394 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.31.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
1884.744394 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
1884.745916 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.5217ms (max=1000ms) -
1884.745916 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
1884.762913 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.9965ms (max=1200ms) -
1884.762913 Get Diagnostic Response Positive response was received. -
1884.762913 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
1884.762913 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.31.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
1884.762913 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 31 -
1884.762913 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 31 fail
fail
11.31.5. (In for loop)Wait for FDC10 reached TestPass limit: None
1900.762913 1 Waited for 16.000 s -
11.32. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 32)
11.32.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
1900.762913 Diagnostic request 0x11, 0x01 -
1900.764297 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.38411ms (max=1000ms) -
1900.764297 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
1900.772756 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.4598ms (max=1200ms) -
1900.772756 Get Diagnostic Response Positive response was received. -
1900.772756 Diagnostic response 0x51, 0x01 -
1900.772756 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.32.2. (In for loop)Wait for the diagnostics to start: None
1903.172756 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.32.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
1903.172756 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
1903.174239 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.48286ms (max=1000ms) -
1903.174239 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
1903.191278 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.0385ms (max=1200ms) -
1903.191278 Get Diagnostic Response Positive response was received. -
1903.191278 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
1903.191278 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.32.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
1903.191278 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 32 -
1903.191278 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 32 fail
fail
11.32.5. (In for loop)Wait for FDC10 reached TestPass limit: None
1919.191278 1 Waited for 16.000 s -
11.33. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 33)
11.33.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
1919.191278 Diagnostic request 0x11, 0x01 -
1919.192810 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.53264ms (max=1000ms) -
1919.192810 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
1919.201127 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.31628ms (max=1200ms) -
1919.201127 Get Diagnostic Response Positive response was received. -
1919.201127 Diagnostic response 0x51, 0x01 -
1919.201127 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.33.2. (In for loop)Wait for the diagnostics to start: None
1921.601127 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.33.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
1921.601127 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
1921.602508 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.38102ms (max=1000ms) -
1921.602508 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
1921.619616 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.1085ms (max=1200ms) -
1921.619616 Get Diagnostic Response Positive response was received. -
1921.619616 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
1921.619616 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.33.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
1921.619616 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 33 -
1921.619616 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 33 fail
fail
11.33.5. (In for loop)Wait for FDC10 reached TestPass limit: None
1937.619616 1 Waited for 16.000 s -
11.34. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 34)
11.34.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
1937.619616 Diagnostic request 0x11, 0x01 -
1937.621122 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.50567ms (max=1000ms) -
1937.621122 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
1937.629466 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.3438ms (max=1200ms) -
1937.629466 Get Diagnostic Response Positive response was received. -
1937.629466 Diagnostic response 0x51, 0x01 -
1937.629466 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.34.2. (In for loop)Wait for the diagnostics to start: None
1940.029466 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.34.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
1940.029466 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
1940.031024 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.55824ms (max=1000ms) -
1940.031024 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
1940.047924 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.9005ms (max=1200ms) -
1940.047924 Get Diagnostic Response Positive response was received. -
1940.047924 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
1940.047924 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.34.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
1940.047924 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 34 -
1940.047924 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 34 fail
fail
11.34.5. (In for loop)Wait for FDC10 reached TestPass limit: None
1956.047924 1 Waited for 16.000 s -
11.35. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 35)
11.35.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
1956.047924 Diagnostic request 0x11, 0x01 -
1956.049485 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.56036ms (max=1000ms) -
1956.049485 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
1956.057767 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.28183ms (max=1200ms) -
1956.057767 Get Diagnostic Response Positive response was received. -
1956.057767 Diagnostic response 0x51, 0x01 -
1956.057767 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.35.2. (In for loop)Wait for the diagnostics to start: None
1958.457767 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.35.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
1958.457767 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
1958.459262 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.49519ms (max=1000ms) -
1958.459262 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
1958.476328 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.0665ms (max=1200ms) -
1958.476328 Get Diagnostic Response Positive response was received. -
1958.476328 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
1958.476328 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.35.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
1958.476328 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 35 -
1958.476328 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 35 fail
fail
11.35.5. (In for loop)Wait for FDC10 reached TestPass limit: None
1974.476328 1 Waited for 16.000 s -
11.36. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 36)
11.36.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
1974.476328 Diagnostic request 0x11, 0x01 -
1974.477753 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.42459ms (max=1000ms) -
1974.477753 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
1974.486173 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.4198ms (max=1200ms) -
1974.486173 Get Diagnostic Response Positive response was received. -
1974.486173 Diagnostic response 0x51, 0x01 -
1974.486173 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.36.2. (In for loop)Wait for the diagnostics to start: None
1976.886173 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.36.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
1976.886173 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
1976.887535 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.36253ms (max=1000ms) -
1976.887535 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
1976.904656 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.1205ms (max=1200ms) -
1976.904656 Get Diagnostic Response Positive response was received. -
1976.904656 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
1976.904656 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.36.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
1976.904656 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 36 -
1976.904656 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 36 fail
fail
11.36.5. (In for loop)Wait for FDC10 reached TestPass limit: None
1992.904656 1 Waited for 16.000 s -
11.37. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 37)
11.37.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
1992.904656 Diagnostic request 0x11, 0x01 -
1992.906028 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.37266ms (max=1000ms) -
1992.906028 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
1992.914506 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.4778ms (max=1200ms) -
1992.914506 Get Diagnostic Response Positive response was received. -
1992.914506 Diagnostic response 0x51, 0x01 -
1992.914506 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.37.2. (In for loop)Wait for the diagnostics to start: None
1995.314506 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.37.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
1995.314506 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
1995.315977 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.47131ms (max=1000ms) -
1995.315977 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
1995.332978 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.0005ms (max=1200ms) -
1995.332978 Get Diagnostic Response Positive response was received. -
1995.332978 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
1995.332978 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.37.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
1995.332978 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 37 -
1995.332978 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 37 fail
fail
11.37.5. (In for loop)Wait for FDC10 reached TestPass limit: None
2011.332978 1 Waited for 16.000 s -
11.38. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 38)
11.38.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
2011.332978 Diagnostic request 0x11, 0x01 -
2011.334425 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.44675ms (max=1000ms) -
2011.334425 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
2011.342826 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.4018ms (max=1200ms) -
2011.342826 Get Diagnostic Response Positive response was received. -
2011.342826 Diagnostic response 0x51, 0x01 -
2011.342826 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.38.2. (In for loop)Wait for the diagnostics to start: None
2013.742826 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.38.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
2013.742826 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
2013.744288 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.46202ms (max=1000ms) -
2013.744288 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
2013.761273 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.9845ms (max=1200ms) -
2013.761273 Get Diagnostic Response Positive response was received. -
2013.761273 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
2013.761273 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.38.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
2013.761273 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 38 -
2013.761273 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 38 fail
fail
11.38.5. (In for loop)Wait for FDC10 reached TestPass limit: None
2029.761273 1 Waited for 16.000 s -
11.39. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 39)
11.39.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
2029.761273 Diagnostic request 0x11, 0x01 -
2029.762696 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.42267ms (max=1000ms) -
2029.762696 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
2029.771119 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.4238ms (max=1200ms) -
2029.771119 Get Diagnostic Response Positive response was received. -
2029.771119 Diagnostic response 0x51, 0x01 -
2029.771119 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.39.2. (In for loop)Wait for the diagnostics to start: None
2032.171119 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.39.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
2032.171119 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
2032.172503 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.38398ms (max=1000ms) -
2032.172503 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
2032.189598 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.0945ms (max=1200ms) -
2032.189598 Get Diagnostic Response Positive response was received. -
2032.189598 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
2032.189598 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.39.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
2032.189598 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 39 -
2032.189598 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 39 fail
fail
11.39.5. (In for loop)Wait for FDC10 reached TestPass limit: None
2048.189598 1 Waited for 16.000 s -
11.40. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 40)
11.40.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
2048.189598 Diagnostic request 0x11, 0x01 -
2048.191095 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.49713ms (max=1000ms) -
2048.191095 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
2048.199447 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.3518ms (max=1200ms) -
2048.199447 Get Diagnostic Response Positive response was received. -
2048.199447 Diagnostic response 0x51, 0x01 -
2048.199447 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.40.2. (In for loop)Wait for the diagnostics to start: None
2050.599447 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.40.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
2050.599447 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
2050.601456 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=2.00891ms (max=1000ms) -
2050.601456 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
2050.618078 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.6225ms (max=1200ms) -
2050.618078 Get Diagnostic Response Positive response was received. -
2050.618078 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
2050.618078 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.40.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
2050.618078 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 40 -
2050.618078 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 40 fail
fail
11.40.5. (In for loop)Wait for FDC10 reached TestPass limit: None
2066.618078 1 Waited for 16.000 s -
11.41. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 41)
11.41.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
2066.618078 Diagnostic request 0x11, 0x01 -
2066.619440 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.36202ms (max=1000ms) -
2066.619440 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
2066.627926 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.4858ms (max=1200ms) -
2066.627926 Get Diagnostic Response Positive response was received. -
2066.627926 Diagnostic response 0x51, 0x01 -
2066.627926 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.41.2. (In for loop)Wait for the diagnostics to start: None
2069.027926 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.41.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
2069.027926 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
2069.029450 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.52447ms (max=1000ms) -
2069.029450 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
2069.046327 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.8765ms (max=1200ms) -
2069.046327 Get Diagnostic Response Positive response was received. -
2069.046327 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
2069.046327 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.41.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
2069.046327 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 41 -
2069.046327 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 41 fail
fail
11.41.5. (In for loop)Wait for FDC10 reached TestPass limit: None
2085.046327 1 Waited for 16.000 s -
11.42. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 42)
11.42.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
2085.046327 Diagnostic request 0x11, 0x01 -
2085.047761 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.43461ms (max=1000ms) -
2085.047761 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
2085.056175 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.4138ms (max=1200ms) -
2085.056175 Get Diagnostic Response Positive response was received. -
2085.056175 Diagnostic response 0x51, 0x01 -
2085.056175 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.42.2. (In for loop)Wait for the diagnostics to start: None
2087.456175 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.42.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
2087.456175 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
2087.457555 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.37992ms (max=1000ms) -
2087.457555 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
2087.474666 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.1105ms (max=1200ms) -
2087.474666 Get Diagnostic Response Positive response was received. -
2087.474666 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
2087.474666 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.42.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
2087.474666 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 42 -
2087.474666 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 42 fail
fail
11.42.5. (In for loop)Wait for FDC10 reached TestPass limit: None
2103.474666 1 Waited for 16.000 s -
11.43. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 43)
11.43.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
2103.474666 Diagnostic request 0x11, 0x01 -
2103.476150 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.48398ms (max=1000ms) -
2103.476150 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
2103.484511 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.3618ms (max=1200ms) -
2103.484511 Get Diagnostic Response Positive response was received. -
2103.484511 Diagnostic response 0x51, 0x01 -
2103.484511 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.43.2. (In for loop)Wait for the diagnostics to start: None
2105.884511 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.43.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
2105.884511 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
2105.885978 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.4667ms (max=1000ms) -
2105.885978 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
2105.903021 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.0425ms (max=1200ms) -
2105.903021 Get Diagnostic Response Positive response was received. -
2105.903021 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
2105.903021 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.43.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
2105.903021 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 43 -
2105.903021 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 43 fail
fail
11.43.5. (In for loop)Wait for FDC10 reached TestPass limit: None
2121.903021 1 Waited for 16.000 s -
11.44. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 44)
11.44.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
2121.903021 Diagnostic request 0x11, 0x01 -
2121.904426 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.40586ms (max=1000ms) -
2121.904426 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
2121.912866 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.4398ms (max=1200ms) -
2121.912866 Get Diagnostic Response Positive response was received. -
2121.912866 Diagnostic response 0x51, 0x01 -
2121.912866 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.44.2. (In for loop)Wait for the diagnostics to start: None
2124.312866 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.44.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
2124.312866 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
2124.314315 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.44833ms (max=1000ms) -
2124.314315 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
2124.331377 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.0625ms (max=1200ms) -
2124.331377 Get Diagnostic Response Positive response was received. -
2124.331377 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
2124.331377 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.44.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
2124.331377 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 44 -
2124.331377 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 44 fail
fail
11.44.5. (In for loop)Wait for FDC10 reached TestPass limit: None
2140.331377 1 Waited for 16.000 s -
11.45. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 45)
11.45.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
2140.331377 Diagnostic request 0x11, 0x01 -
2140.332932 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.55527ms (max=1000ms) -
2140.332932 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
2140.341222 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.2898ms (max=1200ms) -
2140.341222 Get Diagnostic Response Positive response was received. -
2140.341222 Diagnostic response 0x51, 0x01 -
2140.341222 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.45.2. (In for loop)Wait for the diagnostics to start: None
2142.741222 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.45.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
2142.741222 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
2142.742586 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.36361ms (max=1000ms) -
2142.742586 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
2142.759708 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.1225ms (max=1200ms) -
2142.759708 Get Diagnostic Response Positive response was received. -
2142.759708 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
2142.759708 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.45.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
2142.759708 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 45 -
2142.759708 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 45 fail
fail
11.45.5. (In for loop)Wait for FDC10 reached TestPass limit: None
2158.759708 1 Waited for 16.000 s -
11.46. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 46)
11.46.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
2158.759708 Diagnostic request 0x11, 0x01 -
2158.761179 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.47055ms (max=1000ms) -
2158.761179 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
2158.769557 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.37781ms (max=1200ms) -
2158.769557 Get Diagnostic Response Positive response was received. -
2158.769557 Diagnostic response 0x51, 0x01 -
2158.769557 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.46.2. (In for loop)Wait for the diagnostics to start: None
2161.169557 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.46.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
2161.169557 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
2161.171159 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.60224ms (max=1000ms) -
2161.171159 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
2161.188023 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.8645ms (max=1200ms) -
2161.188023 Get Diagnostic Response Positive response was received. -
2161.188023 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
2161.188023 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.46.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
2161.188023 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 46 -
2161.188023 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 46 fail
fail
11.46.5. (In for loop)Wait for FDC10 reached TestPass limit: None
2177.188023 1 Waited for 16.000 s -
11.47. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 47)
11.47.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
2177.188023 Diagnostic request 0x11, 0x01 -
2177.189397 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.37333ms (max=1000ms) -
2177.189397 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
2177.197872 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.4758ms (max=1200ms) -
2177.197872 Get Diagnostic Response Positive response was received. -
2177.197872 Diagnostic response 0x51, 0x01 -
2177.197872 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.47.2. (In for loop)Wait for the diagnostics to start: None
2179.597872 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.47.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
2179.597872 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
2179.599341 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.46892ms (max=1000ms) -
2179.599341 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
2179.616336 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.9949ms (max=1200ms) -
2179.616336 Get Diagnostic Response Positive response was received. -
2179.616336 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
2179.616336 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.47.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
2179.616336 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 47 -
2179.616336 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 47 fail
fail
11.47.5. (In for loop)Wait for FDC10 reached TestPass limit: None
2195.616336 1 Waited for 16.000 s -
11.48. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 48)
11.48.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
2195.616336 Diagnostic request 0x11, 0x01 -
2195.617906 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.57016ms (max=1000ms) -
2195.617906 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
2195.626174 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.26781ms (max=1200ms) -
2195.626174 Get Diagnostic Response Positive response was received. -
2195.626174 Diagnostic response 0x51, 0x01 -
2195.626174 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.48.2. (In for loop)Wait for the diagnostics to start: None
2198.026174 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.48.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
2198.026174 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
2198.027569 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.39503ms (max=1000ms) -
2198.027569 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
2198.044674 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.1045ms (max=1200ms) -
2198.044674 Get Diagnostic Response Positive response was received. -
2198.044674 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
2198.044674 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.48.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
2198.044674 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 48 -
2198.044674 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 48 fail
fail
11.48.5. (In for loop)Wait for FDC10 reached TestPass limit: None
2214.044674 1 Waited for 16.000 s -
11.49. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 49)
11.49.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
2214.044674 Diagnostic request 0x11, 0x01 -
2214.046158 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.48483ms (max=1000ms) -
2214.046158 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
2214.054514 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.35583ms (max=1200ms) -
2214.054514 Get Diagnostic Response Positive response was received. -
2214.054514 Diagnostic response 0x51, 0x01 -
2214.054514 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.49.2. (In for loop)Wait for the diagnostics to start: None
2216.454514 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.49.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
2216.454514 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
2216.456008 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.49366ms (max=1000ms) -
2216.456008 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
2216.473066 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.0585ms (max=1200ms) -
2216.473066 Get Diagnostic Response Positive response was received. -
2216.473066 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
2216.473066 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.49.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
2216.473066 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 49 -
2216.473066 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 49 fail
fail
11.49.5. (In for loop)Wait for FDC10 reached TestPass limit: None
2232.473066 1 Waited for 16.000 s -
11.50. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 50)
11.50.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
2232.473066 Diagnostic request 0x11, 0x01 -
2232.474523 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.45611ms (max=1000ms) -
2232.474523 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
2232.482916 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.3938ms (max=1200ms) -
2232.482916 Get Diagnostic Response Positive response was received. -
2232.482916 Diagnostic response 0x51, 0x01 -
2232.482916 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.50.2. (In for loop)Wait for the diagnostics to start: None
2234.882916 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.50.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
2234.882916 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
2234.884291 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.37451ms (max=1000ms) -
2234.884291 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
2234.901429 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.1385ms (max=1200ms) -
2234.901429 Get Diagnostic Response Positive response was received. -
2234.901429 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
2234.901429 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.50.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
2234.901429 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 50 -
2234.901429 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 50 fail
fail
11.50.5. (In for loop)Wait for FDC10 reached TestPass limit: None
2250.901429 1 Waited for 16.000 s -
11.51. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 51)
11.51.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
2250.901429 Diagnostic request 0x11, 0x01 -
2250.902997 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.5678ms (max=1000ms) -
2250.902997 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
2250.911277 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.27981ms (max=1200ms) -
2250.911277 Get Diagnostic Response Positive response was received. -
2250.911277 Diagnostic response 0x51, 0x01 -
2250.911277 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.51.2. (In for loop)Wait for the diagnostics to start: None
2253.311277 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.51.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
2253.311277 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
2253.312868 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.59111ms (max=1000ms) -
2253.312868 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
2253.329796 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.9285ms (max=1200ms) -
2253.329796 Get Diagnostic Response Positive response was received. -
2253.329796 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
2253.329796 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.51.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
2253.329796 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 51 -
2253.329796 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 51 fail
fail
11.51.5. (In for loop)Wait for FDC10 reached TestPass limit: None
2269.329796 1 Waited for 16.000 s -
11.52. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 52)
11.52.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
2269.329796 Diagnostic request 0x11, 0x01 -
2269.331238 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.44119ms (max=1000ms) -
2269.331238 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
2269.339651 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.41381ms (max=1200ms) -
2269.339651 Get Diagnostic Response Positive response was received. -
2269.339651 Diagnostic response 0x51, 0x01 -
2269.339651 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.52.2. (In for loop)Wait for the diagnostics to start: None
2271.739651 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.52.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
2271.739651 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
2271.741219 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.56725ms (max=1000ms) -
2271.741219 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
2271.758247 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.0285ms (max=1200ms) -
2271.758247 Get Diagnostic Response Positive response was received. -
2271.758247 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
2271.758247 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.52.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
2271.758247 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 52 -
2271.758247 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 52 fail
fail
11.52.5. (In for loop)Wait for FDC10 reached TestPass limit: None
2287.758247 1 Waited for 16.000 s -
11.53. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 53)
11.53.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
2287.758247 Diagnostic request 0x11, 0x01 -
2287.759809 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.56223ms (max=1000ms) -
2287.759809 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
2287.768097 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.2878ms (max=1200ms) -
2287.768097 Get Diagnostic Response Positive response was received. -
2287.768097 Diagnostic response 0x51, 0x01 -
2287.768097 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.53.2. (In for loop)Wait for the diagnostics to start: None
2290.168097 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.53.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
2290.168097 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
2290.169466 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.36845ms (max=1000ms) -
2290.169466 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
2290.186568 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.1025ms (max=1200ms) -
2290.186568 Get Diagnostic Response Positive response was received. -
2290.186568 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
2290.186568 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.53.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
2290.186568 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 53 -
2290.186568 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 53 fail
fail
11.53.5. (In for loop)Wait for FDC10 reached TestPass limit: None
2306.186568 1 Waited for 16.000 s -
11.54. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 54)
11.54.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
2306.186568 Diagnostic request 0x11, 0x01 -
2306.187930 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.36141ms (max=1000ms) -
2306.187930 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
2306.196419 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.48981ms (max=1200ms) -
2306.196419 Get Diagnostic Response Positive response was received. -
2306.196419 Diagnostic response 0x51, 0x01 -
2306.196419 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.54.2. (In for loop)Wait for the diagnostics to start: None
2308.596419 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.54.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
2308.596419 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
2308.597898 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.47861ms (max=1000ms) -
2308.597898 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
2308.614917 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.0189ms (max=1200ms) -
2308.614917 Get Diagnostic Response Positive response was received. -
2308.614917 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
2308.614917 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.54.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
2308.614917 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 54 -
2308.614917 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 54 fail
fail
11.54.5. (In for loop)Wait for FDC10 reached TestPass limit: None
2324.614917 1 Waited for 16.000 s -
11.55. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 55)
11.55.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
2324.614917 Diagnostic request 0x11, 0x01 -
2324.616395 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.47819ms (max=1000ms) -
2324.616395 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
2324.624773 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.37784ms (max=1200ms) -
2324.624773 Get Diagnostic Response Positive response was received. -
2324.624773 Diagnostic response 0x51, 0x01 -
2324.624773 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.55.2. (In for loop)Wait for the diagnostics to start: None
2327.024773 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.55.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
2327.024773 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
2327.026368 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.59548ms (max=1000ms) -
2327.026368 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
2327.043341 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.9725ms (max=1200ms) -
2327.043341 Get Diagnostic Response Positive response was received. -
2327.043341 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
2327.043341 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.55.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
2327.043341 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 55 -
2327.043341 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 55 fail
fail
11.55.5. (In for loop)Wait for FDC10 reached TestPass limit: None
2343.043341 1 Waited for 16.000 s -
11.56. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 56)
11.56.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
2343.043341 Diagnostic request 0x11, 0x01 -
2343.044896 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.55541ms (max=1000ms) -
2343.044896 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
2343.053192 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.2958ms (max=1200ms) -
2343.053192 Get Diagnostic Response Positive response was received. -
2343.053192 Diagnostic response 0x51, 0x01 -
2343.053192 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.56.2. (In for loop)Wait for the diagnostics to start: None
2345.453192 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.56.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
2345.453192 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
2345.454510 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.31781ms (max=1000ms) -
2345.454510 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
2345.471612 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.1025ms (max=1200ms) -
2345.471612 Get Diagnostic Response Positive response was received. -
2345.471612 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
2345.471612 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.56.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
2345.471612 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 56 -
2345.471612 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 56 fail
fail
11.56.5. (In for loop)Wait for FDC10 reached TestPass limit: None
2361.471612 1 Waited for 16.000 s -
11.57. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 57)
11.57.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
2361.471612 Diagnostic request 0x11, 0x01 -
2361.473032 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.41969ms (max=1000ms) -
2361.473032 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
2361.481464 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.4318ms (max=1200ms) -
2361.481464 Get Diagnostic Response Positive response was received. -
2361.481464 Diagnostic response 0x51, 0x01 -
2361.481464 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.57.2. (In for loop)Wait for the diagnostics to start: None
2363.881464 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.57.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
2363.881464 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
2363.882962 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.49856ms (max=1000ms) -
2363.882962 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
2363.899957 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.9945ms (max=1200ms) -
2363.899957 Get Diagnostic Response Positive response was received. -
2363.899957 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
2363.899957 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.57.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
2363.899957 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 57 -
2363.899957 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 57 fail
fail
11.57.5. (In for loop)Wait for FDC10 reached TestPass limit: None
2379.899957 1 Waited for 16.000 s -
11.58. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 58)
11.58.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
2379.899957 Diagnostic request 0x11, 0x01 -
2379.901398 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.44081ms (max=1000ms) -
2379.901398 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
2379.909810 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.4118ms (max=1200ms) -
2379.909810 Get Diagnostic Response Positive response was received. -
2379.909810 Diagnostic response 0x51, 0x01 -
2379.909810 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.58.2. (In for loop)Wait for the diagnostics to start: None
2382.309810 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.58.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
2382.309810 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
2382.311368 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.55842ms (max=1000ms) -
2382.311368 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
2382.328430 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.0625ms (max=1200ms) -
2382.328430 Get Diagnostic Response Positive response was received. -
2382.328430 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
2382.328430 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.58.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
2382.328430 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 58 -
2382.328430 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 58 fail
fail
11.58.5. (In for loop)Wait for FDC10 reached TestPass limit: None
2398.328430 1 Waited for 16.000 s -
11.59. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 59)
11.59.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
2398.328430 Diagnostic request 0x11, 0x01 -
2398.329837 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.4068ms (max=1000ms) -
2398.329837 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
2398.338281 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.44381ms (max=1200ms) -
2398.338281 Get Diagnostic Response Positive response was received. -
2398.338281 Diagnostic response 0x51, 0x01 -
2398.338281 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.59.2. (In for loop)Wait for the diagnostics to start: None
2400.738281 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.59.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
2400.738281 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
2400.739785 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.50436ms (max=1000ms) -
2400.739785 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
2400.756790 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.0045ms (max=1200ms) -
2400.756790 Get Diagnostic Response Positive response was received. -
2400.756790 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
2400.756790 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.59.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
2400.756790 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 59 -
2400.756790 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 59 fail
fail
11.59.5. (In for loop)Wait for FDC10 reached TestPass limit: None
2416.756790 1 Waited for 16.000 s -
11.60. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 60)
11.60.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
2416.756790 Diagnostic request 0x11, 0x01 -
2416.758205 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.41491ms (max=1000ms) -
2416.758205 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
2416.766641 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.43581ms (max=1200ms) -
2416.766641 Get Diagnostic Response Positive response was received. -
2416.766641 Diagnostic response 0x51, 0x01 -
2416.766641 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.60.2. (In for loop)Wait for the diagnostics to start: None
2419.166641 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.60.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
2419.166641 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
2419.168100 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.45988ms (max=1000ms) -
2419.168100 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
2419.185159 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.0585ms (max=1200ms) -
2419.185159 Get Diagnostic Response Positive response was received. -
2419.185159 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
2419.185159 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.60.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
2419.185159 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 60 -
2419.185159 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 60 fail
fail
11.60.5. (In for loop)Wait for FDC10 reached TestPass limit: None
2435.185159 1 Waited for 16.000 s -
11.61. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 61)
11.61.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
2435.185159 Diagnostic request 0x11, 0x01 -
2435.186525 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.36572ms (max=1000ms) -
2435.186525 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
2435.195010 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.48581ms (max=1200ms) -
2435.195010 Get Diagnostic Response Positive response was received. -
2435.195010 Diagnostic response 0x51, 0x01 -
2435.195010 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.61.2. (In for loop)Wait for the diagnostics to start: None
2437.595010 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.61.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
2437.595010 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
2437.596416 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.40542ms (max=1000ms) -
2437.596416 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
2437.613473 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.0569ms (max=1200ms) -
2437.613473 Get Diagnostic Response Positive response was received. -
2437.613473 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
2437.613473 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.61.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
2437.613473 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 61 -
2437.613473 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 61 fail
fail
11.61.5. (In for loop)Wait for FDC10 reached TestPass limit: None
2453.613473 1 Waited for 16.000 s -
11.62. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 62)
11.62.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
2453.613473 Diagnostic request 0x11, 0x01 -
2453.615076 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.60363ms (max=1000ms) -
2453.615076 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
2453.623320 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.24381ms (max=1200ms) -
2453.623320 Get Diagnostic Response Positive response was received. -
2453.623320 Diagnostic response 0x51, 0x01 -
2453.623320 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.62.2. (In for loop)Wait for the diagnostics to start: None
2456.023320 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.62.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
2456.023320 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
2456.024807 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.48658ms (max=1000ms) -
2456.024807 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
2456.041751 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.9445ms (max=1200ms) -
2456.041751 Get Diagnostic Response Positive response was received. -
2456.041751 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
2456.041751 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.62.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
2456.041751 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 62 -
2456.041751 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 62 fail
fail
11.62.5. (In for loop)Wait for FDC10 reached TestPass limit: None
2472.041751 1 Waited for 16.000 s -
11.63. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 63)
11.63.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
2472.041751 Diagnostic request 0x11, 0x01 -
2472.043183 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.43166ms (max=1000ms) -
2472.043183 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
2472.051605 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.4218ms (max=1200ms) -
2472.051605 Get Diagnostic Response Positive response was received. -
2472.051605 Diagnostic response 0x51, 0x01 -
2472.051605 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.63.2. (In for loop)Wait for the diagnostics to start: None
2474.451605 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.63.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
2474.451605 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
2474.453065 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.4603ms (max=1000ms) -
2474.453065 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
2474.470050 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.9845ms (max=1200ms) -
2474.470050 Get Diagnostic Response Positive response was received. -
2474.470050 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
2474.470050 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.63.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
2474.470050 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 63 -
2474.470050 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 63 fail
fail
11.63.5. (In for loop)Wait for FDC10 reached TestPass limit: None
2490.470050 1 Waited for 16.000 s -
11.64. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 64)
11.64.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
2490.470050 Diagnostic request 0x11, 0x01 -
2490.471555 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.50569ms (max=1000ms) -
2490.471555 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
2490.479899 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.3438ms (max=1200ms) -
2490.479899 Get Diagnostic Response Positive response was received. -
2490.479899 Diagnostic response 0x51, 0x01 -
2490.479899 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.64.2. (In for loop)Wait for the diagnostics to start: None
2492.879899 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.64.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
2492.879899 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
2492.881486 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.58681ms (max=1000ms) -
2492.881486 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
2492.898430 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.9445ms (max=1200ms) -
2492.898430 Get Diagnostic Response Positive response was received. -
2492.898430 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
2492.898430 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.64.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
2492.898430 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 64 -
2492.898430 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 64 fail
fail
11.64.5. (In for loop)Wait for FDC10 reached TestPass limit: None
2508.898430 1 Waited for 16.000 s -
11.65. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 65)
11.65.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
2508.898430 Diagnostic request 0x11, 0x01 -
2508.899949 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.51892ms (max=1000ms) -
2508.899949 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
2508.908281 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.3318ms (max=1200ms) -
2508.908281 Get Diagnostic Response Positive response was received. -
2508.908281 Diagnostic response 0x51, 0x01 -
2508.908281 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.65.2. (In for loop)Wait for the diagnostics to start: None
2511.308281 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.65.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
2511.308281 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
2511.309883 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.60214ms (max=1000ms) -
2511.309883 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
2511.326782 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.8985ms (max=1200ms) -
2511.326782 Get Diagnostic Response Positive response was received. -
2511.326782 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
2511.326782 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.65.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
2511.326782 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 65 -
2511.326782 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 65 fail
fail
11.65.5. (In for loop)Wait for FDC10 reached TestPass limit: None
2527.326782 1 Waited for 16.000 s -
11.66. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 66)
11.66.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
2527.326782 Diagnostic request 0x11, 0x01 -
2527.328198 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.41652ms (max=1000ms) -
2527.328198 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
2527.336634 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.4358ms (max=1200ms) -
2527.336634 Get Diagnostic Response Positive response was received. -
2527.336634 Diagnostic response 0x51, 0x01 -
2527.336634 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.66.2. (In for loop)Wait for the diagnostics to start: None
2529.736634 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.66.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
2529.736634 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
2529.738114 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.48003ms (max=1000ms) -
2529.738114 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
2529.755126 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.0125ms (max=1200ms) -
2529.755126 Get Diagnostic Response Positive response was received. -
2529.755126 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
2529.755126 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.66.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
2529.755126 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 66 -
2529.755126 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 66 fail
fail
11.66.5. (In for loop)Wait for FDC10 reached TestPass limit: None
2545.755126 1 Waited for 16.000 s -
11.67. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 67)
11.67.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
2545.755126 Diagnostic request 0x11, 0x01 -
2545.756618 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.49123ms (max=1000ms) -
2545.756618 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
2545.764979 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.36181ms (max=1200ms) -
2545.764979 Get Diagnostic Response Positive response was received. -
2545.764979 Diagnostic response 0x51, 0x01 -
2545.764979 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.67.2. (In for loop)Wait for the diagnostics to start: None
2548.164979 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.67.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
2548.164979 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
2548.166426 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.44675ms (max=1000ms) -
2548.166426 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
2548.183549 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.1225ms (max=1200ms) -
2548.183549 Get Diagnostic Response Positive response was received. -
2548.183549 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
2548.183549 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.67.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
2548.183549 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 67 -
2548.183549 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 67 fail
fail
11.67.5. (In for loop)Wait for FDC10 reached TestPass limit: None
2564.183549 1 Waited for 16.000 s -
11.68. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 68)
11.68.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
2564.183549 Diagnostic request 0x11, 0x01 -
2564.184928 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.37891ms (max=1000ms) -
2564.184928 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
2564.193401 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.47381ms (max=1200ms) -
2564.193401 Get Diagnostic Response Positive response was received. -
2564.193401 Diagnostic response 0x51, 0x01 -
2564.193401 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.68.2. (In for loop)Wait for the diagnostics to start: None
2566.593401 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.68.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
2566.593401 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
2566.594968 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.56645ms (max=1000ms) -
2566.594968 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
2566.611991 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.0229ms (max=1200ms) -
2566.611991 Get Diagnostic Response Positive response was received. -
2566.611991 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
2566.611991 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.68.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
2566.611991 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 68 -
2566.611991 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 68 fail
fail
11.68.5. (In for loop)Wait for FDC10 reached TestPass limit: None
2582.611991 1 Waited for 16.000 s -
11.69. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 69)
11.69.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
2582.611991 Diagnostic request 0x11, 0x01 -
2582.613384 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.39274ms (max=1000ms) -
2582.613384 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
2582.621845 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.4618ms (max=1200ms) -
2582.621845 Get Diagnostic Response Positive response was received. -
2582.621845 Diagnostic response 0x51, 0x01 -
2582.621845 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.69.2. (In for loop)Wait for the diagnostics to start: None
2585.021845 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.69.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
2585.021845 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
2585.023338 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.49226ms (max=1000ms) -
2585.023338 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
2585.040346 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.0085ms (max=1200ms) -
2585.040346 Get Diagnostic Response Positive response was received. -
2585.040346 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
2585.040346 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.69.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
2585.040346 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 69 -
2585.040346 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 69 fail
fail
11.69.5. (In for loop)Wait for FDC10 reached TestPass limit: None
2601.040346 1 Waited for 16.000 s -
11.70. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 70)
11.70.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
2601.040346 Diagnostic request 0x11, 0x01 -
2601.041843 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.49698ms (max=1000ms) -
2601.041843 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
2601.050199 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.3558ms (max=1200ms) -
2601.050199 Get Diagnostic Response Positive response was received. -
2601.050199 Diagnostic response 0x51, 0x01 -
2601.050199 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.70.2. (In for loop)Wait for the diagnostics to start: None
2603.450199 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.70.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
2603.450199 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
2603.451588 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.38872ms (max=1000ms) -
2603.451588 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
2603.468724 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.1365ms (max=1200ms) -
2603.468724 Get Diagnostic Response Positive response was received. -
2603.468724 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
2603.468724 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.70.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
2603.468724 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 70 -
2603.468724 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 70 fail
fail
11.70.5. (In for loop)Wait for FDC10 reached TestPass limit: None
2619.468724 1 Waited for 16.000 s -
11.71. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 71)
11.71.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
2619.468724 Diagnostic request 0x11, 0x01 -
2619.470154 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.42992ms (max=1000ms) -
2619.470154 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
2619.478576 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.4218ms (max=1200ms) -
2619.478576 Get Diagnostic Response Positive response was received. -
2619.478576 Diagnostic response 0x51, 0x01 -
2619.478576 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.71.2. (In for loop)Wait for the diagnostics to start: None
2621.878576 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.71.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
2621.878576 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
2621.879978 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.40269ms (max=1000ms) -
2621.879978 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
2621.897149 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.1705ms (max=1200ms) -
2621.897149 Get Diagnostic Response Positive response was received. -
2621.897149 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
2621.897149 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.71.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
2621.897149 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 71 -
2621.897149 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 71 fail
fail
11.71.5. (In for loop)Wait for FDC10 reached TestPass limit: None
2637.897149 1 Waited for 16.000 s -
11.72. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 72)
11.72.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
2637.897149 Diagnostic request 0x11, 0x01 -
2637.898458 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.3092ms (max=1000ms) -
2637.898458 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
2637.907000 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.54181ms (max=1200ms) -
2637.907000 Get Diagnostic Response Positive response was received. -
2637.907000 Diagnostic response 0x51, 0x01 -
2637.907000 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.72.2. (In for loop)Wait for the diagnostics to start: None
2640.307000 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.72.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
2640.307000 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
2640.308398 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.39839ms (max=1000ms) -
2640.308398 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
2640.325587 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.1885ms (max=1200ms) -
2640.325587 Get Diagnostic Response Positive response was received. -
2640.325587 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
2640.325587 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.72.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
2640.325587 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 72 -
2640.325587 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 72 fail
fail
11.72.5. (In for loop)Wait for FDC10 reached TestPass limit: None
2656.325587 1 Waited for 16.000 s -
11.73. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 73)
11.73.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
2656.325587 Diagnostic request 0x11, 0x01 -
2656.327006 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.41975ms (max=1000ms) -
2656.327006 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
2656.335438 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.43181ms (max=1200ms) -
2656.335438 Get Diagnostic Response Positive response was received. -
2656.335438 Diagnostic response 0x51, 0x01 -
2656.335438 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.73.2. (In for loop)Wait for the diagnostics to start: None
2658.735438 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.73.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
2658.735438 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
2658.737045 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.60638ms (max=1000ms) -
2658.737045 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
2658.753989 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.9445ms (max=1200ms) -
2658.753989 Get Diagnostic Response Positive response was received. -
2658.753989 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
2658.753989 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.73.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
2658.753989 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 73 -
2658.753989 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 73 fail
fail
11.73.5. (In for loop)Wait for FDC10 reached TestPass limit: None
2674.753989 1 Waited for 16.000 s -
11.74. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 74)
11.74.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
2674.753989 Diagnostic request 0x11, 0x01 -
2674.755545 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.55606ms (max=1000ms) -
2674.755545 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
2674.763841 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.29584ms (max=1200ms) -
2674.763841 Get Diagnostic Response Positive response was received. -
2674.763841 Diagnostic response 0x51, 0x01 -
2674.763841 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.74.2. (In for loop)Wait for the diagnostics to start: None
2677.163841 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.74.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
2677.163841 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
2677.165235 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.39419ms (max=1000ms) -
2677.165235 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
2677.182330 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.0945ms (max=1200ms) -
2677.182330 Get Diagnostic Response Positive response was received. -
2677.182330 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
2677.182330 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.74.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
2677.182330 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 74 -
2677.182330 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 74 fail
fail
11.74.5. (In for loop)Wait for FDC10 reached TestPass limit: None
2693.182330 1 Waited for 16.000 s -
11.75. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 75)
11.75.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
2693.182330 Diagnostic request 0x11, 0x01 -
2693.183854 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.52442ms (max=1000ms) -
2693.183854 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
2693.192182 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.3278ms (max=1200ms) -
2693.192182 Get Diagnostic Response Positive response was received. -
2693.192182 Diagnostic response 0x51, 0x01 -
2693.192182 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.75.2. (In for loop)Wait for the diagnostics to start: None
2695.592182 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.75.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
2695.592182 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
2695.593548 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.3657ms (max=1000ms) -
2695.593548 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
2695.610636 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.0885ms (max=1200ms) -
2695.610636 Get Diagnostic Response Positive response was received. -
2695.610636 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
2695.610636 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.75.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
2695.610636 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 75 -
2695.610636 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 75 fail
fail
11.75.5. (In for loop)Wait for FDC10 reached TestPass limit: None
2711.610636 1 Waited for 16.000 s -
11.76. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 76)
11.76.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
2711.610636 Diagnostic request 0x11, 0x01 -
2711.612025 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.38842ms (max=1000ms) -
2711.612025 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
2711.620484 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.45981ms (max=1200ms) -
2711.620484 Get Diagnostic Response Positive response was received. -
2711.620484 Diagnostic response 0x51, 0x01 -
2711.620484 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.76.2. (In for loop)Wait for the diagnostics to start: None
2714.020484 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.76.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
2714.020484 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
2714.021999 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.51448ms (max=1000ms) -
2714.021999 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
2714.039075 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.0765ms (max=1200ms) -
2714.039075 Get Diagnostic Response Positive response was received. -
2714.039075 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
2714.039075 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.76.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
2714.039075 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 76 -
2714.039075 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 76 fail
fail
11.76.5. (In for loop)Wait for FDC10 reached TestPass limit: None
2730.039075 1 Waited for 16.000 s -
11.77. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 77)
11.77.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
2730.039075 Diagnostic request 0x11, 0x01 -
2730.040407 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.3318ms (max=1000ms) -
2730.040407 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
2730.048927 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.5198ms (max=1200ms) -
2730.048927 Get Diagnostic Response Positive response was received. -
2730.048927 Diagnostic response 0x51, 0x01 -
2730.048927 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.77.2. (In for loop)Wait for the diagnostics to start: None
2732.448927 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.77.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
2732.448927 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
2732.450355 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.42783ms (max=1000ms) -
2732.450355 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
2732.467497 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.1425ms (max=1200ms) -
2732.467497 Get Diagnostic Response Positive response was received. -
2732.467497 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
2732.467497 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.77.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
2732.467497 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 77 -
2732.467497 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 77 fail
fail
11.77.5. (In for loop)Wait for FDC10 reached TestPass limit: None
2748.467497 1 Waited for 16.000 s -
11.78. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 78)
11.78.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
2748.467497 Diagnostic request 0x11, 0x01 -
2748.468921 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.42422ms (max=1000ms) -
2748.468921 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
2748.477347 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.42583ms (max=1200ms) -
2748.477347 Get Diagnostic Response Positive response was received. -
2748.477347 Diagnostic response 0x51, 0x01 -
2748.477347 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.78.2. (In for loop)Wait for the diagnostics to start: None
2750.877347 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.78.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
2750.877347 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
2750.879019 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.67195ms (max=1000ms) -
2750.879019 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
2750.896008 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.9885ms (max=1200ms) -
2750.896008 Get Diagnostic Response Positive response was received. -
2750.896008 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
2750.896008 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.78.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
2750.896008 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 78 -
2750.896008 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 78 fail
fail
11.78.5. (In for loop)Wait for FDC10 reached TestPass limit: None
2766.896008 1 Waited for 16.000 s -
11.79. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 79)
11.79.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
2766.896008 Diagnostic request 0x11, 0x01 -
2766.897426 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.41778ms (max=1000ms) -
2766.897426 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
2766.905851 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.4258ms (max=1200ms) -
2766.905851 Get Diagnostic Response Positive response was received. -
2766.905851 Diagnostic response 0x51, 0x01 -
2766.905851 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.79.2. (In for loop)Wait for the diagnostics to start: None
2769.305851 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.79.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
2769.305851 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
2769.307278 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.42619ms (max=1000ms) -
2769.307278 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
2769.324428 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.1505ms (max=1200ms) -
2769.324428 Get Diagnostic Response Positive response was received. -
2769.324428 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
2769.324428 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.79.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
2769.324428 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 79 -
2769.324428 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 79 fail
fail
11.79.5. (In for loop)Wait for FDC10 reached TestPass limit: None
2785.324428 1 Waited for 16.000 s -
11.80. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 80)
11.80.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
2785.324428 Diagnostic request 0x11, 0x01 -
2785.325939 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.51097ms (max=1000ms) -
2785.325939 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
2785.334273 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.3338ms (max=1200ms) -
2785.334273 Get Diagnostic Response Positive response was received. -
2785.334273 Diagnostic response 0x51, 0x01 -
2785.334273 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.80.2. (In for loop)Wait for the diagnostics to start: None
2787.734273 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.80.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
2787.734273 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
2787.735977 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.70389ms (max=1000ms) -
2787.735977 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
2787.752809 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.8325ms (max=1200ms) -
2787.752809 Get Diagnostic Response Positive response was received. -
2787.752809 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
2787.752809 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.80.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
2787.752809 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 80 -
2787.752809 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 80 fail
fail
11.80.5. (In for loop)Wait for FDC10 reached TestPass limit: None
2803.752809 1 Waited for 16.000 s -
11.81. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 81)
11.81.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
2803.752809 Diagnostic request 0x11, 0x01 -
2803.754163 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.35358ms (max=1000ms) -
2803.754163 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
2803.762662 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.49983ms (max=1200ms) -
2803.762662 Get Diagnostic Response Positive response was received. -
2803.762662 Diagnostic response 0x51, 0x01 -
2803.762662 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.81.2. (In for loop)Wait for the diagnostics to start: None
2806.162662 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.81.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
2806.162662 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
2806.164084 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.42177ms (max=1000ms) -
2806.164084 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
2806.181255 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.1705ms (max=1200ms) -
2806.181255 Get Diagnostic Response Positive response was received. -
2806.181255 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
2806.181255 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.81.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
2806.181255 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 81 -
2806.181255 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 81 fail
fail
11.81.5. (In for loop)Wait for FDC10 reached TestPass limit: None
2822.181255 1 Waited for 16.000 s -
11.82. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 82)
11.82.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
2822.181255 Diagnostic request 0x11, 0x01 -
2822.182802 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.54742ms (max=1000ms) -
2822.182802 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
2822.191106 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.3038ms (max=1200ms) -
2822.191106 Get Diagnostic Response Positive response was received. -
2822.191106 Diagnostic response 0x51, 0x01 -
2822.191106 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.82.2. (In for loop)Wait for the diagnostics to start: None
2824.591106 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.82.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
2824.591106 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
2824.592477 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.37123ms (max=1000ms) -
2824.592477 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
2824.609552 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.0745ms (max=1200ms) -
2824.609552 Get Diagnostic Response Positive response was received. -
2824.609552 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
2824.609552 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.82.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
2824.609552 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 82 -
2824.609552 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 82 fail
fail
11.82.5. (In for loop)Wait for FDC10 reached TestPass limit: None
2840.609552 1 Waited for 16.000 s -
11.83. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 83)
11.83.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
2840.609552 Diagnostic request 0x11, 0x01 -
2840.611034 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.48211ms (max=1000ms) -
2840.611034 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
2840.619402 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.36781ms (max=1200ms) -
2840.619402 Get Diagnostic Response Positive response was received. -
2840.619402 Diagnostic response 0x51, 0x01 -
2840.619402 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.83.2. (In for loop)Wait for the diagnostics to start: None
2843.019402 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.83.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
2843.019402 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
2843.020951 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.54919ms (max=1000ms) -
2843.020951 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
2843.037909 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.9585ms (max=1200ms) -
2843.037909 Get Diagnostic Response Positive response was received. -
2843.037909 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
2843.037909 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.83.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
2843.037909 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 83 -
2843.037909 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 83 fail
fail
11.83.5. (In for loop)Wait for FDC10 reached TestPass limit: None
2859.037909 1 Waited for 16.000 s -
11.84. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 84)
11.84.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
2859.037909 Diagnostic request 0x11, 0x01 -
2859.039309 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.39936ms (max=1000ms) -
2859.039309 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
2859.047752 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.44383ms (max=1200ms) -
2859.047752 Get Diagnostic Response Positive response was received. -
2859.047752 Diagnostic response 0x51, 0x01 -
2859.047752 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.84.2. (In for loop)Wait for the diagnostics to start: None
2861.447752 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.84.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
2861.447752 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
2861.449230 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.47791ms (max=1000ms) -
2861.449230 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
2861.466291 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.0605ms (max=1200ms) -
2861.466291 Get Diagnostic Response Positive response was received. -
2861.466291 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
2861.466291 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.84.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
2861.466291 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 84 -
2861.466291 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 84 fail
fail
11.84.5. (In for loop)Wait for FDC10 reached TestPass limit: None
2877.466291 1 Waited for 16.000 s -
11.85. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 85)
11.85.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
2877.466291 Diagnostic request 0x11, 0x01 -
2877.467767 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.47611ms (max=1000ms) -
2877.467767 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
2877.476143 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.3758ms (max=1200ms) -
2877.476143 Get Diagnostic Response Positive response was received. -
2877.476143 Diagnostic response 0x51, 0x01 -
2877.476143 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.85.2. (In for loop)Wait for the diagnostics to start: None
2879.876143 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.85.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
2879.876143 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
2879.877539 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.39672ms (max=1000ms) -
2879.877539 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
2879.894654 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.1145ms (max=1200ms) -
2879.894654 Get Diagnostic Response Positive response was received. -
2879.894654 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
2879.894654 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.85.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
2879.894654 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 85 -
2879.894654 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 85 fail
fail
11.85.5. (In for loop)Wait for FDC10 reached TestPass limit: None
2895.894654 1 Waited for 16.000 s -
11.86. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 86)
11.86.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
2895.894654 Diagnostic request 0x11, 0x01 -
2895.896081 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.42661ms (max=1000ms) -
2895.896081 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
2895.904506 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.4258ms (max=1200ms) -
2895.904506 Get Diagnostic Response Positive response was received. -
2895.904506 Diagnostic response 0x51, 0x01 -
2895.904506 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.86.2. (In for loop)Wait for the diagnostics to start: None
2898.304506 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.86.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
2898.304506 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
2898.305996 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.48925ms (max=1000ms) -
2898.305996 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
2898.322974 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.9785ms (max=1200ms) -
2898.322974 Get Diagnostic Response Positive response was received. -
2898.322974 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
2898.322974 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.86.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
2898.322974 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 86 -
2898.322974 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 86 fail
fail
11.86.5. (In for loop)Wait for FDC10 reached TestPass limit: None
2914.322974 1 Waited for 16.000 s -
11.87. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 87)
11.87.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
2914.322974 Diagnostic request 0x11, 0x01 -
2914.324440 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.46614ms (max=1000ms) -
2914.324440 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
2914.332830 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.38984ms (max=1200ms) -
2914.332830 Get Diagnostic Response Positive response was received. -
2914.332830 Diagnostic response 0x51, 0x01 -
2914.332830 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.87.2. (In for loop)Wait for the diagnostics to start: None
2916.732830 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.87.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
2916.732830 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
2916.734250 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.41984ms (max=1000ms) -
2916.734250 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
2916.751316 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.0665ms (max=1200ms) -
2916.751316 Get Diagnostic Response Positive response was received. -
2916.751316 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
2916.751316 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.87.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
2916.751316 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 87 -
2916.751316 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 87 fail
fail
11.87.5. (In for loop)Wait for FDC10 reached TestPass limit: None
2932.751316 1 Waited for 16.000 s -
11.88. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 88)
11.88.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
2932.751316 Diagnostic request 0x11, 0x01 -
2932.752827 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.51022ms (max=1000ms) -
2932.752827 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
2932.761166 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.33984ms (max=1200ms) -
2932.761166 Get Diagnostic Response Positive response was received. -
2932.761166 Diagnostic response 0x51, 0x01 -
2932.761166 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.88.2. (In for loop)Wait for the diagnostics to start: None
2935.161166 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.88.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
2935.161166 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
2935.162535 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.36861ms (max=1000ms) -
2935.162535 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
2935.179634 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.0985ms (max=1200ms) -
2935.179634 Get Diagnostic Response Positive response was received. -
2935.179634 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
2935.179634 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.88.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
2935.179634 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 88 -
2935.179634 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 88 fail
fail
11.88.5. (In for loop)Wait for FDC10 reached TestPass limit: None
2951.179634 1 Waited for 16.000 s -
11.89. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 89)
11.89.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
2951.179634 Diagnostic request 0x11, 0x01 -
2951.181115 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.48114ms (max=1000ms) -
2951.181115 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
2951.189484 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.36981ms (max=1200ms) -
2951.189484 Get Diagnostic Response Positive response was received. -
2951.189484 Diagnostic response 0x51, 0x01 -
2951.189484 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.89.2. (In for loop)Wait for the diagnostics to start: None
2953.589484 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.89.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
2953.589484 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
2953.591120 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.63594ms (max=1000ms) -
2953.591120 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
2953.608009 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.8885ms (max=1200ms) -
2953.608009 Get Diagnostic Response Positive response was received. -
2953.608009 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
2953.608009 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.89.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
2953.608009 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 89 -
2953.608009 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 89 fail
fail
11.89.5. (In for loop)Wait for FDC10 reached TestPass limit: None
2969.608009 1 Waited for 16.000 s -
11.90. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 90)
11.90.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
2969.608009 Diagnostic request 0x11, 0x01 -
2969.609441 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.4317ms (max=1000ms) -
2969.609441 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
2969.617864 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.4238ms (max=1200ms) -
2969.617864 Get Diagnostic Response Positive response was received. -
2969.617864 Diagnostic response 0x51, 0x01 -
2969.617864 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.90.2. (In for loop)Wait for the diagnostics to start: None
2972.017864 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.90.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
2972.017864 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
2972.019339 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.47491ms (max=1000ms) -
2972.019339 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
2972.036332 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.9925ms (max=1200ms) -
2972.036332 Get Diagnostic Response Positive response was received. -
2972.036332 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
2972.036332 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.90.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
2972.036332 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 90 -
2972.036332 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 90 fail
fail
11.90.5. (In for loop)Wait for FDC10 reached TestPass limit: None
2988.036332 1 Waited for 16.000 s -
11.91. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 91)
11.91.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
2988.036332 Diagnostic request 0x11, 0x01 -
2988.037892 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.55966ms (max=1000ms) -
2988.037892 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
2988.046183 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.29183ms (max=1200ms) -
2988.046183 Get Diagnostic Response Positive response was received. -
2988.046183 Diagnostic response 0x51, 0x01 -
2988.046183 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.91.2. (In for loop)Wait for the diagnostics to start: None
2990.446183 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.91.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
2990.446183 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
2990.447569 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.38525ms (max=1000ms) -
2990.447569 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
2990.464599 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.0305ms (max=1200ms) -
2990.464599 Get Diagnostic Response Positive response was received. -
2990.464599 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
2990.464599 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.91.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
2990.464599 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 91 -
2990.464599 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 91 fail
fail
11.91.5. (In for loop)Wait for FDC10 reached TestPass limit: None
3006.464599 1 Waited for 16.000 s -
11.92. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 92)
11.92.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
3006.464599 Diagnostic request 0x11, 0x01 -
3006.466057 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.45811ms (max=1000ms) -
3006.466057 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
3006.474455 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.3978ms (max=1200ms) -
3006.474455 Get Diagnostic Response Positive response was received. -
3006.474455 Diagnostic response 0x51, 0x01 -
3006.474455 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.92.2. (In for loop)Wait for the diagnostics to start: None
3008.874455 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.92.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
3008.874455 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
3008.876011 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.55559ms (max=1000ms) -
3008.876011 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
3008.892801 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.7905ms (max=1200ms) -
3008.892801 Get Diagnostic Response Positive response was received. -
3008.892801 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
3008.892801 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.92.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
3008.892801 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 92 -
3008.892801 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 92 fail
fail
11.92.5. (In for loop)Wait for FDC10 reached TestPass limit: None
3024.892801 1 Waited for 16.000 s -
11.93. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 93)
11.93.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
3024.892801 Diagnostic request 0x11, 0x01 -
3024.894227 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.42561ms (max=1000ms) -
3024.894227 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
3024.902650 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.4238ms (max=1200ms) -
3024.902650 Get Diagnostic Response Positive response was received. -
3024.902650 Diagnostic response 0x51, 0x01 -
3024.902650 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.93.2. (In for loop)Wait for the diagnostics to start: None
3027.302650 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.93.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
3027.302650 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
3027.304070 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.41975ms (max=1000ms) -
3027.304070 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
3027.321063 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.9925ms (max=1200ms) -
3027.321063 Get Diagnostic Response Positive response was received. -
3027.321063 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
3027.321063 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.93.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
3027.321063 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 93 -
3027.321063 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 93 fail
fail
11.93.5. (In for loop)Wait for FDC10 reached TestPass limit: None
3043.321063 1 Waited for 16.000 s -
11.94. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 94)
11.94.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
3043.321063 Diagnostic request 0x11, 0x01 -
3043.322413 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.35034ms (max=1000ms) -
3043.322413 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
3043.330913 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.4998ms (max=1200ms) -
3043.330913 Get Diagnostic Response Positive response was received. -
3043.330913 Diagnostic response 0x51, 0x01 -
3043.330913 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.94.2. (In for loop)Wait for the diagnostics to start: None
3045.730913 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.94.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
3045.730913 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
3045.732333 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.42022ms (max=1000ms) -
3045.732333 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
3045.749452 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.1185ms (max=1200ms) -
3045.749452 Get Diagnostic Response Positive response was received. -
3045.749452 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
3045.749452 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.94.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
3045.749452 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 94 -
3045.749452 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 94 fail
fail
11.94.5. (In for loop)Wait for FDC10 reached TestPass limit: None
3061.749452 1 Waited for 16.000 s -
11.95. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 95)
11.95.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
3061.749452 Diagnostic request 0x11, 0x01 -
3061.750927 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.47511ms (max=1000ms) -
3061.750927 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
3061.759301 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.37384ms (max=1200ms) -
3061.759301 Get Diagnostic Response Positive response was received. -
3061.759301 Diagnostic response 0x51, 0x01 -
3061.759301 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.95.2. (In for loop)Wait for the diagnostics to start: None
3064.159301 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.95.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
3064.159301 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
3064.160996 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.69541ms (max=1000ms) -
3064.160996 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
3064.177894 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.8985ms (max=1200ms) -
3064.177894 Get Diagnostic Response Positive response was received. -
3064.177894 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
3064.177894 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.95.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
3064.177894 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 95 -
3064.177894 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 95 fail
fail
11.95.5. (In for loop)Wait for FDC10 reached TestPass limit: None
3080.177894 1 Waited for 16.000 s -
11.96. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 96)
11.96.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
3080.177894 Diagnostic request 0x11, 0x01 -
3080.179358 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.46334ms (max=1000ms) -
3080.179358 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
3080.187746 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.3878ms (max=1200ms) -
3080.187746 Get Diagnostic Response Positive response was received. -
3080.187746 Diagnostic response 0x51, 0x01 -
3080.187746 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.96.2. (In for loop)Wait for the diagnostics to start: None
3082.587746 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.96.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
3082.587746 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
3082.589267 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.52133ms (max=1000ms) -
3082.589267 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
3082.606389 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.1225ms (max=1200ms) -
3082.606389 Get Diagnostic Response Positive response was received. -
3082.606389 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
3082.606389 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.96.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
3082.606389 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 96 -
3082.606389 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 96 fail
fail
11.96.5. (In for loop)Wait for FDC10 reached TestPass limit: None
3098.606389 1 Waited for 16.000 s -
11.97. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 97)
11.97.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
3098.606389 Diagnostic request 0x11, 0x01 -
3098.607909 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.51958ms (max=1000ms) -
3098.607909 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
3098.616183 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.2738ms (max=1200ms) -
3098.616183 Get Diagnostic Response Positive response was received. -
3098.616183 Diagnostic response 0x51, 0x01 -
3098.616183 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.97.2. (In for loop)Wait for the diagnostics to start: None
3101.016183 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.97.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
3101.016183 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
3101.017542 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.35925ms (max=1000ms) -
3101.017542 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
3101.034672 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.1305ms (max=1200ms) -
3101.034672 Get Diagnostic Response Positive response was received. -
3101.034672 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
3101.034672 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.97.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
3101.034672 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 97 -
3101.034672 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 97 fail
fail
11.97.5. (In for loop)Wait for FDC10 reached TestPass limit: None
3117.034672 1 Waited for 16.000 s -
11.98. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 98)
11.98.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
3117.034672 Diagnostic request 0x11, 0x01 -
3117.036081 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.40848ms (max=1000ms) -
3117.036081 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
3117.044525 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.4438ms (max=1200ms) -
3117.044525 Get Diagnostic Response Positive response was received. -
3117.044525 Diagnostic response 0x51, 0x01 -
3117.044525 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.98.2. (In for loop)Wait for the diagnostics to start: None
3119.444525 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.98.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
3119.444525 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
3119.446011 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.48598ms (max=1000ms) -
3119.446011 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
3119.462981 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.9705ms (max=1200ms) -
3119.462981 Get Diagnostic Response Positive response was received. -
3119.462981 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
3119.462981 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.98.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
3119.462981 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 98 -
3119.462981 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 98 fail
fail
11.98.5. (In for loop)Wait for FDC10 reached TestPass limit: None
3135.462981 1 Waited for 16.000 s -
11.99. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 99)
11.99.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
3135.462981 Diagnostic request 0x11, 0x01 -
3135.464488 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.50731ms (max=1000ms) -
3135.464488 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
3135.472828 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.33981ms (max=1200ms) -
3135.472828 Get Diagnostic Response Positive response was received. -
3135.472828 Diagnostic response 0x51, 0x01 -
3135.472828 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.99.2. (In for loop)Wait for the diagnostics to start: None
3137.872828 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.99.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
3137.872828 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
3137.874323 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.49472ms (max=1000ms) -
3137.874323 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
3137.891242 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.9185ms (max=1200ms) -
3137.891242 Get Diagnostic Response Positive response was received. -
3137.891242 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
3137.891242 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.99.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
3137.891242 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 99 -
3137.891242 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 99 fail
fail
11.99.5. (In for loop)Wait for FDC10 reached TestPass limit: None
3153.891242 1 Waited for 16.000 s -
11.100. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 100)
11.100.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
3153.891242 Diagnostic request 0x11, 0x01 -
3153.892744 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.50202ms (max=1000ms) -
3153.892744 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
3153.901095 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.3518ms (max=1200ms) -
3153.901095 Get Diagnostic Response Positive response was received. -
3153.901095 Diagnostic response 0x51, 0x01 -
3153.901095 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.100.2. (In for loop)Wait for the diagnostics to start: None
3156.301095 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.100.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
3156.301095 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
3156.302498 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.40266ms (max=1000ms) -
3156.302498 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
3156.319562 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.0645ms (max=1200ms) -
3156.319562 Get Diagnostic Response Positive response was received. -
3156.319562 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
3156.319562 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.100.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
3156.319562 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 100 -
3156.319562 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 100 fail
fail
11.100.5. (In for loop)Wait for FDC10 reached TestPass limit: None
3172.319562 1 Waited for 16.000 s -
11.101. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 101)
11.101.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
3172.319562 Diagnostic request 0x11, 0x01 -
3172.321128 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.56509ms (max=1000ms) -
3172.321128 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
3172.329415 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.28781ms (max=1200ms) -
3172.329415 Get Diagnostic Response Positive response was received. -
3172.329415 Diagnostic response 0x51, 0x01 -
3172.329415 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.101.2. (In for loop)Wait for the diagnostics to start: None
3174.729415 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.101.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
3174.729415 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
3174.731084 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.66877ms (max=1000ms) -
3174.731084 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
3174.747849 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.7645ms (max=1200ms) -
3174.747849 Get Diagnostic Response Positive response was received. -
3174.747849 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
3174.747849 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.101.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
3174.747849 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 101 -
3174.747849 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 101 fail
fail
11.101.5. (In for loop)Wait for FDC10 reached TestPass limit: None
3190.747849 1 Waited for 16.000 s -
11.102. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 102)
11.102.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
3190.747849 Diagnostic request 0x11, 0x01 -
3190.749210 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.36153ms (max=1000ms) -
3190.749210 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
3190.757704 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.49381ms (max=1200ms) -
3190.757704 Get Diagnostic Response Positive response was received. -
3190.757704 Diagnostic response 0x51, 0x01 -
3190.757704 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.102.2. (In for loop)Wait for the diagnostics to start: None
3193.157704 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.102.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
3193.157704 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
3193.159155 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.45061ms (max=1000ms) -
3193.159155 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
3193.176213 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.0585ms (max=1200ms) -
3193.176213 Get Diagnostic Response Positive response was received. -
3193.176213 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
3193.176213 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.102.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
3193.176213 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 102 -
3193.176213 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 102 fail
fail
11.102.5. (In for loop)Wait for FDC10 reached TestPass limit: None
3209.176213 1 Waited for 16.000 s -
11.103. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 103)
11.103.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
3209.176213 Diagnostic request 0x11, 0x01 -
3209.177469 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.25545ms (max=1000ms) -
3209.177469 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
3209.186064 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.59583ms (max=1200ms) -
3209.186064 Get Diagnostic Response Positive response was received. -
3209.186064 Diagnostic response 0x51, 0x01 -
3209.186064 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.103.2. (In for loop)Wait for the diagnostics to start: None
3211.586064 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.103.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
3211.586064 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
3211.587430 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.36548ms (max=1000ms) -
3211.587430 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
3211.604616 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.1865ms (max=1200ms) -
3211.604616 Get Diagnostic Response Positive response was received. -
3211.604616 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
3211.604616 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.103.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
3211.604616 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 103 -
3211.604616 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 103 fail
fail
11.103.5. (In for loop)Wait for FDC10 reached TestPass limit: None
3227.604616 1 Waited for 16.000 s -
11.104. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 104)
11.104.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
3227.604616 Diagnostic request 0x11, 0x01 -
3227.606063 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.44659ms (max=1000ms) -
3227.606063 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
3227.614405 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.34181ms (max=1200ms) -
3227.614405 Get Diagnostic Response Positive response was received. -
3227.614405 Diagnostic response 0x51, 0x01 -
3227.614405 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.104.2. (In for loop)Wait for the diagnostics to start: None
3230.014405 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.104.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
3230.014405 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
3230.015954 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.54872ms (max=1000ms) -
3230.015954 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
3230.032916 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.9625ms (max=1200ms) -
3230.032916 Get Diagnostic Response Positive response was received. -
3230.032916 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
3230.032916 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.104.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
3230.032916 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 104 -
3230.032916 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 104 fail
fail
11.104.5. (In for loop)Wait for FDC10 reached TestPass limit: None
3246.032916 1 Waited for 16.000 s -
11.105. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 105)
11.105.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
3246.032916 Diagnostic request 0x11, 0x01 -
3246.034278 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.36228ms (max=1000ms) -
3246.034278 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
3246.042770 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.4918ms (max=1200ms) -
3246.042770 Get Diagnostic Response Positive response was received. -
3246.042770 Diagnostic response 0x51, 0x01 -
3246.042770 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.105.2. (In for loop)Wait for the diagnostics to start: None
3248.442770 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.105.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
3248.442770 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
3248.444243 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.47261ms (max=1000ms) -
3248.444243 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
3248.461259 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.0165ms (max=1200ms) -
3248.461259 Get Diagnostic Response Positive response was received. -
3248.461259 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
3248.461259 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.105.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
3248.461259 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 105 -
3248.461259 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 105 fail
fail
11.105.5. (In for loop)Wait for FDC10 reached TestPass limit: None
3264.461259 1 Waited for 16.000 s -
11.106. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 106)
11.106.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
3264.461259 Diagnostic request 0x11, 0x01 -
3264.462698 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.43886ms (max=1000ms) -
3264.462698 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
3264.471116 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.4178ms (max=1200ms) -
3264.471116 Get Diagnostic Response Positive response was received. -
3264.471116 Diagnostic response 0x51, 0x01 -
3264.471116 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.106.2. (In for loop)Wait for the diagnostics to start: None
3266.871116 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.106.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
3266.871116 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
3266.872512 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.3965ms (max=1000ms) -
3266.872512 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
3266.889675 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.1625ms (max=1200ms) -
3266.889675 Get Diagnostic Response Positive response was received. -
3266.889675 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
3266.889675 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.106.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
3266.889675 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 106 -
3266.889675 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 106 fail
fail
11.106.5. (In for loop)Wait for FDC10 reached TestPass limit: None
3282.889675 1 Waited for 16.000 s -
11.107. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 107)
11.107.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
3282.889675 Diagnostic request 0x11, 0x01 -
3282.891158 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.48345ms (max=1000ms) -
3282.891158 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
3282.899530 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.3718ms (max=1200ms) -
3282.899530 Get Diagnostic Response Positive response was received. -
3282.899530 Diagnostic response 0x51, 0x01 -
3282.899530 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.107.2. (In for loop)Wait for the diagnostics to start: None
3285.299530 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.107.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
3285.299530 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
3285.301076 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.54551ms (max=1000ms) -
3285.301076 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
3285.318150 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.0745ms (max=1200ms) -
3285.318150 Get Diagnostic Response Positive response was received. -
3285.318150 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
3285.318150 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.107.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
3285.318150 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 107 -
3285.318150 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 107 fail
fail
11.107.5. (In for loop)Wait for FDC10 reached TestPass limit: None
3301.318150 1 Waited for 16.000 s -
11.108. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 108)
11.108.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
3301.318150 Diagnostic request 0x11, 0x01 -
3301.319464 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.31392ms (max=1000ms) -
3301.319464 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
3301.328006 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.5418ms (max=1200ms) -
3301.328006 Get Diagnostic Response Positive response was received. -
3301.328006 Diagnostic response 0x51, 0x01 -
3301.328006 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.108.2. (In for loop)Wait for the diagnostics to start: None
3303.728006 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.108.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
3303.728006 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
3303.729458 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.45234ms (max=1000ms) -
3303.729458 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
3303.746563 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.1045ms (max=1200ms) -
3303.746563 Get Diagnostic Response Positive response was received. -
3303.746563 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
3303.746563 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.108.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
3303.746563 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 108 -
3303.746563 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 108 fail
fail
11.108.5. (In for loop)Wait for FDC10 reached TestPass limit: None
3319.746563 1 Waited for 16.000 s -
11.109. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 109)
11.109.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
3319.746563 Diagnostic request 0x11, 0x01 -
3319.747937 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.37431ms (max=1000ms) -
3319.747937 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
3319.756413 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.4758ms (max=1200ms) -
3319.756413 Get Diagnostic Response Positive response was received. -
3319.756413 Diagnostic response 0x51, 0x01 -
3319.756413 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.109.2. (In for loop)Wait for the diagnostics to start: None
3322.156413 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.109.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
3322.156413 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
3322.158025 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.61225ms (max=1000ms) -
3322.158025 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
3322.175015 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.9905ms (max=1200ms) -
3322.175015 Get Diagnostic Response Positive response was received. -
3322.175015 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
3322.175015 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.109.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
3322.175015 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 109 -
3322.175015 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 109 fail
fail
11.109.5. (In for loop)Wait for FDC10 reached TestPass limit: None
3338.175015 1 Waited for 16.000 s -
11.110. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 110)
11.110.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
3338.175015 Diagnostic request 0x11, 0x01 -
3338.176483 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.46716ms (max=1000ms) -
3338.176483 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
3338.184866 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.38381ms (max=1200ms) -
3338.184866 Get Diagnostic Response Positive response was received. -
3338.184866 Diagnostic response 0x51, 0x01 -
3338.184866 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.110.2. (In for loop)Wait for the diagnostics to start: None
3340.584866 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.110.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
3340.584866 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
3340.586338 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.47186ms (max=1000ms) -
3340.586338 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
3340.603471 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.1325ms (max=1200ms) -
3340.603471 Get Diagnostic Response Positive response was received. -
3340.603471 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
3340.603471 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.110.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
3340.603471 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 110 -
3340.603471 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 110 fail
fail
11.110.5. (In for loop)Wait for FDC10 reached TestPass limit: None
3356.603471 1 Waited for 16.000 s -
11.111. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 111)
11.111.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
3356.603471 Diagnostic request 0x11, 0x01 -
3356.604907 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.43634ms (max=1000ms) -
3356.604907 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
3356.613261 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.3538ms (max=1200ms) -
3356.613261 Get Diagnostic Response Positive response was received. -
3356.613261 Diagnostic response 0x51, 0x01 -
3356.613261 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.111.2. (In for loop)Wait for the diagnostics to start: None
3359.013261 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.111.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
3359.013261 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
3359.014888 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.62722ms (max=1000ms) -
3359.014888 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
3359.031707 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.8185ms (max=1200ms) -
3359.031707 Get Diagnostic Response Positive response was received. -
3359.031707 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
3359.031707 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.111.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
3359.031707 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 111 -
3359.031707 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 111 fail
fail
11.111.5. (In for loop)Wait for FDC10 reached TestPass limit: None
3375.031707 1 Waited for 16.000 s -
11.112. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 112)
11.112.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
3375.031707 Diagnostic request 0x11, 0x01 -
3375.033121 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.41481ms (max=1000ms) -
3375.033121 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
3375.041561 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.43981ms (max=1200ms) -
3375.041561 Get Diagnostic Response Positive response was received. -
3375.041561 Diagnostic response 0x51, 0x01 -
3375.041561 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.112.2. (In for loop)Wait for the diagnostics to start: None
3377.441561 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.112.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
3377.441561 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
3377.443051 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.48989ms (max=1000ms) -
3377.443051 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
3377.460076 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.0245ms (max=1200ms) -
3377.460076 Get Diagnostic Response Positive response was received. -
3377.460076 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
3377.460076 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.112.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
3377.460076 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 112 -
3377.460076 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 112 fail
fail
11.112.5. (In for loop)Wait for FDC10 reached TestPass limit: None
3393.460076 1 Waited for 16.000 s -
11.113. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 113)
11.113.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
3393.460076 Diagnostic request 0x11, 0x01 -
3393.461539 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.46388ms (max=1000ms) -
3393.461539 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
3393.469929 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.3898ms (max=1200ms) -
3393.469929 Get Diagnostic Response Positive response was received. -
3393.469929 Diagnostic response 0x51, 0x01 -
3393.469929 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.113.2. (In for loop)Wait for the diagnostics to start: None
3395.869929 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.113.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
3395.869929 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
3395.871446 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.51713ms (max=1000ms) -
3395.871446 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
3395.888337 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.8905ms (max=1200ms) -
3395.888337 Get Diagnostic Response Positive response was received. -
3395.888337 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
3395.888337 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.113.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
3395.888337 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 113 -
3395.888337 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 113 fail
fail
11.113.5. (In for loop)Wait for FDC10 reached TestPass limit: None
3411.888337 1 Waited for 16.000 s -
11.114. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 114)
11.114.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
3411.888337 Diagnostic request 0x11, 0x01 -
3411.889752 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.4147ms (max=1000ms) -
3411.889752 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
3411.898189 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.43781ms (max=1200ms) -
3411.898189 Get Diagnostic Response Positive response was received. -
3411.898189 Diagnostic response 0x51, 0x01 -
3411.898189 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.114.2. (In for loop)Wait for the diagnostics to start: None
3414.298189 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.114.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
3414.298189 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
3414.299538 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.34872ms (max=1000ms) -
3414.299538 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
3414.316753 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.2145ms (max=1200ms) -
3414.316753 Get Diagnostic Response Positive response was received. -
3414.316753 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
3414.316753 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.114.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
3414.316753 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 114 -
3414.316753 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 114 fail
fail
11.114.5. (In for loop)Wait for FDC10 reached TestPass limit: None
3430.316753 1 Waited for 16.000 s -
11.115. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 115)
11.115.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
3430.316753 Diagnostic request 0x11, 0x01 -
3430.318206 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.45372ms (max=1000ms) -
3430.318206 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
3430.326604 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.39783ms (max=1200ms) -
3430.326604 Get Diagnostic Response Positive response was received. -
3430.326604 Diagnostic response 0x51, 0x01 -
3430.326604 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.115.2. (In for loop)Wait for the diagnostics to start: None
3432.726604 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.115.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
3432.726604 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
3432.728112 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.50786ms (max=1000ms) -
3432.728112 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
3432.745143 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.0305ms (max=1200ms) -
3432.745143 Get Diagnostic Response Positive response was received. -
3432.745143 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
3432.745143 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.115.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
3432.745143 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 115 -
3432.745143 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 115 fail
fail
11.115.5. (In for loop)Wait for FDC10 reached TestPass limit: None
3448.745143 1 Waited for 16.000 s -
11.116. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 116)
11.116.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
3448.745143 Diagnostic request 0x11, 0x01 -
3448.746462 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.31931ms (max=1000ms) -
3448.746462 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
3448.754992 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.5298ms (max=1200ms) -
3448.754992 Get Diagnostic Response Positive response was received. -
3448.754992 Diagnostic response 0x51, 0x01 -
3448.754992 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.116.2. (In for loop)Wait for the diagnostics to start: None
3451.154992 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.116.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
3451.154992 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
3451.156528 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.53633ms (max=1000ms) -
3451.156528 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
3451.173546 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.0185ms (max=1200ms) -
3451.173546 Get Diagnostic Response Positive response was received. -
3451.173546 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
3451.173546 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.116.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
3451.173546 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 116 -
3451.173546 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 116 fail
fail
11.116.5. (In for loop)Wait for FDC10 reached TestPass limit: None
3467.173546 1 Waited for 16.000 s -
11.117. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 117)
11.117.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
3467.173546 Diagnostic request 0x11, 0x01 -
3467.175016 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.46989ms (max=1000ms) -
3467.175016 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
3467.183400 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.38383ms (max=1200ms) -
3467.183400 Get Diagnostic Response Positive response was received. -
3467.183400 Diagnostic response 0x51, 0x01 -
3467.183400 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.117.2. (In for loop)Wait for the diagnostics to start: None
3469.583400 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.117.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
3469.583400 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
3469.584874 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.47344ms (max=1000ms) -
3469.584874 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
3469.602020 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.1465ms (max=1200ms) -
3469.602020 Get Diagnostic Response Positive response was received. -
3469.602020 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
3469.602020 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.117.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
3469.602020 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 117 -
3469.602020 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 117 fail
fail
11.117.5. (In for loop)Wait for FDC10 reached TestPass limit: None
3485.602020 1 Waited for 16.000 s -
11.118. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 118)
11.118.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
3485.602020 Diagnostic request 0x11, 0x01 -
3485.603445 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.42455ms (max=1000ms) -
3485.603445 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
3485.611810 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.3658ms (max=1200ms) -
3485.611810 Get Diagnostic Response Positive response was received. -
3485.611810 Diagnostic response 0x51, 0x01 -
3485.611810 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.118.2. (In for loop)Wait for the diagnostics to start: None
3488.011810 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.118.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
3488.011810 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
3488.013310 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.49919ms (max=1000ms) -
3488.013310 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
3488.030388 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.0785ms (max=1200ms) -
3488.030388 Get Diagnostic Response Positive response was received. -
3488.030388 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
3488.030388 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.118.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
3488.030388 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 118 -
3488.030388 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 118 fail
fail
11.118.5. (In for loop)Wait for FDC10 reached TestPass limit: None
3504.030388 1 Waited for 16.000 s -
11.119. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 119)
11.119.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
3504.030388 Diagnostic request 0x11, 0x01 -
3504.031925 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.53716ms (max=1000ms) -
3504.031925 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
3504.040241 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.3158ms (max=1200ms) -
3504.040241 Get Diagnostic Response Positive response was received. -
3504.040241 Diagnostic response 0x51, 0x01 -
3504.040241 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.119.2. (In for loop)Wait for the diagnostics to start: None
3506.440241 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.119.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
3506.440241 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
3506.441872 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.63094ms (max=1000ms) -
3506.441872 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
3506.458820 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.9485ms (max=1200ms) -
3506.458820 Get Diagnostic Response Positive response was received. -
3506.458820 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
3506.458820 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.119.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
3506.458820 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 119 -
3506.458820 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 119 fail
fail
11.119.5. (In for loop)Wait for FDC10 reached TestPass limit: None
3522.458820 1 Waited for 16.000 s -
11.120. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 120)
11.120.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
3522.458820 Diagnostic request 0x11, 0x01 -
3522.460191 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.37067ms (max=1000ms) -
3522.460191 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
3522.468669 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.47783ms (max=1200ms) -
3522.468669 Get Diagnostic Response Positive response was received. -
3522.468669 Diagnostic response 0x51, 0x01 -
3522.468669 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.120.2. (In for loop)Wait for the diagnostics to start: None
3524.868669 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.120.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
3524.868669 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
3524.870111 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.44253ms (max=1000ms) -
3524.870111 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
3524.887238 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.1265ms (max=1200ms) -
3524.887238 Get Diagnostic Response Positive response was received. -
3524.887238 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
3524.887238 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.120.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
3524.887238 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 120 -
3524.887238 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 120 fail
fail
11.120.5. (In for loop)Wait for FDC10 reached TestPass limit: None
3540.887238 1 Waited for 16.000 s -
11.121. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 121)
11.121.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
3540.887238 Diagnostic request 0x11, 0x01 -
3540.888518 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.28017ms (max=1000ms) -
3540.888518 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
3540.897092 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.5738ms (max=1200ms) -
3540.897092 Get Diagnostic Response Positive response was received. -
3540.897092 Diagnostic response 0x51, 0x01 -
3540.897092 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.121.2. (In for loop)Wait for the diagnostics to start: None
3543.297092 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.121.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
3543.297092 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
3543.298487 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.39514ms (max=1000ms) -
3543.298487 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
3543.315648 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.1605ms (max=1200ms) -
3543.315648 Get Diagnostic Response Positive response was received. -
3543.315648 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
3543.315648 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.121.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
3543.315648 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 121 -
3543.315648 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 121 fail
fail
11.121.5. (In for loop)Wait for FDC10 reached TestPass limit: None
3559.315648 1 Waited for 16.000 s -
11.122. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 122)
11.122.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
3559.315648 Diagnostic request 0x11, 0x01 -
3559.317089 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.44186ms (max=1000ms) -
3559.317089 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
3559.325503 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.41381ms (max=1200ms) -
3559.325503 Get Diagnostic Response Positive response was received. -
3559.325503 Diagnostic response 0x51, 0x01 -
3559.325503 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.122.2. (In for loop)Wait for the diagnostics to start: None
3561.725503 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.122.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
3561.725503 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
3561.726949 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.4455ms (max=1000ms) -
3561.726949 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
3561.744009 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.0605ms (max=1200ms) -
3561.744009 Get Diagnostic Response Positive response was received. -
3561.744009 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
3561.744009 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.122.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
3561.744009 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 122 -
3561.744009 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 122 fail
fail
11.122.5. (In for loop)Wait for FDC10 reached TestPass limit: None
3577.744009 1 Waited for 16.000 s -
11.123. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 123)
11.123.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
3577.744009 Diagnostic request 0x11, 0x01 -
3577.745428 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.41856ms (max=1000ms) -
3577.745428 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
3577.753856 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.42781ms (max=1200ms) -
3577.753856 Get Diagnostic Response Positive response was received. -
3577.753856 Diagnostic response 0x51, 0x01 -
3577.753856 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.123.2. (In for loop)Wait for the diagnostics to start: None
3580.153856 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.123.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
3580.153856 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
3580.155286 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.43033ms (max=1000ms) -
3580.155286 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
3580.172426 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.1405ms (max=1200ms) -
3580.172426 Get Diagnostic Response Positive response was received. -
3580.172426 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
3580.172426 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.123.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
3580.172426 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 123 -
3580.172426 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 123 fail
fail
11.123.5. (In for loop)Wait for FDC10 reached TestPass limit: None
3596.172426 1 Waited for 16.000 s -
11.124. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 124)
11.124.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
3596.172426 Diagnostic request 0x11, 0x01 -
3596.173906 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.47911ms (max=1000ms) -
3596.173906 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
3596.182279 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.3738ms (max=1200ms) -
3596.182279 Get Diagnostic Response Positive response was received. -
3596.182279 Diagnostic response 0x51, 0x01 -
3596.182279 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.124.2. (In for loop)Wait for the diagnostics to start: None
3598.582279 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.124.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
3598.582279 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
3598.583822 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.54284ms (max=1000ms) -
3598.583822 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
3598.600805 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.9825ms (max=1200ms) -
3598.600805 Get Diagnostic Response Positive response was received. -
3598.600805 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
3598.600805 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.124.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
3598.600805 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 124 -
3598.600805 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 124 fail
fail
11.124.5. (In for loop)Wait for FDC10 reached TestPass limit: None
3614.600805 1 Waited for 16.000 s -
11.125. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 125)
11.125.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
3614.600805 Diagnostic request 0x11, 0x01 -
3614.602235 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.43069ms (max=1000ms) -
3614.602235 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
3614.610655 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.41983ms (max=1200ms) -
3614.610655 Get Diagnostic Response Positive response was received. -
3614.610655 Diagnostic response 0x51, 0x01 -
3614.610655 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.125.2. (In for loop)Wait for the diagnostics to start: None
3617.010655 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.125.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
3617.010655 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
3617.012144 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.48875ms (max=1000ms) -
3617.012144 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
3617.029228 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.0845ms (max=1200ms) -
3617.029228 Get Diagnostic Response Positive response was received. -
3617.029228 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
3617.029228 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.125.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
3617.029228 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 125 -
3617.029228 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 125 fail
fail
11.125.5. (In for loop)Wait for FDC10 reached TestPass limit: None
3633.029228 1 Waited for 16.000 s -
11.126. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 126)
11.126.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
3633.029228 Diagnostic request 0x11, 0x01 -
3633.030500 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.27192ms (max=1000ms) -
3633.030500 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
3633.039080 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.57983ms (max=1200ms) -
3633.039080 Get Diagnostic Response Positive response was received. -
3633.039080 Diagnostic response 0x51, 0x01 -
3633.039080 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.126.2. (In for loop)Wait for the diagnostics to start: None
3635.439080 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.126.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
3635.439080 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
3635.440585 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.5045ms (max=1000ms) -
3635.440585 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
3635.457591 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.0065ms (max=1200ms) -
3635.457591 Get Diagnostic Response Positive response was received. -
3635.457591 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
3635.457591 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.126.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
3635.457591 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 126 -
3635.457591 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 126 fail
fail
11.126.5. (In for loop)Wait for FDC10 reached TestPass limit: None
3651.457591 1 Waited for 16.000 s -
11.127. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 127)
11.127.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
3651.457591 Diagnostic request 0x11, 0x01 -
3651.458957 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.36561ms (max=1000ms) -
3651.458957 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
3651.467445 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.48781ms (max=1200ms) -
3651.467445 Get Diagnostic Response Positive response was received. -
3651.467445 Diagnostic response 0x51, 0x01 -
3651.467445 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.127.2. (In for loop)Wait for the diagnostics to start: None
3653.867445 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.127.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
3653.867445 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
3653.869081 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.63636ms (max=1000ms) -
3653.869081 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
3653.886087 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.0065ms (max=1200ms) -
3653.886087 Get Diagnostic Response Positive response was received. -
3653.886087 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
3653.886087 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.127.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
3653.886087 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 127 -
3653.886087 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 127 fail
fail
11.127.5. (In for loop)Wait for FDC10 reached TestPass limit: None
3669.886087 1 Waited for 16.000 s -
11.128. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 128)
11.128.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
3669.886087 Diagnostic request 0x11, 0x01 -
3669.887384 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.29606ms (max=1000ms) -
3669.887384 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
3669.895941 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.5578ms (max=1200ms) -
3669.895941 Get Diagnostic Response Positive response was received. -
3669.895941 Diagnostic response 0x51, 0x01 -
3669.895941 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.128.2. (In for loop)Wait for the diagnostics to start: None
3672.295941 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.128.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
3672.295941 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
3672.297383 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.4415ms (max=1000ms) -
3672.297383 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
3672.314567 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.1845ms (max=1200ms) -
3672.314567 Get Diagnostic Response Positive response was received. -
3672.314567 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
3672.314567 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.128.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
3672.314567 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 128 -
3672.314567 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 128 fail
fail
11.128.5. (In for loop)Wait for FDC10 reached TestPass limit: None
3688.314567 1 Waited for 16.000 s -
11.129. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 129)
11.129.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
3688.314567 Diagnostic request 0x11, 0x01 -
3688.316036 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.46884ms (max=1000ms) -
3688.316036 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
3688.324420 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.3838ms (max=1200ms) -
3688.324420 Get Diagnostic Response Positive response was received. -
3688.324420 Diagnostic response 0x51, 0x01 -
3688.324420 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.129.2. (In for loop)Wait for the diagnostics to start: None
3690.724420 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.129.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
3690.724420 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
3690.725918 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.49778ms (max=1000ms) -
3690.725918 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
3690.743038 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.1205ms (max=1200ms) -
3690.743038 Get Diagnostic Response Positive response was received. -
3690.743038 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
3690.743038 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.129.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
3690.743038 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 129 -
3690.743038 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 129 fail
fail
11.129.5. (In for loop)Wait for FDC10 reached TestPass limit: None
3706.743038 1 Waited for 16.000 s -
11.130. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 130)
11.130.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
3706.743038 Diagnostic request 0x11, 0x01 -
3706.744391 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.35305ms (max=1000ms) -
3706.744391 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
3706.752897 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.50583ms (max=1200ms) -
3706.752897 Get Diagnostic Response Positive response was received. -
3706.752897 Diagnostic response 0x51, 0x01 -
3706.752897 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.130.2. (In for loop)Wait for the diagnostics to start: None
3709.152897 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.130.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
3709.152897 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
3709.154294 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.39691ms (max=1000ms) -
3709.154294 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
3709.171390 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.0965ms (max=1200ms) -
3709.171390 Get Diagnostic Response Positive response was received. -
3709.171390 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
3709.171390 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.130.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
3709.171390 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 130 -
3709.171390 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 130 fail
fail
11.130.5. (In for loop)Wait for FDC10 reached TestPass limit: None
3725.171390 1 Waited for 16.000 s -
11.131. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 131)
11.131.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
3725.171390 Diagnostic request 0x11, 0x01 -
3725.172894 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.50345ms (max=1000ms) -
3725.172894 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
3725.181244 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.3498ms (max=1200ms) -
3725.181244 Get Diagnostic Response Positive response was received. -
3725.181244 Diagnostic response 0x51, 0x01 -
3725.181244 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.131.2. (In for loop)Wait for the diagnostics to start: None
3727.581244 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.131.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
3727.581244 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
3727.582914 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.67006ms (max=1000ms) -
3727.582914 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
3727.599796 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.8825ms (max=1200ms) -
3727.599796 Get Diagnostic Response Positive response was received. -
3727.599796 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
3727.599796 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.131.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
3727.599796 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 131 -
3727.599796 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 131 fail
fail
11.131.5. (In for loop)Wait for FDC10 reached TestPass limit: None
3743.599796 1 Waited for 16.000 s -
11.132. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 132)
11.132.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
3743.599796 Diagnostic request 0x11, 0x01 -
3743.601360 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.564ms (max=1000ms) -
3743.601360 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
3743.609646 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.28583ms (max=1200ms) -
3743.609646 Get Diagnostic Response Positive response was received. -
3743.609646 Diagnostic response 0x51, 0x01 -
3743.609646 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.132.2. (In for loop)Wait for the diagnostics to start: None
3746.009646 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.132.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
3746.009646 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
3746.011200 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.55378ms (max=1000ms) -
3746.011200 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
3746.028124 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.9245ms (max=1200ms) -
3746.028124 Get Diagnostic Response Positive response was received. -
3746.028124 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
3746.028124 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.132.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
3746.028124 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 132 -
3746.028124 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 132 fail
fail
11.132.5. (In for loop)Wait for FDC10 reached TestPass limit: None
3762.028124 1 Waited for 16.000 s -
11.133. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 133)
11.133.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
3762.028124 Diagnostic request 0x11, 0x01 -
3762.029438 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.31409ms (max=1000ms) -
3762.029438 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
3762.037974 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.5358ms (max=1200ms) -
3762.037974 Get Diagnostic Response Positive response was received. -
3762.037974 Diagnostic response 0x51, 0x01 -
3762.037974 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.133.2. (In for loop)Wait for the diagnostics to start: None
3764.437974 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.133.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
3764.437974 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
3764.439489 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.51456ms (max=1000ms) -
3764.439489 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
3764.456543 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.0545ms (max=1200ms) -
3764.456543 Get Diagnostic Response Positive response was received. -
3764.456543 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
3764.456543 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.133.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
3764.456543 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 133 -
3764.456543 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 133 fail
fail
11.133.5. (In for loop)Wait for FDC10 reached TestPass limit: None
3780.456543 1 Waited for 16.000 s -
11.134. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 134)
11.134.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
3780.456543 Diagnostic request 0x11, 0x01 -
3780.457966 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.42277ms (max=1000ms) -
3780.457966 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
3780.466394 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.4278ms (max=1200ms) -
3780.466394 Get Diagnostic Response Positive response was received. -
3780.466394 Diagnostic response 0x51, 0x01 -
3780.466394 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.134.2. (In for loop)Wait for the diagnostics to start: None
3782.866394 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.134.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
3782.866394 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
3782.867854 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.45984ms (max=1000ms) -
3782.867854 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
3782.885064 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.2105ms (max=1200ms) -
3782.885064 Get Diagnostic Response Positive response was received. -
3782.885064 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
3782.885064 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.134.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
3782.885064 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 134 -
3782.885064 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 134 fail
fail
11.134.5. (In for loop)Wait for FDC10 reached TestPass limit: None
3798.885064 1 Waited for 16.000 s -
11.135. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 135)
11.135.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
3798.885064 Diagnostic request 0x11, 0x01 -
3798.886560 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.49566ms (max=1000ms) -
3798.886560 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
3798.894918 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.35781ms (max=1200ms) -
3798.894918 Get Diagnostic Response Positive response was received. -
3798.894918 Diagnostic response 0x51, 0x01 -
3798.894918 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.135.2. (In for loop)Wait for the diagnostics to start: None
3801.294918 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.135.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
3801.294918 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
3801.296390 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.47273ms (max=1000ms) -
3801.296390 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
3801.313549 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.1585ms (max=1200ms) -
3801.313549 Get Diagnostic Response Positive response was received. -
3801.313549 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
3801.313549 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.135.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
3801.313549 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 135 -
3801.313549 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 135 fail
fail
11.135.5. (In for loop)Wait for FDC10 reached TestPass limit: None
3817.313549 1 Waited for 16.000 s -
11.136. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 136)
11.136.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
3817.313549 Diagnostic request 0x11, 0x01 -
3817.315060 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.5108ms (max=1000ms) -
3817.315060 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
3817.323403 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.34381ms (max=1200ms) -
3817.323403 Get Diagnostic Response Positive response was received. -
3817.323403 Diagnostic response 0x51, 0x01 -
3817.323403 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.136.2. (In for loop)Wait for the diagnostics to start: None
3819.723403 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.136.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
3819.723403 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
3819.724947 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.54356ms (max=1000ms) -
3819.724947 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
3819.741897 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.9505ms (max=1200ms) -
3819.741897 Get Diagnostic Response Positive response was received. -
3819.741897 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
3819.741897 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.136.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
3819.741897 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 136 -
3819.741897 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 136 fail
fail
11.136.5. (In for loop)Wait for FDC10 reached TestPass limit: None
3835.741897 1 Waited for 16.000 s -
11.137. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 137)
11.137.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
3835.741897 Diagnostic request 0x11, 0x01 -
3835.743325 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.42766ms (max=1000ms) -
3835.743325 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
3835.751747 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.42181ms (max=1200ms) -
3835.751747 Get Diagnostic Response Positive response was received. -
3835.751747 Diagnostic response 0x51, 0x01 -
3835.751747 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.137.2. (In for loop)Wait for the diagnostics to start: None
3838.151747 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.137.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
3838.151747 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
3838.153235 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.48777ms (max=1000ms) -
3838.153235 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
3838.170325 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.0905ms (max=1200ms) -
3838.170325 Get Diagnostic Response Positive response was received. -
3838.170325 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
3838.170325 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.137.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
3838.170325 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 137 -
3838.170325 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 137 fail
fail
11.137.5. (In for loop)Wait for FDC10 reached TestPass limit: None
3854.170325 1 Waited for 16.000 s -
11.138. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 138)
11.138.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
3854.170325 Diagnostic request 0x11, 0x01 -
3854.171825 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.49998ms (max=1000ms) -
3854.171825 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
3854.180175 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.34983ms (max=1200ms) -
3854.180175 Get Diagnostic Response Positive response was received. -
3854.180175 Diagnostic response 0x51, 0x01 -
3854.180175 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.138.2. (In for loop)Wait for the diagnostics to start: None
3856.580175 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.138.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
3856.580175 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
3856.581573 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.39755ms (max=1000ms) -
3856.581573 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
3856.598741 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.1685ms (max=1200ms) -
3856.598741 Get Diagnostic Response Positive response was received. -
3856.598741 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
3856.598741 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.138.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
3856.598741 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 138 -
3856.598741 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 138 fail
fail
11.138.5. (In for loop)Wait for FDC10 reached TestPass limit: None
3872.598741 1 Waited for 16.000 s -
11.139. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 139)
11.139.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
3872.598741 Diagnostic request 0x11, 0x01 -
3872.600160 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.41891ms (max=1000ms) -
3872.600160 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
3872.608598 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.43819ms (max=1200ms) -
3872.608598 Get Diagnostic Response Positive response was received. -
3872.608598 Diagnostic response 0x51, 0x01 -
3872.608598 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.139.2. (In for loop)Wait for the diagnostics to start: None
3875.008598 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.139.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
3875.008598 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
3875.010133 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.53452ms (max=1000ms) -
3875.010133 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
3875.027167 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.0345ms (max=1200ms) -
3875.027167 Get Diagnostic Response Positive response was received. -
3875.027167 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
3875.027167 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.139.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
3875.027167 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 139 -
3875.027167 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 139 fail
fail
11.139.5. (In for loop)Wait for FDC10 reached TestPass limit: None
3891.027167 1 Waited for 16.000 s -
11.140. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 140)
11.140.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
3891.027167 Diagnostic request 0x11, 0x01 -
3891.028431 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.26419ms (max=1000ms) -
3891.028431 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
3891.037019 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.5878ms (max=1200ms) -
3891.037019 Get Diagnostic Response Positive response was received. -
3891.037019 Diagnostic response 0x51, 0x01 -
3891.037019 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.140.2. (In for loop)Wait for the diagnostics to start: None
3893.437019 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.140.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
3893.437019 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
3893.438502 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.48339ms (max=1000ms) -
3893.438502 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
3893.455659 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.1565ms (max=1200ms) -
3893.455659 Get Diagnostic Response Positive response was received. -
3893.455659 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
3893.455659 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.140.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
3893.455659 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 140 -
3893.455659 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 140 fail
fail
11.140.5. (In for loop)Wait for FDC10 reached TestPass limit: None
3909.455659 1 Waited for 16.000 s -
11.141. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 141)
11.141.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
3909.455659 Diagnostic request 0x11, 0x01 -
3909.457065 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.40623ms (max=1000ms) -
3909.457065 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
3909.465511 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.4458ms (max=1200ms) -
3909.465511 Get Diagnostic Response Positive response was received. -
3909.465511 Diagnostic response 0x51, 0x01 -
3909.465511 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.141.2. (In for loop)Wait for the diagnostics to start: None
3911.865511 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.141.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
3911.865511 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
3911.866975 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.46449ms (max=1000ms) -
3911.866975 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
3911.884062 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.0865ms (max=1200ms) -
3911.884062 Get Diagnostic Response Positive response was received. -
3911.884062 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
3911.884062 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.141.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
3911.884062 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 141 -
3911.884062 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 141 fail
fail
11.141.5. (In for loop)Wait for FDC10 reached TestPass limit: None
3927.884062 1 Waited for 16.000 s -
11.142. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 142)
11.142.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
3927.884062 Diagnostic request 0x11, 0x01 -
3927.885409 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.34744ms (max=1000ms) -
3927.885409 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
3927.893913 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.5038ms (max=1200ms) -
3927.893913 Get Diagnostic Response Positive response was received. -
3927.893913 Diagnostic response 0x51, 0x01 -
3927.893913 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.142.2. (In for loop)Wait for the diagnostics to start: None
3930.293913 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.142.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
3930.293913 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
3930.295376 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.46339ms (max=1000ms) -
3930.295376 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
3930.312313 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.9365ms (max=1200ms) -
3930.312313 Get Diagnostic Response Positive response was received. -
3930.312313 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
3930.312313 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.142.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
3930.312313 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 142 -
3930.312313 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 142 fail
fail
11.142.5. (In for loop)Wait for FDC10 reached TestPass limit: None
3946.312313 1 Waited for 16.000 s -
11.143. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 143)
11.143.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
3946.312313 Diagnostic request 0x11, 0x01 -
3946.313822 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.50853ms (max=1000ms) -
3946.313822 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
3946.322165 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.34383ms (max=1200ms) -
3946.322165 Get Diagnostic Response Positive response was received. -
3946.322165 Diagnostic response 0x51, 0x01 -
3946.322165 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.143.2. (In for loop)Wait for the diagnostics to start: None
3948.722165 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.143.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
3948.722165 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
3948.723537 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.3717ms (max=1000ms) -
3948.723537 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
3948.740668 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.1305ms (max=1200ms) -
3948.740668 Get Diagnostic Response Positive response was received. -
3948.740668 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
3948.740668 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.143.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
3948.740668 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 143 -
3948.740668 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 143 fail
fail
11.143.5. (In for loop)Wait for FDC10 reached TestPass limit: None
3964.740668 1 Waited for 16.000 s -
11.144. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 144)
11.144.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
3964.740668 Diagnostic request 0x11, 0x01 -
3964.742060 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.39278ms (max=1000ms) -
3964.742060 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
3964.750518 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.45783ms (max=1200ms) -
3964.750518 Get Diagnostic Response Positive response was received. -
3964.750518 Diagnostic response 0x51, 0x01 -
3964.750518 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.144.2. (In for loop)Wait for the diagnostics to start: None
3967.150518 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.144.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
3967.150518 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
3967.152045 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.52706ms (max=1000ms) -
3967.152045 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
3967.168994 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.9485ms (max=1200ms) -
3967.168994 Get Diagnostic Response Positive response was received. -
3967.168994 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
3967.168994 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.144.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
3967.168994 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 144 -
3967.168994 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 144 fail
fail
11.144.5. (In for loop)Wait for FDC10 reached TestPass limit: None
3983.168994 1 Waited for 16.000 s -
11.145. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 145)
11.145.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
3983.168994 Diagnostic request 0x11, 0x01 -
3983.170263 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.26975ms (max=1000ms) -
3983.170263 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
3983.178847 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.58383ms (max=1200ms) -
3983.178847 Get Diagnostic Response Positive response was received. -
3983.178847 Diagnostic response 0x51, 0x01 -
3983.178847 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.145.2. (In for loop)Wait for the diagnostics to start: None
3985.578847 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.145.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
3985.578847 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
3985.580327 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.47966ms (max=1000ms) -
3985.580327 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
3985.597459 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.1325ms (max=1200ms) -
3985.597459 Get Diagnostic Response Positive response was received. -
3985.597459 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
3985.597459 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.145.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
3985.597459 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 145 -
3985.597459 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 145 fail
fail
11.145.5. (In for loop)Wait for FDC10 reached TestPass limit: None
4001.597459 1 Waited for 16.000 s -
11.146. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 146)
11.146.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
4001.597459 Diagnostic request 0x11, 0x01 -
4001.598791 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.3315ms (max=1000ms) -
4001.598791 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
4001.607311 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.5202ms (max=1200ms) -
4001.607311 Get Diagnostic Response Positive response was received. -
4001.607311 Diagnostic response 0x51, 0x01 -
4001.607311 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.146.2. (In for loop)Wait for the diagnostics to start: None
4004.007311 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.146.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
4004.007311 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
4004.008910 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.5988ms (max=1000ms) -
4004.008910 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
4004.025848 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.9385ms (max=1200ms) -
4004.025848 Get Diagnostic Response Positive response was received. -
4004.025848 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
4004.025848 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.146.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
4004.025848 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 146 -
4004.025848 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 146 fail
fail
11.146.5. (In for loop)Wait for FDC10 reached TestPass limit: None
4020.025848 1 Waited for 16.000 s -
11.147. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 147)
11.147.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
4020.025848 Diagnostic request 0x11, 0x01 -
4020.027359 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.51047ms (max=1000ms) -
4020.027359 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
4020.035697 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.3378ms (max=1200ms) -
4020.035697 Get Diagnostic Response Positive response was received. -
4020.035697 Diagnostic response 0x51, 0x01 -
4020.035697 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.147.2. (In for loop)Wait for the diagnostics to start: None
4022.435697 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.147.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
4022.435697 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
4022.437120 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.42294ms (max=1000ms) -
4022.437120 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
4022.454218 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.0985ms (max=1200ms) -
4022.454218 Get Diagnostic Response Positive response was received. -
4022.454218 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
4022.454218 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.147.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
4022.454218 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 147 -
4022.454218 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 147 fail
fail
11.147.5. (In for loop)Wait for FDC10 reached TestPass limit: None
4038.454218 1 Waited for 16.000 s -
11.148. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 148)
11.148.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
4038.454218 Diagnostic request 0x11, 0x01 -
4038.455533 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.31526ms (max=1000ms) -
4038.455533 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
4038.464073 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.5398ms (max=1200ms) -
4038.464073 Get Diagnostic Response Positive response was received. -
4038.464073 Diagnostic response 0x51, 0x01 -
4038.464073 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.148.2. (In for loop)Wait for the diagnostics to start: None
4040.864073 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.148.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
4040.864073 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
4040.865508 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.43483ms (max=1000ms) -
4040.865508 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
4040.882550 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.0425ms (max=1200ms) -
4040.882550 Get Diagnostic Response Positive response was received. -
4040.882550 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
4040.882550 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.148.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
4040.882550 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 148 -
4040.882550 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 148 fail
fail
11.148.5. (In for loop)Wait for FDC10 reached TestPass limit: None
4056.882550 1 Waited for 16.000 s -
11.149. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 149)
11.149.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
4056.882550 Diagnostic request 0x11, 0x01 -
4056.883986 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.4353ms (max=1000ms) -
4056.883986 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
4056.892404 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.41783ms (max=1200ms) -
4056.892404 Get Diagnostic Response Positive response was received. -
4056.892404 Diagnostic response 0x51, 0x01 -
4056.892404 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.149.2. (In for loop)Wait for the diagnostics to start: None
4059.292404 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.149.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
4059.292404 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
4059.293889 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.4858ms (max=1000ms) -
4059.293889 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
4059.310788 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.8985ms (max=1200ms) -
4059.310788 Get Diagnostic Response Positive response was received. -
4059.310788 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
4059.310788 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.149.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
4059.310788 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 149 -
4059.310788 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 149 fail
fail
11.149.5. (In for loop)Wait for FDC10 reached TestPass limit: None
4075.310788 1 Waited for 16.000 s -
11.150. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 150)
11.150.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
4075.310788 Diagnostic request 0x11, 0x01 -
4075.312207 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.41928ms (max=1000ms) -
4075.312207 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
4075.320643 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.43581ms (max=1200ms) -
4075.320643 Get Diagnostic Response Positive response was received. -
4075.320643 Diagnostic response 0x51, 0x01 -
4075.320643 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.150.2. (In for loop)Wait for the diagnostics to start: None
4077.720643 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.150.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
4077.720643 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
4077.722131 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.48803ms (max=1000ms) -
4077.722131 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
4077.739141 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.0105ms (max=1200ms) -
4077.739141 Get Diagnostic Response Positive response was received. -
4077.739141 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
4077.739141 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.150.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
4077.739141 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 150 -
4077.739141 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 150 fail
fail
11.150.5. (In for loop)Wait for FDC10 reached TestPass limit: None
4093.739141 1 Waited for 16.000 s -
11.151. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 151)
11.151.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
4093.739141 Diagnostic request 0x11, 0x01 -
4093.740400 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.2582ms (max=1000ms) -
4093.740400 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
4093.748994 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.59381ms (max=1200ms) -
4093.748994 Get Diagnostic Response Positive response was received. -
4093.748994 Diagnostic response 0x51, 0x01 -
4093.748994 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.151.2. (In for loop)Wait for the diagnostics to start: None
4096.148994 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.151.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
4096.148994 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
4096.150516 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.52219ms (max=1000ms) -
4096.150516 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
4096.167492 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.9765ms (max=1200ms) -
4096.167492 Get Diagnostic Response Positive response was received. -
4096.167492 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
4096.167492 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.151.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
4096.167492 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 151 -
4096.167492 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 151 fail
fail
11.151.5. (In for loop)Wait for FDC10 reached TestPass limit: None
4112.167492 1 Waited for 16.000 s -
11.152. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 152)
11.152.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
4112.167492 Diagnostic request 0x11, 0x01 -
4112.168981 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.48906ms (max=1000ms) -
4112.168981 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
4112.177345 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.3638ms (max=1200ms) -
4112.177345 Get Diagnostic Response Positive response was received. -
4112.177345 Diagnostic response 0x51, 0x01 -
4112.177345 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.152.2. (In for loop)Wait for the diagnostics to start: None
4114.577345 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.152.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
4114.577345 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
4114.578871 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.52558ms (max=1000ms) -
4114.578871 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
4114.595873 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.0025ms (max=1200ms) -
4114.595873 Get Diagnostic Response Positive response was received. -
4114.595873 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
4114.595873 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.152.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
4114.595873 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 152 -
4114.595873 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 152 fail
fail
11.152.5. (In for loop)Wait for FDC10 reached TestPass limit: None
4130.595873 1 Waited for 16.000 s -
11.153. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 153)
11.153.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
4130.595873 Diagnostic request 0x11, 0x01 -
4130.597313 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.44039ms (max=1000ms) -
4130.597313 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
4130.605790 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.47624ms (max=1200ms) -
4130.605790 Get Diagnostic Response Positive response was received. -
4130.605790 Diagnostic response 0x51, 0x01 -
4130.605790 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.153.2. (In for loop)Wait for the diagnostics to start: None
4133.005790 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.153.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
4133.005790 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
4133.007260 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.46983ms (max=1000ms) -
4133.007260 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
4133.024200 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.9405ms (max=1200ms) -
4133.024200 Get Diagnostic Response Positive response was received. -
4133.024200 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
4133.024200 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.153.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
4133.024200 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 153 -
4133.024200 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 153 fail
fail
11.153.5. (In for loop)Wait for FDC10 reached TestPass limit: None
4149.024200 1 Waited for 16.000 s -
11.154. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 154)
11.154.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
4149.024200 Diagnostic request 0x11, 0x01 -
4149.025466 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.26642ms (max=1000ms) -
4149.025466 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
4149.034052 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.58584ms (max=1200ms) -
4149.034052 Get Diagnostic Response Positive response was received. -
4149.034052 Diagnostic response 0x51, 0x01 -
4149.034052 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.154.2. (In for loop)Wait for the diagnostics to start: None
4151.434052 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.154.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
4151.434052 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
4151.435430 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.37784ms (max=1000ms) -
4151.435430 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
4151.452597 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.1665ms (max=1200ms) -
4151.452597 Get Diagnostic Response Positive response was received. -
4151.452597 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
4151.452597 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.154.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
4151.452597 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 154 -
4151.452597 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 154 fail
fail
11.154.5. (In for loop)Wait for FDC10 reached TestPass limit: None
4167.452597 1 Waited for 16.000 s -
11.155. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 155)
11.155.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
4167.452597 Diagnostic request 0x11, 0x01 -
4167.454005 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.40811ms (max=1000ms) -
4167.454005 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
4167.462452 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.4478ms (max=1200ms) -
4167.462452 Get Diagnostic Response Positive response was received. -
4167.462452 Diagnostic response 0x51, 0x01 -
4167.462452 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.155.2. (In for loop)Wait for the diagnostics to start: None
4169.862452 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.155.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
4169.862452 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
4169.863886 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.43378ms (max=1000ms) -
4169.863886 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
4169.880967 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.0805ms (max=1200ms) -
4169.880967 Get Diagnostic Response Positive response was received. -
4169.880967 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
4169.880967 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.155.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
4169.880967 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 155 -
4169.880967 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 155 fail
fail
11.155.5. (In for loop)Wait for FDC10 reached TestPass limit: None
4185.880967 1 Waited for 16.000 s -
11.156. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 156)
11.156.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
4185.880967 Diagnostic request 0x11, 0x01 -
4185.882336 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.36938ms (max=1000ms) -
4185.882336 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
4185.890818 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.48181ms (max=1200ms) -
4185.890818 Get Diagnostic Response Positive response was received. -
4185.890818 Diagnostic response 0x51, 0x01 -
4185.890818 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.156.2. (In for loop)Wait for the diagnostics to start: None
4188.290818 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.156.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
4188.290818 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
4188.292361 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.5432ms (max=1000ms) -
4188.292361 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
4188.309354 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.9925ms (max=1200ms) -
4188.309354 Get Diagnostic Response Positive response was received. -
4188.309354 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
4188.309354 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.156.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
4188.309354 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 156 -
4188.309354 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 156 fail
fail
11.156.5. (In for loop)Wait for FDC10 reached TestPass limit: None
4204.309354 1 Waited for 16.000 s -
11.157. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 157)
11.157.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
4204.309354 Diagnostic request 0x11, 0x01 -
4204.310909 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.55523ms (max=1000ms) -
4204.310909 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
4204.319207 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.2978ms (max=1200ms) -
4204.319207 Get Diagnostic Response Positive response was received. -
4204.319207 Diagnostic response 0x51, 0x01 -
4204.319207 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.157.2. (In for loop)Wait for the diagnostics to start: None
4206.719207 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.157.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
4206.719207 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
4206.720545 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.33845ms (max=1000ms) -
4206.720545 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
4206.737730 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.1845ms (max=1200ms) -
4206.737730 Get Diagnostic Response Positive response was received. -
4206.737730 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
4206.737730 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.157.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
4206.737730 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 157 -
4206.737730 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 157 fail
fail
11.157.5. (In for loop)Wait for FDC10 reached TestPass limit: None
4222.737730 1 Waited for 16.000 s -
11.158. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 158)
11.158.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
4222.737730 Diagnostic request 0x11, 0x01 -
4222.739155 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.42553ms (max=1000ms) -
4222.739155 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
4222.747585 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.4298ms (max=1200ms) -
4222.747585 Get Diagnostic Response Positive response was received. -
4222.747585 Diagnostic response 0x51, 0x01 -
4222.747585 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.158.2. (In for loop)Wait for the diagnostics to start: None
4225.147585 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.158.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
4225.147585 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
4225.149048 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.46308ms (max=1000ms) -
4225.149048 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
4225.166083 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.0345ms (max=1200ms) -
4225.166083 Get Diagnostic Response Positive response was received. -
4225.166083 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
4225.166083 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.158.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
4225.166083 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 158 -
4225.166083 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 158 fail
fail
11.158.5. (In for loop)Wait for FDC10 reached TestPass limit: None
4241.166083 1 Waited for 16.000 s -
11.159. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 159)
11.159.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
4241.166083 Diagnostic request 0x11, 0x01 -
4241.167359 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.27617ms (max=1000ms) -
4241.167359 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
4241.175937 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.57783ms (max=1200ms) -
4241.175937 Get Diagnostic Response Positive response was received. -
4241.175937 Diagnostic response 0x51, 0x01 -
4241.175937 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.159.2. (In for loop)Wait for the diagnostics to start: None
4243.575937 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.159.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
4243.575937 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
4243.577411 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.47412ms (max=1000ms) -
4243.577411 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
4243.594433 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.0225ms (max=1200ms) -
4243.594433 Get Diagnostic Response Positive response was received. -
4243.594433 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
4243.594433 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.159.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
4243.594433 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 159 -
4243.594433 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 159 fail
fail
11.159.5. (In for loop)Wait for FDC10 reached TestPass limit: None
4259.594433 1 Waited for 16.000 s -
11.160. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 160)
11.160.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
4259.594433 Diagnostic request 0x11, 0x01 -
4259.595898 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.46441ms (max=1000ms) -
4259.595898 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
4259.604350 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.45225ms (max=1200ms) -
4259.604350 Get Diagnostic Response Positive response was received. -
4259.604350 Diagnostic response 0x51, 0x01 -
4259.604350 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.160.2. (In for loop)Wait for the diagnostics to start: None
4262.004350 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.160.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
4262.004350 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
4262.005957 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.60708ms (max=1000ms) -
4262.005957 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
4262.022807 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.8505ms (max=1200ms) -
4262.022807 Get Diagnostic Response Positive response was received. -
4262.022807 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
4262.022807 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.160.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
4262.022807 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 160 -
4262.022807 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 160 fail
fail
11.160.5. (In for loop)Wait for FDC10 reached TestPass limit: None
4278.022807 1 Waited for 16.000 s -
11.161. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 161)
11.161.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
4278.022807 Diagnostic request 0x11, 0x01 -
4278.024139 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.33167ms (max=1000ms) -
4278.024139 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
4278.032665 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.52583ms (max=1200ms) -
4278.032665 Get Diagnostic Response Positive response was received. -
4278.032665 Diagnostic response 0x51, 0x01 -
4278.032665 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.161.2. (In for loop)Wait for the diagnostics to start: None
4280.432665 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.161.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
4280.432665 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
4280.434152 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.48755ms (max=1000ms) -
4280.434152 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
4280.451113 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.9605ms (max=1200ms) -
4280.451113 Get Diagnostic Response Positive response was received. -
4280.451113 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
4280.451113 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.161.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
4280.451113 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 161 -
4280.451113 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 161 fail
fail
11.161.5. (In for loop)Wait for FDC10 reached TestPass limit: None
4296.451113 1 Waited for 16.000 s -
11.162. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 162)
11.162.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
4296.451113 Diagnostic request 0x11, 0x01 -
4296.452426 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.31308ms (max=1000ms) -
4296.452426 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
4296.460966 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.5398ms (max=1200ms) -
4296.460966 Get Diagnostic Response Positive response was received. -
4296.460966 Diagnostic response 0x51, 0x01 -
4296.460966 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.162.2. (In for loop)Wait for the diagnostics to start: None
4298.860966 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.162.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
4298.860966 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
4298.862398 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.43267ms (max=1000ms) -
4298.862398 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
4298.879495 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.0965ms (max=1200ms) -
4298.879495 Get Diagnostic Response Positive response was received. -
4298.879495 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
4298.879495 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.162.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
4298.879495 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 162 -
4298.879495 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 162 fail
fail
11.162.5. (In for loop)Wait for FDC10 reached TestPass limit: None
4314.879495 1 Waited for 16.000 s -
11.163. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 163)
11.163.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
4314.879495 Diagnostic request 0x11, 0x01 -
4314.881024 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.52925ms (max=1000ms) -
4314.881024 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
4314.889348 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.3238ms (max=1200ms) -
4314.889348 Get Diagnostic Response Positive response was received. -
4314.889348 Diagnostic response 0x51, 0x01 -
4314.889348 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.163.2. (In for loop)Wait for the diagnostics to start: None
4317.289348 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.163.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
4317.289348 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
4317.291184 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.83563ms (max=1000ms) -
4317.291184 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
4317.307840 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.6565ms (max=1200ms) -
4317.307840 Get Diagnostic Response Positive response was received. -
4317.307840 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
4317.307840 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.163.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
4317.307840 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 163 -
4317.307840 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 163 fail
fail
11.163.5. (In for loop)Wait for FDC10 reached TestPass limit: None
4333.307840 1 Waited for 16.000 s -
11.164. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 164)
11.164.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
4333.307840 Diagnostic request 0x11, 0x01 -
4333.309159 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.31923ms (max=1000ms) -
4333.309159 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
4333.317697 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.5378ms (max=1200ms) -
4333.317697 Get Diagnostic Response Positive response was received. -
4333.317697 Diagnostic response 0x51, 0x01 -
4333.317697 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.164.2. (In for loop)Wait for the diagnostics to start: None
4335.717697 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.164.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
4335.717697 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
4335.719229 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.53194ms (max=1000ms) -
4335.719229 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
4335.736276 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.0465ms (max=1200ms) -
4335.736276 Get Diagnostic Response Positive response was received. -
4335.736276 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
4335.736276 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.164.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
4335.736276 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 164 -
4335.736276 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 164 fail
fail
11.164.5. (In for loop)Wait for FDC10 reached TestPass limit: None
4351.736276 1 Waited for 16.000 s -
11.165. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 165)
11.165.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
4351.736276 Diagnostic request 0x11, 0x01 -
4351.737716 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.44047ms (max=1000ms) -
4351.737716 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
4351.746128 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.4118ms (max=1200ms) -
4351.746128 Get Diagnostic Response Positive response was received. -
4351.746128 Diagnostic response 0x51, 0x01 -
4351.746128 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.165.2. (In for loop)Wait for the diagnostics to start: None
4354.146128 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.165.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
4354.146128 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
4354.147483 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.35475ms (max=1000ms) -
4354.147483 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
4354.164659 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.1765ms (max=1200ms) -
4354.164659 Get Diagnostic Response Positive response was received. -
4354.164659 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
4354.164659 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.165.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
4354.164659 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 165 -
4354.164659 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 165 fail
fail
11.165.5. (In for loop)Wait for FDC10 reached TestPass limit: None
4370.164659 1 Waited for 16.000 s -
11.166. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 166)
11.166.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
4370.164659 Diagnostic request 0x11, 0x01 -
4370.166069 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.41044ms (max=1000ms) -
4370.166069 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
4370.174507 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.43781ms (max=1200ms) -
4370.174507 Get Diagnostic Response Positive response was received. -
4370.174507 Diagnostic response 0x51, 0x01 -
4370.174507 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.166.2. (In for loop)Wait for the diagnostics to start: None
4372.574507 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.166.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
4372.574507 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
4372.576037 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.52988ms (max=1000ms) -
4372.576037 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
4372.592936 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.8985ms (max=1200ms) -
4372.592936 Get Diagnostic Response Positive response was received. -
4372.592936 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
4372.592936 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.166.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
4372.592936 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 166 -
4372.592936 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 166 fail
fail
11.166.5. (In for loop)Wait for FDC10 reached TestPass limit: None
4388.592936 1 Waited for 16.000 s -
11.167. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 167)
11.167.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
4388.592936 Diagnostic request 0x11, 0x01 -
4388.594288 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.35286ms (max=1000ms) -
4388.594288 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
4388.602849 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.56025ms (max=1200ms) -
4388.602849 Get Diagnostic Response Positive response was received. -
4388.602849 Diagnostic response 0x51, 0x01 -
4388.602849 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.167.2. (In for loop)Wait for the diagnostics to start: None
4391.002849 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.167.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
4391.002849 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
4391.004278 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.42884ms (max=1000ms) -
4391.004278 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
4391.021222 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.9445ms (max=1200ms) -
4391.021222 Get Diagnostic Response Positive response was received. -
4391.021222 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
4391.021222 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.167.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
4391.021222 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 167 -
4391.021222 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 167 fail
fail
11.167.5. (In for loop)Wait for FDC10 reached TestPass limit: None
4407.021222 1 Waited for 16.000 s -
11.168. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 168)
11.168.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
4407.021222 Diagnostic request 0x11, 0x01 -
4407.022517 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.29527ms (max=1000ms) -
4407.022517 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
4407.031077 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.5598ms (max=1200ms) -
4407.031077 Get Diagnostic Response Positive response was received. -
4407.031077 Diagnostic response 0x51, 0x01 -
4407.031077 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.168.2. (In for loop)Wait for the diagnostics to start: None
4409.431077 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.168.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
4409.431077 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
4409.432486 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.40933ms (max=1000ms) -
4409.432486 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
4409.449487 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.0005ms (max=1200ms) -
4409.449487 Get Diagnostic Response Positive response was received. -
4409.449487 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
4409.449487 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.168.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
4409.449487 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 168 -
4409.449487 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 168 fail
fail
11.168.5. (In for loop)Wait for FDC10 reached TestPass limit: None
4425.449487 1 Waited for 16.000 s -
11.169. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 169)
11.169.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
4425.449487 Diagnostic request 0x11, 0x01 -
4425.451034 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.54703ms (max=1000ms) -
4425.451034 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
4425.459342 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.3078ms (max=1200ms) -
4425.459342 Get Diagnostic Response Positive response was received. -
4425.459342 Diagnostic response 0x51, 0x01 -
4425.459342 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.169.2. (In for loop)Wait for the diagnostics to start: None
4427.859342 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.169.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
4427.859342 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
4427.861053 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.71134ms (max=1000ms) -
4427.861053 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
4427.877822 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.7685ms (max=1200ms) -
4427.877822 Get Diagnostic Response Positive response was received. -
4427.877822 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
4427.877822 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.169.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
4427.877822 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 169 -
4427.877822 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 169 fail
fail
11.169.5. (In for loop)Wait for FDC10 reached TestPass limit: None
4443.877822 1 Waited for 16.000 s -
11.170. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 170)
11.170.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
4443.877822 Diagnostic request 0x11, 0x01 -
4443.879246 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.42447ms (max=1000ms) -
4443.879246 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
4443.887678 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.4318ms (max=1200ms) -
4443.887678 Get Diagnostic Response Positive response was received. -
4443.887678 Diagnostic response 0x51, 0x01 -
4443.887678 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.170.2. (In for loop)Wait for the diagnostics to start: None
4446.287678 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.170.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
4446.287678 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
4446.289158 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.48005ms (max=1000ms) -
4446.289158 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
4446.306132 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.9745ms (max=1200ms) -
4446.306132 Get Diagnostic Response Positive response was received. -
4446.306132 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
4446.306132 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.170.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
4446.306132 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 170 -
4446.306132 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 170 fail
fail
11.170.5. (In for loop)Wait for FDC10 reached TestPass limit: None
4462.306132 1 Waited for 16.000 s -
11.171. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 171)
11.171.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
4462.306132 Diagnostic request 0x11, 0x01 -
4462.307390 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.25728ms (max=1000ms) -
4462.307390 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
4462.315985 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.5958ms (max=1200ms) -
4462.315985 Get Diagnostic Response Positive response was received. -
4462.315985 Diagnostic response 0x51, 0x01 -
4462.315985 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.171.2. (In for loop)Wait for the diagnostics to start: None
4464.715985 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.171.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
4464.715985 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
4464.717426 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.44056ms (max=1000ms) -
4464.717426 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
4464.734454 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.0285ms (max=1200ms) -
4464.734454 Get Diagnostic Response Positive response was received. -
4464.734454 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
4464.734454 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.171.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
4464.734454 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 171 -
4464.734454 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 171 fail
fail
11.171.5. (In for loop)Wait for FDC10 reached TestPass limit: None
4480.734454 1 Waited for 16.000 s -
11.172. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 172)
11.172.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
4480.734454 Diagnostic request 0x11, 0x01 -
4480.735916 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.46116ms (max=1000ms) -
4480.735916 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
4480.744307 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.3918ms (max=1200ms) -
4480.744307 Get Diagnostic Response Positive response was received. -
4480.744307 Diagnostic response 0x51, 0x01 -
4480.744307 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.172.2. (In for loop)Wait for the diagnostics to start: None
4483.144307 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.172.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
4483.144307 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
4483.145808 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.5005ms (max=1000ms) -
4483.145808 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
4483.162802 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.9945ms (max=1200ms) -
4483.162802 Get Diagnostic Response Positive response was received. -
4483.162802 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
4483.162802 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.172.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
4483.162802 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 172 -
4483.162802 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 172 fail
fail
11.172.5. (In for loop)Wait for FDC10 reached TestPass limit: None
4499.162802 1 Waited for 16.000 s -
11.173. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 173)
11.173.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
4499.162802 Diagnostic request 0x11, 0x01 -
4499.164116 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.31416ms (max=1000ms) -
4499.164116 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
4499.172654 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.5378ms (max=1200ms) -
4499.172654 Get Diagnostic Response Positive response was received. -
4499.172654 Diagnostic response 0x51, 0x01 -
4499.172654 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.173.2. (In for loop)Wait for the diagnostics to start: None
4501.572654 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.173.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
4501.572654 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
4501.574114 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.45978ms (max=1000ms) -
4501.574114 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
4501.591235 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.1205ms (max=1200ms) -
4501.591235 Get Diagnostic Response Positive response was received. -
4501.591235 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
4501.591235 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.173.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
4501.591235 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 173 -
4501.591235 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 173 fail
fail
11.173.5. (In for loop)Wait for FDC10 reached TestPass limit: None
4517.591235 1 Waited for 16.000 s -
11.174. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 174)
11.174.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
4517.591235 Diagnostic request 0x11, 0x01 -
4517.592551 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.31688ms (max=1000ms) -
4517.592551 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
4517.601088 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.53628ms (max=1200ms) -
4517.601088 Get Diagnostic Response Positive response was received. -
4517.601088 Diagnostic response 0x51, 0x01 -
4517.601088 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.174.2. (In for loop)Wait for the diagnostics to start: None
4520.001088 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.174.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
4520.001088 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
4520.002517 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.429ms (max=1000ms) -
4520.002517 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
4520.019427 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.9105ms (max=1200ms) -
4520.019427 Get Diagnostic Response Positive response was received. -
4520.019427 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
4520.019427 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.174.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
4520.019427 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 174 -
4520.019427 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 174 fail
fail
11.174.5. (In for loop)Wait for FDC10 reached TestPass limit: None
4536.019427 1 Waited for 16.000 s -
11.175. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 175)
11.175.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
4536.019427 Diagnostic request 0x11, 0x01 -
4536.020901 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.47367ms (max=1000ms) -
4536.020901 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
4536.029287 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.38583ms (max=1200ms) -
4536.029287 Get Diagnostic Response Positive response was received. -
4536.029287 Diagnostic response 0x51, 0x01 -
4536.029287 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.175.2. (In for loop)Wait for the diagnostics to start: None
4538.429287 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.175.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
4538.429287 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
4538.430958 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.6712ms (max=1000ms) -
4538.430958 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
4538.447648 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.6905ms (max=1200ms) -
4538.447648 Get Diagnostic Response Positive response was received. -
4538.447648 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
4538.447648 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.175.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
4538.447648 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 175 -
4538.447648 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 175 fail
fail
11.175.5. (In for loop)Wait for FDC10 reached TestPass limit: None
4554.447648 1 Waited for 16.000 s -
11.176. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 176)
11.176.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
4554.447648 Diagnostic request 0x11, 0x01 -
4554.448986 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.33758ms (max=1000ms) -
4554.448986 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
4554.457500 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.5138ms (max=1200ms) -
4554.457500 Get Diagnostic Response Positive response was received. -
4554.457500 Diagnostic response 0x51, 0x01 -
4554.457500 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.176.2. (In for loop)Wait for the diagnostics to start: None
4556.857500 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.176.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
4556.857500 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
4556.858894 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.39378ms (max=1000ms) -
4556.858894 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
4556.875998 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.1045ms (max=1200ms) -
4556.875998 Get Diagnostic Response Positive response was received. -
4556.875998 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
4556.875998 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.176.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
4556.875998 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 176 -
4556.875998 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 176 fail
fail
11.176.5. (In for loop)Wait for FDC10 reached TestPass limit: None
4572.875998 1 Waited for 16.000 s -
11.177. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 177)
11.177.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
4572.875998 Diagnostic request 0x11, 0x01 -
4572.877350 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.35238ms (max=1000ms) -
4572.877350 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
4572.885852 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.5018ms (max=1200ms) -
4572.885852 Get Diagnostic Response Positive response was received. -
4572.885852 Diagnostic response 0x51, 0x01 -
4572.885852 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.177.2. (In for loop)Wait for the diagnostics to start: None
4575.285852 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.177.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
4575.285852 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
4575.287314 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.46139ms (max=1000ms) -
4575.287314 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
4575.304264 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.9505ms (max=1200ms) -
4575.304264 Get Diagnostic Response Positive response was received. -
4575.304264 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
4575.304264 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.177.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
4575.304264 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 177 -
4575.304264 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 177 fail
fail
11.177.5. (In for loop)Wait for FDC10 reached TestPass limit: None
4591.304264 1 Waited for 16.000 s -
11.178. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 178)
11.178.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
4591.304264 Diagnostic request 0x11, 0x01 -
4591.305986 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.72141ms (max=1000ms) -
4591.305986 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
4591.314107 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.12181ms (max=1200ms) -
4591.314107 Get Diagnostic Response Positive response was received. -
4591.314107 Diagnostic response 0x51, 0x01 -
4591.314107 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.178.2. (In for loop)Wait for the diagnostics to start: None
4593.714107 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.178.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
4593.714107 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
4593.715406 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.29853ms (max=1000ms) -
4593.715406 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
4593.732482 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.0765ms (max=1200ms) -
4593.732482 Get Diagnostic Response Positive response was received. -
4593.732482 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
4593.732482 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.178.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
4593.732482 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 178 -
4593.732482 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 178 fail
fail
11.178.5. (In for loop)Wait for FDC10 reached TestPass limit: None
4609.732482 1 Waited for 16.000 s -
11.179. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 179)
11.179.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
4609.732482 Diagnostic request 0x11, 0x01 -
4609.734119 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.63691ms (max=1000ms) -
4609.734119 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
4609.742333 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.21384ms (max=1200ms) -
4609.742333 Get Diagnostic Response Positive response was received. -
4609.742333 Diagnostic response 0x51, 0x01 -
4609.742333 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.179.2. (In for loop)Wait for the diagnostics to start: None
4612.142333 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.179.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
4612.142333 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
4612.143847 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.51411ms (max=1000ms) -
4612.143847 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
4612.160842 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.9945ms (max=1200ms) -
4612.160842 Get Diagnostic Response Positive response was received. -
4612.160842 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
4612.160842 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.179.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
4612.160842 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 179 -
4612.160842 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 179 fail
fail
11.179.5. (In for loop)Wait for FDC10 reached TestPass limit: None
4628.160842 1 Waited for 16.000 s -
11.180. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 180)
11.180.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
4628.160842 Diagnostic request 0x11, 0x01 -
4628.162241 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.39923ms (max=1000ms) -
4628.162241 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
4628.170693 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.45183ms (max=1200ms) -
4628.170693 Get Diagnostic Response Positive response was received. -
4628.170693 Diagnostic response 0x51, 0x01 -
4628.170693 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.180.2. (In for loop)Wait for the diagnostics to start: None
4630.570693 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.180.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
4630.570693 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
4630.572185 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.49228ms (max=1000ms) -
4630.572185 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
4630.589172 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.9865ms (max=1200ms) -
4630.589172 Get Diagnostic Response Positive response was received. -
4630.589172 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
4630.589172 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.180.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
4630.589172 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 180 -
4630.589172 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 180 fail
fail
11.180.5. (In for loop)Wait for FDC10 reached TestPass limit: None
4646.589172 1 Waited for 16.000 s -
11.181. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 181)
11.181.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
4646.589172 Diagnostic request 0x11, 0x01 -
4646.590430 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.25877ms (max=1000ms) -
4646.590430 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
4646.599022 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.5918ms (max=1200ms) -
4646.599022 Get Diagnostic Response Positive response was received. -
4646.599022 Diagnostic response 0x51, 0x01 -
4646.599022 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.181.2. (In for loop)Wait for the diagnostics to start: None
4648.999022 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.181.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
4648.999022 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
4649.000453 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.43053ms (max=1000ms) -
4649.000453 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
4649.017480 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.0269ms (max=1200ms) -
4649.017480 Get Diagnostic Response Positive response was received. -
4649.017480 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
4649.017480 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.181.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
4649.017480 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 181 -
4649.017480 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 181 fail
fail
11.181.5. (In for loop)Wait for FDC10 reached TestPass limit: None
4665.017480 1 Waited for 16.000 s -
11.182. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 182)
11.182.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
4665.017480 Diagnostic request 0x11, 0x01 -
4665.018827 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.34792ms (max=1000ms) -
4665.018827 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
4665.027333 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.5058ms (max=1200ms) -
4665.027333 Get Diagnostic Response Positive response was received. -
4665.027333 Diagnostic response 0x51, 0x01 -
4665.027333 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.182.2. (In for loop)Wait for the diagnostics to start: None
4667.427333 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.182.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
4667.427333 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
4667.428913 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.57983ms (max=1000ms) -
4667.428913 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
4667.445840 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.9265ms (max=1200ms) -
4667.445840 Get Diagnostic Response Positive response was received. -
4667.445840 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
4667.445840 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.182.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
4667.445840 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 182 -
4667.445840 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 182 fail
fail
11.182.5. (In for loop)Wait for FDC10 reached TestPass limit: None
4683.445840 1 Waited for 16.000 s -
11.183. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 183)
11.183.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
4683.445840 Diagnostic request 0x11, 0x01 -
4683.447239 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.39931ms (max=1000ms) -
4683.447239 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
4683.455689 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.44981ms (max=1200ms) -
4683.455689 Get Diagnostic Response Positive response was received. -
4683.455689 Diagnostic response 0x51, 0x01 -
4683.455689 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.183.2. (In for loop)Wait for the diagnostics to start: None
4685.855689 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.183.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
4685.855689 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
4685.857114 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.42534ms (max=1000ms) -
4685.857114 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
4685.874249 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.1345ms (max=1200ms) -
4685.874249 Get Diagnostic Response Positive response was received. -
4685.874249 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
4685.874249 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.183.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
4685.874249 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 183 -
4685.874249 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 183 fail
fail
11.183.5. (In for loop)Wait for FDC10 reached TestPass limit: None
4701.874249 1 Waited for 16.000 s -
11.184. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 184)
11.184.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
4701.874249 Diagnostic request 0x11, 0x01 -
4701.875820 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.57122ms (max=1000ms) -
4701.875820 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
4701.884102 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.28181ms (max=1200ms) -
4701.884102 Get Diagnostic Response Positive response was received. -
4701.884102 Diagnostic response 0x51, 0x01 -
4701.884102 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.184.2. (In for loop)Wait for the diagnostics to start: None
4704.284102 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.184.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
4704.284102 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
4704.285468 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.36669ms (max=1000ms) -
4704.285468 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
4704.302705 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.2365ms (max=1200ms) -
4704.302705 Get Diagnostic Response Positive response was received. -
4704.302705 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
4704.302705 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.184.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
4704.302705 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 184 -
4704.302705 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 184 fail
fail
11.184.5. (In for loop)Wait for FDC10 reached TestPass limit: None
4720.302705 1 Waited for 16.000 s -
11.185. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 185)
11.185.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
4720.302705 Diagnostic request 0x11, 0x01 -
4720.304188 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.48345ms (max=1000ms) -
4720.304188 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
4720.312548 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.3598ms (max=1200ms) -
4720.312548 Get Diagnostic Response Positive response was received. -
4720.312548 Diagnostic response 0x51, 0x01 -
4720.312548 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.185.2. (In for loop)Wait for the diagnostics to start: None
4722.712548 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.185.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
4722.712548 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
4722.713974 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.42613ms (max=1000ms) -
4722.713974 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
4722.731035 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.0605ms (max=1200ms) -
4722.731035 Get Diagnostic Response Positive response was received. -
4722.731035 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
4722.731035 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.185.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
4722.731035 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 185 -
4722.731035 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 185 fail
fail
11.185.5. (In for loop)Wait for FDC10 reached TestPass limit: None
4738.731035 1 Waited for 16.000 s -
11.186. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 186)
11.186.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
4738.731035 Diagnostic request 0x11, 0x01 -
4738.732421 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.38662ms (max=1000ms) -
4738.732421 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
4738.740887 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.46583ms (max=1200ms) -
4738.740887 Get Diagnostic Response Positive response was received. -
4738.740887 Diagnostic response 0x51, 0x01 -
4738.740887 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.186.2. (In for loop)Wait for the diagnostics to start: None
4741.140887 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.186.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
4741.140887 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
4741.142302 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.41452ms (max=1000ms) -
4741.142302 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
4741.159390 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.0885ms (max=1200ms) -
4741.159390 Get Diagnostic Response Positive response was received. -
4741.159390 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
4741.159390 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.186.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
4741.159390 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 186 -
4741.159390 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 186 fail
fail
11.186.5. (In for loop)Wait for FDC10 reached TestPass limit: None
4757.159390 1 Waited for 16.000 s -
11.187. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 187)
11.187.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
4757.159390 Diagnostic request 0x11, 0x01 -
4757.160870 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.47974ms (max=1000ms) -
4757.160870 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
4757.169246 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.37581ms (max=1200ms) -
4757.169246 Get Diagnostic Response Positive response was received. -
4757.169246 Diagnostic response 0x51, 0x01 -
4757.169246 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.187.2. (In for loop)Wait for the diagnostics to start: None
4759.569246 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.187.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
4759.569246 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
4759.570893 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.64722ms (max=1000ms) -
4759.570893 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
4759.587769 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.8765ms (max=1200ms) -
4759.587769 Get Diagnostic Response Positive response was received. -
4759.587769 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
4759.587769 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.187.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
4759.587769 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 187 -
4759.587769 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 187 fail
fail
11.187.5. (In for loop)Wait for FDC10 reached TestPass limit: None
4775.587769 1 Waited for 16.000 s -
11.188. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 188)
11.188.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
4775.587769 Diagnostic request 0x11, 0x01 -
4775.589228 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.45841ms (max=1000ms) -
4775.589228 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
4775.597623 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.3958ms (max=1200ms) -
4775.597623 Get Diagnostic Response Positive response was received. -
4775.597623 Diagnostic response 0x51, 0x01 -
4775.597623 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.188.2. (In for loop)Wait for the diagnostics to start: None
4777.997623 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.188.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
4777.997623 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
4777.999089 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.46531ms (max=1000ms) -
4777.999089 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
4778.016000 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.9109ms (max=1200ms) -
4778.016000 Get Diagnostic Response Positive response was received. -
4778.016000 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
4778.016000 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.188.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
4778.016000 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 188 -
4778.016000 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 188 fail
fail
11.188.5. (In for loop)Wait for FDC10 reached TestPass limit: None
4794.016000 1 Waited for 16.000 s -
11.189. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 189)
11.189.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
4794.016000 Diagnostic request 0x11, 0x01 -
4794.017269 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.26923ms (max=1000ms) -
4794.017269 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
4794.025849 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.57983ms (max=1200ms) -
4794.025849 Get Diagnostic Response Positive response was received. -
4794.025849 Diagnostic response 0x51, 0x01 -
4794.025849 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.189.2. (In for loop)Wait for the diagnostics to start: None
4796.425849 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.189.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
4796.425849 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
4796.427306 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.45764ms (max=1000ms) -
4796.427306 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
4796.444205 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.8985ms (max=1200ms) -
4796.444205 Get Diagnostic Response Positive response was received. -
4796.444205 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
4796.444205 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.189.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
4796.444205 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 189 -
4796.444205 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 189 fail
fail
11.189.5. (In for loop)Wait for FDC10 reached TestPass limit: None
4812.444205 1 Waited for 16.000 s -
11.190. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 190)
11.190.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
4812.444205 Diagnostic request 0x11, 0x01 -
4812.445503 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.29866ms (max=1000ms) -
4812.445503 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
4812.454055 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.5518ms (max=1200ms) -
4812.454055 Get Diagnostic Response Positive response was received. -
4812.454055 Diagnostic response 0x51, 0x01 -
4812.454055 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.190.2. (In for loop)Wait for the diagnostics to start: None
4814.854055 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.190.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
4814.854055 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
4814.855505 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.44989ms (max=1000ms) -
4814.855505 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
4814.872612 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.1065ms (max=1200ms) -
4814.872612 Get Diagnostic Response Positive response was received. -
4814.872612 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
4814.872612 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.190.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
4814.872612 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 190 -
4814.872612 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 190 fail
fail
11.190.5. (In for loop)Wait for FDC10 reached TestPass limit: None
4830.872612 1 Waited for 16.000 s -
11.191. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 191)
11.191.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
4830.872612 Diagnostic request 0x11, 0x01 -
4830.873981 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.36894ms (max=1000ms) -
4830.873981 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
4830.882462 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.4818ms (max=1200ms) -
4830.882462 Get Diagnostic Response Positive response was received. -
4830.882462 Diagnostic response 0x51, 0x01 -
4830.882462 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.191.2. (In for loop)Wait for the diagnostics to start: None
4833.282462 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.191.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
4833.282462 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
4833.283916 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.45408ms (max=1000ms) -
4833.283916 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
4833.300911 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.9945ms (max=1200ms) -
4833.300911 Get Diagnostic Response Positive response was received. -
4833.300911 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
4833.300911 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.191.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
4833.300911 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 191 -
4833.300911 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 191 fail
fail
11.191.5. (In for loop)Wait for FDC10 reached TestPass limit: None
4849.300911 1 Waited for 16.000 s -
11.192. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 192)
11.192.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
4849.300911 Diagnostic request 0x11, 0x01 -
4849.302269 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.35791ms (max=1000ms) -
4849.302269 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
4849.310763 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.4938ms (max=1200ms) -
4849.310763 Get Diagnostic Response Positive response was received. -
4849.310763 Diagnostic response 0x51, 0x01 -
4849.310763 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.192.2. (In for loop)Wait for the diagnostics to start: None
4851.710763 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.192.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
4851.710763 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
4851.712229 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.46641ms (max=1000ms) -
4851.712229 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
4851.729271 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.0425ms (max=1200ms) -
4851.729271 Get Diagnostic Response Positive response was received. -
4851.729271 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
4851.729271 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.192.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
4851.729271 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 192 -
4851.729271 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 192 fail
fail
11.192.5. (In for loop)Wait for FDC10 reached TestPass limit: None
4867.729271 1 Waited for 16.000 s -
11.193. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 193)
11.193.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
4867.729271 Diagnostic request 0x11, 0x01 -
4867.730861 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.5898ms (max=1000ms) -
4867.730861 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
4867.739123 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.26181ms (max=1200ms) -
4867.739123 Get Diagnostic Response Positive response was received. -
4867.739123 Diagnostic response 0x51, 0x01 -
4867.739123 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.193.2. (In for loop)Wait for the diagnostics to start: None
4870.139123 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.193.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
4870.139123 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
4870.140452 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.32891ms (max=1000ms) -
4870.140452 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
4870.157596 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.1445ms (max=1200ms) -
4870.157596 Get Diagnostic Response Positive response was received. -
4870.157596 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
4870.157596 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.193.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
4870.157596 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 193 -
4870.157596 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 193 fail
fail
11.193.5. (In for loop)Wait for FDC10 reached TestPass limit: None
4886.157596 1 Waited for 16.000 s -
11.194. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 194)
11.194.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
4886.157596 Diagnostic request 0x11, 0x01 -
4886.159258 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.6613ms (max=1000ms) -
4886.159258 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
4886.167450 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.19181ms (max=1200ms) -
4886.167450 Get Diagnostic Response Positive response was received. -
4886.167450 Diagnostic response 0x51, 0x01 -
4886.167450 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.194.2. (In for loop)Wait for the diagnostics to start: None
4888.567450 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.194.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
4888.567450 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
4888.569043 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.5932ms (max=1000ms) -
4888.569043 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
4888.585937 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.8945ms (max=1200ms) -
4888.585937 Get Diagnostic Response Positive response was received. -
4888.585937 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
4888.585937 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.194.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
4888.585937 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 194 -
4888.585937 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 194 fail
fail
11.194.5. (In for loop)Wait for FDC10 reached TestPass limit: None
4904.585937 1 Waited for 16.000 s -
11.195. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 195)
11.195.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
4904.585937 Diagnostic request 0x11, 0x01 -
4904.587284 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.34661ms (max=1000ms) -
4904.587284 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
4904.595792 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.5078ms (max=1200ms) -
4904.595792 Get Diagnostic Response Positive response was received. -
4904.595792 Diagnostic response 0x51, 0x01 -
4904.595792 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.195.2. (In for loop)Wait for the diagnostics to start: None
4906.995792 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.195.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
4906.995792 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
4906.997247 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.45511ms (max=1000ms) -
4906.997247 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
4907.014314 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.0669ms (max=1200ms) -
4907.014314 Get Diagnostic Response Positive response was received. -
4907.014314 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
4907.014314 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.195.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
4907.014314 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 195 -
4907.014314 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 195 fail
fail
11.195.5. (In for loop)Wait for FDC10 reached TestPass limit: None
4923.014314 1 Waited for 16.000 s -
11.196. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 196)
11.196.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
4923.014314 Diagnostic request 0x11, 0x01 -
4923.015841 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.5272ms (max=1000ms) -
4923.015841 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
4923.024161 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.31981ms (max=1200ms) -
4923.024161 Get Diagnostic Response Positive response was received. -
4923.024161 Diagnostic response 0x51, 0x01 -
4923.024161 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.196.2. (In for loop)Wait for the diagnostics to start: None
4925.424161 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.196.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
4925.424161 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
4925.425482 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.32125ms (max=1000ms) -
4925.425482 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
4925.442756 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.2745ms (max=1200ms) -
4925.442756 Get Diagnostic Response Positive response was received. -
4925.442756 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
4925.442756 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.196.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
4925.442756 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 196 -
4925.442756 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 196 fail
fail
11.196.5. (In for loop)Wait for FDC10 reached TestPass limit: None
4941.442756 1 Waited for 16.000 s -
11.197. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 197)
11.197.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
4941.442756 Diagnostic request 0x11, 0x01 -
4941.444191 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.43483ms (max=1000ms) -
4941.444191 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
4941.452605 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.41384ms (max=1200ms) -
4941.452605 Get Diagnostic Response Positive response was received. -
4941.452605 Diagnostic response 0x51, 0x01 -
4941.452605 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.197.2. (In for loop)Wait for the diagnostics to start: None
4943.852605 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.197.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
4943.852605 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
4943.854130 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.52448ms (max=1000ms) -
4943.854130 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
4943.871040 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.9105ms (max=1200ms) -
4943.871040 Get Diagnostic Response Positive response was received. -
4943.871040 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
4943.871040 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.197.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
4943.871040 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 197 -
4943.871040 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 197 fail
fail
11.197.5. (In for loop)Wait for FDC10 reached TestPass limit: None
4959.871040 1 Waited for 16.000 s -
11.198. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 198)
11.198.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
4959.871040 Diagnostic request 0x11, 0x01 -
4959.872421 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.38061ms (max=1000ms) -
4959.872421 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
4959.880894 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.4738ms (max=1200ms) -
4959.880894 Get Diagnostic Response Positive response was received. -
4959.880894 Diagnostic response 0x51, 0x01 -
4959.880894 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.198.2. (In for loop)Wait for the diagnostics to start: None
4962.280894 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.198.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
4962.280894 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
4962.282311 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.41661ms (max=1000ms) -
4962.282311 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
4962.299376 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.0645ms (max=1200ms) -
4962.299376 Get Diagnostic Response Positive response was received. -
4962.299376 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
4962.299376 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.198.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
4962.299376 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 198 -
4962.299376 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 198 fail
fail
11.198.5. (In for loop)Wait for FDC10 reached TestPass limit: None
4978.299376 1 Waited for 16.000 s -
11.199. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 199)
11.199.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
4978.299376 Diagnostic request 0x11, 0x01 -
4978.300984 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.60844ms (max=1000ms) -
4978.300984 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
4978.309226 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.24183ms (max=1200ms) -
4978.309226 Get Diagnostic Response Positive response was received. -
4978.309226 Diagnostic response 0x51, 0x01 -
4978.309226 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.199.2. (In for loop)Wait for the diagnostics to start: None
4980.709226 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.199.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
4980.709226 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
4980.710556 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.32997ms (max=1000ms) -
4980.710556 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
4980.727764 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.2085ms (max=1200ms) -
4980.727764 Get Diagnostic Response Positive response was received. -
4980.727764 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
4980.727764 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.199.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
4980.727764 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 199 -
4980.727764 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 199 fail
fail
11.199.5. (In for loop)Wait for FDC10 reached TestPass limit: None
4996.727764 1 Waited for 16.000 s -
11.200. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 200)
11.200.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
4996.727764 Diagnostic request 0x11, 0x01 -
4996.729132 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.36784ms (max=1000ms) -
4996.729132 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
4996.737614 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.4818ms (max=1200ms) -
4996.737614 Get Diagnostic Response Positive response was received. -
4996.737614 Diagnostic response 0x51, 0x01 -
4996.737614 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.200.2. (In for loop)Wait for the diagnostics to start: None
4999.137614 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.200.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
4999.137614 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
4999.139132 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.51801ms (max=1000ms) -
4999.139132 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
4999.156176 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.0445ms (max=1200ms) -
4999.156176 Get Diagnostic Response Positive response was received. -
4999.156176 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
4999.156176 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.200.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
4999.156176 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 200 -
4999.156176 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 200 fail
fail
11.200.5. (In for loop)Wait for FDC10 reached TestPass limit: None
5015.156176 1 Waited for 16.000 s -
11.201. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 201)
11.201.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
5015.156176 Diagnostic request 0x11, 0x01 -
5015.157471 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.29422ms (max=1000ms) -
5015.157471 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
5015.166028 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.55781ms (max=1200ms) -
5015.166028 Get Diagnostic Response Positive response was received. -
5015.166028 Diagnostic response 0x51, 0x01 -
5015.166028 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.201.2. (In for loop)Wait for the diagnostics to start: None
5017.566028 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.201.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
5017.566028 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
5017.567518 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.4898ms (max=1000ms) -
5017.567518 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
5017.584391 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.8725ms (max=1200ms) -
5017.584391 Get Diagnostic Response Positive response was received. -
5017.584391 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
5017.584391 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.201.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
5017.584391 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 201 -
5017.584391 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 201 fail
fail
11.201.5. (In for loop)Wait for FDC10 reached TestPass limit: None
5033.584391 1 Waited for 16.000 s -
11.202. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 202)
11.202.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
5033.584391 Diagnostic request 0x11, 0x01 -
5033.585822 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.43147ms (max=1000ms) -
5033.585822 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
5033.594242 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.41984ms (max=1200ms) -
5033.594242 Get Diagnostic Response Positive response was received. -
5033.594242 Diagnostic response 0x51, 0x01 -
5033.594242 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.202.2. (In for loop)Wait for the diagnostics to start: None
5035.994242 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.202.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
5035.994242 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
5035.995790 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.548ms (max=1000ms) -
5035.995790 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
5036.012599 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.8089ms (max=1200ms) -
5036.012599 Get Diagnostic Response Positive response was received. -
5036.012599 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
5036.012599 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.202.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
5036.012599 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 202 -
5036.012599 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 202 fail
fail
11.202.5. (In for loop)Wait for FDC10 reached TestPass limit: None
5052.012599 1 Waited for 16.000 s -
11.203. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 203)
11.203.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
5052.012599 Diagnostic request 0x11, 0x01 -
5052.013949 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.3505ms (max=1000ms) -
5052.013949 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
5052.022451 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.5018ms (max=1200ms) -
5052.022451 Get Diagnostic Response Positive response was received. -
5052.022451 Diagnostic response 0x51, 0x01 -
5052.022451 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.203.2. (In for loop)Wait for the diagnostics to start: None
5054.422451 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.203.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
5054.422451 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
5054.423880 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.42916ms (max=1000ms) -
5054.423880 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
5054.440955 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.0745ms (max=1200ms) -
5054.440955 Get Diagnostic Response Positive response was received. -
5054.440955 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
5054.440955 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.203.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
5054.440955 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 203 -
5054.440955 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 203 fail
fail
11.203.5. (In for loop)Wait for FDC10 reached TestPass limit: None
5070.440955 1 Waited for 16.000 s -
11.204. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 204)
11.204.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
5070.440955 Diagnostic request 0x11, 0x01 -
5070.442269 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.31414ms (max=1000ms) -
5070.442269 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
5070.450809 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.53981ms (max=1200ms) -
5070.450809 Get Diagnostic Response Positive response was received. -
5070.450809 Diagnostic response 0x51, 0x01 -
5070.450809 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.204.2. (In for loop)Wait for the diagnostics to start: None
5072.850809 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.204.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
5072.850809 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
5072.852209 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.39966ms (max=1000ms) -
5072.852209 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
5072.869221 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.0125ms (max=1200ms) -
5072.869221 Get Diagnostic Response Positive response was received. -
5072.869221 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
5072.869221 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.204.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
5072.869221 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 204 -
5072.869221 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 204 fail
fail
11.204.5. (In for loop)Wait for FDC10 reached TestPass limit: None
5088.869221 1 Waited for 16.000 s -
11.205. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 205)
11.205.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
5088.869221 Diagnostic request 0x11, 0x01 -
5088.870493 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.27202ms (max=1000ms) -
5088.870493 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
5088.879077 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.5838ms (max=1200ms) -
5088.879077 Get Diagnostic Response Positive response was received. -
5088.879077 Diagnostic response 0x51, 0x01 -
5088.879077 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.205.2. (In for loop)Wait for the diagnostics to start: None
5091.279077 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.205.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
5091.279077 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
5091.280443 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.36627ms (max=1000ms) -
5091.280443 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
5091.297440 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.9965ms (max=1200ms) -
5091.297440 Get Diagnostic Response Positive response was received. -
5091.297440 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
5091.297440 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.205.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
5091.297440 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 205 -
5091.297440 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 205 fail
fail
11.205.5. (In for loop)Wait for FDC10 reached TestPass limit: None
5107.297440 1 Waited for 16.000 s -
11.206. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 206)
11.206.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
5107.297440 Diagnostic request 0x11, 0x01 -
5107.298814 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.37459ms (max=1000ms) -
5107.298814 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
5107.307290 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.4758ms (max=1200ms) -
5107.307290 Get Diagnostic Response Positive response was received. -
5107.307290 Diagnostic response 0x51, 0x01 -
5107.307290 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.206.2. (In for loop)Wait for the diagnostics to start: None
5109.707290 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.206.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
5109.707290 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
5109.708771 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.48102ms (max=1000ms) -
5109.708771 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
5109.725817 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.0465ms (max=1200ms) -
5109.725817 Get Diagnostic Response Positive response was received. -
5109.725817 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
5109.725817 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.206.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
5109.725817 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 206 -
5109.725817 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 206 fail
fail
11.206.5. (In for loop)Wait for FDC10 reached TestPass limit: None
5125.725817 1 Waited for 16.000 s -
11.207. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 207)
11.207.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
5125.725817 Diagnostic request 0x11, 0x01 -
5125.727198 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.38098ms (max=1000ms) -
5125.727198 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
5125.735668 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.46983ms (max=1200ms) -
5125.735668 Get Diagnostic Response Positive response was received. -
5125.735668 Diagnostic response 0x51, 0x01 -
5125.735668 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.207.2. (In for loop)Wait for the diagnostics to start: None
5128.135668 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.207.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
5128.135668 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
5128.137112 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.44352ms (max=1000ms) -
5128.137112 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
5128.154120 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.0085ms (max=1200ms) -
5128.154120 Get Diagnostic Response Positive response was received. -
5128.154120 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
5128.154120 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.207.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
5128.154120 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 207 -
5128.154120 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 207 fail
fail
11.207.5. (In for loop)Wait for FDC10 reached TestPass limit: None
5144.154120 1 Waited for 16.000 s -
11.208. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 208)
11.208.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
5144.154120 Diagnostic request 0x11, 0x01 -
5144.155413 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.29305ms (max=1000ms) -
5144.155413 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
5144.163973 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.5598ms (max=1200ms) -
5144.163973 Get Diagnostic Response Positive response was received. -
5144.163973 Diagnostic response 0x51, 0x01 -
5144.163973 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.208.2. (In for loop)Wait for the diagnostics to start: None
5146.563973 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.208.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
5146.563973 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
5146.565412 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.43914ms (max=1000ms) -
5146.565412 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
5146.582495 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.0825ms (max=1200ms) -
5146.582495 Get Diagnostic Response Positive response was received. -
5146.582495 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
5146.582495 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.208.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
5146.582495 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 208 -
5146.582495 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 208 fail
fail
11.208.5. (In for loop)Wait for FDC10 reached TestPass limit: None
5162.582495 1 Waited for 16.000 s -
11.209. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 209)
11.209.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
5162.582495 Diagnostic request 0x11, 0x01 -
5162.583985 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.48972ms (max=1000ms) -
5162.583985 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
5162.592342 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.35783ms (max=1200ms) -
5162.592342 Get Diagnostic Response Positive response was received. -
5162.592342 Diagnostic response 0x51, 0x01 -
5162.592342 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.209.2. (In for loop)Wait for the diagnostics to start: None
5164.992342 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.209.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
5164.992342 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
5164.993818 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.47609ms (max=1000ms) -
5164.993818 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
5165.010731 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.9125ms (max=1200ms) -
5165.010731 Get Diagnostic Response Positive response was received. -
5165.010731 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
5165.010731 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.209.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
5165.010731 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 209 -
5165.010731 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 209 fail
fail
11.209.5. (In for loop)Wait for FDC10 reached TestPass limit: None
5181.010731 1 Waited for 16.000 s -
11.210. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 210)
11.210.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
5181.010731 Diagnostic request 0x11, 0x01 -
5181.012138 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.40744ms (max=1000ms) -
5181.012138 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
5181.020582 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.4438ms (max=1200ms) -
5181.020582 Get Diagnostic Response Positive response was received. -
5181.020582 Diagnostic response 0x51, 0x01 -
5181.020582 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.210.2. (In for loop)Wait for the diagnostics to start: None
5183.420582 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.210.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
5183.420582 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
5183.422030 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.44758ms (max=1000ms) -
5183.422030 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
5183.438958 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.9285ms (max=1200ms) -
5183.438958 Get Diagnostic Response Positive response was received. -
5183.438958 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
5183.438958 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.210.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
5183.438958 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 210 -
5183.438958 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 210 fail
fail
11.210.5. (In for loop)Wait for FDC10 reached TestPass limit: None
5199.438958 1 Waited for 16.000 s -
11.211. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 211)
11.211.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
5199.438958 Diagnostic request 0x11, 0x01 -
5199.440350 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.39142ms (max=1000ms) -
5199.440350 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
5199.448809 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.4598ms (max=1200ms) -
5199.448809 Get Diagnostic Response Positive response was received. -
5199.448809 Diagnostic response 0x51, 0x01 -
5199.448809 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.211.2. (In for loop)Wait for the diagnostics to start: None
5201.848809 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.211.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
5201.848809 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
5201.850198 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.38888ms (max=1000ms) -
5201.850198 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
5201.867309 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.1105ms (max=1200ms) -
5201.867309 Get Diagnostic Response Positive response was received. -
5201.867309 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
5201.867309 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.211.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
5201.867309 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 211 -
5201.867309 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 211 fail
fail
11.211.5. (In for loop)Wait for FDC10 reached TestPass limit: None
5217.867309 1 Waited for 16.000 s -
11.212. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 212)
11.212.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
5217.867309 Diagnostic request 0x11, 0x01 -
5217.868821 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.51247ms (max=1000ms) -
5217.868821 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
5217.877165 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.34381ms (max=1200ms) -
5217.877165 Get Diagnostic Response Positive response was received. -
5217.877165 Diagnostic response 0x51, 0x01 -
5217.877165 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.212.2. (In for loop)Wait for the diagnostics to start: None
5220.277165 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.212.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
5220.277165 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
5220.278527 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.36178ms (max=1000ms) -
5220.278527 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
5220.295693 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.1665ms (max=1200ms) -
5220.295693 Get Diagnostic Response Positive response was received. -
5220.295693 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
5220.295693 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.212.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
5220.295693 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 212 -
5220.295693 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 212 fail
fail
11.212.5. (In for loop)Wait for FDC10 reached TestPass limit: None
5236.295693 1 Waited for 16.000 s -
11.213. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 213)
11.213.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
5236.295693 Diagnostic request 0x11, 0x01 -
5236.297187 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.49356ms (max=1000ms) -
5236.297187 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
5236.305543 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.3558ms (max=1200ms) -
5236.305543 Get Diagnostic Response Positive response was received. -
5236.305543 Diagnostic response 0x51, 0x01 -
5236.305543 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.213.2. (In for loop)Wait for the diagnostics to start: None
5238.705543 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.213.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
5238.705543 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
5238.706979 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.43648ms (max=1000ms) -
5238.706979 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
5238.724048 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.0685ms (max=1200ms) -
5238.724048 Get Diagnostic Response Positive response was received. -
5238.724048 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
5238.724048 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.213.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
5238.724048 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 213 -
5238.724048 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 213 fail
fail
11.213.5. (In for loop)Wait for FDC10 reached TestPass limit: None
5254.724048 1 Waited for 16.000 s -
11.214. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 214)
11.214.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
5254.724048 Diagnostic request 0x11, 0x01 -
5254.725408 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.36064ms (max=1000ms) -
5254.725408 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
5254.733900 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.49183ms (max=1200ms) -
5254.733900 Get Diagnostic Response Positive response was received. -
5254.733900 Diagnostic response 0x51, 0x01 -
5254.733900 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.214.2. (In for loop)Wait for the diagnostics to start: None
5257.133900 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.214.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
5257.133900 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
5257.135313 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.4128ms (max=1000ms) -
5257.135313 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
5257.152343 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.0305ms (max=1200ms) -
5257.152343 Get Diagnostic Response Positive response was received. -
5257.152343 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
5257.152343 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.214.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
5257.152343 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 214 -
5257.152343 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 214 fail
fail
11.214.5. (In for loop)Wait for FDC10 reached TestPass limit: None
5273.152343 1 Waited for 16.000 s -
11.215. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 215)
11.215.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
5273.152343 Diagnostic request 0x11, 0x01 -
5273.153762 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.41864ms (max=1000ms) -
5273.153762 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
5273.162202 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.4398ms (max=1200ms) -
5273.162202 Get Diagnostic Response Positive response was received. -
5273.162202 Diagnostic response 0x51, 0x01 -
5273.162202 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.215.2. (In for loop)Wait for the diagnostics to start: None
5275.562202 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.215.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
5275.562202 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
5275.563521 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.31931ms (max=1000ms) -
5275.563521 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
5275.580754 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.2325ms (max=1200ms) -
5275.580754 Get Diagnostic Response Positive response was received. -
5275.580754 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
5275.580754 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.215.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
5275.580754 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 215 -
5275.580754 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 215 fail
fail
11.215.5. (In for loop)Wait for FDC10 reached TestPass limit: None
5291.580754 1 Waited for 16.000 s -
11.216. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 216)
11.216.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
5291.580754 Diagnostic request 0x11, 0x01 -
5291.582164 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.41088ms (max=1000ms) -
5291.582164 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
5291.590604 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.43981ms (max=1200ms) -
5291.590604 Get Diagnostic Response Positive response was received. -
5291.590604 Diagnostic response 0x51, 0x01 -
5291.590604 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.216.2. (In for loop)Wait for the diagnostics to start: None
5293.990604 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.216.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
5293.990604 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
5293.992053 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.44903ms (max=1000ms) -
5293.992053 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
5294.009090 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.0365ms (max=1200ms) -
5294.009090 Get Diagnostic Response Positive response was received. -
5294.009090 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
5294.009090 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.216.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
5294.009090 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 216 -
5294.009090 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 216 fail
fail
11.216.5. (In for loop)Wait for FDC10 reached TestPass limit: None
5310.009090 1 Waited for 16.000 s -
11.217. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 217)
11.217.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
5310.009090 Diagnostic request 0x11, 0x01 -
5310.010355 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.26516ms (max=1000ms) -
5310.010355 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
5310.018943 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.58781ms (max=1200ms) -
5310.018943 Get Diagnostic Response Positive response was received. -
5310.018943 Diagnostic response 0x51, 0x01 -
5310.018943 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.217.2. (In for loop)Wait for the diagnostics to start: None
5312.418943 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.217.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
5312.418943 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
5312.420291 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.34809ms (max=1000ms) -
5312.420291 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
5312.437441 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.1505ms (max=1200ms) -
5312.437441 Get Diagnostic Response Positive response was received. -
5312.437441 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
5312.437441 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.217.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
5312.437441 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 217 -
5312.437441 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 217 fail
fail
11.217.5. (In for loop)Wait for FDC10 reached TestPass limit: None
5328.437441 1 Waited for 16.000 s -
11.218. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 218)
11.218.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
5328.437441 Diagnostic request 0x11, 0x01 -
5328.438785 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.34403ms (max=1000ms) -
5328.438785 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
5328.447293 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.5078ms (max=1200ms) -
5328.447293 Get Diagnostic Response Positive response was received. -
5328.447293 Diagnostic response 0x51, 0x01 -
5328.447293 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.218.2. (In for loop)Wait for the diagnostics to start: None
5330.847293 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.218.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
5330.847293 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
5330.848866 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.57319ms (max=1000ms) -
5330.848866 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
5330.865807 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.9405ms (max=1200ms) -
5330.865807 Get Diagnostic Response Positive response was received. -
5330.865807 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
5330.865807 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.218.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
5330.865807 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 218 -
5330.865807 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 218 fail
fail
11.218.5. (In for loop)Wait for FDC10 reached TestPass limit: None
5346.865807 1 Waited for 16.000 s -
11.219. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 219)
11.219.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
5346.865807 Diagnostic request 0x11, 0x01 -
5346.867198 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.39084ms (max=1000ms) -
5346.867198 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
5346.875660 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.46181ms (max=1200ms) -
5346.875660 Get Diagnostic Response Positive response was received. -
5346.875660 Diagnostic response 0x51, 0x01 -
5346.875660 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.219.2. (In for loop)Wait for the diagnostics to start: None
5349.275660 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.219.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
5349.275660 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
5349.277099 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.43901ms (max=1000ms) -
5349.277099 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
5349.294155 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.0565ms (max=1200ms) -
5349.294155 Get Diagnostic Response Positive response was received. -
5349.294155 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
5349.294155 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.219.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
5349.294155 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 219 -
5349.294155 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 219 fail
fail
11.219.5. (In for loop)Wait for FDC10 reached TestPass limit: None
5365.294155 1 Waited for 16.000 s -
11.220. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 220)
11.220.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
5365.294155 Diagnostic request 0x11, 0x01 -
5365.295413 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.25802ms (max=1000ms) -
5365.295413 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
5365.304011 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.5978ms (max=1200ms) -
5365.304011 Get Diagnostic Response Positive response was received. -
5365.304011 Diagnostic response 0x51, 0x01 -
5365.304011 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.220.2. (In for loop)Wait for the diagnostics to start: None
5367.704011 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.220.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
5367.704011 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
5367.705489 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.47864ms (max=1000ms) -
5367.705489 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
5367.722560 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.0705ms (max=1200ms) -
5367.722560 Get Diagnostic Response Positive response was received. -
5367.722560 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
5367.722560 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.220.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
5367.722560 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 220 -
5367.722560 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 220 fail
fail
11.220.5. (In for loop)Wait for FDC10 reached TestPass limit: None
5383.722560 1 Waited for 16.000 s -
11.221. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 221)
11.221.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
5383.722560 Diagnostic request 0x11, 0x01 -
5383.724073 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.51314ms (max=1000ms) -
5383.724073 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
5383.732411 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.3378ms (max=1200ms) -
5383.732411 Get Diagnostic Response Positive response was received. -
5383.732411 Diagnostic response 0x51, 0x01 -
5383.732411 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.221.2. (In for loop)Wait for the diagnostics to start: None
5386.132411 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.221.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
5386.132411 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
5386.133882 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.47064ms (max=1000ms) -
5386.133882 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
5386.150892 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.0105ms (max=1200ms) -
5386.150892 Get Diagnostic Response Positive response was received. -
5386.150892 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
5386.150892 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.221.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
5386.150892 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 221 -
5386.150892 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 221 fail
fail
11.221.5. (In for loop)Wait for FDC10 reached TestPass limit: None
5402.150892 1 Waited for 16.000 s -
11.222. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 222)
11.222.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
5402.150892 Diagnostic request 0x11, 0x01 -
5402.152270 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.37795ms (max=1000ms) -
5402.152270 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
5402.160744 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.4738ms (max=1200ms) -
5402.160744 Get Diagnostic Response Positive response was received. -
5402.160744 Diagnostic response 0x51, 0x01 -
5402.160744 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.222.2. (In for loop)Wait for the diagnostics to start: None
5404.560744 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.222.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
5404.560744 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
5404.562178 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.43458ms (max=1000ms) -
5404.562178 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
5404.579217 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.0385ms (max=1200ms) -
5404.579217 Get Diagnostic Response Positive response was received. -
5404.579217 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
5404.579217 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.222.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
5404.579217 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 222 -
5404.579217 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 222 fail
fail
11.222.5. (In for loop)Wait for FDC10 reached TestPass limit: None
5420.579217 1 Waited for 16.000 s -
11.223. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 223)
11.223.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
5420.579217 Diagnostic request 0x11, 0x01 -
5420.580516 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.29931ms (max=1000ms) -
5420.580516 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
5420.589064 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.5478ms (max=1200ms) -
5420.589064 Get Diagnostic Response Positive response was received. -
5420.589064 Diagnostic response 0x51, 0x01 -
5420.589064 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.223.2. (In for loop)Wait for the diagnostics to start: None
5422.989064 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.223.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
5422.989064 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
5422.990449 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.38523ms (max=1000ms) -
5422.990449 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
5423.007570 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.1205ms (max=1200ms) -
5423.007570 Get Diagnostic Response Positive response was received. -
5423.007570 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
5423.007570 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.223.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
5423.007570 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 223 -
5423.007570 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 223 fail
fail
11.223.5. (In for loop)Wait for FDC10 reached TestPass limit: None
5439.007570 1 Waited for 16.000 s -
11.224. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 224)
11.224.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
5439.007570 Diagnostic request 0x11, 0x01 -
5439.009128 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.55864ms (max=1000ms) -
5439.009128 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
5439.017420 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.29183ms (max=1200ms) -
5439.017420 Get Diagnostic Response Positive response was received. -
5439.017420 Diagnostic response 0x51, 0x01 -
5439.017420 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.224.2. (In for loop)Wait for the diagnostics to start: None
5441.417420 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.224.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
5441.417420 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
5441.418947 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.52677ms (max=1000ms) -
5441.418947 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
5441.435913 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.9665ms (max=1200ms) -
5441.435913 Get Diagnostic Response Positive response was received. -
5441.435913 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
5441.435913 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.224.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
5441.435913 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 224 -
5441.435913 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 224 fail
fail
11.224.5. (In for loop)Wait for FDC10 reached TestPass limit: None
5457.435913 1 Waited for 16.000 s -
11.225. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 225)
11.225.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
5457.435913 Diagnostic request 0x11, 0x01 -
5457.437339 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.42564ms (max=1000ms) -
5457.437339 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
5457.445765 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.42581ms (max=1200ms) -
5457.445765 Get Diagnostic Response Positive response was received. -
5457.445765 Diagnostic response 0x51, 0x01 -
5457.445765 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.225.2. (In for loop)Wait for the diagnostics to start: None
5459.845765 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.225.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
5459.845765 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
5459.847238 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.47323ms (max=1000ms) -
5459.847238 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
5459.864389 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.1505ms (max=1200ms) -
5459.864389 Get Diagnostic Response Positive response was received. -
5459.864389 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
5459.864389 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.225.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
5459.864389 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 225 -
5459.864389 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 225 fail
fail
11.225.5. (In for loop)Wait for FDC10 reached TestPass limit: None
5475.864389 1 Waited for 16.000 s -
11.226. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 226)
11.226.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
5475.864389 Diagnostic request 0x11, 0x01 -
5475.865924 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.53547ms (max=1000ms) -
5475.865924 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
5475.874240 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.31583ms (max=1200ms) -
5475.874240 Get Diagnostic Response Positive response was received. -
5475.874240 Diagnostic response 0x51, 0x01 -
5475.874240 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.226.2. (In for loop)Wait for the diagnostics to start: None
5478.274240 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.226.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
5478.274240 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
5478.275558 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.318ms (max=1000ms) -
5478.275558 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
5478.292810 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.2525ms (max=1200ms) -
5478.292810 Get Diagnostic Response Positive response was received. -
5478.292810 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
5478.292810 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.226.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
5478.292810 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 226 -
5478.292810 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 226 fail
fail
11.226.5. (In for loop)Wait for FDC10 reached TestPass limit: None
5494.292810 1 Waited for 16.000 s -
11.227. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 227)
11.227.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
5494.292810 Diagnostic request 0x11, 0x01 -
5494.294169 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.35853ms (max=1000ms) -
5494.294169 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
5494.302661 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.49184ms (max=1200ms) -
5494.302661 Get Diagnostic Response Positive response was received. -
5494.302661 Diagnostic response 0x51, 0x01 -
5494.302661 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.227.2. (In for loop)Wait for the diagnostics to start: None
5496.702661 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.227.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
5496.702661 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
5496.704196 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.53531ms (max=1000ms) -
5496.704196 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
5496.721167 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.9705ms (max=1200ms) -
5496.721167 Get Diagnostic Response Positive response was received. -
5496.721167 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
5496.721167 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.227.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
5496.721167 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 227 -
5496.721167 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 227 fail
fail
11.227.5. (In for loop)Wait for FDC10 reached TestPass limit: None
5512.721167 1 Waited for 16.000 s -
11.228. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 228)
11.228.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
5512.721167 Diagnostic request 0x11, 0x01 -
5512.722489 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.32222ms (max=1000ms) -
5512.722489 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
5512.731017 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.52783ms (max=1200ms) -
5512.731017 Get Diagnostic Response Positive response was received. -
5512.731017 Diagnostic response 0x51, 0x01 -
5512.731017 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.228.2. (In for loop)Wait for the diagnostics to start: None
5515.131017 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.228.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
5515.131017 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
5515.132493 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.47645ms (max=1000ms) -
5515.132493 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
5515.149402 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.9085ms (max=1200ms) -
5515.149402 Get Diagnostic Response Positive response was received. -
5515.149402 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
5515.149402 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.228.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
5515.149402 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 228 -
5515.149402 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 228 fail
fail
11.228.5. (In for loop)Wait for FDC10 reached TestPass limit: None
5531.149402 1 Waited for 16.000 s -
11.229. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 229)
11.229.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
5531.149402 Diagnostic request 0x11, 0x01 -
5531.150948 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.54608ms (max=1000ms) -
5531.150948 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
5531.159257 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.30981ms (max=1200ms) -
5531.159257 Get Diagnostic Response Positive response was received. -
5531.159257 Diagnostic response 0x51, 0x01 -
5531.159257 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.229.2. (In for loop)Wait for the diagnostics to start: None
5533.559257 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.229.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
5533.559257 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
5533.561152 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.895ms (max=1000ms) -
5533.561152 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
5533.577597 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.4445ms (max=1200ms) -
5533.577597 Get Diagnostic Response Positive response was received. -
5533.577597 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
5533.577597 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.229.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
5533.577597 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 229 -
5533.577597 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 229 fail
fail
11.229.5. (In for loop)Wait for FDC10 reached TestPass limit: None
5549.577597 1 Waited for 16.000 s -
11.230. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 230)
11.230.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
5549.577597 Diagnostic request 0x11, 0x01 -
5549.579025 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.42851ms (max=1000ms) -
5549.579025 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
5549.587449 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.4238ms (max=1200ms) -
5549.587449 Get Diagnostic Response Positive response was received. -
5549.587449 Diagnostic response 0x51, 0x01 -
5549.587449 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.230.2. (In for loop)Wait for the diagnostics to start: None
5551.987449 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.230.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
5551.987449 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
5551.988967 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.51806ms (max=1000ms) -
5551.988967 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
5552.005956 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.9885ms (max=1200ms) -
5552.005956 Get Diagnostic Response Positive response was received. -
5552.005956 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
5552.005956 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.230.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
5552.005956 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 230 -
5552.005956 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 230 fail
fail
11.230.5. (In for loop)Wait for FDC10 reached TestPass limit: None
5568.005956 1 Waited for 16.000 s -
11.231. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 231)
11.231.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
5568.005956 Diagnostic request 0x11, 0x01 -
5568.007328 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.37244ms (max=1000ms) -
5568.007328 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
5568.015736 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.40781ms (max=1200ms) -
5568.015736 Get Diagnostic Response Positive response was received. -
5568.015736 Diagnostic response 0x51, 0x01 -
5568.015736 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.231.2. (In for loop)Wait for the diagnostics to start: None
5570.415736 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.231.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
5570.415736 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
5570.417175 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.43909ms (max=1000ms) -
5570.417175 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
5570.434102 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.9265ms (max=1200ms) -
5570.434102 Get Diagnostic Response Positive response was received. -
5570.434102 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
5570.434102 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.231.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
5570.434102 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 231 -
5570.434102 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 231 fail
fail
11.231.5. (In for loop)Wait for FDC10 reached TestPass limit: None
5586.434102 1 Waited for 16.000 s -
11.232. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 232)
11.232.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
5586.434102 Diagnostic request 0x11, 0x01 -
5586.435385 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.28348ms (max=1000ms) -
5586.435385 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
5586.443945 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.5598ms (max=1200ms) -
5586.443945 Get Diagnostic Response Positive response was received. -
5586.443945 Diagnostic response 0x51, 0x01 -
5586.443945 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.232.2. (In for loop)Wait for the diagnostics to start: None
5588.843945 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.232.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
5588.843945 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
5588.845413 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.46794ms (max=1000ms) -
5588.845413 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
5588.862357 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.9445ms (max=1200ms) -
5588.862357 Get Diagnostic Response Positive response was received. -
5588.862357 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
5588.862357 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.232.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
5588.862357 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 232 -
5588.862357 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 232 fail
fail
11.232.5. (In for loop)Wait for FDC10 reached TestPass limit: None
5604.862357 1 Waited for 16.000 s -
11.233. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 233)
11.233.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
5604.862357 Diagnostic request 0x11, 0x01 -
5604.863862 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.50444ms (max=1000ms) -
5604.863862 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
5604.872212 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.3498ms (max=1200ms) -
5604.872212 Get Diagnostic Response Positive response was received. -
5604.872212 Diagnostic response 0x51, 0x01 -
5604.872212 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.233.2. (In for loop)Wait for the diagnostics to start: None
5607.272212 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.233.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
5607.272212 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
5607.273585 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.37336ms (max=1000ms) -
5607.273585 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
5607.290623 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.0385ms (max=1200ms) -
5607.290623 Get Diagnostic Response Positive response was received. -
5607.290623 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
5607.290623 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.233.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
5607.290623 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 233 -
5607.290623 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 233 fail
fail
11.233.5. (In for loop)Wait for FDC10 reached TestPass limit: None
5623.290623 1 Waited for 16.000 s -
11.234. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 234)
11.234.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
5623.290623 Diagnostic request 0x11, 0x01 -
5623.292054 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.43087ms (max=1000ms) -
5623.292054 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
5623.300476 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.4218ms (max=1200ms) -
5623.300476 Get Diagnostic Response Positive response was received. -
5623.300476 Diagnostic response 0x51, 0x01 -
5623.300476 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.234.2. (In for loop)Wait for the diagnostics to start: None
5625.700476 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.234.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
5625.700476 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
5625.701997 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.52091ms (max=1000ms) -
5625.701997 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
5625.718968 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.9705ms (max=1200ms) -
5625.718968 Get Diagnostic Response Positive response was received. -
5625.718968 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
5625.718968 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.234.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
5625.718968 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 234 -
5625.718968 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 234 fail
fail
11.234.5. (In for loop)Wait for FDC10 reached TestPass limit: None
5641.718968 1 Waited for 16.000 s -
11.235. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 235)
11.235.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
5641.718968 Diagnostic request 0x11, 0x01 -
5641.720379 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.41131ms (max=1000ms) -
5641.720379 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
5641.728815 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.43583ms (max=1200ms) -
5641.728815 Get Diagnostic Response Positive response was received. -
5641.728815 Diagnostic response 0x51, 0x01 -
5641.728815 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.235.2. (In for loop)Wait for the diagnostics to start: None
5644.128815 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.235.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
5644.128815 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
5644.130318 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.50289ms (max=1000ms) -
5644.130318 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
5644.147218 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.9005ms (max=1200ms) -
5644.147218 Get Diagnostic Response Positive response was received. -
5644.147218 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
5644.147218 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.235.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
5644.147218 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 235 -
5644.147218 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 235 fail
fail
11.235.5. (In for loop)Wait for FDC10 reached TestPass limit: None
5660.147218 1 Waited for 16.000 s -
11.236. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 236)
11.236.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
5660.147218 Diagnostic request 0x11, 0x01 -
5660.148509 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.29062ms (max=1000ms) -
5660.148509 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
5660.157070 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.56181ms (max=1200ms) -
5660.157070 Get Diagnostic Response Positive response was received. -
5660.157070 Diagnostic response 0x51, 0x01 -
5660.157070 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.236.2. (In for loop)Wait for the diagnostics to start: None
5662.557070 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.236.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
5662.557070 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
5662.558446 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.37603ms (max=1000ms) -
5662.558446 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
5662.575519 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.0725ms (max=1200ms) -
5662.575519 Get Diagnostic Response Positive response was received. -
5662.575519 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
5662.575519 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.236.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
5662.575519 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 236 -
5662.575519 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 236 fail
fail
11.236.5. (In for loop)Wait for FDC10 reached TestPass limit: None
5678.575519 1 Waited for 16.000 s -
11.237. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 237)
11.237.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
5678.575519 Diagnostic request 0x11, 0x01 -
5678.576936 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.41708ms (max=1000ms) -
5678.576936 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
5678.585376 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.43983ms (max=1200ms) -
5678.585376 Get Diagnostic Response Positive response was received. -
5678.585376 Diagnostic response 0x51, 0x01 -
5678.585376 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.237.2. (In for loop)Wait for the diagnostics to start: None
5680.985376 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.237.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
5680.985376 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
5680.987185 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.80931ms (max=1000ms) -
5680.987185 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
5681.003920 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.7345ms (max=1200ms) -
5681.003920 Get Diagnostic Response Positive response was received. -
5681.003920 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
5681.003920 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.237.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
5681.003920 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 237 -
5681.003920 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 237 fail
fail
11.237.5. (In for loop)Wait for FDC10 reached TestPass limit: None
5697.003920 1 Waited for 16.000 s -
11.238. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 238)
11.238.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
5697.003920 Diagnostic request 0x11, 0x01 -
5697.005247 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.3277ms (max=1000ms) -
5697.005247 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
5697.013709 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.46183ms (max=1200ms) -
5697.013709 Get Diagnostic Response Positive response was received. -
5697.013709 Diagnostic response 0x51, 0x01 -
5697.013709 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.238.2. (In for loop)Wait for the diagnostics to start: None
5699.413709 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.238.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
5699.413709 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
5699.415178 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.4683ms (max=1000ms) -
5699.415178 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
5699.432086 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.9085ms (max=1200ms) -
5699.432086 Get Diagnostic Response Positive response was received. -
5699.432086 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
5699.432086 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.238.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
5699.432086 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 238 -
5699.432086 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 238 fail
fail
11.238.5. (In for loop)Wait for FDC10 reached TestPass limit: None
5715.432086 1 Waited for 16.000 s -
11.239. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 239)
11.239.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
5715.432086 Diagnostic request 0x11, 0x01 -
5715.433493 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.40741ms (max=1000ms) -
5715.433493 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
5715.441935 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.4418ms (max=1200ms) -
5715.441935 Get Diagnostic Response Positive response was received. -
5715.441935 Diagnostic response 0x51, 0x01 -
5715.441935 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.239.2. (In for loop)Wait for the diagnostics to start: None
5717.841935 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.239.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
5717.841935 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
5717.843362 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.42636ms (max=1000ms) -
5717.843362 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
5717.860386 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.0245ms (max=1200ms) -
5717.860386 Get Diagnostic Response Positive response was received. -
5717.860386 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
5717.860386 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.239.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
5717.860386 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 239 -
5717.860386 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 239 fail
fail
11.239.5. (In for loop)Wait for FDC10 reached TestPass limit: None
5733.860386 1 Waited for 16.000 s -
11.240. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 240)
11.240.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
5733.860386 Diagnostic request 0x11, 0x01 -
5733.861934 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.54758ms (max=1000ms) -
5733.861934 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
5733.870233 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.29983ms (max=1200ms) -
5733.870233 Get Diagnostic Response Positive response was received. -
5733.870233 Diagnostic response 0x51, 0x01 -
5733.870233 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.240.2. (In for loop)Wait for the diagnostics to start: None
5736.270233 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.240.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
5736.270233 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
5736.271631 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.39717ms (max=1000ms) -
5736.271631 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
5736.288607 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.9765ms (max=1200ms) -
5736.288607 Get Diagnostic Response Positive response was received. -
5736.288607 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
5736.288607 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.240.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
5736.288607 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 240 -
5736.288607 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 240 fail
fail
11.240.5. (In for loop)Wait for FDC10 reached TestPass limit: None
5752.288607 1 Waited for 16.000 s -
11.241. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 241)
11.241.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
5752.288607 Diagnostic request 0x11, 0x01 -
5752.290030 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.42312ms (max=1000ms) -
5752.290030 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
5752.298452 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.4218ms (max=1200ms) -
5752.298452 Get Diagnostic Response Positive response was received. -
5752.298452 Diagnostic response 0x51, 0x01 -
5752.298452 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.241.2. (In for loop)Wait for the diagnostics to start: None
5754.698452 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.241.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
5754.698452 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
5754.699915 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.46277ms (max=1000ms) -
5754.699915 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
5754.716723 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.8085ms (max=1200ms) -
5754.716723 Get Diagnostic Response Positive response was received. -
5754.716723 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
5754.716723 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.241.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
5754.716723 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 241 -
5754.716723 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 241 fail
fail
11.241.5. (In for loop)Wait for FDC10 reached TestPass limit: None
5770.716723 1 Waited for 16.000 s -
11.242. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 242)
11.242.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
5770.716723 Diagnostic request 0x11, 0x01 -
5770.718095 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.37208ms (max=1000ms) -
5770.718095 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
5770.726573 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.47783ms (max=1200ms) -
5770.726573 Get Diagnostic Response Positive response was received. -
5770.726573 Diagnostic response 0x51, 0x01 -
5770.726573 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.242.2. (In for loop)Wait for the diagnostics to start: None
5773.126573 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.242.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
5773.126573 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
5773.128077 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.50347ms (max=1000ms) -
5773.128077 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
5773.144951 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.8745ms (max=1200ms) -
5773.144951 Get Diagnostic Response Positive response was received. -
5773.144951 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
5773.144951 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.242.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
5773.144951 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 242 -
5773.144951 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 242 fail
fail
11.242.5. (In for loop)Wait for FDC10 reached TestPass limit: None
5789.144951 1 Waited for 16.000 s -
11.243. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 243)
11.243.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
5789.144951 Diagnostic request 0x11, 0x01 -
5789.146320 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.36858ms (max=1000ms) -
5789.146320 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
5789.154804 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.4838ms (max=1200ms) -
5789.154804 Get Diagnostic Response Positive response was received. -
5789.154804 Diagnostic response 0x51, 0x01 -
5789.154804 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.243.2. (In for loop)Wait for the diagnostics to start: None
5791.554804 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.243.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
5791.554804 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
5791.556336 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.53283ms (max=1000ms) -
5791.556336 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
5791.573041 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.7045ms (max=1200ms) -
5791.573041 Get Diagnostic Response Positive response was received. -
5791.573041 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
5791.573041 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.243.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
5791.573041 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 243 -
5791.573041 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 243 fail
fail
11.243.5. (In for loop)Wait for FDC10 reached TestPass limit: None
5807.573041 1 Waited for 16.000 s -
11.244. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 244)
11.244.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
5807.573041 Diagnostic request 0x11, 0x01 -
5807.574361 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.32048ms (max=1000ms) -
5807.574361 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
5807.582891 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.52983ms (max=1200ms) -
5807.582891 Get Diagnostic Response Positive response was received. -
5807.582891 Diagnostic response 0x51, 0x01 -
5807.582891 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.244.2. (In for loop)Wait for the diagnostics to start: None
5809.982891 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.244.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
5809.982891 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
5809.984293 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.40206ms (max=1000ms) -
5809.984293 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
5810.001222 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.9285ms (max=1200ms) -
5810.001222 Get Diagnostic Response Positive response was received. -
5810.001222 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
5810.001222 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.244.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
5810.001222 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 244 -
5810.001222 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 244 fail
fail
11.244.5. (In for loop)Wait for FDC10 reached TestPass limit: None
5826.001222 1 Waited for 16.000 s -
11.245. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 245)
11.245.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
5826.001222 Diagnostic request 0x11, 0x01 -
5826.002514 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.29194ms (max=1000ms) -
5826.002514 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
5826.011073 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.5598ms (max=1200ms) -
5826.011073 Get Diagnostic Response Positive response was received. -
5826.011073 Diagnostic response 0x51, 0x01 -
5826.011073 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.245.2. (In for loop)Wait for the diagnostics to start: None
5828.411073 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.245.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
5828.411073 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
5828.412484 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.41077ms (max=1000ms) -
5828.412484 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
5828.429329 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.8445ms (max=1200ms) -
5828.429329 Get Diagnostic Response Positive response was received. -
5828.429329 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
5828.429329 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.245.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
5828.429329 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 245 -
5828.429329 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 245 fail
fail
11.245.5. (In for loop)Wait for FDC10 reached TestPass limit: None
5844.429329 1 Waited for 16.000 s -
11.246. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 246)
11.246.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
5844.429329 Diagnostic request 0x11, 0x01 -
5844.430973 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.64475ms (max=1000ms) -
5844.430973 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
5844.439177 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.20381ms (max=1200ms) -
5844.439177 Get Diagnostic Response Positive response was received. -
5844.439177 Diagnostic response 0x51, 0x01 -
5844.439177 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.246.2. (In for loop)Wait for the diagnostics to start: None
5846.839177 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.246.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
5846.839177 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
5846.840498 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.32027ms (max=1000ms) -
5846.840498 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
5846.857620 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.1225ms (max=1200ms) -
5846.857620 Get Diagnostic Response Positive response was received. -
5846.857620 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
5846.857620 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.246.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
5846.857620 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 246 -
5846.857620 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 246 fail
fail
11.246.5. (In for loop)Wait for FDC10 reached TestPass limit: None
5862.857620 1 Waited for 16.000 s -
11.247. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 247)
11.247.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
5862.857620 Diagnostic request 0x11, 0x01 -
5862.859040 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.42031ms (max=1000ms) -
5862.859040 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
5862.867470 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.42983ms (max=1200ms) -
5862.867470 Get Diagnostic Response Positive response was received. -
5862.867470 Diagnostic response 0x51, 0x01 -
5862.867470 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.247.2. (In for loop)Wait for the diagnostics to start: None
5865.267470 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.247.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
5865.267470 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
5865.268981 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.51111ms (max=1000ms) -
5865.268981 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
5865.285928 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.9465ms (max=1200ms) -
5865.285928 Get Diagnostic Response Positive response was received. -
5865.285928 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
5865.285928 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.247.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
5865.285928 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 247 -
5865.285928 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 247 fail
fail
11.247.5. (In for loop)Wait for FDC10 reached TestPass limit: None
5881.285928 1 Waited for 16.000 s -
11.248. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 248)
11.248.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
5881.285928 Diagnostic request 0x11, 0x01 -
5881.287299 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.37169ms (max=1000ms) -
5881.287299 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
5881.295775 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.4758ms (max=1200ms) -
5881.295775 Get Diagnostic Response Positive response was received. -
5881.295775 Diagnostic response 0x51, 0x01 -
5881.295775 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.248.2. (In for loop)Wait for the diagnostics to start: None
5883.695775 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.248.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
5883.695775 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
5883.697256 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.48028ms (max=1000ms) -
5883.697256 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
5883.714220 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.9645ms (max=1200ms) -
5883.714220 Get Diagnostic Response Positive response was received. -
5883.714220 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
5883.714220 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.248.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
5883.714220 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 248 -
5883.714220 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 248 fail
fail
11.248.5. (In for loop)Wait for FDC10 reached TestPass limit: None
5899.714220 1 Waited for 16.000 s -
11.249. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 249)
11.249.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
5899.714220 Diagnostic request 0x11, 0x01 -
5899.715509 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.28905ms (max=1000ms) -
5899.715509 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
5899.724077 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.5678ms (max=1200ms) -
5899.724077 Get Diagnostic Response Positive response was received. -
5899.724077 Diagnostic response 0x51, 0x01 -
5899.724077 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.249.2. (In for loop)Wait for the diagnostics to start: None
5902.124077 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.249.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
5902.124077 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
5902.125435 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.35855ms (max=1000ms) -
5902.125435 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
5902.142514 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.0785ms (max=1200ms) -
5902.142514 Get Diagnostic Response Positive response was received. -
5902.142514 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
5902.142514 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.249.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
5902.142514 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 249 -
5902.142514 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 249 fail
fail
11.249.5. (In for loop)Wait for FDC10 reached TestPass limit: None
5918.142514 1 Waited for 16.000 s -
11.250. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 250)
11.250.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
5918.142514 Diagnostic request 0x11, 0x01 -
5918.143877 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.36269ms (max=1000ms) -
5918.143877 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
5918.152364 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.4878ms (max=1200ms) -
5918.152364 Get Diagnostic Response Positive response was received. -
5918.152364 Diagnostic response 0x51, 0x01 -
5918.152364 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.250.2. (In for loop)Wait for the diagnostics to start: None
5920.552364 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.250.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
5920.552364 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
5920.553957 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.59216ms (max=1000ms) -
5920.553957 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
5920.570903 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.9465ms (max=1200ms) -
5920.570903 Get Diagnostic Response Positive response was received. -
5920.570903 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
5920.570903 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.250.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
5920.570903 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 250 -
5920.570903 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 250 fail
fail
11.250.5. (In for loop)Wait for FDC10 reached TestPass limit: None
5936.570903 1 Waited for 16.000 s -
11.251. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 251)
11.251.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
5936.570903 Diagnostic request 0x11, 0x01 -
5936.572262 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.35906ms (max=1000ms) -
5936.572262 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
5936.580754 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.49181ms (max=1200ms) -
5936.580754 Get Diagnostic Response Positive response was received. -
5936.580754 Diagnostic response 0x51, 0x01 -
5936.580754 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.251.2. (In for loop)Wait for the diagnostics to start: None
5938.980754 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.251.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
5938.980754 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
5938.982223 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.46881ms (max=1000ms) -
5938.982223 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
5938.999273 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.0505ms (max=1200ms) -
5938.999273 Get Diagnostic Response Positive response was received. -
5938.999273 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
5938.999273 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.251.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
5938.999273 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 251 -
5938.999273 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 251 fail
fail
11.251.5. (In for loop)Wait for FDC10 reached TestPass limit: None
5954.999273 1 Waited for 16.000 s -
11.252. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 252)
11.252.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
5954.999273 Diagnostic request 0x11, 0x01 -
5955.001128 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.85491ms (max=1000ms) -
5955.001128 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
5955.009122 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=7.99381ms (max=1200ms) -
5955.009122 Get Diagnostic Response Positive response was received. -
5955.009122 Diagnostic response 0x51, 0x01 -
5955.009122 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.252.2. (In for loop)Wait for the diagnostics to start: None
5957.409122 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.252.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
5957.409122 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
5957.410503 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.38091ms (max=1000ms) -
5957.410503 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
5957.427655 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.1525ms (max=1200ms) -
5957.427655 Get Diagnostic Response Positive response was received. -
5957.427655 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
5957.427655 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.252.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
5957.427655 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 252 -
5957.427655 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 252 fail
fail
11.252.5. (In for loop)Wait for FDC10 reached TestPass limit: None
5973.427655 1 Waited for 16.000 s -
11.253. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 253)
11.253.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
5973.427655 Diagnostic request 0x11, 0x01 -
5973.429090 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.43427ms (max=1000ms) -
5973.429090 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
5973.437501 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.4118ms (max=1200ms) -
5973.437501 Get Diagnostic Response Positive response was received. -
5973.437501 Diagnostic response 0x51, 0x01 -
5973.437501 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.253.2. (In for loop)Wait for the diagnostics to start: None
5975.837501 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.253.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
5975.837501 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
5975.838976 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.47511ms (max=1000ms) -
5975.838976 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
5975.855941 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.9645ms (max=1200ms) -
5975.855941 Get Diagnostic Response Positive response was received. -
5975.855941 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
5975.855941 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.253.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
5975.855941 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 253 -
5975.855941 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 253 fail
fail
11.253.5. (In for loop)Wait for FDC10 reached TestPass limit: None
5991.855941 1 Waited for 16.000 s -
11.254. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 254)
11.254.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
5991.855941 Diagnostic request 0x11, 0x01 -
5991.857309 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.36772ms (max=1000ms) -
5991.857309 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
5991.865794 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.4858ms (max=1200ms) -
5991.865794 Get Diagnostic Response Positive response was received. -
5991.865794 Diagnostic response 0x51, 0x01 -
5991.865794 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.254.2. (In for loop)Wait for the diagnostics to start: None
5994.265794 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.254.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
5994.265794 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
5994.267222 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.42775ms (max=1000ms) -
5994.267222 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
5994.284247 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.0245ms (max=1200ms) -
5994.284247 Get Diagnostic Response Positive response was received. -
5994.284247 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
5994.284247 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.254.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
5994.284247 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 254 -
5994.284247 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 254 fail
fail
11.254.5. (In for loop)Wait for FDC10 reached TestPass limit: None
6010.284247 1 Waited for 16.000 s -
11.255. For loop: Start value = 1, Stop value = 255, iterator+= 1 (For i=1..255, increment=1; current i = 255)
11.255.1. (In for loop)Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
6010.284247 Diagnostic request 0x11, 0x01 -
6010.285685 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.43848ms (max=1000ms) -
6010.285685 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
6010.294089 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.4038ms (max=1200ms) -
6010.294089 Get Diagnostic Response Positive response was received. -
6010.294089 Diagnostic response 0x51, 0x01 -
6010.294089 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.255.2. (In for loop)Wait for the diagnostics to start: None
6012.694089 1 Waited for 2400.000 (diagnostic_start_time) ms -
11.255.3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
6012.694089 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
6012.695496 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.40681ms (max=1000ms) -
6012.695496 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
6012.712574 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.0785ms (max=1200ms) -
6012.712574 Get Diagnostic Response Positive response was received. -
6012.712574 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
6012.712574 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
11.255.4. Check OCC2 value Expected: OCC2 equal expected value: Failed
6012.712574 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 255 -
6012.712574 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 255 fail
fail
11.255.5. (In for loop)Wait for FDC10 reached TestPass limit: None
6028.712574 1 Waited for 16.000 s -
12. Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
6028.712574 Diagnostic request 0x11, 0x01 -
6028.713947 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.37314ms (max=1000ms) -
6028.713947 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
6028.722421 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.47383ms (max=1200ms) -
6028.722421 Get Diagnostic Response Positive response was received. -
6028.722421 Diagnostic response 0x51, 0x01 -
6028.722421 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
13. Wait for the diagnostics to start: None
6031.122421 1 Waited for 2400.000 (diagnostic_start_time) ms -
14. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
6031.122421 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
6031.123907 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.48611ms (max=1000ms) -
6031.123907 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
6031.140800 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.8925ms (max=1200ms) -
6031.140800 Get Diagnostic Response Positive response was received. -
6031.140800 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50, 0x02, 0x00 -
6031.140800 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
15. Check OCC2 value Expected: OCC2 equal expected value: Failed
6031.140800 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 255 -
6031.140800 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 255 fail
fail
16. Change the state of the relay, Expected: Park 1 button is pressed: Passed
6031.140800 Change Relay State Relay vt2820_channel_6 - Relay 6 state was changed to PUSHED pass
17. Change the state of the relay, Expected: Park 2 button is pressed: Passed
6031.140800 Change Relay State Relay vt2820_channel_7 - Relay 7 state was changed to PUSHED pass
18. Wait for close relay: None
6031.145800 1 Waited for 5.000 ms -
19. Check that the SWMRiLvrDiagRiLvrDiag value has been set to 2 within 200s Expected: The signal has been set: Passed
6211.215164 Resume reason Resumed on signal: CAN signal 'SWMRiLvrDiagRiLvrDiag' Elapsed time=180069ms (max=200000ms) -
6211.215164 1
[−] Waited for occurrence of 1 value condition and signal updates.
Symbol Op. Reference value Actual Result
CAN signal 'SWMRiLvrDiagRiLvrDiag' == 2 2 pass
pass
20. Wait 16s for DTC reached TestFail Limit: None
6227.215164 1 Waited for 16.000 s -
21. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
6227.215164 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
6227.216628 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.46398ms (max=1000ms) -
6227.216628 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
6227.230475 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.8466ms (max=1200ms) -
6227.230475 Get Diagnostic Response Positive response was received. -
6227.230475 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x2F, 0x02, 0x00 -
6227.230475 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
22. Check OCC2 value Expected: OCC2 equal expected value: Passed
6227.230475 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 0 -
6227.230475 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 0 pass
pass
23. Change the state of the relay, Expected: Park 1 button not is pressed: Passed
6227.230475 Change Relay State Relay vt2820_channel_6 - Relay 6 state was changed to RELEASED pass
24. Change the state of the relay, Expected: Park 2 button not is pressed: Passed
6227.230475 Change Relay State Relay vt2820_channel_7 - Relay 7 state was changed to RELEASED pass
25. Wait for open relay: None
6227.240475 1 Waited for 10.000 ms -
26. Wait 16s until DTC reached TestPass Limit: None
6243.240475 1 Waited for 16.000 s -
27. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
6243.240475 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
6243.242061 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.58666ms (max=1000ms) -
6243.242061 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
6243.260467 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=18.4051ms (max=1200ms) -
6243.260467 Get Diagnostic Response Positive response was received. -
6243.260467 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x2E, 0x02, 0x00 -
6243.260467 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
28. Check OCC2 value Expected: OCC2 equal expected value: Passed
6243.260467 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 0 -
6243.260467 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 0 pass
pass
29. Wait 10ms: None
6243.270467 1 Waited for 10.000 ms -
30. Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
6243.270467 Diagnostic request 0x11, 0x01 -
6243.271876 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.40939ms (max=1000ms) -
6243.271876 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
6243.280340 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.46431ms (max=1200ms) -
6243.280340 Get Diagnostic Response Positive response was received. -
6243.280340 Diagnostic response 0x51, 0x01 -
6243.280340 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
31. Wait for init & DTC reached TestPass Limit : None
6259.280340 1 Waited for 16.000 s -
32. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
6259.280340 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
6259.282014 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.67395ms (max=1000ms) -
6259.282014 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
6259.300586 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=18.572ms (max=1200ms) -
6259.300586 Get Diagnostic Response Positive response was received. -
6259.300586 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x2C, 0x02, 0x00 -
6259.300586 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
33. Check OCC2 value Expected: OCC2 equal expected value: Passed
6259.300586 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 0 -
6259.300586 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 0 pass
pass
34. Wait 10ms: None
6259.310586 1 Waited for 10.000 ms -
35. Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
6259.310586 Diagnostic request 0x11, 0x01 -
6259.311890 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.30337ms (max=1000ms) -
6259.311890 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
6259.320468 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.5782ms (max=1200ms) -
6259.320468 Get Diagnostic Response Positive response was received. -
6259.320468 Diagnostic response 0x51, 0x01 -
6259.320468 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
36. Wait 5s for diagnostics start: None
6264.320468 1 Waited for 5.000 s -
37. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
6264.320468 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
6264.322074 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.60598ms (max=1000ms) -
6264.322074 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
6264.340929 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=18.8551ms (max=1200ms) -
6264.340929 Get Diagnostic Response Positive response was received. -
6264.340929 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x6C, 0x02, 0x00 -
6264.340929 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
38. Check OCC2 value Expected: OCC2 equal expected value: Failed
6264.340929 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 1 -
6264.340929 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 1 fail
fail
Completion of Test Case
Timestamp Test Step Description Result
1. Wait 10ms: None
6264.350929 1 Waited for 10.000 ms -
2. Send diagnostic request "Clear Diagnostic Information" Expected: Positive response: Passed
6264.352143 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.2147ms (max=1000ms) -
6264.352143 Clear Diagnostic Information Request Clear Diagnostic Information was succesfully transmitted. -
6264.371962 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=19.819ms (max=1200ms) -
6264.371962 Get Diagnostic Response Positive response was received. -
6264.371962 Diagnostic response 0x54 -
6264.371962 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
6264.371962 VT System Cards Configuration General-Purpose Relay Module - M2_VT2820 -
3. Change the state of the relay, Expected: VCC line connected to DUT: Passed
6264.371962 Change Relay State Relay vt2820_channel_13 - Relay 13 state was changed to RELEASED pass
4. Change the state of the relay, Expected: GND line connected to DUT: Passed
6264.371962 Change Relay State Relay vt2820_channel_14 - Relay 14 state was changed to RELEASED pass
5. Set the supply voltage of the DUT, Expected: Voltage = 12.0 V: Passed
5.1. VTS_Set_Power_Supply_Voltage_RangeZeroTo28V: Passed
6264.371962 Set power supply voltage Voltage set properly to 0.000000 V on vt2816_13 channel pass
6. Wait for configuration to be set: None
6264.471962 1 Waited for 100.000 (setup_time_1) ms -
[−] 1.3.4 B183F2A - OCC 4 Total number of failed cycles: Failed
Test case begin: 2024-06-19 16:38:09 (logging timestamp 6264.471962)
Test case end: 2024-06-19 16:41:49 (logging timestamp 6484.307750)

Link (managed by: vTESTstudio Traceability): REQ-90119v4 Support for Operation Cycle Counter 6 - Consecutive number of faulty operation cycles

Link (managed by: vTESTstudio Traceability): DTC 17 - Right Stalk General Signal Failures Signal Stuck In Range

Link (managed by: vTESTstudio Traceability): REQ-90105v4 Compliance to ISO 14229-1

Attributes
Safety Level: QM
Priority: Normal
Type: Automated
[expand test steps] [collapse test steps]
Preparation of Test Case
Timestamp Test Step Description Result
6264.471962 VT System Cards Configuration General-Purpose Relay Module - M2_VT2820 -
6264.471962 VT System Cards Configuration General-Purpose Analog I/O Module - M4_VT2816 -
6264.471962 VT System Cards Configuration General-Purpose Digital I/O Module - M5_VT2848 -
6264.471962 VT System Cards Configuration Network Module - M1_VT6204 -
6264.471962 VT System Cards Configuration Serial Interface Module - M6_VT2710 -
6264.471962 VT System Cards Configuration General-Purpose Relay Module - M2_VT2820 -
1. Change the state of the relay, Expected: VCC line connected to DUT: Passed
6264.471962 Change Relay State Relay vt2820_channel_13 - Relay 13 state was changed to PUSHED pass
2. Change the state of the relay, Expected: GND line connected to DUT: Passed
6264.471962 Change Relay State Relay vt2820_channel_14 - Relay 14 state was changed to PUSHED pass
3. Set the supply voltage of the DUT, Expected: Voltage = 12.0 V: Passed
3.1. VTS_Set_Power_Supply_Voltage_RangeZeroTo28V: Passed
6264.471962 Set power supply voltage Voltage set properly to 12.000000 V on vt2816_13 channel pass
4. Wait for configuration to be set: None
6264.571962 1 Waited for 100.000 (setup_time_1) ms -
5. Wait for start diagnostic: None
6266.971962 1 Waited for 2400.000 (diagnostic_start_time) ms -
Main Part of Test Case
Timestamp Test Step Description Result
1. Send diagnostic request "Clear Diagnostic Information" Expected: Positive response: Passed
6266.973198 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.23509ms (max=1000ms) -
6266.973198 Clear Diagnostic Information Request Clear Diagnostic Information was succesfully transmitted. -
6266.994082 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=20.884ms (max=1200ms) -
6266.994082 Get Diagnostic Response Positive response was received. -
6266.994082 Diagnostic response 0x54 -
6266.994082 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
2. Wait for TRC EN: None
6269.594082 1 Waited for 2600.000 ms -
3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 4" Expected: Positive response: Passed
6269.594082 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x04 -
6269.595413 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.33153ms (max=1000ms) -
6269.595413 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x04 pass
6269.612932 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=17.5188ms (max=1200ms) -
6269.612932 Get Diagnostic Response Positive response was received. -
6269.612932 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50 -
6269.612932 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
4. Check response length Expected: Response length of 6 bytes (data is not available): Passed
6269.612932 Check diagnostic response length Check if length of diagnostic response equals 6 bytes. -
6269.612932 Compare values
[−] Check diagnostic response length
Symbol Op. Reference value Actual Result
Diagnostic response length == 6 6 pass
pass
5. Wait until DTC reached TestPass Limit: None
6280.612932 1 Waited for 11.000 s -
6. Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
6280.612932 Diagnostic request 0x11, 0x01 -
6280.614230 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.29839ms (max=1000ms) -
6280.614230 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
6280.622890 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.6598ms (max=1200ms) -
6280.622890 Get Diagnostic Response Positive response was received. -
6280.622890 Diagnostic response 0x51, 0x01 -
6280.622890 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
7. Wait for start diagnostics: None
6283.022890 1 Waited for 2400.000 (diagnostic_start_time) ms -
8. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 4" Expected: Positive response: Passed
6283.022890 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x04 -
6283.024265 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.37527ms (max=1000ms) -
6283.024265 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x04 pass
6283.044542 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=20.277ms (max=1200ms) -
6283.044542 Get Diagnostic Response Positive response was received. -
6283.044542 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50 -
6283.044542 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
9. Check response length Expected: Response length of 6 bytes (data is not available): Passed
6283.044542 Check diagnostic response length Check if length of diagnostic response equals 6 bytes. -
6283.044542 Compare values
[−] Check diagnostic response length
Symbol Op. Reference value Actual Result
Diagnostic response length == 6 6 pass
pass
10. Wait for TRC EN: None
6285.644542 1 Waited for 2600.000 ms -
11. Change the state of the relay, Expected: Park 1 button is pressed: Passed
6285.644542 Change Relay State Relay vt2820_channel_6 - Relay 6 state was changed to PUSHED pass
12. Change the state of the relay, Expected: Park 2 button is pressed: Passed
6285.644542 Change Relay State Relay vt2820_channel_7 - Relay 7 state was changed to PUSHED pass
13. Wait for close relay: None
6285.649542 1 Waited for 5.000 ms -
14. Check that the SWMRiLvrDiagRiLvrDiag value has been set to 2 within 200s Expected: The signal has been set: Passed
6465.723977 Resume reason Resumed on signal: CAN signal 'SWMRiLvrDiagRiLvrDiag' Elapsed time=180074ms (max=200000ms) -
6465.723977 1
[−] Waited for occurrence of 1 value condition and signal updates.
Symbol Op. Reference value Actual Result
CAN signal 'SWMRiLvrDiagRiLvrDiag' == 2 2 pass
pass
15. Wait 16s until DTC reached TestFail Limit: None
6481.723977 1 Waited for 16.000 s -
16. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x04" Expected: Positive response: Passed
6481.723977 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x04 -
6481.725577 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.59961ms (max=1000ms) -
6481.725577 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x04 pass
6481.744380 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=18.8025ms (max=1200ms) -
6481.744380 Get Diagnostic Response Positive response was received. -
6481.744380 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x2F, 0x04, 0x01 -
6481.744380 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
17. Check OCC4 value Expected: OCC4 equal expected value: Passed
6481.744380 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 1 -
6481.744380 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 1 1 pass
pass
18. Change the state of the relay, Expected: Park 1 button not is pressed: Passed
6481.744380 Change Relay State Relay vt2820_channel_6 - Relay 6 state was changed to RELEASED pass
19. Change the state of the relay, Expected: Park 2 button not is pressed: Passed
6481.744380 Change Relay State Relay vt2820_channel_7 - Relay 7 state was changed to RELEASED pass
20. Wait for open relay: None
6481.754380 1 Waited for 10.000 ms -
21. Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
6481.754380 Diagnostic request 0x11, 0x01 -
6481.755757 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.37736ms (max=1000ms) -
6481.755757 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
6481.764264 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.50669ms (max=1200ms) -
6481.764264 Get Diagnostic Response Positive response was received. -
6481.764264 Diagnostic response 0x51, 0x01 -
6481.764264 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
22. Wait for start diagnostics: None
6484.164264 1 Waited for 2400.000 (diagnostic_start_time) ms -
23. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x04" Expected: Positive response: Passed
6484.164264 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x04 -
6484.165783 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.51983ms (max=1000ms) -
6484.165783 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x04 pass
6484.176587 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=10.8033ms (max=1200ms) -
6484.176587 Get Diagnostic Response Positive response was received. -
6484.176587 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x40 -
6484.176587 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
24. Check OCC4 value Expected: OCC4 equal expected value: Failed
6484.176587 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 1 -
6484.176587 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
6484.176587 Test aborted due to BreakOnFail behavior. -
Completion of Test Case
Timestamp Test Step Description Result
1. Wait 10ms: None
6484.186587 1 Waited for 10.000 ms -
2. Send diagnostic request "Clear Diagnostic Information" Expected: Positive response: Passed
6484.187829 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.24208ms (max=1000ms) -
6484.187829 Clear Diagnostic Information Request Clear Diagnostic Information was succesfully transmitted. -
6484.207750 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=19.9207ms (max=1200ms) -
6484.207750 Get Diagnostic Response Positive response was received. -
6484.207750 Diagnostic response 0x54 -
6484.207750 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
6484.207750 VT System Cards Configuration General-Purpose Relay Module - M2_VT2820 -
3. Change the state of the relay, Expected: VCC line connected to DUT: Passed
6484.207750 Change Relay State Relay vt2820_channel_13 - Relay 13 state was changed to RELEASED pass
4. Change the state of the relay, Expected: GND line connected to DUT: Passed
6484.207750 Change Relay State Relay vt2820_channel_14 - Relay 14 state was changed to RELEASED pass
5. Set the supply voltage of the DUT, Expected: Voltage = 12.0 V: Passed
5.1. VTS_Set_Power_Supply_Voltage_RangeZeroTo28V: Passed
6484.207750 Set power supply voltage Voltage set properly to 0.000000 V on vt2816_13 channel pass
6. Wait for configuration to be set: None
6484.307750 1 Waited for 100.000 (setup_time_1) ms -
[−] 1.3.5 B183F2A - OCC 6 Consecutive number of faulty operation cycles: Failed
Test case begin: 2024-06-19 16:41:49 (logging timestamp 6484.307750)
Test case end: 2024-06-19 16:42:07 (logging timestamp 6502.995374)

Link (managed by: vTESTstudio Traceability): REQ-90119v4 Support for Operation Cycle Counter 6 - Consecutive number of faulty operation cycles

Link (managed by: vTESTstudio Traceability): DTC 17 - Right Stalk General Signal Failures Signal Stuck In Range

Attributes
Safety Level: QM
Priority: Normal
Type: Automated
[expand test steps] [collapse test steps]
Preparation of Test Case
Timestamp Test Step Description Result
6484.307750 VT System Cards Configuration General-Purpose Relay Module - M2_VT2820 -
6484.307750 VT System Cards Configuration General-Purpose Analog I/O Module - M4_VT2816 -
6484.307750 VT System Cards Configuration General-Purpose Digital I/O Module - M5_VT2848 -
6484.307750 VT System Cards Configuration Network Module - M1_VT6204 -
6484.307750 VT System Cards Configuration Serial Interface Module - M6_VT2710 -
6484.307750 VT System Cards Configuration General-Purpose Relay Module - M2_VT2820 -
1. Change the state of the relay, Expected: VCC line connected to DUT: Passed
6484.307750 Change Relay State Relay vt2820_channel_13 - Relay 13 state was changed to PUSHED pass
2. Change the state of the relay, Expected: GND line connected to DUT: Passed
6484.307750 Change Relay State Relay vt2820_channel_14 - Relay 14 state was changed to PUSHED pass
3. Set the supply voltage of the DUT, Expected: Voltage = 12.0 V: Passed
3.1. VTS_Set_Power_Supply_Voltage_RangeZeroTo28V: Passed
6484.307750 Set power supply voltage Voltage set properly to 12.000000 V on vt2816_13 channel pass
4. Wait for configuration to be set: None
6484.407750 1 Waited for 100.000 (setup_time_1) ms -
5. Wait for start diagnostic: None
6486.807750 1 Waited for 2400.000 (diagnostic_start_time) ms -
Main Part of Test Case
Timestamp Test Step Description Result
1. Send diagnostic request "Clear Diagnostic Information" Expected: Positive response: Passed
6486.808998 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.24803ms (max=1000ms) -
6486.808998 Clear Diagnostic Information Request Clear Diagnostic Information was succesfully transmitted. -
6486.822370 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.3721ms (max=1200ms) -
6486.822370 Get Diagnostic Response Positive response was received. -
6486.822370 Diagnostic response 0x54 -
6486.822370 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
2. Wait for TRC EN: None
6489.422370 1 Waited for 2600.000 ms -
3. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 6" Expected: Positive response: Passed
6489.422370 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x06 -
6489.423945 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.57542ms (max=1000ms) -
6489.423945 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x06 pass
6489.440800 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=16.8545ms (max=1200ms) -
6489.440800 Get Diagnostic Response Positive response was received. -
6489.440800 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50 -
6489.440800 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
4. Check response length Expected: Response length of 6 bytes (data is not available): Passed
6489.440800 Check diagnostic response length Check if length of diagnostic response equals 6 bytes. -
6489.440800 Compare values
[−] Check diagnostic response length
Symbol Op. Reference value Actual Result
Diagnostic response length == 6 6 pass
pass
5. Wait for 11s until DTC reached TestPass Limit: None
6500.440800 1 Waited for 11.000 s -
6. Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
6500.440800 Diagnostic request 0x11, 0x01 -
6500.442099 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.29942ms (max=1000ms) -
6500.442099 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
6500.450892 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.79342ms (max=1200ms) -
6500.450892 Get Diagnostic Response Positive response was received. -
6500.450892 Diagnostic response 0x51, 0x01 -
6500.450892 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
7. Wait for start diagnostics: None
6502.850892 1 Waited for 2400.000 (diagnostic_start_time) ms -
8. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x04" Expected: Positive response: Passed
6502.850892 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x06 -
6502.852300 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.40728ms (max=1000ms) -
6502.852300 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x06 pass
6502.864232 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=11.9322ms (max=1200ms) -
6502.864232 Get Diagnostic Response Positive response was received. -
6502.864232 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x50 -
6502.864232 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
9. Check OCC6 value Expected: OCC6 equal expected value: Failed
6502.864232 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 0 -
6502.864232 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 6
byte_index = 7
fail
6502.864232 Test aborted due to BreakOnFail behavior. -
Completion of Test Case
Timestamp Test Step Description Result
1. Wait 10ms: None
6502.874232 1 Waited for 10.000 ms -
2. Send diagnostic request "Clear Diagnostic Information" Expected: Positive response: Passed
6502.875328 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.09608ms (max=1000ms) -
6502.875328 Clear Diagnostic Information Request Clear Diagnostic Information was succesfully transmitted. -
6502.895374 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=20.0462ms (max=1200ms) -
6502.895374 Get Diagnostic Response Positive response was received. -
6502.895374 Diagnostic response 0x54 -
6502.895374 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
6502.895374 VT System Cards Configuration General-Purpose Relay Module - M2_VT2820 -
3. Change the state of the relay, Expected: VCC line connected to DUT: Passed
6502.895374 Change Relay State Relay vt2820_channel_13 - Relay 13 state was changed to RELEASED pass
4. Change the state of the relay, Expected: GND line connected to DUT: Passed
6502.895374 Change Relay State Relay vt2820_channel_14 - Relay 14 state was changed to RELEASED pass
5. Set the supply voltage of the DUT, Expected: Voltage = 12.0 V: Passed
5.1. VTS_Set_Power_Supply_Voltage_RangeZeroTo28V: Passed
6502.895374 Set power supply voltage Voltage set properly to 0.000000 V on vt2816_13 channel pass
6. Wait for configuration to be set: None
6502.995374 1 Waited for 100.000 (setup_time_1) ms -
[−] 1.3.6 B183F2A DTC Storage : Failed
Test case begin: 2024-06-19 16:42:07 (logging timestamp 6502.995374)
Test case end: 2024-06-19 16:45:45 (logging timestamp 6720.827232)

Link (managed by: vTESTstudio Traceability): REQ-90065v4 DTC storage time

Link (managed by: vTESTstudio Traceability): REQ-90129v4 Storage of DTC information

Link (managed by: vTESTstudio Traceability): REQ-90130v4 Temporary DTC Storage in short-term memory

Link (managed by: vTESTstudio Traceability): REQ-90131v4 DTC Storage time

Link (managed by: vTESTstudio Traceability): REQ-90132v4 Transfer of DTC information to long-term memory

Link (managed by: vTESTstudio Traceability): DTC 17 - Right Stalk General Signal Failures Signal Stuck In Range

Attributes
Safety Level: QM
Priority: Normal
Type: Automated
[expand test steps] [collapse test steps]
Preparation of Test Case
Timestamp Test Step Description Result
6502.995374 VT System Cards Configuration General-Purpose Relay Module - M2_VT2820 -
6502.995374 VT System Cards Configuration General-Purpose Analog I/O Module - M4_VT2816 -
6502.995374 VT System Cards Configuration General-Purpose Digital I/O Module - M5_VT2848 -
6502.995374 VT System Cards Configuration Network Module - M1_VT6204 -
6502.995374 VT System Cards Configuration Serial Interface Module - M6_VT2710 -
6502.995374 VT System Cards Configuration General-Purpose Relay Module - M2_VT2820 -
1. Change the state of the relay, Expected: VCC line connected to DUT: Passed
6502.995374 Change Relay State Relay vt2820_channel_13 - Relay 13 state was changed to PUSHED pass
2. Change the state of the relay, Expected: GND line connected to DUT: Passed
6502.995374 Change Relay State Relay vt2820_channel_14 - Relay 14 state was changed to PUSHED pass
3. Set the supply voltage of the DUT, Expected: Voltage = 12.0 V: Passed
3.1. VTS_Set_Power_Supply_Voltage_RangeZeroTo28V: Passed
6502.995374 Set power supply voltage Voltage set properly to 12.000000 V on vt2816_13 channel pass
4. Wait for configuration to be set: None
6503.095374 1 Waited for 100.000 (setup_time_1) ms -
5. Wait for start diagnostic: None
6505.495374 1 Waited for 2400.000 (diagnostic_start_time) ms -
6. Send diagnostic request "Clear Diagnostic Information" Expected: Positive response: Passed
6505.496674 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.30017ms (max=1000ms) -
6505.496674 Clear Diagnostic Information Request Clear Diagnostic Information was succesfully transmitted. -
6505.511692 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=15.0181ms (max=1200ms) -
6505.511692 Get Diagnostic Response Positive response was received. -
6505.511692 Diagnostic response 0x54 -
6505.511692 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
7. Wait: None
6521.511692 1 Waited for 16.000 s -
Main Part of Test Case
Timestamp Test Step Description Result
1. Change the state of the relay, Expected: Park 1 button is pressed: Passed
6521.511692 Change Relay State Relay vt2820_channel_6 - Relay 6 state was changed to PUSHED pass
2. Change the state of the relay, Expected: Park 2 button is pressed: Passed
6521.511692 Change Relay State Relay vt2820_channel_7 - Relay 7 state was changed to PUSHED pass
3. Wait for close relay: None
6521.516692 1 Waited for 5.000 ms -
4. Check that the SWMRiLvrDiagRiLvrDiag value has been set to 2 within 200s Expected: The signal has been set: Passed
6701.584986 Resume reason Resumed on signal: CAN signal 'SWMRiLvrDiagRiLvrDiag' Elapsed time=180068ms (max=200000ms) -
6701.584986 1
[−] Waited for occurrence of 1 value condition and signal updates.
Symbol Op. Reference value Actual Result
CAN signal 'SWMRiLvrDiagRiLvrDiag' == 2 2 pass
pass
5. Wait 16s for DTC reached TestFail Limit: None
6717.584986 1 Waited for 16.000 s -
6. Send diagnostic request "Report DTC By status Mask 0xFF" Expected: Positive response : Passed
6717.584986 Diagnostic request 0x19, 0x02, 0xFF -
6717.586405 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.41892ms (max=1000ms) -
6717.586405 Report DTC By Status Mask Request Report DTC By Status Mask was succesfully transmitted with status mask: 0xFF pass
6717.590532 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=4.12647ms (max=1200ms) -
6717.590532 Get Diagnostic Response Positive response was received. -
6717.590532 Diagnostic response 0x59, 0x02, 0xFF, 0x95, 0x4F, 0x96, 0x2F, 0x98, 0x3F, 0x2A, 0x2F, 0xF0, 0x03, 0x62, 0x27, 0xEF, 0x00, 0x55, 0x50, 0xE1, 0x01, 0x56, 0x50, 0x06, 0x06, 0x47, 0x50, 0x06, 0x06, 0x48, 0x50 -
6717.590532 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
7. Check DTC status Expected: DTC active, Bits 0,1,2,3,5 set to 1 in hex 0x2F: Passed
6717.590532 Compare values
[−] Check DTC Status Mask
Symbol Op. Reference value Actual Result
Expected status mask for DTC 0x983F2A: 0x2F Received: 0x2F == 47 47 pass
pass
8. Wait 10ms: None
6717.600532 1 Waited for 10.000 ms -
9. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
6717.600532 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
6717.602052 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.52002ms (max=1000ms) -
6717.602052 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
6717.620382 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=18.3301ms (max=1200ms) -
6717.620382 Get Diagnostic Response Positive response was received. -
6717.620382 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x2F, 0x01, 0x00 -
6717.620382 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
10. Check OCC1 value Expected: OCC1 equal expected value: Passed
6717.620382 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 0 -
6717.620382 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 0 pass
pass
11. Wait: None
6717.630382 1 Waited for 10.000 ms -
12. Wait 10ms: None
6717.640382 1 Waited for 10.000 ms -
13. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
6717.640382 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
6717.641950 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.56781ms (max=1000ms) -
6717.641950 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
6717.660027 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=18.0775ms (max=1200ms) -
6717.660027 Get Diagnostic Response Positive response was received. -
6717.660027 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x2F, 0x02, 0x00 -
6717.660027 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
14. Check OCC2 value Expected: OCC2 equal expected value: Passed
6717.660027 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 0 -
6717.660027 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 0 pass
pass
15. wait 10ms: None
6717.670027 1 Waited for 10.000 ms -
16. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x04" Expected: Positive response: Passed
6717.670027 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x04 -
6717.671650 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.6227ms (max=1000ms) -
6717.671650 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x04 pass
6717.690015 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=18.3656ms (max=1200ms) -
6717.690015 Get Diagnostic Response Positive response was received. -
6717.690015 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x2F, 0x04, 0x01 -
6717.690015 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
17. Check OCC4 value Expected: OCC4 equal expected value: Passed
6717.690015 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 1 -
6717.690015 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 1 1 pass
pass
18. wait 10ms: None
6717.700015 1 Waited for 10.000 ms -
19. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 30" Expected: Positive response: Failed
6717.700015 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x1E -
6717.701622 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.60611ms (max=1000ms) -
6717.701622 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x1E pass
6717.719915 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=18.2932ms (max=1200ms) -
6717.719915 Get Diagnostic Response Negative response was received. -
6717.719915 Diagnostic response 0x7F, 0x19, 0x31 -
6717.719915 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == negative response positive response fail
fail
20. Check SI30 value Expected: SI30 equal expected value: Failed
6717.719915 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 128 -
6717.719915 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 3
byte_index = 7
fail
21. Wait for the remaining time to move data to non-volatile memory: None
6718.079915 1 Waited for 360.000 ms -
22. Change the state of the relay, Expected: Park 1 button not is pressed: Passed
6718.079915 Change Relay State Relay vt2820_channel_6 - Relay 6 state was changed to RELEASED pass
23. Change the state of the relay, Expected: Park 2 button not is pressed: Passed
6718.079915 Change Relay State Relay vt2820_channel_7 - Relay 7 state was changed to RELEASED pass
24. Wait for open relay: None
6718.089915 1 Waited for 10.000 ms -
25. Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
6718.089915 Diagnostic request 0x11, 0x01 -
6718.091230 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.31494ms (max=1000ms) -
6718.091230 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
6718.099948 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.71872ms (max=1200ms) -
6718.099948 Get Diagnostic Response Positive response was received. -
6718.099948 Diagnostic response 0x51, 0x01 -
6718.099948 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
26. Wait for the diagnostics to start: None
6720.499948 1 Waited for 2400.000 (diagnostic_start_time) ms -
27. Send diagnostic request "Report DTC By status Mask 0xFF" Expected: Positive response : Passed
6720.499948 Diagnostic request 0x19, 0x02, 0xFF -
6720.501425 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.47686ms (max=1000ms) -
6720.501425 Report DTC By Status Mask Request Report DTC By Status Mask was succesfully transmitted with status mask: 0xFF pass
6720.519538 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=18.1132ms (max=1200ms) -
6720.519538 Get Diagnostic Response Positive response was received. -
6720.519538 Diagnostic response 0x59, 0x02, 0xFF, 0x95, 0x4F, 0x19, 0x40, 0x95, 0x4F, 0x49, 0x40, 0x95, 0x4F, 0x96, 0x6D, 0x98, 0x2F, 0x2A, 0x40, 0x98, 0x2F, 0x24, 0x40, 0x98, 0x2F, 0x29, 0x40, 0x98, 0x2F, 0x49, 0x40, 0x98, 0x3F.. -
6720.519538 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
28. Check DTC status Expected: Bits 0,2,3,5,6 shell be set to 1 in hex 0x6D: Passed
6720.519538 Compare values
[−] Check DTC Status Mask
Symbol Op. Reference value Actual Result
Expected status mask for DTC 0x983F2A: 0x6D Received: 0x6D == 109 109 pass
pass
29. Wait 10ms: None
6720.529538 1 Waited for 10.000 ms -
30. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 1" Expected: Positive response: Passed
6720.529538 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x01 -
6720.531179 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.64013ms (max=1000ms) -
6720.531179 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x01 pass
6720.545182 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=14.0031ms (max=1200ms) -
6720.545182 Get Diagnostic Response Positive response was received. -
6720.545182 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x6D, 0x01, 0x00 -
6720.545182 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
31. Check OCC1 value Expected: OCC1 equal expected value: Passed
6720.545182 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 0 -
6720.545182 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 0 pass
pass
32. Wait: None
6720.555182 1 Waited for 10.000 ms -
33. Wait 10ms: None
6720.565182 1 Waited for 10.000 ms -
34. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x02" Expected: Positive response: Passed
6720.565182 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x02 -
6720.566576 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.39434ms (max=1000ms) -
6720.566576 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x02 pass
6720.585191 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=18.615ms (max=1200ms) -
6720.585191 Get Diagnostic Response Positive response was received. -
6720.585191 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x6D, 0x02, 0x00 -
6720.585191 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
35. Check OCC2 value Expected: OCC2 equal expected value: Passed
6720.585191 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 0 -
6720.585191 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 0 0 pass
pass
36. wait 10ms: None
6720.595191 1 Waited for 10.000 ms -
37. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x04" Expected: Positive response: Passed
6720.595191 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x04 -
6720.596647 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.45588ms (max=1000ms) -
6720.596647 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x04 pass
6720.615155 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=18.5085ms (max=1200ms) -
6720.615155 Get Diagnostic Response Positive response was received. -
6720.615155 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x6D, 0x04, 0x01 -
6720.615155 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
38. Check OCC4 value Expected: OCC4 equal expected value: Passed
6720.615155 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 1 -
6720.615155 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 1 1 pass
pass
39. wait 10ms: None
6720.625155 1 Waited for 10.000 ms -
40. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 0x04" Expected: Positive response: Passed
6720.625155 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x06 -
6720.626577 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.4212ms (max=1000ms) -
6720.626577 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x06 pass
6720.645159 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=18.5821ms (max=1200ms) -
6720.645159 Get Diagnostic Response Positive response was received. -
6720.645159 Diagnostic response 0x59, 0x06, 0x98, 0x3F, 0x2A, 0x6D, 0x06, 0x01 -
6720.645159 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
41. Check OCC6 value Expected: OCC6 equal expected value: Passed
6720.645159 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 1 -
6720.645159 Compare values
[−] Check byte in diagnostic response
Symbol Op. Reference value Actual Result
Diagnostic response byte #7 == 1 1 pass
pass
42. wait 10ms: None
6720.655159 1 Waited for 10.000 ms -
43. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 30" Expected: Positive response: Failed
6720.655159 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x1E -
6720.656588 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.42901ms (max=1000ms) -
6720.656588 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x1E pass
6720.675014 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=18.4261ms (max=1200ms) -
6720.675014 Get Diagnostic Response Negative response was received. -
6720.675014 Diagnostic response 0x7F, 0x19, 0x31 -
6720.675014 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == negative response positive response fail
fail
44. Check SI30 value Expected: SI30 equal expected value: Failed
6720.675014 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 8 -
6720.675014 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 3
byte_index = 7
fail
Completion of Test Case
Timestamp Test Step Description Result
1. Clear DTC : Failed
6720.677232 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=2.21787ms (max=1000ms) -
6720.677232 Clear Diagnostic Information Request Clear Diagnostic Information was succesfully transmitted. -
6720.827232 Resume reason Resumed on Communication error with 'SWM' Elapsed time=150ms (max=1200ms) -
6720.827232 Get Diagnostic Response No diagnostic response was received. -
6720.827232 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == no response positive response fail
fail
[−] 1.3.7 B183F2A - SI 30 : Failed
Test case begin: 2024-06-19 16:45:45 (logging timestamp 6720.827232)
Test case end: 2024-06-19 16:56:08 (logging timestamp 7343.341884)

Link (managed by: vTESTstudio Traceability): REQ-90122v4 Support for DTC status indicator 30

Link (managed by: vTESTstudio Traceability): REQ-90123v4 Support for DTC status indicator 30, AgedDTC

Link (managed by: vTESTstudio Traceability): REQ-90124v4 Support for DTC status indicator 30, SymptomSinceLastClear

Link (managed by: vTESTstudio Traceability): REQ-90125v4 Support for DTC status indicator 30, WarningIndicatorRequestedSinceLastClear

Link (managed by: vTESTstudio Traceability): REQ-90126v5 Support for DTC status indicator 30, OBDRelatedDTC

Link (managed by: vTESTstudio Traceability): REQ-90127v4 Support for DTC status indicator 30, testFailedSinceLastClear Aged

Link (managed by: vTESTstudio Traceability): DTC 17 - Right Stalk General Signal Failures Signal Stuck In Range

Attributes
Safety Level: QM
Priority: Normal
Type: Automated
[expand test steps] [collapse test steps]
Preparation of Test Case
Timestamp Test Step Description Result
6720.827232 VT System Cards Configuration General-Purpose Relay Module - M2_VT2820 -
6720.827232 VT System Cards Configuration General-Purpose Analog I/O Module - M4_VT2816 -
6720.827232 VT System Cards Configuration General-Purpose Digital I/O Module - M5_VT2848 -
6720.827232 VT System Cards Configuration Network Module - M1_VT6204 -
6720.827232 VT System Cards Configuration Serial Interface Module - M6_VT2710 -
6720.827232 VT System Cards Configuration General-Purpose Relay Module - M2_VT2820 -
1. Change the state of the relay, Expected: VCC line connected to DUT: Passed
6720.827232 Change Relay State Relay vt2820_channel_13 - Relay 13 state was changed to PUSHED pass
2. Change the state of the relay, Expected: GND line connected to DUT: Passed
6720.827232 Change Relay State Relay vt2820_channel_14 - Relay 14 state was changed to PUSHED pass
3. Set the supply voltage of the DUT, Expected: Voltage = 12.0 V: Passed
3.1. VTS_Set_Power_Supply_Voltage_RangeZeroTo28V: Passed
6720.827232 Set power supply voltage Voltage set properly to 12.000000 V on vt2816_13 channel pass
4. Wait for configuration to be set: None
6720.927232 1 Waited for 100.000 (setup_time_1) ms -
5. Wait for start diagnostic: None
6723.327232 1 Waited for 2400.000 (diagnostic_start_time) ms -
6. Send diagnostic request "Clear Diagnostic Information" Expected: Positive response: Passed
6723.328365 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.13383ms (max=1000ms) -
6723.328365 Clear Diagnostic Information Request Clear Diagnostic Information was succesfully transmitted. -
6723.346529 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=18.164ms (max=1200ms) -
6723.346529 Get Diagnostic Response Positive response was received. -
6723.346529 Diagnostic response 0x54 -
6723.346529 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
7. Wait: None
6739.346529 1 Waited for 16.000 s -
Main Part of Test Case
Timestamp Test Step Description Result
1. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 30" Expected: Positive response: Failed
6739.346529 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x1E -
6739.348020 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.49022ms (max=1000ms) -
6739.348020 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x1E pass
6739.360056 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=12.0367ms (max=1200ms) -
6739.360056 Get Diagnostic Response Negative response was received. -
6739.360056 Diagnostic response 0x7F, 0x19, 0x31 -
6739.360056 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == negative response positive response fail
fail
2. Check response length Expected: Response length of 6 bytes (data is not available): Failed
6739.360056 Check diagnostic response length Check if length of diagnostic response equals 6 bytes. -
6739.360056 Compare values
[−] Check diagnostic response length
Symbol Op. Reference value Actual Result
Diagnostic response length == 3 6 fail
fail
3. Change the state of the relay, Expected: Park 1 button is pressed: Passed
6739.360056 Change Relay State Relay vt2820_channel_6 - Relay 6 state was changed to PUSHED pass
4. Change the state of the relay, Expected: Park 2 button is pressed: Passed
6739.360056 Change Relay State Relay vt2820_channel_7 - Relay 7 state was changed to PUSHED pass
5. Wait for close relay: None
6739.365056 1 Waited for 5.000 ms -
6. Check that the SWMRiLvrDiagRiLvrDiag value has been set to 2 within 200s Expected: The signal has been set: Passed
6919.434650 Resume reason Resumed on signal: CAN signal 'SWMRiLvrDiagRiLvrDiag' Elapsed time=180070ms (max=200000ms) -
6919.434650 1
[−] Waited for occurrence of 1 value condition and signal updates.
Symbol Op. Reference value Actual Result
CAN signal 'SWMRiLvrDiagRiLvrDiag' == 2 2 pass
pass
7. Wait for 9s until the DTC is in range unconfirmedDTCLimit to testFail Limit: None
6928.434650 1 Waited for 9.000 s -
8. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 30" Expected: Positive response: Failed
6928.434650 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x1E -
6928.436256 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.60553ms (max=1000ms) -
6928.436256 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x1E pass
6928.449839 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.5834ms (max=1200ms) -
6928.449839 Get Diagnostic Response Negative response was received. -
6928.449839 Diagnostic response 0x7F, 0x19, 0x31 -
6928.449839 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == negative response positive response fail
fail
9. Check SI30 value Expected: SI30 equal expected value: Failed
6928.449839 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 16 -
6928.449839 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 3
byte_index = 7
fail
10. Change the state of the relay, Expected: Park 1 button not is pressed: Passed
6928.449839 Change Relay State Relay vt2820_channel_6 - Relay 6 state was changed to RELEASED pass
11. Change the state of the relay, Expected: Park 2 button not is pressed: Passed
6928.449839 Change Relay State Relay vt2820_channel_7 - Relay 7 state was changed to RELEASED pass
12. Wait for open relay: None
6928.459839 1 Waited for 10.000 ms -
13. Wait 6s for the FDC value to be negative: None
6934.459839 1 Waited for 6.000 s -
14. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 30" Expected: Positive response: Failed
6934.459839 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x1E -
6934.461453 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.61359ms (max=1000ms) -
6934.461453 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x1E pass
6934.479828 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=18.375ms (max=1200ms) -
6934.479828 Get Diagnostic Response Negative response was received. -
6934.479828 Diagnostic response 0x7F, 0x19, 0x31 -
6934.479828 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == negative response positive response fail
fail
15. Check SI30 value Expected: SI30 equal expected value: Failed
6934.479828 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 0 -
6934.479828 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 3
byte_index = 7
fail
16. Change the state of the relay, Expected: Park 1 button is pressed: Passed
6934.479828 Change Relay State Relay vt2820_channel_6 - Relay 6 state was changed to PUSHED pass
17. Change the state of the relay, Expected: Park 2 button is pressed: Passed
6934.479828 Change Relay State Relay vt2820_channel_7 - Relay 7 state was changed to PUSHED pass
18. Wait for close relay: None
6934.484828 1 Waited for 5.000 ms -
19. Check that the SWMRiLvrDiagRiLvrDiag value has been set to 2 within 200s Expected: The signal has been set: Passed
7114.534675 Resume reason Resumed on signal: CAN signal 'SWMRiLvrDiagRiLvrDiag' Elapsed time=180050ms (max=200000ms) -
7114.534675 1
[−] Waited for occurrence of 1 value condition and signal updates.
Symbol Op. Reference value Actual Result
CAN signal 'SWMRiLvrDiagRiLvrDiag' == 2 2 pass
pass
20. Wait for 16s until the DTC reach testFail Limit: None
7130.534675 1 Waited for 16.000 s -
21. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 30" Expected: Positive response: Failed
7130.534675 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x1E -
7130.536229 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.5547ms (max=1000ms) -
7130.536229 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x1E pass
7130.549590 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.3611ms (max=1200ms) -
7130.549590 Get Diagnostic Response Negative response was received. -
7130.549590 Diagnostic response 0x7F, 0x19, 0x31 -
7130.549590 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == negative response positive response fail
fail
22. Check SI30 value Expected: SI30 equal expected value: Failed
7130.549590 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 128 -
7130.549590 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 3
byte_index = 7
fail
23. Change the state of the relay, Expected: Park 1 button not is pressed: Passed
7130.549590 Change Relay State Relay vt2820_channel_6 - Relay 6 state was changed to RELEASED pass
24. Change the state of the relay, Expected: Park 2 button not is pressed: Passed
7130.549590 Change Relay State Relay vt2820_channel_7 - Relay 7 state was changed to RELEASED pass
25. Wait for open relay: None
7130.559590 1 Waited for 10.000 ms -
26. Wait 10ms: None
7130.569590 1 Waited for 10.000 ms -
27. Send diagnostic request "ECU hard reset" Expected: Positive response: Passed
7130.569590 Diagnostic request 0x11, 0x01 -
7130.570912 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.32198ms (max=1000ms) -
7130.570912 Send diagnostic request to SCCM ECU Reset - Hard Reset (0x11 0x01) -
7130.579588 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.6758ms (max=1200ms) -
7130.579588 Get Diagnostic Response Positive response was received. -
7130.579588 Diagnostic response 0x51, 0x01 -
7130.579588 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
28. Wait 16s for DTC reach TestPass Limit: None
7146.579588 1 Waited for 16.000 s -
29. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 30" Expected: Positive response: Failed
7146.579588 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x1E -
7146.581136 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.54772ms (max=1000ms) -
7146.581136 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x1E pass
7146.600967 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=19.8312ms (max=1200ms) -
7146.600967 Get Diagnostic Response Negative response was received. -
7146.600967 Diagnostic response 0x7F, 0x19, 0x31 -
7146.600967 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == negative response positive response fail
fail
30. Check SI30 value Expected: SI30 equal expected value: Failed
7146.600967 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 8 -
7146.600967 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 3
byte_index = 7
fail
31. Change the state of the relay, Expected: Park 1 button is pressed: Passed
7146.600967 Change Relay State Relay vt2820_channel_6 - Relay 6 state was changed to PUSHED pass
32. Change the state of the relay, Expected: Park 2 button is pressed: Passed
7146.600967 Change Relay State Relay vt2820_channel_7 - Relay 7 state was changed to PUSHED pass
33. Wait for close relay: None
7146.605967 1 Waited for 5.000 ms -
34. Check that the SWMRiLvrDiagRiLvrDiag value has been set to 2 within 200s Expected: The signal has been set: Passed
7326.670509 Resume reason Resumed on signal: CAN signal 'SWMRiLvrDiagRiLvrDiag' Elapsed time=180065ms (max=200000ms) -
7326.670509 1
[−] Waited for occurrence of 1 value condition and signal updates.
Symbol Op. Reference value Actual Result
CAN signal 'SWMRiLvrDiagRiLvrDiag' == 2 2 pass
pass
35. Wait for 9s until the DTC is in range unconfirmedDTCLimit to testFail Limit: None
7335.670509 1 Waited for 9.000 s -
36. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 30" Expected: Positive response: Failed
7335.670509 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x1E -
7335.672139 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.62942ms (max=1000ms) -
7335.672139 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x1E pass
7335.690752 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=18.6131ms (max=1200ms) -
7335.690752 Get Diagnostic Response Negative response was received. -
7335.690752 Diagnostic response 0x7F, 0x19, 0x31 -
7335.690752 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == negative response positive response fail
fail
37. Check SI30 value Expected: SI30 equal expected value: Failed
7335.690752 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 24 -
7335.690752 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 3
byte_index = 7
fail
38. Wait 7s for DTC reach testFail Limit: None
7342.690752 1 Waited for 7.000 s -
39. Change the state of the relay, Expected: Park 1 button not is pressed: Passed
7342.690752 Change Relay State Relay vt2820_channel_6 - Relay 6 state was changed to RELEASED pass
40. Change the state of the relay, Expected: Park 2 button not is pressed: Passed
7342.690752 Change Relay State Relay vt2820_channel_7 - Relay 7 state was changed to RELEASED pass
41. Wait for open relay: None
7342.700752 1 Waited for 10.000 ms -
42. Send diagnostic request "ReportDTCExtendedDataRecordByDTCNumber 30" Expected: Positive response: Failed
7342.700752 Diagnostic request 0x19, 0x06, 0x98, 0x3F, 0x2A, 0x1E -
7342.702228 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.4767ms (max=1000ms) -
7342.702228 Report DTC Extended Data Record by DTC Number Request Report DTC Snapshot Record by DTC Number was succesfully transmitted with DTC code: 0x983F2A and snapshot record number: 0x1E pass
7342.720742 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=18.5134ms (max=1200ms) -
7342.720742 Get Diagnostic Response Negative response was received. -
7342.720742 Diagnostic response 0x7F, 0x19, 0x31 -
7342.720742 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == negative response positive response fail
fail
43. Check SI30 value Expected: SI30 equal expected value: Failed
7342.720742 Check byte in diagnostic response Check byte #7 of diagnostic response. Expected value: 128 -
7342.720742 Check byte in diagnostic response Parameter 'byte_index' value is out of diagnostic response range.
Diagnostic response length = 3
byte_index = 7
fail
Completion of Test Case
Timestamp Test Step Description Result
1. Wait 500ms: None
7343.220742 1 Waited for 500.000 ms -
2. Send diagnostic request "Clear Diagnostic Information" Expected: Positive response: Passed
7343.222011 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.26895ms (max=1000ms) -
7343.222011 Clear Diagnostic Information Request Clear Diagnostic Information was succesfully transmitted. -
7343.241884 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=19.8734ms (max=1200ms) -
7343.241884 Get Diagnostic Response Positive response was received. -
7343.241884 Diagnostic response 0x54 -
7343.241884 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
7343.241884 VT System Cards Configuration General-Purpose Relay Module - M2_VT2820 -
3. Change the state of the relay, Expected: VCC line connected to DUT: Passed
7343.241884 Change Relay State Relay vt2820_channel_13 - Relay 13 state was changed to RELEASED pass
4. Change the state of the relay, Expected: GND line connected to DUT: Passed
7343.241884 Change Relay State Relay vt2820_channel_14 - Relay 14 state was changed to RELEASED pass
5. Set the supply voltage of the DUT, Expected: Voltage = 12.0 V: Passed
5.1. VTS_Set_Power_Supply_Voltage_RangeZeroTo28V: Passed
7343.241884 Set power supply voltage Voltage set properly to 0.000000 V on vt2816_13 channel pass
6. Wait for configuration to be set: None
7343.341884 1 Waited for 100.000 (setup_time_1) ms -
[−] 1.3.8 B183F2A - TRC: Failed
Test case begin: 2024-06-19 16:56:08 (logging timestamp 7343.341884)
Test case end: 2024-06-19 17:00:05 (logging timestamp 7581.106698)

Link (managed by: vTESTstudio Traceability): REQ-90022v4 Generic Test Run Criteria - enable criteria

Link (managed by: vTESTstudio Traceability): REQ-90023v4 Generic Test Run Criteria - low power inhibit criteria

Link (managed by: vTESTstudio Traceability): DTC 17 - Right Stalk General Signal Failures Signal Stuck In Range

Attributes
Safety Level: QM
Priority: Normal
Type: Automated
[expand test steps] [collapse test steps]
Preparation of Test Case
Timestamp Test Step Description Result
7343.341884 VT System Cards Configuration General-Purpose Relay Module - M2_VT2820 -
7343.341884 VT System Cards Configuration General-Purpose Analog I/O Module - M4_VT2816 -
7343.341884 VT System Cards Configuration General-Purpose Digital I/O Module - M5_VT2848 -
7343.341884 VT System Cards Configuration Network Module - M1_VT6204 -
7343.341884 VT System Cards Configuration Serial Interface Module - M6_VT2710 -
7343.341884 VT System Cards Configuration General-Purpose Relay Module - M2_VT2820 -
1. Change the state of the relay, Expected: VCC line connected to DUT: Passed
7343.341884 Change Relay State Relay vt2820_channel_13 - Relay 13 state was changed to PUSHED pass
2. Change the state of the relay, Expected: GND line connected to DUT: Passed
7343.341884 Change Relay State Relay vt2820_channel_14 - Relay 14 state was changed to PUSHED pass
3. Set the supply voltage of the DUT, Expected: Voltage = 12.0 V: Passed
3.1. VTS_Set_Power_Supply_Voltage_RangeZeroTo28V: Passed
7343.341884 Set power supply voltage Voltage set properly to 12.000000 V on vt2816_13 channel pass
4. Wait for configuration to be set: None
7343.441884 1 Waited for 100.000 (setup_time_1) ms -
5. Wait for start diagnostic: None
7345.841884 1 Waited for 2400.000 (diagnostic_start_time) ms -
Main Part of Test Case
Timestamp Test Step Description Result
1. Set power supply voltage to 12V: Passed
1.1. VTS_Set_Power_Supply_Voltage_RangeZeroTo28V: Passed
7345.841884 Set power supply voltage Voltage set properly to 7.000000 V on vt2816_13 channel pass
2. Send diagnostic request "Clear Diagnostic Information" Expected: Positive response: Passed
7345.843518 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.63433ms (max=1000ms) -
7345.843518 Clear Diagnostic Information Request Clear Diagnostic Information was succesfully transmitted. -
7345.856986 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=13.4671ms (max=1200ms) -
7345.856986 Get Diagnostic Response Positive response was received. -
7345.856986 Diagnostic response 0x54 -
7345.856986 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
3. Wait for TRC EN: None
7348.356986 1 Waited for 2500.000 ms -
4. Send diagnostic request "Report DTC By status Mask 0xFF" Expected: Positive response : Passed
7348.356986 Diagnostic request 0x19, 0x02, 0xFF -
7348.358357 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.37142ms (max=1000ms) -
7348.358357 Report DTC By Status Mask Request Report DTC By Status Mask was succesfully transmitted with status mask: 0xFF pass
7348.380174 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=21.8167ms (max=1200ms) -
7348.380174 Get Diagnostic Response Positive response was received. -
7348.380174 Diagnostic response 0x59, 0x02, 0xFF, 0x95, 0x4F, 0x19, 0x50, 0x95, 0x4F, 0x49, 0x50, 0x95, 0x4F, 0x96, 0x50, 0x98, 0x2F, 0x2A, 0x50, 0x98, 0x2F, 0x24, 0x50, 0x98, 0x2F, 0x29, 0x50, 0x98, 0x2F, 0x49, 0x50, 0x98, 0x3F.. -
7348.380174 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
5. Check DTC status Expected: Only bit 4 & 6 set in hex 0x50 : Passed
7348.380174 Compare values
[−] Check DTC Status Mask
Symbol Op. Reference value Actual Result
Expected status mask for DTC 0x983F2A: 0x50 Received: 0x50 == 80 80 pass
pass
6. Wait 6s: None
7354.380174 1 Waited for 6.000 s -
7. Set power supply voltage to 8.75V: Passed
7.1. VTS_Set_Power_Supply_Voltage_RangeZeroTo28V: Passed
7354.380174 Set power supply voltage Voltage set properly to 8.750000 V on vt2816_13 channel pass
8. Wait 10s: None
7364.380174 1 Waited for 10.000 s -
9. Send diagnostic request "Report DTC By status Mask 0xFF" Expected: Positive response : Passed
7364.380174 Diagnostic request 0x19, 0x02, 0xFF -
7364.381558 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.38397ms (max=1000ms) -
7364.381558 Report DTC By Status Mask Request Report DTC By Status Mask was succesfully transmitted with status mask: 0xFF pass
7364.400156 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=18.598ms (max=1200ms) -
7364.400156 Get Diagnostic Response Positive response was received. -
7364.400156 Diagnostic response 0x59, 0x02, 0xFF, 0x95, 0x4F, 0x19, 0x50, 0x95, 0x4F, 0x49, 0x50, 0x95, 0x4F, 0x96, 0x50, 0x98, 0x2F, 0x2A, 0x50, 0x98, 0x2F, 0x24, 0x50, 0x98, 0x2F, 0x29, 0x50, 0x98, 0x2F, 0x49, 0x50, 0x98, 0x3F.. -
7364.400156 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
10. Check DTC status Expected: Only bit 4 & 6 set in hex 0x50 : Passed
7364.400156 Compare values
[−] Check DTC Status Mask
Symbol Op. Reference value Actual Result
Expected status mask for DTC 0x983F2A: 0x50 Received: 0x50 == 80 80 pass
pass
11. Set power supply voltage to 9.25V: Passed
11.1. VTS_Set_Power_Supply_Voltage_RangeZeroTo28V: Passed
7364.400156 Set power supply voltage Voltage set properly to 9.250000 V on vt2816_13 channel pass
12. Wait 10s for DTC reached TestPass Limit: None
7374.400156 1 Waited for 10.000 s -
13. Send diagnostic request "Report DTC By status Mask 0xFF" Expected: Positive response : Passed
7374.400156 Diagnostic request 0x19, 0x02, 0xFF -
7374.401594 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.43792ms (max=1000ms) -
7374.401594 Report DTC By Status Mask Request Report DTC By Status Mask was succesfully transmitted with status mask: 0xFF pass
7374.419981 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=18.387ms (max=1200ms) -
7374.419981 Get Diagnostic Response Positive response was received. -
7374.419981 Diagnostic response 0x59, 0x02, 0xFF, 0x95, 0x4F, 0x19, 0x50, 0x95, 0x4F, 0x49, 0x50, 0x95, 0x4F, 0x96, 0x50, 0x98, 0x2F, 0x2A, 0x50, 0x98, 0x2F, 0x24, 0x50, 0x98, 0x2F, 0x29, 0x50, 0x98, 0x2F, 0x49, 0x50, 0x98, 0x3F.. -
7374.419981 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
14. Check if the DTC is absent in response Expected: DTC B183F2A not reported in diagnostic response: Failed
7374.419981 Check DTC Present DTC 0x983F2A reported in diagnostic response. fail
15. Change the state of the relay, Expected: Park 1 button is pressed: Passed
7374.419981 Change Relay State Relay vt2820_channel_6 - Relay 6 state was changed to PUSHED pass
16. Change the state of the relay, Expected: Park 2 button is pressed: Passed
7374.419981 Change Relay State Relay vt2820_channel_7 - Relay 7 state was changed to PUSHED pass
17. Wait for close relay: None
7374.424981 1 Waited for 5.000 ms -
18. Set power supply voltage to 15.75V: Passed
18.1. VTS_Set_Power_Supply_Voltage_RangeZeroTo28V: Passed
7374.424981 Set power supply voltage Voltage set properly to 15.750000 V on vt2816_13 channel pass
19. Check that the SWMRiLvrDiagRiLvrDiag value has been set to 2 within 200s Expected: The signal has been set: Passed
7554.470320 Resume reason Resumed on signal: CAN signal 'SWMRiLvrDiagRiLvrDiag' Elapsed time=180045ms (max=200000ms) -
7554.470320 1
[−] Waited for occurrence of 1 value condition and signal updates.
Symbol Op. Reference value Actual Result
CAN signal 'SWMRiLvrDiagRiLvrDiag' == 2 2 pass
pass
20. Wait 8s: None
7562.470320 1 Waited for 8.000 s -
21. Set power supply voltage to 16.25V: Passed
21.1. VTS_Set_Power_Supply_Voltage_RangeZeroTo28V: Passed
7562.470320 Set power supply voltage Voltage set properly to 16.250000 V on vt2816_13 channel pass
22. Wait 10s: None
7572.470320 1 Waited for 10.000 s -
23. Send diagnostic request "Report DTC By status Mask 0xFF" Expected: Positive response : Passed
7572.470320 Diagnostic request 0x19, 0x02, 0xFF -
7572.471916 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.5955ms (max=1000ms) -
7572.471916 Report DTC By Status Mask Request Report DTC By Status Mask was succesfully transmitted with status mask: 0xFF pass
7572.476188 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=4.27186ms (max=1200ms) -
7572.476188 Get Diagnostic Response Positive response was received. -
7572.476188 Diagnostic response 0x59, 0x02, 0xFF, 0x95, 0x4F, 0x96, 0x2F, 0xDC, 0x40, 0x88, 0x50, 0xF0, 0x03, 0x62, 0x27, 0xEF, 0x00, 0x55, 0x50, 0xE1, 0x01, 0x56, 0x50, 0x06, 0x06, 0x47, 0x50, 0x06, 0x06, 0x48, 0x50 -
7572.476188 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
24. Check DTC absent Expected: DTC B183F2A not reported in diagnostic response : Passed
7572.476188 Check DTC Present DTC 0x983F2A not reported in diagnostic response. pass
25. Set power supply voltage to 15.75V: Passed
25.1. VTS_Set_Power_Supply_Voltage_RangeZeroTo28V: Passed
7572.476188 Set power supply voltage Voltage set properly to 15.750000 V on vt2816_13 channel pass
26. Wait 8s for DTC reached TestFail Limit: None
7580.476188 1 Waited for 8.000 s -
27. Send diagnostic request "Report DTC By status Mask 0xFF" Expected: Positive response : Passed
7580.476188 Diagnostic request 0x19, 0x02, 0xFF -
7580.477391 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.20366ms (max=1000ms) -
7580.477391 Report DTC By Status Mask Request Report DTC By Status Mask was succesfully transmitted with status mask: 0xFF pass
7580.486105 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=8.71425ms (max=1200ms) -
7580.486105 Get Diagnostic Response Positive response was received. -
7580.486105 Diagnostic response 0x59, 0x02, 0xFF, 0x95, 0x4F, 0x96, 0x2F, 0x98, 0x3F, 0x2A, 0x2F, 0xDC, 0x40, 0x88, 0x50, 0xF0, 0x03, 0x62, 0x27, 0xEF, 0x00, 0x55, 0x50, 0xE1, 0x01, 0x56, 0x50, 0x06, 0x06, 0x47, 0x50, 0x06, 0x06.. -
7580.486105 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
28. Check DTC status Expected: DTC active, Bits 0,1,2,3,5 set to 1 in hex 0x2F: Passed
7580.486105 Compare values
[−] Check DTC Status Mask
Symbol Op. Reference value Actual Result
Expected status mask for DTC 0x983F2A: 0x2F Received: 0x2F == 47 47 pass
pass
Completion of Test Case
Timestamp Test Step Description Result
1. Wait 500ms: None
7580.986105 1 Waited for 500.000 ms -
2. Send diagnostic request "Clear Diagnostic Information" Expected: Positive response: Passed
7580.987337 Resume reason Resumed on Diagnostics request sent to 'SWM' Elapsed time=1.23192ms (max=1000ms) -
7580.987337 Clear Diagnostic Information Request Clear Diagnostic Information was succesfully transmitted. -
7581.006698 Resume reason Resumed on Diagnostics response from 'SWM' Elapsed time=19.3607ms (max=1200ms) -
7581.006698 Get Diagnostic Response Positive response was received. -
7581.006698 Diagnostic response 0x54 -
7581.006698 Compare values
[−] Check diagnostic response
Symbol Op. Reference value Actual Result
diagnostic response status == positive response positive response pass
pass
7581.006698 VT System Cards Configuration General-Purpose Relay Module - M2_VT2820 -
3. Change the state of the relay, Expected: VCC line connected to DUT: Passed
7581.006698 Change Relay State Relay vt2820_channel_13 - Relay 13 state was changed to RELEASED pass
4. Change the state of the relay, Expected: GND line connected to DUT: Passed
7581.006698 Change Relay State Relay vt2820_channel_14 - Relay 14 state was changed to RELEASED pass
5. Set the supply voltage of the DUT, Expected: Voltage = 12.0 V: Passed
5.1. VTS_Set_Power_Supply_Voltage_RangeZeroTo28V: Passed
7581.006698 Set power supply voltage Voltage set properly to 0.000000 V on vt2816_13 channel pass
6. Wait for configuration to be set: None
7581.106698 1 Waited for 100.000 (setup_time_1) ms -
End of Test Group: Right Stalk General Signal Failures Signal Stuck In Range
End of Test Unit: TestUnit_VCC_GPA_SWM_VTS
End of Report